User Manual for DAUDIN models including: GFGW-RM01N Remote I O Module System, GFGW-RM01N, Remote I O Module System, Module System
2023-04-03 — I. The interface module can convert the gateway's RS485 port into a RJ45 connection. II. The main controller is in charge of the management and dynamic ...15 puslapių
2302EN V2.0.0 and Schneider PLC Modbus TCP Connection Operating Manual Table of Contents 1. Remote I/O Module System Configuration List .................................................................. 3 1.1 Product Description.............................................................................................................. 3 2. Schneider TM241 Connection Setup ................................................................................... 4 2.1 i-Designer Program Setup .................................................................................................... 5 2.2 Schneider TM241 Hardware Connections ......................................................................... 10 2.3 Schneider TM241 Connection Setup ................................................................................. 11 2 1. Remote I/O Module System Configuration List Part No. Specification Description GFGW-RM01N Modbus TCP-to-Modbus RTU/ASCII, 4 Ports Gateway GFMS-RM01S Master Modbus RTU, 1 Port Main Controller GFDI-RM01N Digital Input 16 Channel Digital Input GFDO-RM01N Digital Output 16 Channel / 0.5A Digital Output GFPS-0202 Power 24V / 48W Power Supply GFPS-0303 Power 5V / 20W Power Supply 0170-0101 8 pin RJ45 female connector/RS-485 Interface Interface Module 1.1 Product Description I. The interface module can convert the gateway's RS485 port into a RJ45 connection. II. The main controller is in charge of the management and dynamic configuration of I/O parameters and so on. III. The power module and interface module are standard for remote I/Os and users can choose the model or brand they prefer. 3 2. Schneider TM241 Connection Setup This section details how to connect a gateway to Schneider TM241. For detailed information regarding , please refer to the -Series Product Manual 4 2.1 i-Designer Program Setup I. Make sure that the module is powered and connected to the gateway module using an Ethernet cable II. Click to launch the software 5 III. Select "M Series Module Configuration" IV. Click on the "Setting Module" icon 6 V. Enter the "Setting Module" page for M-series VI. Select the mode type based on the connected module 7 VII. Click on "Connect" VIII. Gateway Module IP Settings Note: The IP address must be in the same domain as the controller equipment 8 IX. Gateway Module Operational Modes Note: Set Group 1 as Slave and set the gateway to use the first set of RS485 port to connect to the main controller (GFMS-RM01N) 9 2.2 Schneider TM241 Hardware Connections This section details how to use the SoMachine program to connect TM241 and I. Modbus TCP connects with the gateway via the Ethernet cable going through the Ethernet port on the TM241 10 2.3 Schneider TM241 Connection Setup I. Launch SoMachine and click on "" on the right side of the program 1. Click on "Ethernet_1 (EthernetNetwork)" 2. Under "fixed IP Address", set up the controller's IP Address and Subnet Mask 3. Right-click on "Ethernet_1 (EthernetNetwork)" and then click on "Add Device..." 4. In "Protocol Managers", click to add a new "Industrial Ethernet Manager" 11 II. Add New Devices 1. Right-click on "Industrial Ethernet Manager" and then select "Add Device..." 2. Under "Modbus TCP Slaves", click to add a new "Generic Modbus TCP Slave" III. Set up gateway IP address 1. Select "Generic Modbus TCP Slave" 2. Select "Modbus TCP Slave Configuration" and set up the gateway IP address under "Slave IP Address" 12 IV. Reading Register Setup 1. Select "Modbus TCP Channel Configuration" 2. Select "Add Channel..." 3. Set up the Master ID under "Unit ID" 4. Under "Function Code", select "Read Holding Registers (Function Code 03)" 5. In the "Offset" field, enter "4096" for the read register's IP address 6. In the "Length" field, set up the data amount for reading V. Write Register Setup 1. Select "Add Channel..." 2. Set up the Master ID under "Unit ID"" 3. Under "Function Code", select "Write Multiple Registers (Function Code 16)" 4. In the "Offset" field, enter "8192" for the Write register's IP address 5. In the "Length" field, set up the data amount for writing 13 VI. Command Address Mapping 1. Select "Modbus TCP Slave I/O Mapping" 2. Enter the I/O mapping name in "Input" 3. Enter the I/O mapping name in "Output" Notes: 's first GFDI-RM01N has the register address at 1000(HEX) converted to (DEC) with the starting address at 4096 's first GFDO-RM01N has the register address at 2000(HEX) converted to (DEC) with the starting address at 8192 14 VII. Sample Program Control with one GFDI-RM01N and one GFDO-RM01N When the first point of DI has received a signal and is triggered, the first point of DO will output a signal as it is connected 15Adobe PDF Library 22.3.98