User Guide for OPTICON models including: OPH-1005, Handheld Data Portable Terminal, Data Portable Terminal, Handheld Portable Terminal, Portable Terminal, Terminal
Download Opticon OPH-1005 Quick Start Manual PDF
File Info : application/pdf, 2 Pages, 1.91MB
DocumentDocumentOPH-1005 Quick Start Guide Introduction · Read this quick start guide carefully before installing and/or using this product. · Keep this quick start guide for future reference and store in a safe place. Notice · This quick start guide may be revised or withdrawn at any time without prior notice. · This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or con- verted to any electronic or machine readable form without prior written consent of Opticon. · Trademarks used are property of their respective owners. · Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect damages howsoever caused. Caution and Warning (Please refer to the specification manual and instruction guide for details.) 1. Laser Safety · Do not stare into the laser beam. 2. Handling Instructions OPH-1005 · Do not attempt to disassemble, modify or update this device. · Operating the scanner while operating machinery or a vehicle can be distracting. · Do not drop this product or put heavy items on this product. · Do not insert foreign substances into the device. · Do not use this product in the following areas: - In areas exposed to direct sunlight for long periods of time. - In dusty environments. - Near water or other liquids, or in extremely high humidity. - Near heat sources, such as radiators, heat registers, stoves, or other types of devices that produce heat. - Near microwaves or medical devics. · When cleaning this product, rub gently with either a soft dry cloth or a damp cloth with mild detergent. Battery Pack · Do not attempt to disassemble this battery. · Do not expose the battery pack to liquids or allow the battery contacts to get wet. · Do not expose the battery pack to heat sources including other devices that produce heat. · Do not short the power leads on the battery pack. If the (+) and (-) terminals come in contact with metals (such as a necklace or hairpin), a short-circuit will occur. · Do not load the battery pack with its (+) and (-) terminals reversed. · Check the local regulations for proper battery disposal. Before Getting Started What's in the Box Confirm that you have the following items before getting started: No. Item 1 Portable Terminal 2 Strap 3 Quick Start Guide Function A laser portable terminal with a barcode scanning feature. Provides product information and instruction guide. * The number of accessories may differ depending on the product specification. Please contact the nearest dealer if accessories are damaged or missing. Copyright© 2012, Opticon All rights reserved. Overview OPH-1005 Basic Specifications Detailed View Parameter Physical Size Features Weight Control CPU Section OS Specifications (H) 136.1 x (W) 55.4 x (D) 22.8 mm Approx. 140g (including Li-ion battery) 32bit MCU 1SPQSJFUBSZ Memory Display Section FROM 4MB RAM 4MB Material LCD (262144 color) Number of dots 320 dots x 240 dots Dot size Dot pitch 0.24mm x 0.24mm 0.18mm Backlight White LEDs Contrast Control Enabled Other Display LED Section Buzzer Bi-color LED (Red and Green) Tone and loudness can be configured Operation Section Keys 23 keys Scanning Light Source Red laser diode Section Wavelength 650 10nm Light Output 1mW or less No. Part Function Scan Rate 100 20scan /sec Supported Symbologies JAN, EAN, UPC-A, UPC-E, NW7(Codabar), Industrial 2 of 5, Interleave d 2 of 5, Co de 11, Code 39, Code 93, Code 128, MSI/Plessey, UK/Plessey, IATA, Telepen, Matrix 2 of 5, S-Code, Tri-Optic, Chinese Post, EAN 128, RSS-14, RSS Limited, RSS Expanded, PDF417, MicroPDF417 Power Supply Section Main Battery Lithium-ion battery (3.7V 1100mAh) Backup Battery Manganese dioxide lithium-ion battery (11mAh) Operating Time Approx. 40 hours (1 scan/10 sec) Data Retention Time 24 hours Comm. Section IrDA IrDA Ver. 1.2 Baud rate: (SiR): 9600 to 115.2kbps Clock Real Time Supports year, month, day, hour, Section Clock (RTC) minute, second (leap year supported) Durability Operating Temp. -10 deg. C to 50 deg. C Operating Humidity 20% to 85% (non-condensing) LCD Indicates the status of program execution, scanned data and so on. Status LED (Red and Green) Alerts users the status of scanning operation and data communication. The scan engine emits a laser beam Optical Window through the optical window while scanning a barcode. SCAN Key Starts a barcode scanning operation. POWER Key Turns ON or OFF the power. IrDA This portable terminal communicates Communication with the designated cradle through Window the IrDA communication window. Buzzer Hole Buzzer sounds through the buzzer hole. Battery Cover Protects the battery pack. Charging Terminals Electrical terminals for power distribution and power management. Strap Hook Storage Temp. -20 deg. C to 60 deg. C Storage Humidity 20% to 85% (non-condensing) Charging Temp. 0 deg. C to 40 deg. C Ambient Light Fluorescent: up to 4,000lx Immunity Sunlight: up to 80,000lx Dust- and Drip-proof IP 54 Shock Endurance Dropped 3 times from each of 6 angles onto concrete from a height of 150cm with no defects found. (Total 18 times) To avoid communication problems between the portable Memo terminal and a cradle, keep the IrDA communication window clean. The IrDA communication performance may decline due to excessive ambient light especially under strong sunlight or inverted fluorescent light. Key Layout Overview Key SCAN Q1 Q2 SHIFT BS CLR POWER 0-9, . ENT F1-F4 Function Scans a barcode. Navigate through the menu or toggle between options. ( These keys can be programmed suitable for user`s application. ) Shifts from l number input mode z tol alphabet input mode zand vice versa. Deletes one letter before the cursor. Cancels an input. Turns the power ON and OFF. 10 numeric keys to input numbers, alphabets or symbols. Determines the input. 4 function keys which can be programmed by a user. * The layout of keys may differ depending on the Memo product specification. Usingthe PortableTerminal How to Insert or Exchange a Battery STEP 1 STEP 1 Please open the battery cover before inserting or exchanging a battery. STEP 2 STEP 2 Make sure that the battery contacts are in contact with the spring contacts of the portable terminal. STEP 3 STEP 3 Please close the battery cover. * When the cover is not closed correctly the portable terminal will not be turned ON. How to Scan a Barcode Please refer to the following examples of a scanning operation. Make sure that the barcode is within the width of the laser aiming pattern. Correct Incorrect · When cleaning this product, rub gently with either a soft dry cloth or a damp cloth with mild detergent. Battery Pack · Do not attempt to disassemble this battery. · Do not expose the battery pack to liquids or allow the battery contacts to get wet. · Do not expose the battery pack to heat sources including other devices that produce heat. · Do not short the power leads on the battery pack. If the (+) and (-) terminals come in contact with metals (such as a necklace or hairpin), a short-circuit will occur. · Do not load the battery pack with its (+) and (-) terminals reversed. · Check the local regulations for proper battery disposal. Before Getting Started What's in the Box Confirm that you have the following items before getting started: No. Item 1 Portable Terminal 2 Lithium-ion Battery Pack 3 Strap 4 Quick Start Guide Function A laser portable terminal with a barcode scanning feature. Designated battery pack for the OPH-1004. Provides product information and instruction guide. * The number of accessories may differ depending on the product specification. Please contact the nearest dealer if accessories are damaged or missing. Copyright© 2008, Opticon All rights reserved. Key Layout Overview Key SCAN Q1 Q2 SHIFT BS CLR POWER 0-9, . ENT F1-F4 Function Scans a barcode. Navigate through the menu or toggle between options. ( These keys can be programmed suitable for user`s application. ) Shifts from l number input mode z tol alphabet input mode zand vice versa. Deletes one letter before the cursor. Cancels an input. Turns the power ON and OFF. 10 numeric keys to input numbers, alphabets or symbols. Determines the input. 4 function keys which can be programmed by a user. * The layout of keys may differ depending on the Memo product specification. Designated Cradles (Optional)* We offer a series of communication and charging cradles with different communication methods. Please select the most suitable cradle for the desired operation. Communication & Charging Cradle CRD-1001 RS-232C USB Communication Method (Cradle to Host) Size Weight Charging Time Communicates with the host via RS-232C or USB interface. (H)70.0 (W)68.0 (D)96.0 mm Max 110g Max (excluding AC adapter and cable) 2 hours and 10 minutes Communication & Charging Cradle CRD-1002 MODEM Communication Method (Cradle to Host) Size Weight Charging Time Communicates via telephone line and connects to the Public Switched Telephone Network (PSTN) (H)70.0 (W)68.0 (D)96.0 mm Max 100g Max (excluding AC adapter and cable) 2 hours and 10 minutes Communication & Charging Cradle CRD-1003 GSM Communication Method (Cradle to Host) Size Weight Charging Time Communicates with the host via GSM (Global System for Mobile Communications) Network. (H)70.0 (W)68.0 (D)96.0 mm Max 115g Max (excluding AC adapter and cable) 3 hours Communication & Charging Cradle CRD-1004 ETHERNET USB Communication Method (Cradle to Host) Size Weight Charging Time Communicates with the host via Ethernet or USB. (H)70.0 (W)68.0 (D)96.0 mm Max 115g Max (excluding AC adapter and cable) 3 hours * Please refer to the specification manual or the instruction guide for details of designated cradles. Memo * A designated SIM card will be needed to use the CRD-1003 GSM cradle. RSS-14, RSS Limited, RSS Expanded, PDF417, MicroPDF417 Power Supply Section Main Battery Lithium-ion battery (3.7V 1100mAh) Backup Battery Manganese dioxide lithium-ion battery (18mAh) Operating Time Approx. 80 hours (2 scans/10 sec) Data Retention Time More than 7 days Comm. Section IrDA IrDA Ver. 1.2 Baud rate: (SiR): 9600 to 115.2kbps Clock Real Time Supports year, month, day, hour, Section Clock (RTC) minute, second (leap year supported) Durability Operating Temp. -10 deg. C to 50 deg. C Operating Humidity 20% to 85% (non-condensing) Storage Temp. -20 deg. C to 60 deg. C Storage Humidity 20% to 90% (non-condensing) Charging Temp. 0 deg. C to 40 deg. C Ambient Light Fluorescent: up to 4,000lx Immunity Sunlight: up to 80,000lx Dust- and Drip-proof IP54 Shock Endurance Dropped 3 times from each of 6 angles onto concrete from a height of 150cm with no defects found. (Total 18 times) scanning a barcode. SCAN Key Starts a barcode scanning operation. POWER Key Turns ON or OFF the power. IrDA This portable terminal communicates Communication with the designated cradle through Window the IrDA communication window. Buzzer Hole Buzzer sounds through the buzzer hole. Battery Cover Protects the battery pack. Charging Terminals Electrical terminals for power distribution and power management. Strap Hook To avoid communication problems between the portable Memo terminal and a cradle, keep the IrDA communication window clean. The IrDA communication performance may decline due to excessive ambient light especially under strong sunlight or inverted fluorescent light. Usingthe PortableTerminal How to Insert or Exchange a Battery STEP 1 STEP 1 Please open the battery cover before inserting or exchanging a battery. STEP 2 STEP 2 Make sure that the battery contacts are in contact with the spring contacts of the portable terminal. STEP 3 STEP 3 Please close the battery cover. * When the cover is not closed correctly the portable terminal will not be turned ON. How to Scan a Barcode Please refer to the following examples of a scanning operation. Make sure that the barcode is within the width of the laser aiming pattern. Correct Incorrect Trouble Shooting The portable terminal does not get powered ON. A. The battery level of the portable terminal may be extremely low or empty. Please try again after you charge the portable terminal. B. Check if the battery cover is closed tight. The portable terminal does not read a specific type of barcode. A. That specific type of barcode may not be supported by the portable terminal. Please confirm the specification manual of the portable terminal for details of supported symbologies. B. The specific type of barcode may not be enabled in the application. Change the settings in your application. The portable terminal does not read a barcode smoothly. A. The scanning performance of the portable terminal may decline due to inappropriate scan angle. Please adjust the angle of the portable terminal and try again. Make sure that the barcode is within the width of the laser aiming pattern. Contact Please contact OPTICON or your local dealer. The Netherlands U.S.A. France Germany Italy Opticon Sensors Europe B.V. tel: +31 (0)23-5692700 / email: sales@opticon.com Opticon Inc. tel: 800-636-0090 / email: opticon@opticonUSA.com Opticon S.A.S. tel: +33 (0)1-41461260 / email: opticon@opticon.fr Opticon Sensoren GmbH tel: +49 (0)6074-91890-0 / email: sales.de@opticon.com Opticon s.r.l. tel: +39 (0)051-6321800 / email: opticon@opticonitalia.it Sweden United Kingdom Taiwan China Australia Brazil Opticon Sensors Nordic AB tel: +46 (0)8-58548560 / email: henrik@opticon-sensors.se Opticon Limited tel: +44 (0)1582-635100 / email: sales@opticon.co.uk Opticon Far Eastern Ltd. tel: +886 2-27597444 / email: taiwan@opticon.com Opticon Sensors Europe B.V., Shanghai Representative Office tel: +86 21-64480881 / email: china@opticon.com Opticon Sensors Pty. Ltd. tel: +61 (0)2-43402666 / email: sales@opticon.com.au Opticon Sensors Europe B.V., Latin American Office tel: +55 11-5081 2088 / email: sales.la@opticon.com More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com. QSG-OPH1005-00