INSTALLATION MANUAL EN

EN 8 H The unit can be placed on a balcony or hanged to the wall using the support bracket kit (not sup-plied). I Drill the holes and fix the support to the wall using the rawl plugs. L Remove the plastic plugs from quick couplings, connect the couplings by hand, then tighten using the torque wrenches (tightening torque 150 ÷ 165

MANUALE D'INSTALLAZIONE

ARGO ULISSE ECO | Argo


File Info : application/pdf, 14 Pages, 1.74MB

PDF preview unavailable. Download the PDF instead.

374256043-01 I-AR-ULISSE-DCI-ECO-EN-1
INSTALLATION MANUAL EN MANUALE DI INSTALLAZIONE IT
NOTICE D'INSTALLATION FR INSTALLATIONSANLEITUNG DE INSTRUCCIONES DE INSTALACIÓN ES INSTRUCÇÕES DE INSTALAÇÃO PT

9+3:5*+

4OMNZ

,ORZKX

+IU

:OSKX

:[XHU

2OMNZ

AUTO

W

EEK

SET

A

S

M

T

W

T

21 3

F S

Room air conditioner with remote condenser Condizionatore d'ambiente con condensatore remoto Climatiseur avec condenseur a air exterieur - Klimagerät mit außengerät Acondicionador de ambiente con condensador a distancia
Ar Condicionado com condensador remoto
37.4256.043.01 12/2023

CONTENTS

EN

1 - General precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2 - Installation site selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3 - Accessories and tools required for installation . . . . . . . . . . . . . . .3

4 - Dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 5 - Minimum operation and maintenance area . . . . . . . . . . . . . . . . . .4 6 - Tubing length and elevation difference limits. . . . . . . . . . . . . . . . .4 7 - Installation of outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 8 - Wall installation (through a hole in the wall) . . . . . . . . . . . . . . . . . .7

9 - How to connect the flexible tube extension kit . . . . . . . . . . . . . . .9 10 - Remote control unit installation . . . . . . . . . . . . . . . . . . . . . . . . . .10 11 - Maintenance of the refrigerant circuit. . . . . . . . . . . . . . . . . . . . . .10 12 - Match between remote controller and the unit . . . . . . . . . . . . . .11 13 - Electrical wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

REGULATION (EU) No. 517/2014 - F-GAS The unit contains R32, ua fluorinated greenhouse gas with a global warming potential (GWP) of 675. Do not release R32 into the atmosphere.
R32 (STANDARD): 0.750 kg / 0.506 Tonn. CO2 eq. R32 (STANDARD + 2 m): 0.785 kg / 0.530 Tonn. CO2 eq. R32 (STANDARD + 4 m): 0.820 kg / 0.554 Tonn. CO2 eq.

Power supply: 220 - 240 V ~ / 1 / 50 Hz

The unit contains R32, a slightly flammable gas. Before installing the unit, read this installation manual and streactly follow all safety instructions. Always contact an Argoclima Service Center. Any repair must be performed by qualified personnel, following the instructions contained in the manufacturer's technical manual.

IMPORTANT
· Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer.
· The unit has to be stored in a room that doesn't have any continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
· Do not pierce or burn the unit. · Be aware that refrigerants do not have any odour. · This unit has to be installed, operated and stored in a room with a floor area larger than 6m2. The room
must be well ventilated.
IN CASE OF MAINTENANCE OF THE REFRIGERANT CIRCUIT · The installer must be in possession of the F-GAS certification without any integration. · The installer must have the appropriate equipment (vacuum pump and recuperator) certified for R32.

2

1 - GENERAL PRECAUTION
· Check that the voltage and frequency of the power supply match those required by the system. · Check the possibility to have the power line to the indoor unit (ELECTRIC CABLE LENGTH 3 m). · Install a double - pole switch, protected by 10 A fuses of the delayed type, upstream the electricity wall socket. · Make sure that the electrical installation is suitable to supply continuosly current necessary for the air conditioner in
addition to that already used by other electric appliances (white goods, lighting). See the max electric imput indicated on the name plate positioned on the air conditioner. · Before connecting the air conditioner to a power socket, make sure that the socket is provided with an earth connection in compliance with local codes.

EN

2 - INSTALLATION SITE SELECTION
INDOOR UNIT AVOID: · Positioning the indoor unit into rooms where it could be sprinkled with water (i.e. laundries). · Installation in areas where leakage of flammable gas or large amount of mist may be expected humidity location. · Direct sunlight or near by heat source that may affect performance of the unit. · Installing the unit behind curtains or furniture that obstruct air circulation. DO: · Choose a position which allows proper ventilation in the room. · Verify respect of the minimum recommended maintenance space.
OUTDOOR UNIT AVOID: · Direct sunlight or area where hot air from exhaust fans investing the unit. DO: · Choose a place as cool as possible and well ventilated.

3 - ACCESSORIES AND TOOLS REQUIRED FOR INSTALLATION

ACCESSORIES SUPPLIED WITH THE UNIT

A AUTO
SET

SMTWT F S 1
23

FIGURE

+IU

:[XHU

:OSKX

2OMNZ

PARTS

NR°

REMOTE

UNIT CONTROL

1

,ORZKX

4OMNZ

35*+ 9+:

WEEK

BATTERIES FOR REMOTE CONTROL 2

PLASTIC PLUG

(MALE AND

2 + 2

FEMALE)

FELT PADS

4

SUPPORTS FOR

REMOTE UNIT

2

CONTROL

OUTDOOR UNIT SUPPORT BRACKET KIT

ACCESSORY SUPPLIED ON REQUEST

RAWL PLUG

3

S X 10

SCREW 7x65

3

WASHER

3

OUTDOOR UNIT

SUPPORT AND

1+1

GUIDE

SCREW 4,2x13

2

CONNECTION EXTENSION KITS LENGHT OF 2 OR 4 m

ACCESSORY SUPPLIED ON REQUEST

FIGURE

PARTS

NR°

EXTENSION KIT

FOR CONNEC-

1

TION TUBE

CONNECTIONS

1

PLASTIC BOX

RAWL PLUG

3

TAPPING SCREW

3

ø 3,5 x 45

CLAMP

2

THE EXTENSION KITS ARE SUPPLIED PRECHARGED

Before the installation, verify that they are fit for the unit.

NARROW TUBE OUTSIDE DIA.

LARGE TUBE OUTSIDE DIA.

6,35 mm

7,93 mm

TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED) · Phillips head screw driver · Tape measure · Level · Hammer drill · Hole saw or key hole saw ø 50 · 19 mm wrench · 21 mm wrench · 24 mm wrench · Hammer · Hacksaw · Core bits 10 mm diameter drill bit.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED) · Synthetic oil HAB - Alkylbenzene type ex. EXXON ZERICE S, about 30 gr. · PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.

3

4 - DIMENSIONS AND WEIGHT
EN

Net weight: 57 Kg

800

250 490

245

1400 mm
clst
200 mm
B

580

525

5 - MINIMUM OPERATION AND MAINTENANCE AREA

100 mm

780 mm

100 mm

2000 mm

Unit: mm
800 mm

150 mm
A
6 - TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS

150 mm

50 mm

1500 max

Standard mm
A 1500

AA
2 m system extension kit A
3500
4

4 m system extension kit
A 5500

7 - INSTALLATION OF OUTDOOR UNIT

A

The outdoor unit may be placed on a balcony. Make sure to put it in vertical position and lev-

elled. During the installation do not kink the con-

nection tube between the units. Verify the correct

air circulation around the outdoor unit.

B Or fixed to the window sill.

EN

Min. 25 cm.

C

Or hanged to the wall below the window sill using the support bracket kit (not supplied). After plac-

ing the unit in the support, check that it is levelled.

3 x ø 10 Holes

D

Insert the support in the handle of the outdoor unit, turn the outdoor unit upside down (see the

picture).

Place the support and secure it at the edge of the

unit. Insert the support guide fixed on the unit at

the wall. Make sure it is levelled.

Support

100 min. 200
140

5

EN E Do not handle the outdoor unit improperly.
NO

F

When recovering the outdoor unit after operation drain away any remaining condensate by tilting

the unit.

G

Place the indoor unit against the wall next to an electric socket.

TEST OFF ON

6

8 - WALL INSTALLATION (THROUGH A HOLE IN THE WALL)
IMPORTANT OPERATION TO BE EXECUTED BY COMPETENT OR QUALIFIED PERSONEL
1. Before disassembling the outdoor unit (disjoin the rapid couplings): connect the air conditioner to a socket and let the compressor work for 5 minutes. During the disassembling operation, beat lightly with a spanner on the rapid coupling brass body (exagonal part).
2. Lubricate the joint surfaces (rapid coupling) with a little bit of HAB oil only (synthetic oil Alkylbenzene type ex. EXXON ZERICE S ).
3. When you disjoin the outdoor unit, follow the described succession: first, disconnect the power supply of the air conditioner (disconnect the plug), disconnect the electric connector, then the pipes of the frigorific connection.

EN

A

Choose the best position where to install indoor unit. Mark the hole to be made in the wall.

B Drill a 50 mm diameter hole, insert a PVC pipe.

60

Indoor

Outdoor

ø 50

5 - 10 mm

50

C Remove the coupling cover of the outdoor unit.

D

Disconnect the condensate plastic tube and the electric connector.

E

Loosen the quick coupling using the 19-21 mm spanners first and then the 19-24 mm spanners.

Unscrew the flare nuts by hand and disconnect

the flexible tube.

F

Protect quick coupling (on flexible tube and outdoor unit) with plastic plugs supplied as accesso-

ries. To insert the tubing into the hole in the wall

easily and without damages, join the pipe ends

and wrap them with adhesive tape.

Plastic plugs

NOTE: When disconnecting or reconnecting the flexible tubes, always use two proper wrenches: one to hold the fixed part and one to screw/unscrew. WARNING: Do not lift the tubes when operating on the couplings as it may damage the tubes and lead to refrigerant leakage.
7

EN

G

Insert the flexible tube into the hole drilled in the wall. Place the unit against the wall, if necessary, adjust the four antivibration supports in order to

keep the unit levelled.

NOTES:

· The four antivibration supports are rubber

made and they could mark the floor; in this

case the application of proper material under

the support is recommended or use the sup-

plied felt pads.

· When you move the unit,

never tilt it, to avoid dam-
TEST OFF ON
aging the floor.

H

The unit can be placed on a balcony or hanged to the wall using the support bracket kit (not sup-

plied).

WARNING
When you assemble the outside unit, follow the described succession: first, connect the pipes for frigorific connection, then the electric connector.

I

Drill the holes and fix the support to the wall using the rawl plugs.

L

Remove the plastic plugs from quick couplings, connect the couplings by hand, then tighten using

the torque wrenches (tightening torque 150 ÷ 165

kgcm).

M

Connect the condensate plastic tube and the electric connector.

WARNING: Do not lift the tubes when operating on the couplings as it may damage the tubes and lead to refrigerant leakage.

N

Fix the coupling cover of the outdoor unit and seal the hole in the wall around the flexible tube.

8

9 - HOW TO CONNECT THE FLEXIBLE TUBE EXTENSION KIT IMPORTANT OPERATION TO BE EXECUTED BY COMPETENT OR QUALIFIED PERSONEL

EN

A

Carefully unroll the extension tube; be careful not to twist nor kink it.

B

Remove the plastic plug from extension tube ends (preformed tubes side).

NO

YES

C

Fit the copper tubes on the support bent side. Connect the couplings by hand, adjust careful-

ly the tubes on unit top, then tighten using the

torque wrenches (tightening torque 150 ÷ 165

kgcm).

D

Connect the condensate plastic tube and the electric connector.

30 mm

NOTE: When disconnecting or reconnecting the flexible tubes, always use two proper wrenches: one to hold the fixed part and one to screw/unscrew. WARNING: Do not lift the tubes when operating on the couplings as it may damage the tubes and lead to refrigerant leakage.

F

Remove the plastic plugs from opposite end of flexible tube and connect quick couplings, first by

hand and then using the spanners.

Cut the PVC tube (soft kind) in excess then insert

it into the stiff one.

E Fix the coupling cover of the outdoor unit.

NOTE: When disconnecting or reconnecting the flexible tubes, always use two proper wrenches: one to hold the fixed part and one to screw/unscrew. WARNING: Do not lift the tubes when operating on the couplings as it may damage the tubes and lead to refrigerant leakage.

9

G
EN

Open the quick coupling box.

H

Adjust the couplings in the box, connect the electric cable connector then turn it by 180°. Place

the electric cable and fix it to the pipe with the

smallest diameter through hose clamps. Fix the

gaskets on the connections box ends.

10 - REMOTE CONTROL UNIT INSTALLATION

To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places:

· In direct sunlight. · Behind a curtain or other places where it is covered. · More than 8 m. away from the air conditioner. · In the path of the air conditioner airstream. · Where it may become extremely hot or cold. · Where it may be subject to electrical or magnetic noise. · Where there is an obstacle between the remote control unit and air conditioner.

TABLE STAND

WALL SUPPORT

WALL-MOUNTED POSITION · Momentarily place the remote control unit in the desired mounting position. · Verify that the remote control unit can operate from this position. · Fix the support at the wall with two screws and hang the remote control unit.

11 - MAINTENANCE OF THE REFRIGERANT CIRCUIT

NOTES

IMPORTANT FOR MAINTENANCE

· Make sure there is no heat source or potential heat source in the maintenance area. The open flames are forbidden in the maintenance area and the "no smoking" sign must be hanged.
· Verify that the warning sign is in good condition, otherwise replace it.

Refrigerant recovery in case of maintenance or removal of the unit · If it is necessary to cut and weld the refrigeration circuit pipes during maintenance operations or to empty the
refrigerant circuit in the event of removal of the unit, carry out the following operations: 1. Turn off the unit and disconnect the power supply. 2. Recover the gas. 3. Make a vacuum with the vacuum pump. 4. Clean the pipes with N2 gas. 5. Cut and weld or bring the unit to the Service Center for welding. 6. Make a leak detection check.

· The refrigerant must be recovered in the appropriate storage tank for R32 gas. · Ensure that there is no naked flame near the vacuum pump outlet and that the area is well ventilated.

Charge of the refrigeration circuit · Refrigerant charge apparatus, vacuum pump, hoses and adapters must be exclusively used for R32. Make sure
that different types of refrigerant do not contaminate each other. · It is suggested to charge the refrigerant in LIQUID state. Make sure that the refrigerant is the one required. · Do not add any OIL to the compressor because precharged oil is specially selected for R410A. · The refrigerant tank should be kept upright during filling of the refrigerant circuit. · Stick the label on the system after you finish the refrigerant charge. · Do not overfill. · After completing the charge, check for leaks before doing the test run.

10

12 - MATCH BETWEEN REMOTE CONTROLLER AND THE UNIT

The remote control can be addressed to use up to 4 different units installed in the same room.

EN

You can get unified control by using a single remote control for all units or each remote control can be addressed to

its own unit, in order to control separately temperature, timer and all other functions.

PCB SETTING

· Disconnect the unit power supply and wait at least 60 seconds, mak-

ing sure that all the lamps go off.

· Remove the rear panel and the cover of the electrical box to access

the pcb.

· Set JP2 and JP3 as shown in the table.

· Close the cover of the electrical box and the rear panel.

· Reconnect the unit power supply.

REMOTE CONTROLLER SETTING

·

Press the

button

35*+ 9+:

for a

few seconds.

· Press the arrow until you visualize 06.

· Press the button 35*+ again for a few seconds: the number 0 (factory setting) at the botto9+m: starts flashing.

· Press the arrow to set 1, 2 or 3.

·

Confirm

with

the

button

35*+ 9+:

.

· Press to exit the menu.

UNIT

REMOTE CONTROL UNIT

PCB

0
FACTORY STATE

JP2=CLOSE JP3=CLOSE

1

JP2=OPEN JP3=CLOSE 2

JP2=CLOSE JP3=OPEN 3

JP2=OPEN JP3=APERTO

11

13 - ELECTRICAL WIRING DIAGRAMS - SCHEMI ELETTRICI - SCHÉMAS ÉLECTRIQUES - ELEKTRISCHE ANSCHLUSSPLÄNE - ESQUEMAS ELÉCTRICOS - DIAGRAMAS ELÉTRICOS
WiFI MODELS
12

Electrical wiring diagrams' symbols / Simboli schemi elettrici / Symboles des schemas électriques Legende: Anschlusspläne / Símbolos de los esquemas eléctricos / Símbolos de diagramas elétricos

SYMBOL
PC CM C1, 2, 3 IND. U. OUTD. U. FMO FMI IND. ASSY A1 FS A2 TH1, 2 INDUCTOR EMI FILTER

EG
CONDENSATE PUMP COMPRESSOR MOTOR CAPACITOR INDOOR UNIT OUTDOOR UNIT OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDICATOR ASSY CONTROLLER SAFETY FLOAT SWITCH SWITCH ASSY THERMISTOR INDUCTOR EMI FILTER

I
POMPA SCARICO CONDENSA MOTORE COMPRESSORE CONDENSATORE UNITA' INTERNA UNITA' ESTERNA MOTORE ESTERNO VENTOLA MOTORE INTERNO VENTOLA GRUPPO INDICATORI SCHEDA ELETTRONICA INT. SICUREZZA A GALL. GRUPPO INTERRUTTORI TERMISTORE INDUTTORE FILTRO DI RETE

F
POMPE D'EVACUATION DES CONDENSATS MOTEUR DE COMPRESSEUR CONDENSATEUR UNITÉ INTÉRIEURE UNITÉ EXTÉRIEURE MOTEUR DE VENTILATEUR EXTÉRIEUR MOTEUR DE VENTILATEUR INTÉRIEUR ENSEMBLE INDICATEUR CONTRÔLEUR INTERR. DE SECURITE A FLOTTEUR ENSEMBLE INTERRUPTEUR THERMISTOR INDUCTOR FILTRE DE RESEAU

D
KONDENSWASSERAUSLASS-PUMPE KOMPRESSORMOTOR KONDENSATOR INNENEINHEITEN AUßENEINHEITEN AUSSENLÜFTERMOTOR INNENLÜFTERMOTOR ANZEIGE-BAUGRUPPE STEUERGERÄT SCHWEMM-SCHUTZSCHALTER SCHALTER-BAUGRUPPE THERMISTOR INDUCTOR NETZFILTER

E
BOMBA DE DESCARGA DEL LIQUIDO DE COND. MOTOR DEL COMPRESOR CONDENSADOR UNIDAD INTERIOR UNIDAD EXTERIOR MOTOR VENTILADOR EXTERNO MOTOR VENTILADOR INTERNO GRUPPO DE INDICADORES CONTROLADOR INTERR. DE SEGURIDAD DE FLOTADOR GRUPPO DE INTERRUPTORES TERMISTOR INDUCTOR FILTRO DE RED

P
BOMBA DE DRENAGEM DE CONDENSADO MOTOR DO COMPRESSOR CAPACITOR UNIDADE INTERNA UNIDADE EXTERNA MOTOR VENTILADOR EXTERNO MOTOR VENTILADOR INTERNO GRUPO INDICADORES PLACA ELETRÔNICA INTERRUPTOR DE SEGURANÇA EM FLOAT GRUPO INTERRUPTORES TERMISTOR INDUCTOR FILTRO DE REDE

13

Wires color legend Legenda colori fili elettrici Légende des couleurs des fils électriques Beschriftung der Leitungs-Farben Leyenda de los colores de los cable electricos Legenda das cores dos fios elétricos

BLK BLU BRN GRN / YEL GRY ORG PNK RED VLT WHT YEL

EG
BLACK BLUE BROWN GREEN / YELLOW GREY ORANGE PINK RED VIOLET WHITE YELLOW

I
NERO BLU MARRONE VERDE / GIALLO GRIGIO ARANCIONE ROSA ROSSO VIOLA BIANCO GIALLO

F
NOIR BLEU MARRON VERT / JAUNE GRIS ORANGE ROSE ROUGE VIOLET BLANC JAUNE

D
SCHWARZ BLAU BRAUN GRÜN / GELB GRAU ORANGE ROSA ROT VIOLETT WEISS GELB

E
NEGRO AZUL MARRON VERDE / AMARILLO GRIS ANARANJADO ROSA ROJO VIOLETA BLANCO AMARILLO

P
PRETO AZUL MARROM VERDE / AMARELO CINZA LARANJA ROSA VERMELHO VIOLETA BRANCO AMARELO

S.A.C. - Printed in italy

Società a socio unico Via Alfeno Varo, 35 - 25020 Alfianello - BS - Italy
Tel. +39 030 7285700 www.argoclima.com

