Sloan Regal 186 XL Exposed Manual Urinal Flushometer
Code Number: 3982628
Description
0.5 gpf, XL Sweat Solder Adapter Kit, Polished Chrome Finish, Fixture Connection Top Spud, Single Flush, Regal® Exposed Manual Urinal Flushometer.
Details
- Flush Volume: 0.5 gpf (1.9 Lpf)
- Finish: Polished Chrome (CP)
- Valve: Diaphragm
- Valve Body Material: Semi-red Brass
- Fixture Type: Urinal
- Fixture Connection: Top Spud
- Rough-In Dimension: 11 ½" (292mm)
- Spud Coupling: ¾" (19mm)
- Supply Pipe: ¾" (19mm)
- Adapter: XL Sweat Solder Adapter Kit (XL)
Features
- Non-Hold-Open Handle and No External Volume Adjustment to Ensure Water Conservation
- ¾" I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant Stop Cap
- Spud Coupling and Spud Flange for ¾" Top Spud
- ADA Compliant Metal Oscillating Non-Hold-Open Handle
- Sweat Solder Adapter with Cover Tube
- Cast Wall Flange with Set Screw
- Vacuum Breaker Flush Connection
Image depicts a manual urinal flushometer with a polished chrome finish.
Variations Not Shown: Less Flush Connection and Less Vacuum Breaker
Compliances & Certifications
Icons represent various compliance and certification standards including ADA, BAA, BREEAM, cUPC, EPD, Green Globes, LEED, Made in USA, UPC, WaterSense, and WELL Building Standard.
Recommended Specification
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2.
Valve Operating Pressure (Flowing)
15-80 PSI (103-552 kPa). Specific fixtures may require greater minimum flowing pressure - consult manufacturer requirements.
Downloads
- Regal XL Exposed Installation Instructions
- Control Stop Repair and Maintenance Guide
- Flush Connections Flanges Repair and Maintenance Guide
- Tail Piece Repair and Maintenance Guide
- Regal Flushometers Repair and Maintenance Guide
- Flushometer Pressure gauges
- Additional Downloads
Notes
All information contained within this document subject to change without notice.
Looking for other variations of the REGAL 186 product? View the general spec sheet with all options.
WaterSense compliant when used with a WaterSense compliant fixture.
Warranty
View Warranty Information
Rough-In Diagram
Diagram shows the side view of a urinal with the flushometer installed. Key dimensions include the rough-in dimension of 11 ½" (292mm) from the finished wall to the centerline of the waste, and the minimum clearance of 2 ¼" (57mm) from the flushometer to the finished wall. The supply pipe connection is shown as ¾" I.P.S. (DN 20 mm).