Operation Instruction
A. Features
- 13 Digits, Hour, Minutes, Seconds, Month, Day and Week
- Daily Alarm, Month&Date Alarm, and Chime hourly
- 1/100 second Chronograph with split count
- Second Time (DT) function
- Count Down (Upper limit: 24H)
- 2000-2099 Calendar, 12/24H format
- EL backlight
B. Operational Manual
EL Backlight
At any station, press the [A] key to turn on the EL backlight for 3 seconds.
Mode Conversion
In Normal time Mode, press the [B] key to convert modes:
- Normal time Mode
- Alarm Mode
- Chronograph Mode
- Second Time (DT) Mode
- Count Down Mode
The display cycles through modes upon pressing the [B] key. Key functions are indicated by letters: (A) Light, (B) Mode, (C) Set, (D) Start.
Time & Date Setting
- In Normal time Mode, press the [D] key to toggle between 12H and 24H format. 'P' indicates 12H format (PM).
- In Normal time Mode, hold the [C] key until the minutes start flashing to enter Time & Date setting Mode.
- Press the [B] key to select the item to set: Hours, Minutes, Year, Month, Date.
- Press the [D] key to adjust the selected data.
- Press the [C] key to exit the setting.
Alarm ON/OFF
- In Alarm Mode, press the [C] key to turn the alarm function ON or OFF.
- An indicator symbol (e.g., ?) appearing on the display means the ALM function is ON. Absence of the symbol means the alarm is OFF.
- When the alarm is chiming, the indicator symbol will flash, and the alarm will sound for 10 seconds. Press any key to stop the alarm.
Alarm Setting
- In Alarm Mode, hold the [C] key until the alarm hours start flashing to enter Alarm setting Mode.
- Press the [B] key to select the item to set: Alarm Hour, Alarm Minute, Month, Date.
- Press the [D] key to adjust the selected data.
- When setting the Alarm Hour, pay attention to the AM/PM indicator.
- When setting the Alarm Month and Date: if specific Month and Date values are set, the alarm will sound on that specific Month and Date. If no Month or Date is set, the Month&Date alarm function is OFF.
- If the Alarm function is turned ON, the alarm indicator symbol will be visible in all modes.
- Press the [C] key to exit the setting.
Chronograph Functions
In Normal Mode, press the [B] key twice to enter Chronograph Mode.
- Press [D] to start the chronograph.
- Press [D] again to suspend (pause) the chronograph.
- Press [D] again to continue.
- Press [D] to suspend again.
- When suspended, press the [C] key to reset the chronograph to 0:00:00.
For split timing in Chronograph mode:
- Press [D] to start.
- Press [C] to enter split function mode. The [SPL indicator] will appear.
- Press [C] again to display the first recorded split time. The second timing group continues in the background.
- Press [C] again to continue the second group's timing.
- Press [C] again to read the second group's recorded split time.
- When the final split group is finished, press [D] to stop the SPL function.
- Press [C] to read the final group's total (SUM) record.
- Press [C] again to clear all records to zero.
Flow description: From Chronograph Mode, press [D] to start, then [D] to suspend. From suspended state, press [C] to continue, or [C] to SPL. From SPL, press [C] to get the first record, then [C] to continue. After finishing splits, press [D] to stop SPL, then [C] to read SUM, or [C] to reset to zero.
Second Time Setting
- In Second Time Mode, the [DT indicator] will be shown.
- Hold the [C] key until the hour digits start flashing to enter DT time setting Mode.
- Press the [B] key to select the item to set: Hours or Minutes.
- Press the [D] key to adjust the selected data.
- Press the [C] key to exit the setting.
Count Down Setting
- In Count Down Mode, the [TR indicator] will be shown.
- Hold the [C] key until the hour digits start flashing to enter TR time setting Mode.
- Press the [B] key to select the item to set: TR Hours or TR Minutes.
- Press the [D] key to adjust the selected data.
- Press the [C] key to exit the setting.
- Press the [D] key to start the countdown.
- Press [D] again to suspend (pause) the countdown.
- Press [D] again to resume the countdown.
- After suspending the countdown, press the [C] key to stop the countdown function and return to the previously set countdown time.
- While the countdown is running, press the [B] key to return to Normal Time Mode, with the countdown operating in the background.
- The countdown time can be set between 1 minute and 24 hours. To set a 24-hour countdown, set the time to 0:00:00.
- After the countdown finishes (reaches 0:00:00), the watch will chime for 15 seconds. Press any key to stop the chime and return to the countdown time setting.