DocumentDocumentHID Long Range Reader Wiring Connection Addendum The HID Long Range Reader connects to an indicator through a Wiegand Converter Box. INDICATOR RS-232 WIEGAND CONVERTER BOX Figure 3 on page 2 Figure 1. HID Long Range Reader Wiring Schematic HID LONG RANGE READER Table 1 HID Terminal Description P1-1 Beeper Input (BEEP) P1-2 LED Input (GRN P1-3 Ground (GND) P1-4 +VDC P1-5 Unused (DRAIN) P1-6 LED Input (RED) P1-7 Hold Input (HOLD) Wiegand Terminal HID Terminal Description GND +V - P2-1 GPIO4 (RS485-Y / TXA) P2-2 GPIO3 (RS485-Z / TXB) P2-3 Wiegand Data 0 / Data (DATA0/DATA) P2-4 Wiegand Data 1 / Clock (DATA1/CLK) P2-5 Open Collector Output / Tamper (OC/TMPR) P2-6 GPIO2 (RS485 - RX8) P2-7 GPIO1 (RS485-RXA) Table 1. HID Long Reader Connections Wiegand Terminal DATA 0 DATA 1 - September 18, 2024 1 2 P2 3 4 5 6 7 1 2 P1 3 4 5 6 7 Figure 2. HID Long Range Reader Wiring PN 225932 Rev A HID Long Range Reader Wiring Connections CUSTOMER SUPPLIED 120 VAC GROUND HOT NEUTRAL HID READER RS-232 COMMUNICATIONS +V GND DATA 1 DATA 0 RX GND 10 Figure 3. Wiegand Converter Box Wiring Diagram © Rice Lake Weighing Systems Content subject to change without notice. 230 W. Coleman St. · Rice Lake, WI 54868 · USA USA: 800-472-6703 · International: +1-715-234-9171 September 18, 2024 www.ricelake.com PN 225932 Rev A