User Manual for GUADARRAMA FLOW models including: TA, TB, TC, TA Turbine Flowmeter, Turbine Flowmeter, Flowmeter
– G-Flow Meters
File Info : application/pdf, 14 Pages, 1,001.46KB
DocumentDocumentManual de operación Turbinas TURBINE FLOWMETER USER MANUAL TA, TB AND TC GUADARRAMA FLOW Flowmeters and flow measurement technologies. Excellence in precision and repeatability. Made in Spain since 1972. 1 Manual de operación Turbinas Index VERY IMPORTANT.....................................................................................................................................ii 1. General information ........................................................................................................................ 3 1.1. Measuring principle................................................................................................................. 3 2. Equipment Description.................................................................................................................... 4 2.1. Description and dimensions of the turbine flowmeters ......................................................... 4 2.1.1. TA Model ......................................................................................................................... 4 2.1.2. TB Model ......................................................................................................................... 5 2.1.3. TC Model ......................................................................................................................... 6 2.2. Transmitters ............................................................................................................................ 7 3. Installation....................................................................................................................................... 8 3.1. Mechanical installation ........................................................................................................... 8 3.1.1. Laminar Flow ................................................................................................................... 8 3.1.2. Always with liquid.......................................................................................................... 10 3.1.3. Avoid air passage........................................................................................................... 10 3.1.4. Other recommendations ............................................................................................... 10 4. Electrical connection ..................................................................................................................... 11 4.1. CEB01C Transmitter............................................................................................................... 11 4.1.1. NPN PNP open collector pulse output........................................................................ 11 4.2. CEB01MA transmitter............................................................................................................ 12 4.2.1. 4 20 mA analog output. .............................................................................................. 12 5. Contact .......................................................................................................................................... 13 i Turbine Flowmeter User Manual VERY IMPORTANT MECHANICAL INSTALLATION · A FILTER between 0.5mm and 1mm mesh must be installed in front of the flowmeter to protect it. Failure to install this filter can cause major damage to the equipment. This filter must be installed following the minimum flow meter inlet length indications to maintain laminar flow. · The indications described in the user manual must be followed. ELECTRICAL INSTALLATION. Only for models with power supply with pulse output. · The power supply supplying voltage to the flowmeter: o It must not exceed 30 Vdc or be less than 12 Vdc. o It must not supply INDUCTIVE LOADS (Coils, solenoid valves, contactors, etc.). · The polarity of the power supply cannot be reversed. · The pulse output does not support loads greater than 100 mA. · Power cables (Greater than 110 Vac) and Data (Pulse, analog, etc.) must go through separate conduits. These turbine flowmeters have a magnetic pulse sensor to collect the rotation of each blade of the propeller inside the measuring tube. If the flowmeter has a strong electromagnetic field nearby that comes from an electric motor or other element such as a transformer, the pulse pickup may be influenced by this electromagnetic field. The pulse cable must go through signal channeling, never power and this must be shielded with one end of this mesh to ground. Nor can the excess cable be wound making a coil. The fluid cannot carry air, since the flow meter would measure this air and the liquid. ii 1. General information Manual de operación Turbinas 1.1. Measuring principle Turbine flowmeters are equipped with a propeller that rotates when the flow circulates inside it. The rotation speed is proportional to the flow rate, so once the speed is known, the flow rate can be determined. To know this, a sensor is used that generates a pulse every time a propeller blade passes in front of it. In this way, a train of pulses is obtained whose frequency allows the flow rate to be determined. 3 2. Equipment Description Turbine Flowmeter User Manual 2.1. Description and dimensions of the turbine flowmeters 2.1.1. TA Model Model Temperature (°C) Standard Pressure (bar) Standard Flow Rate (L/h) Min. Max. Standard Resolution Pulses/liter (approx.) Materials Impeller Body Connections Dimensions (mm) Clamp connection B A C CEB01C CEB01MA CEB09BV/SI/SIA TA15 90 40 300 3.000 890 AISI 2205 AISI 316 DN15 144 135 110 190 34 Weight (kg) Standard 1 4 2.1.2. TB Model Turbine Flowmeter User Manual Temperature Pressure Model (°C) (bar) Standard Standard TB32 90 40 TB40 90 40 TB50 90 40 TB80 90 40 Flow Rate (L/h) Min. Max. 1.000 12.000 2.000 20.000 3.000 40.000 5.000 100.000 Standard Resolution Materials Pulses/liter Impeller Body (approx.) Flanges AISI AISI AISI 150 2205 316 304 AISI AISI AISI 69 2205 316 304 AISI AISI AISI 31 2205 316 316 AISI AISI AISI 11 2205 316 304 Connections Dimensions (mm) DIN EN-1092-1 Flanges DN32 PN-40 DN40 PN-40 DN50 PN-40 DN80 PN-40 A CEB01C 200 140 200 145 200 150 200 165 B CEB01MA 115 120 125 140 CEB09BV/SI/SIA 195 200 205 220 Weight (kg) Standard 5 7 9 15 5 2.1.3. TC Model Turbine Flowmeter User Manual Temperature Pressure Model (°C) (bar) Standard Standard Flow Rate (L/h) Min. Max. Standard Resolution Materials Pulses/liter Impeller Body (approx.) TC25 90 AISI AISI 25 800 8.000 230 2205 316 TC32 90 AISI AISI 25 1.000 12.000 150 2205 316 TC40 90 AISI AISI 25 2.000 20.000 72 2205 316 TC50 90 AISI AISI 25 3.000 40.000 31 2205 316 TC80 90 25 5.000 100.000 11 AISI AISI 2205 316 Connections DIN11851 Sanitary Thread DN25 DN32 DN40 DN50 DN80 Dimensions (mm) Weight (kg) B A Standard CEB01C CEB01MA CEB09BV/SI/SIA 200 135 110 190 2 200 140 115 195 3 200 145 120 200 3 200 150 125 205 4 200 165 140 220 5 6 Turbine Flowmeter User Manual 2.2. Transmitters Transmitters are electronic devices that are used to calculate, using the pulses/liter factor, the volume of liquid that passes through the Turbine flowmeter. Depending on the model chosen, there is the option of having local indication (display), pulse output, analog output, or all combined. CEB01C CEB01MA CEB09 (BV/BVSI/BVSIA) - CEB01C: NPN PNP transistor output, without local indication. - CEB01MA: Analog (4 20 mA) output, without local indication. - CEB09BV: Local Indication of: o Total Volume: Total liters that have passed through the equipment since the beginning of its operation, with a resolution of 8 digits. o Partial Volume: Total liters that have passed through the equipment since the last reset, with a resolution of 7 digits. o Volumetric Flow: Instantaneous flow rate that circulates through the flowmeter, with a resolution of 5 digits. - CEB09BVSI: Local indication and NPN PNP transistor output. - CEB09BVSIA: Local indication, NPN PNP transistor and analog (4 20 mA) output. Model Power Output Supply Indication Pulses 4 20 mA CEB01C 24 Vdc X CEB01MA 24 Vdc X CEB09BV Internal X CEB09BVSI Internal X X CEB09BVSIA 24 Vdc X X X Material Aluminum Stainless Steel Aluminum Aluminum Aluminum Description NPN - PNP transistor output, without local indication 4 20 mA output, without local indication Local Indication, without outputs NPN PNP transistor output and local indication NPN PNP transistor and 4 20 mA output and local indication Note: CEB09BV/SI/SIA transmitters have a specific user manual. 7 3. Installation Turbine Flowmeter User Manual 3.1. Mechanical installation Stainless steel turbine flowmeters accurately measure when correct mechanical installation is performed. The recommendations that are exposed in this section, try to achieve the following objectives: · Laminar flow: The liquid that passes through the equipment must do so in a laminar regime, that is, not turbulent. · Always with liquid: The flowmeter must always be filled with liquid. · Avoid the passage of air: The passage of air, or other gas through the flowmeter must be avoided. Caution: A 0.5-1mm mesh FILTER must be installed in front of the flowmeter to protect it. Failure to install this filter can cause major damage to the equipment. This filter must be installed following the minimum flow meter inlet length indications to maintain laminar flow. 3.1.1. Laminar Flow Straight sections. It is essential to place a section of straight pipe with the same internal diameter as that of the flow meter and, as a general rule, with a minimum length of 5 times the diameter at the outlet and 10 times the diameter at the inlet. Reductions. If the diameter of the pipe is different from that of the flowmeter, concentric reductions must be placed before and after the indicated straight sections. Curved sections. In front of or behind these straight tubes other elements or curved sections can be placed. 8 Turbine Flowmeter User Manual Valves. Manual valves must be placed behind the flow meter. If you want to put them in front of it, you have to increase the straight section to 30 D. This is because, if a valve is left half open, the laminar flow of the liquid is greatly altered. Unions with the pipe. The unions of the flowmeter with the pipes are critical points where turbulence can occur, affecting the precision of the equipment, if they are not carried out properly. · As already indicated, the internal diameter of the pipe must be equal to that of the flow meter. · Furthermore, the union fitting and gasket must not disturb the flow of the liquid. This point may be particularly important in the case of flanged junction TB turbine flowmeters. Gasket 1 - Inner diameter of gasket and flange 2 - Internal diameter of flowmeter 3 - Internal diameter of the pipe It is very important that the gasket is centered and that it has the same internal diameter to avoid turbulence at the inlet of the flowmeter. It is recommended to use self-centering gaskets such as: · Gaskets whose outside diameter rests on the inside of the bolts. · Gaskets with dimensions equal to the flanges, including their holes. 9 Turbine Flowmeter User Manual 3.1.2. Always with liquid The flow meter can be mounted in the pipeline in a VERTICAL or HORIZONTAL POSITION, but it must always be avoided that the flow meter can remain empty. A flowmeter should never be installed in an open discharge. 3.1.3. Avoid air passage The passage of air or any gas through the flowmeter must be avoided, otherwise a measurement error would be made. If it cannot be avoided, a degasser or any other system must be installed that prevents air from passing through the equipment. In mobile installations, the air hose must be purged before reaching the flow meter. Important. The passage of compressed air, steam or any other gas under pressure can seriously damage the turbine flow meter. 3.1.4. Other recommendations The flow meter must not be mounted next to the electric motor of a pump. It must be moved a minimum of 50 cm away. The fluid should not back up, otherwise it would count it positively. If there is a risk that this circumstance could occur, a non-return valve must be fitted. In lines with very hot liquids, if the flowmeter is installed in a horizontal line, rotate it 90 degrees so that the transmitter is not above the pipe, as the internal electronics could overheat. 10 4. Electrical connection Turbine Flowmeter User Manual 4.1. CEB01C Transmitter 4.1.1. NPN PNP open collector pulse output PNP Connection NPN Connection 11 4.2. CEB01MA transmitter 4.2.1. 4 20 mA analog output. CEB01MA Turbine Flowmeter User Manual · Passive 4 20 mA output · Maximum load: 500 ohms 12 Turbine Flowmeter User Manual 5. Contact For any problem you may encounter or service you need, do not hesitate to contact the G - Flow offices. Telephone: +34 916378174 / +34 916378175 E-mail: serviciotecnico@g-flow.com Address: Office Laboratory Factory Calle Justina Velasco Martín 2, Pol. Ind. Los Llanos 28260 Galapagar Madrid. 13