Introduction
Cooling is essential to modern IT environments, but conventional perimeter and raised-floor cooling systems are expensive to operate and difficult to install, especially when retrofitted to existing facilities and smaller spaces. Whether used for primary or supplemental cooling, SmartRack air conditioning units offer an efficient, flexible, manageable alternative that reduces costs and simplifies installation.
Plug-and-Play Cooling Engineered for IT Environments
SmartRack air conditioning units are designed for the needs of the IT department. IT staff can install them without outside assistance, quickly reconfigure them to respond to new challenges and manage them over the network like other IT resources.
Key Features:
- COMPACT & EFFICIENT COOLING: SmartRack air conditioning units pack powerful cooling into a compact footprint. They help prevent equipment shutdowns, malfunctions, and failures caused by overheating and temperature fluctuations. They also dehumidify and filter air. Close-coupled cooling delivers cold air where it's actually needed instead of wasting energy where it isn't.
- SIMPLIFIED INSTALLATION: Units plug into standard NEMA wall outlets and fit almost anywhere. Installation is do-it-yourself simple, with no need for disruptive construction projects, external condensers, refrigerant piping, plumbing, raised floors, or costly specialists.
- UNATTENDED OPERATION: Units automatically restart after power outages with last-used settings and support automated on/off scheduling. They also include built-in evaporators to prevent condensation from accumulating, so you won't need to empty a water collection tank or install a floor drain.
- FLEXIBILITY: Retrofit, reconfigure, or expand cooling on the fly to handle new equipment, increasing power density and troublesome hot spots. Direct area cooling through adjustable louvers or use flexible output ducts to focus cold air where it's needed most. Modular cooling means you're always ready for change, which is the one constant in every IT environment.
- RESILIENCE: With cooling distributed across multiple units, a single problem won't disable your data center. Engineered to meet the rigorous requirements of high-availability IT environments, SmartRack air conditioning units are also less likely to have problems in the first place.
- MANAGEABILITY: All units support network management, allowing you to monitor temperatures, change settings, define threshold warnings, receive alerts, access logs, and automate operation via SNMP, Web, SSH, or telnet.
Visual Description: The SRCOOL7KRM is highlighted as the first rack-mounted air conditioning unit designed for IT cooling. Images depict a compact unit for rack mounting, a portable unit with a built-in output vent for area cooling, a portable unit with flexible ducts for focused cooling, a close-up of a control panel with a digital display and diagnostic LEDs, and a screenshot of the PowerAlert software for network management.
Tripp Lite's cooling solutions are recognized for their quality, with an award noted: "Tripp Lite's award-winning cooling is #1!*" [*Top channel vendor for portable AC units per NPD.]
Features & Specifications
Tripp Lite SmartRack Air Conditioning Units offer a range of models with varying cooling capacities and form factors.
Model | SRCOOL7KRM | SRCOOL12K | SRCOOL18K | SRCOOL24K | SRCOOL33K |
---|---|---|---|---|---|
Cooling Capacity | 7,000 BTU/hr. (2 kW) | 12,000 BTU/hr. (3.5 kW) | 18,000 BTU/hr. (5.275 kW) | 24,000 BTU/hr. (7 kW) | 33,000 BTU/hr. (9.7 kW) |
Form Factor | 8U Rack-Mounted Unit (4-Post Rack-Bottom Mounting) | Compact Portable Unit | Rack-Width Portable Unit | Rack-Width Portable Unit | 42U Rack-Width, Row-Based Unit |
Recommended Applications | 1. Rack Cooling 2. Area Cooling(1) |
1. Rack Cooling 2. Spot Cooling 3. Area Cooling 4. Backup Cooling |
1. Rack Cooling 2. Area Cooling 3. Backup Cooling |
1. Rack Cooling 2. Area Cooling 3. Backup Cooling |
1. Rack Row Cooling 2. Area Cooling |
Dimensions (H x W x D) | 13.9 x 17.35 x 22.52 in. (35.3 x 44.1 x 57.2 cm) |
30.63 x 11.81 x 19.88 in. (77.8 x 30 x 50.5 cm) |
38.2 x 20.5 x 21.7 in. (97 x 52.1 x 55.1 cm) |
38.2 x 20.5 x 21.7 in. (97 x 52.1 x 55.1 cm) |
78.5 x 23.63 x 43 in. (199.4 x 60 x 109.2 cm) |
Unit Weight | 61.6 lb. (27.9 kg) | 73.9 lb. (33.5 kg) | 175.37 lb. (79.5 kg) | 175.37 lb. (79.5 kg) | 700 lb. (317.5 kg) |
Rolling Casters | No | Yes | Yes | Yes | Yes |
AC Input | 120V, 60 Hz | 120V, 60 Hz | 208/240V, 60 Hz | 208/240V, 60 Hz | 200-240V, 50/60 Hz |
Plug Type | NEMA 5-15P | NEMA 5-15P | NEMA L6-20P | NEMA L6-20P | NEMA L6-30P |
Cord Length | 7 ft. (2.1 m) | 6 ft. (1.8 m) | 6.56 ft. (2 m) | 6.56 ft. (2 m) | 10 ft. (3 m) |
Refrigerant Type | R410A | R410A | R410A | R410A | R410A |
Refrigerant Capacity | 18.7 oz. (530 g) | 22.4 oz. (635 g) | 36.68 oz. (1.04 kg) | 42.33 oz. (1.2 kg) | 134.04 oz. (3.8 kg) |
Dehumidifying Capacity(2) | 1.25 l/hr. (.33 gal./hr.) | 2.5 l/hr. (.66 gal./hr.) | 47.3 l/hr. (12.5 gal./hr.) | 56.8 l/hr. (15 gal./hr.) | 9.46 l/hr. (2.5 gal./hr.) |
Air Circulation | 198 CFM (337 m3/hr.) | 329 CFM (560 m3/hr.) | 634 CFM (1,077 m3/hr.) | 634 CFM (1,077 m3/hr.) | 1,200 CFM (2,039 m3/hr.) |
Nominal Input Current | 8.5A | 10.5A | 10.5A | 13.5A | 24A |
Compressor Type | Rotary | Rotary | Rotary | Rotary | Variable-Speed(3) |
Audible Noise | 57 dB | 57 dB | 59 dB | 65 dB | 75 dB |
Remote Management | Add SRCOOLNET2 | Add SRCOOLNET | Add SRCOOLNET2 | Included | Modbus Card Included(4) |
External Sensor(5) | Included with SRCOOLNET2 | Included with SRCOOLNET | Included with SRCOOLNET2 | Included | Add ENVIROSENSE(6) |
Close-Coupled Cooling | Yes | Yes | Yes | Yes | Yes |
Ozone-Friendly Refrigerant | Yes | Yes | Yes | Yes | Yes |
Automatic Restart | Yes | Yes | Yes | Yes | Yes |
On/Off Scheduling | Yes | Yes | Yes | Yes | Yes |
Condensation Evaporator | Yes | Yes | Yes | Yes | Yes |
Optional-Use Condensation Drain(7) | Yes | Yes | Yes | Yes | Yes |
Cooling Output Vent | Yes | Yes | Yes | Yes | Yes |
Flexible Cooling Output Duct | No | Yes | Yes | Yes (2 Ducts) | No |
Flexible Exhaust Duct | Add SRCOOL7KDUCT | Yes | Yes (2 Ducts) | Yes (2 Ducts) | Yes (2 Ducts)(8) |
Self-Contained (Internal Condenser) | Yes | Yes | Yes | Yes | Yes |
Installation Kit(9) | Included(10) | Included | Included | Included | Included(11) |
Standards | UL 484 (ETL), CSA, NOM, EIA/ECA-310-E, RoHS | UL 484 (ETL), CSA, RoHS | UL 484 (ETL), CSA, NOM, RoHS | UL 484 (ETL), CSA, NOM, RoHS | UL 484 (ETL), CSA, FCC Class A, RoHS |
Certifications vary with model.
Notes:
(1) Add SRCOOL7KDUCT for area cooling and other applications requiring an exhaust duct.
(2) Measured at 86° F (30° C), 80% RH.
(3) Variable-speed, DC-inverter-driven compressor saves energy and limits inrush current to 5A.
(4) Also supports SNMPWEBCARD, which replaces the included Modbus card.
(5) Sensor connects with 12 ft. (3.66 m) cord and reports temperature, humidity, and status of dry contact closure inputs.
(6) Requires SNMPWEBCARD.
(7) Using the condensation drain instead of the condensation evaporator may be required in high-humidity conditions or dehumidification applications.
(8) Also includes 2 intake ducts.
(9) Includes all parts required for standard installation. May require additional tools. Alternate applications may require additional parts.
(10) Add SRCOOL7KDUCT for applications requiring an exhaust duct.
(11) Add SRCEILINGADAPT to facilitate connection of ducts to dropped ceiling.
For assistance, visit www.tripplite.com/cooling or contact the application team at 773.869.1236 or solutions@tripplite.com.
Other Cooling Solutions
Tripp Lite offers a variety of airflow management and heat removal solutions to help prevent downtime, increase efficiency, and reduce operating costs. SmartRack premium rack enclosures allow abundant front-to-rear airflow and support high-density cable managers to help prevent cable clutter from obstructing rack airflow.
Airflow Optimization & Heat Removal Solutions
- SR1UBRUSH: 1U Cable Pass-Through Panel with Brush Strip
- SR1UPANEL10: Toolless 1U Blanking Panel Kit (10 Pieces)
- SR1UPANEL50: Toolless 1U Blanking Panel Kit (50 Pieces)
- SR1UPANEL200: Toolless 1U Blanking Panel Kit (200 Pieces)
- SRBRUSHWM: Brush Strip Plate for Wall-Mount Cabinets
- SRFAN1U: 1U Fan Tray with 3 Fans
- SRFAN3U: 3U Fan Panel with 3 Fans
- SRFANROOF: Roof-Mounted Fan Panel with 6 Fans for Floor-Standing Rack Enclosures
- SRFANWM: Roof Fan Kit with 2 Fans for Wall-Mount Cabinets
- SRGASKET: Rack Enclosure Airflow Optimization Kit
- SRSKIRT: Rack Enclosure Skirt Kit
- SRSKIRT3: Rack Enclosure Skirt Kit for 3-inch Casters
- SRSWITCHDUCT: Rack Enclosure Side Airflow Ducting Kit for Network Switches
- SRTHERMDUCT: Thermal Duct Kit for Standard 42-48U Rack Enclosures
- SRXUPANEL: 4-Size Blanking Panel Kit (1U, 2U, 4U and 8U)
Visual Description: The SRTHERMDUCT thermal duct kit is described as isolating and removing heat like a chimney. Toolless 1U blanking panels are shown preventing warm air from recirculating inside rack enclosures.
Rack Cable Managers
- SRCABLEDUCT1U: 1U Horizontal Cable Manager
- SRCABLEDUCTVRT: 6 ft. Vertical Cable Manager
- SRCABLEDUCT1UHD: 1U High-Capacity Horizontal Cable Manager
- SRCABLEDUCT2UHD: 2U High-Capacity Horizontal Cable Manager
- SRCABLERING1U: 1U Horizontal Cable Manager, Flexible Ring
- SRCABLERING2U: 2U Horizontal Cable Manager, Flexible Ring
- SRCABLERINGVRT: 6 ft. Vertical Cable Manager, Flexible Ring
- SRCABLETRAY1U: 1U Horizontal Cable Management Tray
- SRCABLEVRT3: High-Capacity Vertical Cable Manager, 3 in. Wide
- SRCABLEVRT6: High-Capacity Vertical Cable Manager, 6 in. Wide
- SRCABLEVRT12: High-Capacity Vertical Cable Manager, 12 in. Wide
Tripp Lite offers more than 3,500 different IT solutions. See the full selection at www.tripplite.com.
Certifications: Products are tested for compliance with standards including [ETL Certified], [CSA Certified], [NOM Certified], [RoHS Compliant], [FCC Class A], and [ISO 9001 Certified Quality Systems].
Tripp Lite World Headquarters: 1111 W. 35th Street, Chicago, IL 60609 USA.