DMP Wireless Access Control: 1134 Module & Assa Abloy Integration Guide

WIRELESS ACCESS CONTROL SUPPORT

Application Note

Introduction

DMP offers support for access control solutions in wireless door applications. This includes connecting the DMP 1134 Wireless Access Control Module to an XR Series or XT75 panel or using Assa Abloy wireless hubs and locks with DMP products. Each application can be designed to fit specific installation needs. This application note explains use cases for wireless door support and provides information on how to choose the best option for specific installation scenarios.

DMP 1134 WIRELESS SUPPORT

This application allows you to wire the 1134 module to the magnetic lock or door strike, then wirelessly connect the 1134 to the panel.

This setup works well in installation locations where it is difficult to run long lengths of wire from the module to the panel. This option is beneficial when doors can be easily modified to run cable or when you need to use wired locks for reliability or code compliance. Refer to Figure 1.

You can then connect a reader to the 1134 so users can use their access cards, credentials, or Digital Keys to unlock doors.

Components Required:

  • DMP XT75 Control Panel or XR Series Control Panel
  • DMP 1134 Series Wireless Access Control Module
  • Wired door lock or strike
  • Reader

Figure 1: 1134 Wireless Support illustrates a setup where a wired door strike or magnetic lock connects to the DMP 1134 Module, which then establishes a wireless connection to the DMP Panel.

ASSAY ABLOY WIRELESS SUPPORT

This application allows you to wire the DMP 734 Access Control Module or DMP X1 Series Controller to the panel and Aperio Communication Hub, then wirelessly pair the hub and door lock together.

This setup works well in installation locations where it is difficult to run wire from the module to the door, such as installations where doors are older or have frameless glass. This option provides centralized wiring with no wiring at the door when doors cannot be easily modified to run cable. Refer to Figure 2.

Users can then use their access cards, credentials, or Digital Keys to scan the reader and unlock doors. To use NFC compatible readers with this application, download and use the Aperio Programming Application.

Components Required:

  • DMP XT75 Control Panel or XR Series Control Panel
  • DMP X1 Series Controller or DMP 734 Series Access Control Module
  • Aperio AH20/AH30 (Gen5) Hub
  • Assa Abloy wireless door lock and reader

Figure 2: Aperio Wireless Support depicts a system where an Assa Abloy Wireless Door Lock connects wirelessly to an Aperio Communication Hub, which is wired to a DMP 734 Module, which in turn connects wirelessly to the DMP Panel.

REFERENCE DOCUMENTS

For more information, refer to the following documentation:

PDF preview unavailable. Download the PDF instead.

v1 Adobe PDF Library 17.0 Adobe InDesign 20.5 (Windows)

Related Documents

Preview XR Series Version 253 Firmware Update: Enhanced OSDP Support
Digital Monitoring Products (DMP) announces the XR Series Version 253 firmware update for XR150/XR550 panels, introducing OSDP support for 7873 Series Touchscreen Keypads and 734 Access Control Modules. Details configuration steps and download information.
Preview DMP 734 Access Control Module Quick Start Guide
This guide provides essential steps for installing and wiring the DMP 734 Access Control Module, covering mounting, lock wiring, zone connections, card reader setup, and power supply. It references the full installation manual for detailed programming.
Preview X1 Series Output Expansion Module Quick Start Guide | DMP
Concise guide for installing and configuring the DMP X1 Series Output Expansion Module (X1-OUT-EXP) for access control systems. Covers mounting, addressing, wiring, programming, and testing.
Preview DMP 7800 Series Graphic Touchscreen Keypads: Firmware Version 209 Update
Details the Version 209 firmware update for DMP 7800 Series Graphic Touchscreen Keypads, including OSDP support enhancements and keypad reset fixes. Information on obtaining the latest firmware from DMP.
Preview DMP 734 Access Control Module Installation and Programming Guide
This guide provides detailed instructions for the installation and programming of the DMP 734 Access Control Module, covering features, wiring, setup, and troubleshooting.
Preview 7000 Series Thinline and Aqualite Keypad Installation and Programming Guide
This guide provides comprehensive instructions for the installation and programming of the 7000 Series Thinline and Aqualite Keypads from Digital Monitoring Products (DMP). It covers keypad features, character entry, panic key options, user menus, and detailed wiring instructions for various models.
Preview 1100T Wireless Translator Installation Guide - DMP
Installation guide for the DMP 1100T Wireless Translator, detailing setup, programming, power, mounting, and specifications for integrating non-DMP wireless transmitters with DMP alarm panels.
Preview DMP XT75 Firmware Update Version 253 Release Notes
Technical update for DMP XT75 Control Panels, detailing firmware version 253 features including Remote Key, Network Programming Port, and Wi-Fi communication improvements. Learn how to obtain the latest firmware.