EXTRON PVT RGB D (01)
PVT Series
PoleVault Twisted Pair Input Wallplates (Decora® and AAP models)

User Guide
PoleVault® Wallplates

PVT CV D, PVT RGB D Plus, PVT RGB D PVT CV AAP, and PVT RGB AAP

https://manual-hub.com/

68-1259-01 Rev. D 07 12

Precautions

SafetyInstructions·English
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
Caution
Read Instructions·Read and understand all safety and operating instructions before using the equipment. RetainInstructions·The safety instructions should be kept for future reference. FollowWarnings·Follow all warnings and instructions marked on the equipment or in the user information. AvoidAttachments·Do not use tools or attachments that are not recommended by the equipment
manufacturer because they may be hazardous.
ConsignesdeSécurité·Français
Ce symbole sert à avertir l'utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l'exploitation et la maintenance (réparation). Ce symbole sert à avertir l'utilisateur de la présence dans le boîtier de l'appareil de tensions dangereuses non isolées posant des risques d'électrocution.
Attention
Lirelesinstructions·Prendre connaissance de toutes les consignes de sécurité et d'exploitation avant d'utiliser le matériel.
Conserverlesinstructions·Ranger les consignes de sécurité afin de pouvoir les consulter à l'avenir. Respecterlesavertissements·Observer tous les avertissements et consignes marqués sur le matériel ou
présentés dans la documentation utilisateur. Eviterlespiècesdefixation·Ne pas utiliser de pièces de fixation ni d'outils non recommandés par le fabricant
du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen·Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben. Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen ·BevorSiedasGerätzumerstenMalverwenden,solltenSiealleSicherheits-und Bedienungsanleitungengenaudurchlesenundverstehen.
Aufbewahren der Anleitungen ·DieHinweisezurelektrischenSicherheitdesProduktessolltenSie aufbewahren,damitSieimBedarfsfalldaraufzurückgreifenkönnen.
Befolgen der Warnhinweise ·BefolgenSiealleWarnhinweiseundAnleitungenaufdemGerätoderinder Benutzerdokumentation.
Keine Zusatzgeräte ·VerwendenSiekeineWerkzeugeoderZusatzgeräte,dienichtausdrücklichvomHersteller empfohlenwurden,dadieseeineGefahrenquelledarstellenkönnen.
Instruccionesdeseguridad·Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos. Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leerlasinstrucciones·Leer y analizar todas las instrucciones de operación y seguridad, antes de usar el equipo.
Conservarlasinstrucciones·Conservar las instrucciones de seguridad para futura consulta. Obedecerlasadvertencias·Todas las advertencias e instrucciones marcadas en el equipo o en la
documentación del usuario, deben ser obedecidas. Evitarelusodeaccesorios·No usar herramientas o accesorios que no sean especificamente recomendados
por el fabricante, ya que podrian implicar riesgos.
 · 



 ·  ·  ·  ·

Warning
Powersources·This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Powerdisconnection·To remove power from the equipment safely, remove all power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Powercordprotection·Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them.
Servicing·Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slotsandopenings·If the equipment has slots or holes in the enclosure, these are provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithiumbattery·There is a danger of explosion if battery is incorrectly replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Avertissement
Alimentations·Ne faire fonctionner ce matériel qu'avec la source d'alimentation indiquée sur l'appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n'essayez pas de la contourner ni de la désactiver.
Déconnexiondel'alimentation·Pour mettre le matériel hors tension sans danger, déconnectez tous les cordons d'alimentation de l'arrière de l'appareil ou du module d'alimentation de bureau (s'il est amovible) ou encore de la prise secteur.
Protectionducordond'alimentation·Acheminer les cordons d'alimentation de manière à ce que personne ne risque de marcher dessus et à ce qu'ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance·Faire exécuter toutes les interventions de réparation-maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l'utilisateur. Afin d'éviter tout danger d'électrocution, l'utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l'ouverture ou le retrait des couvercles risquent de l'exposer à de hautes tensions et autres dangers.
Fentesetorifices·Si le boîtier de l'appareil comporte des fentes ou des orifices, ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
LithiumBatterie·Il a danger d'explosion s'll y a remplacment incorrect de la batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen·DiesesGerätsolltenurüberdieaufdemProduktangegebeneStromquellebetriebenwerden. DiesesGerätwurdefüreineVerwendungmiteinerHauptstromleitungmiteinemgeerdeten(neutralen)Leiter konzipiert.DerdritteKontaktistfüreinenErdanschluß,undstellteineSicherheitsfunktiondar.Diesesolltenicht umgangenoderaußerBetriebgesetztwerden.
Stromunterbrechung ·UmdasGerätaufsichereWeisevomNetzzutrennen,solltenSiealleNetzkabelausder RückseitedesGerätes,ausderexternenStomversorgung(fallsdiesmöglichist)oderausderWandsteckdose ziehen.
Schutz des Netzkabels ·Netzkabelsolltenstetssoverlegtwerden,daßsienichtimWegliegenundniemand darauftretenkannoderObjektedarauf-oderunmittelbardagegengestelltwerdenkönnen.
Wartung ·AlleWartungsmaßnahmensolltennurvonqualifiziertemServicepersonaldurchgeführtwerden.Die internenKomponentendesGerätessindwartungsfrei.ZurVermeidungeineselektrischenSchocksversuchen SieinkeinemFall,diesesGerätselbstöffnen,dabeimEntfernenderAbdeckungendieGefahreines elektrischenSchlagsund/oderandereGefahrenbestehen.
Schlitze und Öffnungen ·WenndasGerätSchlitzeoderLöcherimGehäuseaufweist,dienendiesezur VermeidungeinerÜberhitzungderempfindlichenTeileimInneren.DieseÖffnungendürfenniemalsvon anderen Objekten blockiert werden.
Litium-Batterie ·Explosionsgefahr,fallsdieBatterienichtrichtigersetztwird.ErsetzenSieverbrauchteBatteriennur durchdengleichenodereinenvergleichbarenBatterietyp,derauchvomHerstellerempfohlenwird.Entsorgen SieverbrauchteBatterienbittegemäßdenHerstelleranweisungen.
Advertencia
Alimentacióneléctrica·Esteequipodebeconectarseúnicamentealafuente/tipodealimentacióneléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexióndealimentacióneléctrica·Para desconectar con seguridad la acometida de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Proteccióndelcablesdealimentación·Los cables de alimentación eléctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento·Solicitarsiemprelosserviciostécnicosdepersonalcalificado.Enelinteriorno hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranurasyaberturas·Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el sobrecalientamientodecomponentesinternossensibles.Estasaberturasnuncasedebenobstruirconotros objetos.
Bateríadelitio·Existeriesgodeexplosiónsiestabateríasecolocaenlaposiciónincorrecta.Cambiarestabatería únicamenteconelmismotipo(osuequivalente)recomendadoporelfabricante.Desacharlasbateríasusadas siguiendo las instrucciones del fabricante.

 ·    
 · 
 ·   ·  
  · 
  ·


ii

https://manual-hub.com/

FCCClassANotice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance with FCC emissions limits.
.

https://manual-hub.com/

iii

ConventionsUsedinthisGuide
In this user guide, the following are used: WARNING: A warning warns of things or actions that might cause injury, death, or
other severe consequences.
CAUTION: A caution indicates a potential hazard to equipment or data.
NOTE: A note draws attention to important information.

Copyright ©2012ExtronElectronics.Allrightsreserved.
Trademarks All trademarks mentioned in this guide are the properties of their respective owners.

https://manual-hub.com/

iv

Contents
Introduction ............................................ 1 AboutthePVTInputWallplates ....................... 1 Transmission distance................................... 1 AboutthePVTCVD .................................... 2 AboutthePVTCVAAP ................................ 2 AboutthePVTRGBD(EDID)........................ 3 AboutthePVTRGBDPlus(EDID)................. 3 AboutthePVTRGBAAP(EDID).................... 3
Installation .............................................. 5 ULSafetyRequirements ................................... 5 Important safety instructions........................ 5 InstallingthePVTCVandPVTRGBDecora models ........................................................... 6 To Install into a Mud-ring ............................. 6 ToInstallintoaWallBox .............................. 7 InstallingthePVTCVandPVTRGBAAP models ........................................................... 7
Connections and Settings ...................... 9 Front Panel Features......................................... 9 Rear Panel...................................................... 10 Output cabling........................................... 10 Rear Panel -- Features .............................. 11 EDIDMinder ................................................. 13 UsingPresetmode ..................................... 13 UsingLearnmode(availableon PVTRGBDPlusonly) ............................... 14 Final installation ............................................. 14
ReferenceMaterial ................................15 Specifications................................................. 15 Part Numbers and Accessories........................ 18 PoleVaultAVInputPlatePartNumbers....... 18 Included Parts ............................................ 18 Optional Accessories .................................. 18 AAP Optional Parts .................................... 18
https://manual-hub.com/

PVTSeries·Contents

v

https://manual-hub.com/

PVTSeries·Contents

vi

Introduction
ThesectiondiscussesbasicinformationasanintroductiontothePVTSeriesoftwistedpair AVinputwallplates. This section covers the following: · About the PVT Input Wallplates
AboutthePVTInputWallplates
TheExtronPVTSeriesPoleVault®TwistedPairInputWallplates(Decora® and Architectural Adapter Plates [AAP] models) described in this guide are a series of five cost effective twisted pairtransmitters.ThesetransmittersworkexclusivelywithPoleVault(PVS)switchers,which are twisted pair switchers with a built in power amplifier. PVTinputwallplatesarepartofasystemfordistributionofcompositevideoandstereo audio,orhighresolutionvideo(RGB)andstereoaudio,over: · ExtronEnhancedSkew-FreeTMA/VUTPcable · CAT 5e, or 6 shielded twisted pair (STP) cable · unshieldedtwistedpair(UTP)cable · foil shielded twisted pair (FTP) cable AllPVTwallplatesareremotelypoweredviathetwistedpaircablewhenconnectedtothe PoleVaultswitcher.
NOTES: PVTseriesofinputwallplatesarecompatibleONLYwithPVS(PoleVault) switchers. ForPVSswitcherinstallationandoperationinformation,refertotheguide supplied with the device.
Transmission distance
The maximum distance is determined by the frequency and resolution of the signal that is inputtothetransmitter.However,allPVTmodelsarecapableoftransmittingsignalstothe PVSswitcherifitislocatednotmorethan125feetaway.Theoptimumdistanceisbetween 50 and 75 feet. ThePVTDecoraandAAPmodelscanbemountedinULstandardwallboxeswithDecorastyle face plates or in AAP openings in wall or device face plates. The model types are as follows: PVT CV D, PVT CV AAP -- Transmit composite video and stereo audio. PVT RGB D, PVT RGB D Plus, PVT RGB AAP--Transmitcomputer(RGB)videoandstereo audio. Seethe"AboutthePVT..."sectionsinthischapterfordetails.

https://manual-hub.com/

PVTSeries·Introduction 1

AboutthePVTCVD
The PVT CV D is a wall or furniture mountable wall plate that fits any single opening Decora stylewallplate.ItcantransmitcompositevideoandstereoaudiotoanyPoleVaultswitcher. In addition, a 2-pole IR pass-through provides control connection for IR devices.

VIDEO IN

AUDIO IN

L

R

IR OUT

S G

VIDEO IN

AUDIO IN

L

R

IR OUT

S G

Figure 1. PVT CV D face and rear panels
AboutthePVTCVAAP
The PVT CV AAP fits a standard double space AAP opening and can transmit composite videoandstereoaudiotothePVSswitcher.

VIDEO IN

L

R

AUDIO IN

PVT CV

Figure 2. PVT CV AAP face and rear panels

https://manual-hub.com/

PVTSeries·Introduction 2

AboutthePVTRGBD(EDID)
The PVT RGB D (EDID) is a wall or furniture mountable model that fits any single opening Decorastylewallplate.Itcantransmitcomputer(RGB)videoandstereoaudiotothePVS switcher,andhasanIRpass-thoughporttoaprovidecontrolconnectionforDVD/VCR players, tuners, switchers, or other IR controllable devices.

AUDIO IN COMPUTER IN
S G IR OUT

AUDIO IN COMPUTER IN
S G IR OUT

G S ON 1234 5
RGB A RGB B OUT OUT

Figure 3. PVT RGB D (EDID) face and rear panels
NOTE: ForallPVTRGBDecoraandAAPmodels,twocablerunsarerequiredtocarry thevideoandaudiosignalstothePVSswitcher.
AboutthePVTRGBDPlus(EDID)
The PVT RGB D Plus (EDID) is a wall or furniture mountable model that fits any single openingDecorastylewallplate.Itcantransmitcomputer(RGB)videoandstereoaudioto the switcher with a local monitor output and audio output. In addition, a 2-pole IR passthrough provides control connection for IR devices.

GRL GS
ON 1234 5

AUDIO IN OUT COMPUTER IN
MONITOR OUT
S G IR OUT

AUDIO IN OUT COMPUTER IN
MONITOR OUT
S G IR OUT

RGB A RGB B OUT OUT

Figure 4. PVT RGB D Plus (EDID) face and rear panels
AboutthePVTRGBAAP(EDID)
The PVT RGB AAP fits a standard double height AAP opening in a wall plate or a device's frontorsecondarypanel.Itcantransmitcomputer(RGB)videoandstereoaudiotothePVS switcher. In addition, a 2-pole IR pass-through provides control connection for IR devices.

RGB A RGB B OUT OUT

1234 5

ON

IR

S

OUT

G

COMPUTER IN

AUDIO IN PVT RGB AAP

GS

Figure 5. PVT RGB AAP face and rear panels

https://manual-hub.com/

PVTSeries·Introduction 3

Extron SPK 18 - 35' Cable
Extron PCM 340 Projector Drop Ceiling Mount

UTP Cable (CAT 5/5E/6)

Extron FF 120 Flat Field Ceiling Speakers - 1 Pair
From PA system

Extron Priority Page Sensor (Optional Accessory)

Extron VoiceLift Receiver (Optional Accessory)

To PoleVault Switcher

Ceiling Mounted Paging Speaker

Extron PMK 550 Easy Installation Pole Mount Kit

Extron PVS 305SA PoleVault® Switcher

CONFIG

1

2

INPUT SELECTION

3

4

5

AUX AUDIO

INPUT

PVS 305SA PNSEIOGARNKAMAALULDIOVOMILCIEECLVIFET LPAODPNLEJOEARUVKMSAALTULT SIGNAL

SWITCHER SPEANGSINOGR

SENSITIVITY

Slotted Projector Mount Pole

Extron

PVT CV D

Composite Video

VIDEO IN

& Audio Input Wallplate

L

AUDIO IN

R

IR OUT

S G

Extron UPB 25 Universal Projector Mounting Bracket

Assistive Listening System

IR Emitter
DVD/VCR Combo
PC

AUINDIO COMPUTER

AOUUDTIO IN

MONITOR OUT

IR OUT
S G

Extron

PVT RGB D Plus (EDID)

VGA & Audio Input

Wallplate

Extron

PVT RGB D (EDID)

VGA & Audio

AUINDIO

Input Wallplate

COMPUTER IN

IR OUT S G

RS-232 to Switcher
RS-232 to Projector

ONDISPLAY OFF
VOLUME

VCR 1
DVD 2

PC

CONFIG

3

4

MLC 104 IP PLUS
Extron

MLC 104 IP Plus

VIDEO IN

Extron

MediaLink® Controller

L

AUDIO IN

R

IR OUT

PVT CV D

S G

Composite Video

& Audio Input

CHARGE

Wallplate

Extron

TCP/IP Network

ON

PWR PWR

OFF/MUTE/CHG

Computer w/ Podcasting Software

Document Camera

Camera

OFF/MUTE/CHG

ON

CHARGE

Extron
Extron VoiceLift Microphone and Charging Station (Optional Accessory)

Figure 6. Typical PVT series system application using PVT Decora and AAP transmitters with the PVS 305SA and other Extron device.

https://manual-hub.com/

PVTSeries·Introduction 4

Installation

Thesectiondiscussesthemethodofinstallation,cabling,andusingEDIDMinderofthe PVTserieswallplates.
This section covers the following: · UL Safety Requirements · Installing the Wallplates · Connections and Settings · EDID Minder
UL Safety Requirements
TheUnderwritersLaboratories(UL)requirementslistedbelowpertaintothesafeinstallation and operation of these devices.
Importantsafetyinstructions
1. Read these instructions.
2. Keep these instructions. 3. Heedallwarnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments or accessories specified by the manufacturer. 12. Useonlywiththestand,tripod,bracket,ortablespecifiedbythemanufacturer,orsold
with the apparatus. 13. Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatushasbeendamagedinanyway.Examplesofthiscouldbeifthepower-supply cord or plug is damaged, or if liquid has been spilled onto, or objects have fallen into the apparatus. Also if the apparatus has been exposed to rain or moisture, or does not operate normally, or has been dropped.

https://manual-hub.com/

PVTSeries·Installation 5

InstallingthePVTCVandPVTRGBDecoramodels
ThePVTCVandPVTRGBDecoramodelscanbeinstalledintoawallusingeitherthe suppliedmudringoraULapprovedone-gangelectricalwallbox,andfinishedwithaDecora wall plate cover (supplied). The installation must conform to national and local electrical codes and to the wall plate size requirements. ThefollowingUnderwritersLaboratories(UL)requirementspertaintotheinstallationofthe PVTinputwallplatesintoawallorfurniture. 1. These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range. 2. TheseunitsmustbeinstalledinULlistedjunctionboxes. 3. TheseunitsmustbeinstalledwithconduitinaccordancewithNationalElectricaland
BuildongCodes
ToInstallintoaMud-ring
1. Usingthemudringasaguide,marktheedgesandcutoutthematerialwithinthe marked area.
2. Insert the mud ring into the opening, rotate the arms, and secure with the supplied screws.
3. RuntheCAT5cablesfromthePoleVaultswitcherlocation,goingbehindthewallandto thePVTlocation,thenthreadthecablesthroughthemudring.
NOTE: Twocables(AandB)areneededforRGBsignals. OnecableisusedwithCVmodels.
Wall
Wall Mounting Bracket (mud ring)
AUDIOOUT IN COMPUTER IN MONITOR OUT
G S IR OUT
Extron PVT RGB D Plus
Figure 7. Installing the mud ring
4. ConnecttheswitchercablestotherearofthePVTwallplate.See"Rear Panel Features",page11,forconnectorwiringdetails.
5. Connect input devices (see "Front Panel Features",page9,forconnectordetails), restore the power supply, and test the wall plate. Make any cabling adjustments before final installation, as the cables will be inaccessible afterwards.

https://manual-hub.com/

PVTSeries·Installation 6

ToInstallintoaWallBox
Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables. The box should be at least 2.5 inches (6.4 cm) deep to accommodate the connectors and cables. Install the cables into the wall, furniture, or conduits before installing the wall plate.
Follow the steps below
1. Feed cables for the output devices through the opening and through the wall box punch-out holes, securing them with cable clamps to provide strain relief.
2. Trim back and/or insulate exposed cable shields with heat shrink to reduce the chance of short circuits.
To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp.
Bothbraidedandfoilshieldsshouldbeconnectedtoanequipmentgroundattheother end of the cable.
3. ConnectthePoleVaultswitchercablestotherearofthePVTwallplate.See"Rear Panel Features"onpage11forconnectorwiringdetails.
4. Connect input devices (see "Front Panel Features"onpage9forconnectordetails), restore the power supply, and test the wall plate. Make any cabling adjustments before final installation, as the cables are inaccessible afterwards.
InstallingthePVTCVandPVTRGBAAPmodels
ThePVTCVAAPandPVTRGBAAPmustbeattachedtoadevicefaceplateorAAPwallplate and cabled before the device or wall plate is tested and installed in a wall or furniture.
1. Beforeattachinganycables,inserttheAAPstandoffsthroughtheholesinthefaceplate or AAP wall plate.
2. Usingthesupplied#4-40nutsandcaptivewashers,securetheAAPtothefaceplateor wall plate.

AAP 102

S
G OIURT COMPINUTER

AUDIOPINVT RGB AAP

AAP 102

PVT RGB

Extron PVT RGB AAP
Figure 8. Mounting the PVT RGB AAP

3. Repeat steps 1 and 2 to mount any other AAPs. Cover any openings in the faceplate with blank plates (provided with the AAP faceplate).
4. BesuretoincludetheAAPconnectorsaspartoftheinstallationpretestbeforefinal installation of the faceplate.

PVTSeries·Installation 7

https://manual-hub.com/

5. For more detailed installation information, refer to the installation guide shipped with the device.
NOTE: ThePVTinputwallplateshouldbecabledandtestedbeforeitisfinally installed into the wall or device face plate. The rear panel connections will be inaccessible after installation. See Rear Panel - Features on page 11.
6. Aftertestingandmakinganyadjustments,turnoffthepowersupplytothePoleVault switcher, and carefully secure the faceplate on the wall box device.
7. Reconnect the cables and turn on the power supply to the switcher. This powers up the AAP plates.

https://manual-hub.com/

PVTSeries·Installation 8

Connections and Settings

ThesectiondiscussesthemethodofcablingandusingEDIDMinderforthePVTseries wallplates. This section covers the following: · Front Panel Features · Rear Panel (Cabling and Features) · EDID Minder · Final Installation
CAUTION: Do not connect these devices to a computer data or telecommunications network.

FrontPanelFeatures
The front panel features are the same within these groups: · PVTCVDandPVTCVAAP,and · PVTRGBD,PVTRGBDPlus,andPVTRGBAAP:

1 VIDEO IN

3

AUDIO IN

L

R

2

IR OUT

7
S G

PVT CV D

3

1

VIDEO IN
PVT CV AAP

L

R

AUDIO IN

PVT CV

2

1
AUDIO IN
4
COMPUTER IN
5
S G IR OUT

1 4 5
7

AUDIO IN OUT COMPUTER IN
MONITOR OUT
S G IR OUT

7

1

8

IR

S

6

OUT

G

AUDIO IN

COMPUTER

7

IN

PVT RGB AAP

PVT RGB AAP 54

PVT RGB D

PVT RGB D PLUS

Figure 9. PVT series front panel features

a Dual color power LED (all models)--ThisLEDlightsredwhenpoweronly
(nosignal)isappliedtothePVT,andgreenwhenpowerandsignalarebothpresent.

https://manual-hub.com/

PVTSeries·ConnectionsandSettings 9

b Audio (left and right) input (CV D and CV AAP models) -- For unbalanced
left and right audio input, plug male RCA audio plugs into these two female RCA jacks (white = left, red = right).
Tip (Signal)

Sleeve (Gnd )

Right Channel (Red Jacket)

Tip (+)

Left Channel (White Jacket)
Figure 10. RCA audio connectors

Sleeve ( )

c Composite video input (CV D and CV AAP models) -- To input a composite
video signal from a suitable source, insert a male RCA plug into this yellow female RCA jack.

d Audio input (RGB D and RGB AAP models) -- Plug a 3.5 mm stereo audio

IN

plugintothisjackforunbalancedaudioinput.Wiretheplugasshowninfigure13.

Tip (L) Ring (R)

Sleeve ( )
Figure 11. 3.5 mm stereo audio plug
e RGB video input (RGB D and RGB AAP models) -- Connect a computer
videosourcetothis15-pinHDconnectorforhighresolutionRGBvideo input.
f Local monitor output (RGB D Plus model) -- Connect a monitor to this
15-pinHDtoviewtheoutputlocally.

COMPUTER IN
MONITOR OUT
S G

g IR pass-through (All models except PVT CV AAP) -- Connect to this 2-pole
IR pass-through connector to provide control via IR devices

h Audio pass-through (RGB D Plus model) -- Plug a local audio device into this
3.5mmstereojackforaudiopass-through.Wiretheplugasshowninfigure13.

OUT

RearPanel

Outputcabling
ThePVTcableterminationmethodisspecificfor PVTinputwallplatesusedwiththePoleVault switcher. The supplied cables are terminated to TIA/EIAT568Astandard.
NOTE: WhenterminatingCAT5e,CAT6, andSkew-FreeA/VUTPcableswith RJ-45 connectors, it must comply withtheTIA/EIAT568AorT568B wiring standards, with the same standard used at both ends. DO NOT connect to an MTP system.

Pins: 1 2345 6 78
Side View Insert Twisted Pair Wires
RJ-45 Connector

568A Pin Wire Color

568B Wire Color

1 White-green White-orange

2 Green

Orange

3 White-orange White-green

4 Blue

Blue

5 White-blue White-blue

6 Orange

Green

7 White-brown White-brown

8 Brown

Brown

https://manual-hub.com/

PVTSeries·ConnectionsandSettings 10

RearPanel--Features
All models have the output connectors on the rear panel.

2

1

PVT CV AAP

1

PVT CV D
Figure 12. PVT CV models rear panel features
a Composite video output (PVT CV models) -- For composite video output, using
CAT5eor6UTPcable,connectthisRJ-45femalevideooutputporttooneofthetwo composite video RJ-45 input connectors (labelled 3 and 4 video), on the rear panel of the
PoleVaultswitcher.

3A RGB

4A RGB

3B RGB/ VIDEO

4B RGB/ VIDEO

PVT CV D Input #3 Rear Panel

Composite Video Input Connectors on the
Rear Panel of the PVS Switcher

PVT CV D Input #4 Rear Panel

Figure 13. Connecting the PVT CV D to the PoleVault switcher

b IR connector (2-pole) (PVT RGB D, PVT RGB AAP, PVT RGB D Plus
models) -- For IR pass-through control, wire this connector from the IR controller,withgroundto"G"andsignalto"S").

2

G S

ON

5

5

1234 5

ON

GS

3a

RGB A RGB B OUT OUT

3b

2

1234 5

PVT RGB AAP

RGB A RGB B OUT OUT

ON 1234 5

5 3a
4 3b

G R L

G S

RGB A RGB B

2

OUT OUT

PVT RGB D

3a

3b

PVT RGB D PLUS

Figure 14. PVT RGB models rear panel features

Ñ RGB A output (PVT RGB models)--UsingCAT5eor6UTPcable,connectthisRJ-45
femaleoutputportlabelled"RGBAout"tooneoftheinputportslabelledA(for
example,2A)onthePoleVaultswitcher.

PVTSeries·ConnectionsandSettings 11

https://manual-hub.com/

Ö RGB B output (PVT RGB models)--UsingCAT5eor6UTPcable,connectthisRJ-45
femaleoutputportlabelled"RGBAout"tooneoftheinputportslabelledB(for example,2B)onthePoleVaultswitcher.
NOTE: Cable A carries horizontal sync information and the red, green, and bluesignals.CableBprimarilycarriestheaudiosignal,theverticalsync information,and5VDCtopowerthePVTtransmitter.

G S
RGB A RGB B OUT OUT

N15779

Cable from

PVT Output A

I

POWER

N P

U

T

S

Cable from

PVT O1u2Vtput B 5A MAX

1A RGB 2A RGB 3A RGB 4A RGB 1B RGB 2B RGB 3B RGB 4B RGB
/VIDEO /VIDEO

PVT RGB D Input #1
Rear Panel

RGB Input Connectors on the Rear Panel of the PVS Switcher

Cable from PVT Output A
Cable from PVT Output B RGB A RGB B
OUT OUT
PVT RGB D PLUS Input #2
Rear Panel

G S G R L

Figure 15. Connecting the PVT RGB D or PVT RGB D Plus to the PoleVault switcher

d Audio pass-through connector (PVT RGB D Plus models) -- Connect an
audio source to this 3-pole connector for audo pass through output. Connect G R L thegroundto"G",rightspeakerto"R",andleftspeakerto"L".
e EDID Minder 5-pole DIP switch -- If the display refresh rate and resolution
isknown,settheEDIDMinder5-poleDIPswitchesaccordingtotheEDIDtable (see "EDID Minder"section,page13fordetails).
Alternatively,iftheEDIDMinderisusedinLearnmode,setalltheDIPswitchestooff.

https://manual-hub.com/

PVTSeries·ConnectionsandSettings 12

EDIDMinder

ThePVTRGBD(EDID),PVTRGBDPlus(EDID),andPVTRGBAAP(EDID) incorporatesEDIDMinder,whichallowsthetransmittertocommunicatethe appropriateEDIDinformationtothesource,ensuringcorrectvideooutput
resolution.

AUDIO IN OUT COMPUTER IN
MONITOR OUT

The5-poleEDIDMindersettingsDIPswitchislocatedontherearofthe wallplate. Once installed, these switch settings are only accessible by removing the device from its installed location.

S G IR OUT

ThefactoryEDIDsetting(default)is1024x768@60Hz(preset2).

TheEDIDMinderhastwomodes;aPreset(Emulation)modeandaLearn mode.

· Preset ModeisavailableonallPVTRGB(EDID)models,andallowsselectionof pre-programedEDIDrates,asshowninthetablebelow.

· Learn ModeisavailableonlyonthePVTRGBDPlusmodel,andenablesthedisplays specificEDIDinformationtoberecordedandemulatedbytheinputwallplate.

TousetheEDIDMindermodeinPresetorLearnMode,followtheinstructionsbelow

Using Preset mode

1. If already installed, disconnect any sources and displays from the front panel and remove the wallplate from the wall.
2. Ontherearpanel,setDIPswitch1to50or60kHzasdesired.
3. SetDIPswitches2-5accordinglytomatchthedesiredEDIDrate (see table below).
4. Connectthevideosourcetothe"ComputerIn"VGAconnector andalocaldisplaydevicetothe"MonitorOut"port.

ON

60 1 2 3 4 5

Hz

EDID

50

Selection

This setting is for 1024x768@60 Hz, preset 2 (factory default)

5. Restartthevideosourceanddisplaydevices.Verifytheimage,makinganychangesto theEDIDsettingsasneeded.

6. Whentheimageiscorrect,re-installthewallplate.Re-connectandrestartthesource and display devices.

Preset

Number

2

0

OFF

1

OFF

2

OFF

3

OFF

4

OFF

5

OFF

6

OFF

7

OFF

8

ON

9

ON

A

ON

B

ON

C

ON

D

ON

E

ON

F

ON

Switch setting

3

4

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

ON

ON

ON

Resolution 5

OFF LearnMode(PVTRGBDPlusonly)

ON

800x600

OFF

1024x768 (default)

ON

1280x720

OFF

1280x768

ON

1280x800

OFF

1280x1024

ON

1360x768

OFF

1366x768

ON

1400x1050

OFF

1440x900

ON

1600x1200

OFF

1680x1050

ON

1920x1080

OFF

1920x1200

ON

N/A

PVTSeries·ConnectionsandSettings 13

https://manual-hub.com/

UsingLearnmode(availableonPVTRGBDPlusonly)

1. Disconnect any sources from the front panel and remove the wallplate from the wall.
2. On the rear panel, set all the DIP switches to off (down).
3. Temporarily connect the main display device (the projector) to the"MonitorOut"port.
4. Onthefrontpanel,thelearnLEDislitsolidgreen.Pressand release the Learn button.

AUDIO IN OUT COMPUTER IN
MONITOR OUT
S G IR OUT

EDID Learn Button EDID Learn Status LED

5. TheLEDflashesredwhenin"learning"mode,thenreturnsto solid green when complete.

6. Re-install the wallplate and reconnect the source device. Connect a local display device tothe"MonitorOut"portasneeded.

7. ReconnecttheprojectortothePoleVaultswitcher.Restartthesourceanddisplaydevices

Finalinstallation
After testing and making any adjustments, do the following: 1. TurnoffthepowersupplytothePoleVaultswitcher.
NOTE: ThepowertothetransmitterissuppliedbythePoleVaultswitcher.

2. Mount the transmitter into the box or mud ring, and attach the supplied Decora faceplate to the transmitter, as shown below.
Wall

Wall Mounting Bracket (mud ring)
RGB output cables

AUDIOOUT IN COMPUTER IN MONITOR OUT
G S IR OUT
Extron PVT RGB D Plus (EDID)

Decora Faceplate

Figure 16. Mounting the PVT RGB D Plus (EDID)
3. Reconnect the cables and turn on the power supply to the switcher This powers up the wall plates.

https://manual-hub.com/

PVTSeries·ConnectionsandSettings 14

Reference Material

This section provides information about:
· Specifications
· Part Numbers and Accessories
Specifications
PVT Series
NOTE: ThesetransmittersarecompatibleonlywithanExtronPoleVault®Switcher(PVS).Theyarenotcompatible with other models of twisted pair receivers.
Video--RGB
Gain...............................................  Unity
Videoinputandloop-through--RGB
Number/signal type PVTRGBDPlusmodels............  1VGA-UXGARGBHV,RGBS 1bufferedRGBHV,RGBSlocalmonitorloop-through All other models ......................  1VGA-UXGARGBHV,RGBS
Connectors PVTRGBDPlus........................  2female15-pinHD(1forinput,1forloop-through) All other models ......................  1female15-pinHD
Nominal level .................................  0.7Vp-pforRGB Minimum/maximum levels..............  Analog:0.3Vto1.5Vp-pwithnooffset Impedance ..................................... 75 ohms Horizontalfrequency ......................  15kHzto130kHz Verticalfrequency...........................  30Hzto150Hz Return loss .....................................  <-30dB@5MHz DC offset (max. allowable) .............  250mV
Videooutput--RGB
Number/signal type ........................ 2 analog proprietary signals Connectors
All models ............................... 2 female RJ-45
Sync--RGB
Input type ......................................  RGBHV,RGBS Input level ......................................  3.5Vto5.5Vp-p,unterminated Input impedance ............................ 510 ohms Max. input voltage .........................  5.5Vp-p
Video--compositevideo
Gain...............................................  Unity Differential phase error...................  <1.0°at3.58MHzand4.43MHz Differential gain error .....................  <1.0%at3.58MHzand4.43MHz

https://manual-hub.com/

PVTSeries·ReferenceMaterial 15

Videoinput--compositevideo
Number/signal type ........................ 1 composite video Connectors .................................... 1 female RCA Nominal level .................................  1Vp-pforcompositevideo Minimum/maximum levels..............  Analog:0.3Vto1.5Vp-pwithnooffset Impedance ..................................... 75 ohms Return loss .....................................  <-30dB@10MHz DC offset (max. allowable) .............  100mV
Videooutput--compositevideo
Number/signal type ........................ 1 analog proprietary signal Connectors
All models ............................... 1 female RJ-45
Sync--compositevideo
Standards.......................................  NTSC3.58,NTSC4.43,PAL,SECAM
Audioinput
Number/signal type PVTRGBDPlus........................ 2 stereo, unbalanced: 1 input, 1 pass-through All other models ...................... 1 stereo, unbalanced
Connectors AllRGBmodels ........................ (1) 3.5 mm mini audio jack (tip, ring, sleeve) AllCVmodels .......................... 1 pair female RCA
Impedance ..................................... >10k ohms unbalanced, AC coupled Nominal level .................................  -10dBV(316mVrms) Maximum level...............................  +11dBu,(unbalanced)at1%THD+N
NOTE: 0dBu=0.775Vrms,0dBV=1Vrms,0dBV2dBu
AudiooutputtoaPoleVaultswitcher(allmodels)
Number/signal type ........................ 1 analog proprietary signal Connectors
All models ............................... 1 female RJ-45
Audiooutput--pass-through,PVTRGBDPlusonly
Number/signal type ........................ 1 stereo, unbalanced Connector...................................... (1) 3.5 mm mini audio jack (tip, ring, sleeve)
Control--IRport--PVTCVD,PVTRGBDPlus, PVTRGBD(EDID),PVTRGBAAP(EDID)
Number and connectors ................. 1 female 3.5 mm captive screw connector, 2 pole, for IR pass-through
General
Power ............................................  SuppliedbyaPoleVaulttwistedpairreceiver/switcher Power input requirements
PVTRGBD,PVTRGBAAP,PVTRGBDPlus 5.5VDC,0.15A
PVTCVAAP,PVTCVD ............  5.5VDC,0.11A Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Cooling .......................................... Convection, no vents Mounting
Rack mount PVTCVAAP,PVTRGBAAP  Yes,withoptionalfaceplate
Furniture or wall mount PVTCVD,PVTRGBD,PVTRGBDPlus Yes,withtheincludedDecora® wall plate PVTCVAAP,PVTRGBAAP  Yes,withoptionalfaceplatesorAAPwallplates

https://manual-hub.com/

PVTSeries·ReferenceMaterial

16

Enclosuretype

PVTCVD,PVTRGBD,PVTRGBDPlus

Plastic

All other models ...................... Metal Enclosuredimensions

)PVTCVD,PVTRGBDandPVTRGBDPlus(includingEDIDmodels)

Faceplate ...........................  2.6"Hx1.3"Wx0.2"D (6.6cmHx3.3cmWx0.6cmD)

(Fits the openings in a 1 gang Decora® plate.)

Device................................  2.7"Hx1.7"Wx1.6"D (6.9cmHx4.3cmWx4.1cmD)

PVTRGBAAP(EDID)

(Depth excludes connectors, height excludes mounting tabs.)

Faceplate ...........................  1.4"Hx3.5"Wx0.1"D (3.5cmHx8.9cmWx0.3cmD)

(double space AAP plate)

Device................................  1.4"Hx2.7"Wx1.6"D (3.6cmHx6.9cmWx4.1cmD)

(Depth excludes connectors, height excludes mounting tabs.)

Product weight

All models ............................... 0.2 lbs (0.1 kg)

Shipping weight ............................. 2 lbs (1 kg) Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance Safety ......................................  CE,c-UL,UL EMI/EMC .................................  CE,C-tick,FCCClassA,ICES,VCCI
MTBF ............................................. 30,000 hours Warranty ........................................ 3 years parts and labor

NOTES: All nominal levels are at ±10%. Specifications are subject to change without notice.

https://manual-hub.com/

PVTSeries·ReferenceMaterial

17

PartNumbersandAccessories
PoleVaultAVInputPlatePartNumbers
Description PVTCVD PVTRGBD PVTRGBDPLUS PVTCVAAP,black,white PVTRGBAAP,black,white

PartNumber 60-819-33 60-1066-03 60-1065-03 70-579-12,13 70-722-02,03

IncludedParts
Itemsmarked*areforPVTCVD,PVTRGBD,andPVTRGBDPlusmodelsonly.

Description Single gang Decora® wall plate* Single gang mudring* Captive screw connector, 2-pole 6-32, 7/8L, mounting screws* TieWrap Setup guide

Quantity 1 1 1 2 1 1

OptionalAccessories
Description CAT 5e cable, 35', plenum CAT 5e cable, 50', plenum CAT 5e cable, 75', plenum CAT 5e cable, 100', plenum

PartNumber 26-637-35 26-637-50 26-637-75 26-637-100

AAPOptionalParts
These items can be ordered separately and for AAP models only:

Description AAP 100 panel, black, white AAP 102 panel, black, white AAP 104 panel, black, white AAP201panel,½rackwidth,1U,black AAP301panel,1rackwidth,1U,black AAP302panel,1rackwidth,2U,black

PartNumber 60-593-02, 03 60-300-02, 03 60-301-02, 03 60-302-02 60-632-02 60-633-02

https://manual-hub.com/

PVTSeries·ReferenceMaterial

18

https://manual-hub.com/

PVTSeries·ReferenceMaterial

19

ExtronWarranty
ExtronElectronicswarrantsthisproductagainstdefectsinmaterialsandworkmanshipforaperiodofthreeyears from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanshipand/ormaterials,ExtronElectronicswill,atitsoption,repairorreplacesaidproductsorcomponents, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:

USA,Canada,SouthAmerica,
andCentralAmerica: Extron Electronics 1001EastBallRoad
Anaheim, CA 92805 U.S.A.

Japan: ExtronElectronics,Japan KyodoBuilding,16Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan

Europe and Africa: ExtronEurope Hanzeboulevard10 3825PHAmersfoort
The Netherlands

China: ExtronChina 686 Ronghua Road Songjiang District Shanghai 201611 China

Asia: ExtronAsia 135JooSengRoad,#04-01 PMIndustrialBldg.
Singapore 368363
Singapore

Middle East: ExtronMiddleEast DubaiAirportFreeZone F12,POBox293666 UnitedArabEmirates,Dubai

ThisLimitedWarrantydoesnotapplyifthefaulthasbeencausedbymisuse,improperhandlingcare,electricalor mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not authorizedbyExtron.

NOTE: Ifaproductisdefective,pleasecallExtronandaskforanApplicationEngineertoreceiveanRA(Return Authorization) number. This will begin the repair process.

USA: 714.491.1500 or 800.633.9876 Asia: 65.6383.4400

Europe: Japan:

31.33.453.4040 81.3.3511.7655

Unitsmustbereturnedinsured,withshippingchargesprepaid.Ifnotinsured,youassumetheriskoflossordamage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronicsmakesnofurtherwarrantieseitherexpressedorimpliedwithrespecttotheproductanditsquality, performance,merchantability,orfitnessforanyparticularuse.InnoeventwillExtronElectronicsbeliablefordirect, indirect,orconsequentialdamagesresultingfromanydefectinthisproductevenifExtronElectronicshasbeen advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.

Extron Headquarters

+1.800.633.9876 (Inside USA/Canada Only)

Extron USA - West +1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East +1.919.850.1000 +1.919.850.1001 FAX

Extron Europe
+800.3987.6673 (Inside Europe Only)
+31.33.453.4040 +31.33.453.4050 FAX

Extron Asia
+800.7339.8766 (Inside Asia Only)
+65.6383.4400 +65.6383.4664 FAX

Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX

Extron China
+4000.398766 Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX

Extron Middle East
+971.4.2991800 +971.4.2991880 FAX

© 2012 Extron Electronics All rights reserved. www.extron.com

Extron Korea
+82.2.3444.1571 +82.2.3444.1575 FAX

Extron India
1800.3070.3777 Inside India Only
+91.80.3055.3777 +91.80.3055.3737 FAX

https://manual-hub.com/



References