User Manual for SHOWVEN models including: V1.1 2024-06-26 Circle Flamer II, V1.1 2024-06-26, Circle Flamer II, Flamer II, II

asd

Circle Flamer II 20240608

Download List - SHOWVEN

USER MANUAL Circle Flamer II SHOWVEN ...

USER MANUAL Circle Flamer II - SHOWVEN

Δ Technical Specifications \ Model: Circle Flamer II \ Housing Material: Die-casting Aluminum \ Dimension: 610 330 330mm \ Weight: 35kg \ Input: AC100-240V, 50/60Hz \ Work Power: 550W \ Battery Powered: Yes, 16pcs 18650 cells, 24h standby \ Ignition: Dual, high voltage electron ignition \ Flame Monitoring: Yes \ Dual Vlave: Yes \ Control: DMX , 9-60V pyro signal, Wireless with Wireless DMX ...


File Info : application/pdf, 24 Pages, 1.43MB

PDF preview unavailable. Download the PDF instead.

Circle-Flamer-II-20240608
USER MANUAL Circle Flamer II
V1.1 2024/06/26
SHOWVEN Technologies Co., Ltd

Thanks for choosing SHOWVEN Circle Flamer II, we wish it will bring you lots of exciting moments. Please read the following user's manual and related product installation guide carefully before
operating this device.

 Safety Instructions

1. Safety icons explanation

Safety instructions warn of hazards when handling equipment and provide information on how to avoid those hazards. They are classified according to the severity of the hazard and are divided into the following groups. Please do follow all safety instructions in this document!

DANGER:

Indicates a hazardous situation that, if not avoided, will result in death or serious injury. (This signal word is limited to the most extreme situations)

WARNING: Indicates a hazardous situation that, if not avoided, could result in serious injury

CAUTION:

Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.

NOTICE:

Provide additional or supplementary information.

2. General Safety Instructions
\ Unauthorized repair are prohibited, it may cause serious incident.
\ Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. Unplug and turn off the machine when not use.
\ Please connect DMX cable before power on Circle Flamer II, and ensure that the communication command is disarmed, and the safety switch of device is under test mode.
\ After turning on the device, no person allows to stay in the danger area. Ensure all persons that are part of the show be informed about the safety distance, risks and functions of the device.
\ Always have a CO2 fire extinguisher and an extinguishing blanket in case of needed.
\ If there be any doubt as to the safety operation of the device in any circumstances, the device should be taken out of service immediately. Be sure the device is in good operating condition before use. If fail to fire correctly, immediately shut down and check it accordingly. Any questions please always contact SHOWVEN (info@showven.cn) for help.
\ Be sure to use high quality fuels, otherwise, it is easily leads to failure or danger. Please keep fuels away from heat source, sparks, fire or other possibility of ignition. Do not smoke!
\ The operator responsible for the control of flame system must always have a clear view of the device, so that he/she can stop the show immediately when there is danger. The main AC power switch should near operator. So that operator can turn off the power of all devices in case of abnormal.
\ The device shall not be altered and applied to other use purpose.

3. Disclaimers:
SHOWVEN technologies Co., Ltd excludes liability for unsafe situations, accidents and damages resulting from:
1. Ignoring warnings or regulations as shown on product manual or this manual. 2. Use for other applications or circumstances other than those indicated herein. 3. Changes to the device, including use of non-original spare parts, lack of maintenance etc. 4. Dismantling device without authorization from SHOWVEN. 5. Use this machine by unqualified or untrained personnel. 6. Improper use of machine Warning
A dry powder fire extinguisher, a carbon dioxide fire extinguisher and a fire blanket must be equipped next to the equipment. Someone must be on duty during operation. In case of fire accident, dry powder fire extinguisher can be used when the fire is large, and a carbon dioxide fire extinguisher can be used when the fire is small.

 Technical Specifications
\ Model: Circle Flamer II \ Housing Material: Die-casting Aluminum \ Dimension: 610 330 330mm \ Weight: 35kg \ Input: AC100-240V, 50/60Hz \ Work Power: 550W \ Battery Powered: Yes, 16pcs 18650 cells, 24h standby \ Ignition: Dual, high voltage electron ignition \ Flame Monitoring: Yes \ Dual Vlave: Yes \ Control: DMX , 9-60V pyro signal, Wireless with Wireless DMX Receiver (5-PIN DMX IN with DC5V
power supply) \ DMX: 3-pin and 5-pin DMX IN / OUT \ E-Stop Interface: Yes, can be connected in series \ Effect Direction: 210 ( 105 ) \ Flame Height: up to 12m \ Nozzle Optional (Max. height): NOZZLE EL(6m), L (8m), PM (10m), H(12m) \ Tank Capacity: 9L \ Fuel: ISOPAR L, ISOPROPANOL \ Liquid Level Sensor: Yes \ Fuel Tube Filter: Yes \ Tip sensor: Yes \ Usage in Rain: Yes \ ARM light: Yes \ Stereo Stand Hole: Yes, ( 36mm depth 62mm)

 Structure
1. Rear panel 2. Top panel 3. Handle 4. Fire box 5. Igniter (Dual) 6. Nozzle 7. Flame monitor 8. Fuel tank lid Diagram of bottom panel

 Rear Panel

1. Touch button 2. Power Switch (with Power indicator light) 3. Power IN / OUT 4. Safety switch 5. DC12V external fuel pump power supply 6. 3-pin XLR IN/OUT 7. 5-pin XLR IN/OUT (5-PIN XLR IN can charge for wireless DMX pen through pin1 and 4, pin4 with
DC5V power supply) 8. 9-60V pyro signal port 9. E-stop interface 10. ARM indicator light

 Display and setting
1. Welcome interface
Software Version Serial Number Pump Run Time Ignition Times

Circle Flamer II-240520 *********** 00:00:00 xx

2. Main interface

1.) Status Bar : appears when "Flame Monitor" is "ON" : appears when "Flame Monitor" is "ON" and detected successful ignition : appears when "External Trigger" is "ON" : appears when "safety switch" stay at "USER MODE" : it appears when machine is charging
: battery volume
: No battery or battery box not connected 2.) Data Bar
DMX: DMX address, Background turns from BLACK to RED when DMX cable was connected. SAFE: Safety address, Background turns from BLACK to RED when DMX cable was connected and safety channel activated. PRES: Pressure value. Background turns from BLACK to RED when pressure reached / exceed 90% of "set pressure"value. FUEL: Fuel level indicate. Background turns from BLACK to RED when actual fuel level (display in MONI) "Fuel Level Alarm" setting in ADVANCED MENU.
3.) Message Bar USER MODE / error or alert information display, Background color turns to RED when under "USER MODE".
4.) Touch Button function display: First Button: MENU / BACK Second Button: UP / LEFT Third Button: DOWN / RIGHT Fourth Button: MONI / EDIT / SAVE
3. ARM indicator light

Operators can enable/disable the arm indicator light by set the "ARM STATE" in ADVANCED menu. If "ARM STATE" is ON, there will be three status: OFF: DMX signal input BLINK: DMX armed or Ext Ignite in advanced menu is ON ON: no DMX signal and Ext Ignite in advanced menu is OFF

4. Alert Message
Alert Message E0 Test Mode E0 Factory Mode
E0 ExtIgnite ON
E0 Ignition Disenable E0 Key Lock E0 Invert ON
E0 Motor Disable

Why it appears Safety Key Switch at TEST MODE
Factory mode
"External Trigger" is "ON"
"Ignition" is "Disenable"
Touch button no operation in 30s "Invert"is set to ON in advanced menu "Motor"is set to"Enable" in advanced
menu

How to remove Switch Key to USER MODE
Switch to Normal mode Set "External Trigger" to "OFF" in
Advanced menu Set "Ignition" to "Enable" in
Factory menu Restart machine
Set to OFF
Set to Disabled

5. Error Message Error Message
E1 Pressure Err
E2 P Relief Err E3 Press Sensor

Why it appears
Consecutive pressurize failure times exceed "Pressure Fail Cnt" setting value
in factory menu Pressure high after depressurize
Pressure sensor disconnect / damage

How to remove
Restart machine or reset safety channel
Restart machine please check pressure sensor.

E4 Motor Err E5 Bat Err E6 Tip Err E7 Fuel Low
E8 MissFire Exceed

Nozzle not arrived designed postion on time
Battery voltage abnormal
Machine slant over 45° , it stops running
Actual "Fuel Level" < set value of "Fuel Level Alarm" in ADVANCED MENU
Consecutive ignition failures exceed the set value of "Fl Moni Fail Num" in advanced interface

Check the nozzle and restart machine
Charge for the battery. if still appear E5, battery might be damage please
replace battery Tip setting set to OFF, or horizontal
install machine.
Fill the tank
Restart machine / reset safety channel / set "Flame Monitor" to OFF

6. Monitoring Interface Press "MONI" enter below interface
Menu Pressure Fuel Level Igniter Voltage DC voltage BAT voltage Pump A Pump B Motor Voltage
Range of angle limit
User Mode Motor offset Pump Run Time Ignition Times

Explanation Current pressure value
Current fuel level Flame monitoring value display
DC power supply voltage Battery voltage display Pump A current value Pump B current value
Motor voltage of power supply The range of current angle limit
(Mini. NO ~ Max. NO ) <15V is under test mode
Nozzle angle offset Accumulative pump working time
Accumulative ignition times

7. Menu Interface Press "MENU" enter below interface
Menu MAIN ADVANCED TEST FACTORY

Explanation Main menu Advanced menu Test menu Factory menu (factory use only)

8. Main menu
Select "MAIN" in menu interface, press "EDIT" enter main menu. Use UP / DOWN / SAVE to change the parameters.

Menu Set DMX Address Min Angle Limit
Max Angle Limit

Range 1~512

Default 1

Explanation
DMX address setup Restrict the minimum nozzle
output direction Restrict the maximum nozzle
output direction

9. Advanced menu
Select "ADVANCED" in menu interface, press "EDIT" enter advanced menu. Use UP / DOWN / SAVE to change the parameters.

Items External Trigger Set Ext Sequence
Head to middle
Invert Motor Disabled Automatic Limit Motor Err Switch
Tip Setting Fuel Level Alarm
Fuel Input PV ON FuelLevel PV OFF FuelLevel Flame Monitor Flame Moni Value
Fl Moni Fai Num Key Sound ARM State
LCD Backlight
Key Lock
Default Parameter

Contents OFF / ON
1-89
OFF / ON
OFF / ON ON/OFF ON/OFF ON/OFF OFF / ON 0-100 ON / OFF 0-100 0-100 ON/OFF 0.01V-3.30V
1-10 ON/OFF ON/OFF ON/OFF
ON/OFF ON/OFF

Default OFF 89
OFF
OFF OFF OFF OFF ON
5 OFF 20 50 OFF 0.4V
2 ON ON OFF
OFF OFF

Description
Trigger through 9-60V pyro ignition signal
Preset sequence triggered by pyro signal
ON: Channel 1=0, Firing head will back to middle position (NO.8) after running a preset sequence.
OFF Firing head position after firing will be
decided by CH1 DMX value. When turned on, all angles will be mirrored.
ON: output nozzle motor disabled ON: output nozzle will check the angle block limit automatically after power on machine ON: report error when nozzle not arrived designed postion on time Turn ON/OFF tip over function Machine will alarm and stop working when fuel level lower than setting value Automatic filling tank when fuel level low Automatic filling start when fuel level lower than this setting value. (Fuel Input ON status) Automatic filling stop when fuel level exceed this setting value. (Fuel Input ON status) Flame monitor function ON/OFF setting
Threshold value for a successful firing Consecutive ignition failures setting, if ignition fail times > setting value, machine will report error. Touch button sound ON / OFF
ARM indicator light ON/OFF setting LCD backlight ON/OFF. When ON, screen will flash when firing; OFF: LCD screen will turn off when no operation. ON: Touch button will disable if there is no operation in 30s. restart machine to active touch button. Reset default parameter settings

10. Test menu

Please disconnect DMX connection before enter test menu.
Select "TEST" in menu interface, press "EDIT" enter test menu. Use UP / DOWN / SAVE to change the parameters.
"External Trigger" will disable after enter TEST menu, Pressure relief valve will open, below related items will shows Running when testing, shows Finish after test finished.

Items ARM Test Jet Valve 1 Test Jet Valve 2 Test Relief Test Fuel Valve 1 Test Igniter 1 Test Igniter 2 Test Pump Test

Description Test ARM indicator light, blink once/s, blink 3 times Jet valve 1 ON/OFF 3 times, 1s per time Jet valve 2 ON/OFF 3 times, 1s per time Relief valve ON/OFF 3 times, 1s per time Fuel Valve 1 ON/OFF 3 times, 1s per time Igniter 1 ON/OFF 3 times, 1s per time Igniter 2 ON/OFF 3 times, 1s per time Pump will pressurize to "Set Pressure" value and keep 2s, and display "F".

Motor Test Motor Run Test 1 Motor Run Test 2 Motor Run Test 3 Motor Run Test 4

If pressurize time exceed setting value of "Max Pressure Limit", means pump test fail, it will display "E". Display "R" means machine is pressurizing. Output nozzle motor test: angle 1-15 wave sequence
Output nozzle motor test 1: angle 1, 8 step sequence
Output nozzle motor test 2: angle 8, 15 step sequence
Output nozzle motor test 3: angle 1, 8 wave sequence
Output nozzle motor test 4: angle 8, 15 wave sequence

 Firing Angles:
The firing angle for CIRCLE FLAMER II is ±105°, from the Audience Side view, there are altogether 15 firing angles as below.

Drive time for Effects:

Time needed for the motor drive from NO.8 to relevant angle.

No.

Angles

Drive time needed

NO.1

-105°

170ms

NO.2

-90°

150ms

NO.3

-75°

130ms

NO.4

-60°

110ms

NO.5

-45°

90ms

NO.6

-30°

70ms

NO.7

-15°

50ms

NO.8

0°

0ms

NO.9

15°

50ms

NO.10

30°

70ms

NO.11

45°

90ms

NO.12

60°

110ms

NO.13

75°

130ms

NO.14

90°

150ms

NO.15

105°

170ms

For example for the motor drive from 0°to 45°, it need 90ms, when operator design a show to synchronize to music, this drive time must be calculated.

 CIRCLE FLAMER II Firing Sequences

CIRCLE FLAMER II has 88 preset sequences, operator use related channel DMX value or sequence No. to access certain sequence. Below, you can find sequence list and single ignitions.

No.

Ignition angle

1

-105°

2

-90°

3

-75°

4

-60°

5

-45°

6

-30°

7

-15°

8

0°

9

15°

10

30°

11

45°

12

60°

13

75°

14

90°

15

105°

16

-105°

17

-90°

18

-75°

19

-60°

20

-45°

21

-30°

22

-15°

23

0°

24

15°

25

30°

26

45°

27

60°

28

75°

29

90°

30

105°

Single Ignition Sequence List

Description
Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame

Single shot duration
0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.04s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s 0.34s

Sequence Duration (For
reference) 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.19s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s 0.56s

CH5 DMX Value
3-5 6-7 8-10 11-12 13-15 16-17 18-20 21-22 23-25 26-28 29-30 31-33 34-35 36-38 39-40 41-43 44-45 46-48 49-50 51-53 54-56 57-58 59-61 62-63 64-66 67-68 69-71 72-73 74-76 77-79

No. Ignition angle NO.

31

Step from 1-15

32

Step from 15-1

33

Step 5>8>11

34

Step 11>8>5

35

Step 6>10

36

Step 10>6

37 Step 4>6>8>10>12

38 Step 12>10>8>6>4

39 Step 8>6>10>4>12

40 Step 8>10>6>12>4

Step Sequences List

Description
SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence

Nozzle movement
L -> R R -> L L -> R R -> L L -> R R -> L L -> R R -> L M>L>R>L>R M>R>L>R>L

Sequence Duration
2.66s 2.66s 0.92s 0.92s 0.75s 0.75s 1.27s 1.27s 1.60s 1.60s

CH5 DMX Value 80-81 82-84 85-86 87-89 90-91 92-94 95-96 97-99
100-101 102-104

41

Step from 1-15

42

Step from 15-1

43

Step 5>8>11

44

Step 11>8>5

45

Step 6>10

46

Step 10>6

47 Step 4>6>8>10>12

48 Step 12>10>8>6>4

49 Step 8>6>10>4>12

50 Step 8>10>6>12>4

No. Ignition angle NO.

51

Wave 5 -->11

52

Wave 11-->5

53

Big wave 1--15

54

Big wave 15--1

55

Wave 8-->1

56

Wave 8-->15

57

Wave 1-->8

58

Wave 15-->8

59

Wave 8-->11

60

Wave 8-->5

61

Wave 5-->8

62

Wave 11-->8

No. Ignition angle NO.

63

Step 3>13

64

Step 13>3

65

Step 3>13

66

Step 13>3

67

Step 8-13

68

Step 13-8

69

Step 8-13

70

Step 13-8

71

Step 8-3

72

Step 3-8

73

Step 8-3

74

Step 3-8

75

Step 3-13

76

Step 13-3

77

Step 2-14

78

Step 14-2

79

Step 8>5>11

80

Step 8>11>5

81

Step 5-11

82

Step 11-5

83

Wave 8-->13

84

Wave 13-->8

LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence

L -> R R -> L L -> R R -> L L -> R R -> L L -> R R -> L M>L>R>L>R M>R>L>R>L

7.78s 7.78s 1.82s 1.82s 1.25s 1.25s 2.68s 2.68s 2.88s 2.88s

105-107 108-109 110-112 113-114 115-117 118-119 120-122 123-124 125-127 128-130

Wave Sequence List

Description
Middle wave sequence Middle wave sequence LONG wave sequence LONG wave sequence Middle wave sequence Middle wave sequence Middle wave sequence Middle wave sequence SHORT wave sequence SHORT wave sequence SHORT wave sequence SHORT wave sequence

Nozzle movement
L -> R R -> L L -> R R -> L M -> L M -> R L -> M R -> M M -> R M -> L L -> M R -> M

Sequence Duration
1.87s 1.87s 4.08s 4.08s 2.09s 2.09s 2.31s 2.31s 0.99s 0.99s 1.08s 1.08s

CH5 DMX Value
131-132 133-135 136-137 138-140 141-142 143-145 146-147 148-150 151-152 153-155 156-158 159-160

Additional Sequences List

Description
SHORT flame Step sequence SHORT flame Step sequence LONG flame Step sequence LONG flame Step sequence SHORT flame Step sequence SHORT flame Step sequence LONG flame Step sequence LONG flame Step sequence SHORT flame Step sequence SHORT flame Step sequence LONG flame Step sequence LONG flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence SHORT flame Step sequence
Middle wave sequence Middle wave sequence

Nozzle movement
L -> R R -> L L -> R R -> L M -> R R -> M M -> R R -> M M -> L L -> M M -> L L -> M L -> R R -> L L -> R R -> L M>L>R M>R>L L -> R R -> L M -> R R -> M

Sequence Duration
0.93s 0.93s 1.63s 1.63s 1.55s 1.55s 3.24s 3.24s 1.54s 1.54s 3.24s 3.24s 1.98s 1.98s 2.32s 2.32s 0.93s 0.93s 1.28s 1.28s 1.70s 1.70s

CH5 DMX Value
161-163 164-165 166-168 169-170 171-173 174-175 176-178 179-181 182-183 184-186 187-188 189-191 192-193 194-196 197-198 199-201 202-203 204-206 207-209 210-211 212-214 215-216

85

Wave 8-->3

86

Wave 3-->8

87

Wave 3-->13

88

Wave 13-->3

>89

8(0°)

Middle wave sequence Middle wave sequence LONG wave sequence LONG wave sequence Single Ignition LONG flame

M -> L L -> M L -> R R -> L Static

1.60s 1.60s 3.06s 3.06s max. 8s

217-219 220-221 222-224 225-226 227-255

 DMX CONTROL

Circle Flamer II occupies 6 functional channel.

Channel CH1 CH2 CH3 CH4
CH5 CH6

Function Manual Angle setup Manual Nozzle Waving
Speed setup Firing ON/OFF
Firing Duration setup
Preset sequence setup
Firing Enable / Disable

Value
0~255: angle change from -105° to 105° 128: straight upward (0°)
0 and 255: Max Speed 1~254: Speed increase
0~253: Firing OFF 254~255: Firing ON 0 and 255: permanent fire (10s is limit duration time) 1~254: 10~2540ms duration time (Manual firing duration = DMX Value * 10ms) 0-2: no preset sequence 3-255: preset sequence DMX value = 2 + Sequence No.*2.55 (ROUND OFF)
0~49 and 201~255: Firing Disable (Emergency STOP) 50~200: Firing Enable

Channel 1 (CH1): Manual Angle Setup

Angle No.

Angle

DMX Value

1

-105°

0

2

-90°

18

3

-75°

36

4

-60°

54

5

-45°

73

6

-30°

91

7

-15°

109

8

0°

128

9

15°

146

10

30°

165

11

45°

183

12

60°

201

13

75°

219

14

90°

237

15

105°

255

1. The first channel controls the firing angle. It defines to which angle the nozzle of CIRCLE FLAMER move

to. The angle can be chosen anywhere between -105° to +105° (DMX value 0 to 255)

2. The DMX value for angle of 0° is 127.5 (round up 128). Use this value, following formula can be used
to calculate all other angles  in degree. Please always note the prefix of the angle DMX Value = 127.5 + (*1.2145)

Channel 2 (CH2): Manual Nozzle Waving Speed Setup

CH2: Nozzle Waving Speed Setup

DMX Value

0

1-254

255

Speed

Max Speed

Incremental of Speed

Max Speed

The second channel defines the nozzle waving speed. It work together with Channel 1 for manual firing

Channel 3 (CH3): Firing ON/OFF

CH3: Ignition

DMX Value

0-253

254-255

Firing

Firing OFF (igniter diable)

Firing ON (igniter enable)

The third channel activates the actual firing. If the DMX value of this channel higher than 253, the CIRCLE

FLAMER will firing.

Channel 4 (CH4): Firing Duration setup

CH4: Manual Firing Duration setup

DMX Value

0

1

2

3

4

Firing Duration Permanent 10ms 20ms 30ms 40ms

The fourth channel is the firing duration setup

Below formula can be used to calculate the firing duration (ms): DMX Value = t/10

......

254 2540ms

255 Permanent

Channel 5 (CH5): Program Sequence setup

The fifth Channel allows to firing a preset sequence. Three DMX values can be used for one of the

programmed firing sequence from above sequence list (refer to above sequence list table).

Below formula can be used to calculate firing sequence: DMX Value = 2 + Sequence No.*2.55

CH5: Sequence List

DMX Value

0~2

3~5

6~7

8~10 11~12 .......... 225-226

Sequence No.

N/A

1

2

3

4

88

Channel 6 (CH6): Firing Enable / Disable The sixth channel is the working mode of pump. When the safety lock located at TEST MODE, set DMX value between 50-200 to test the system. For safety, the device will not pressurize. When the safety lock located at USER MODE, the device pressurize activated by set DMX value between 50-200.

DMX Value Mode

0-49 Firing disable

CH6: Mode setup 50-200
Firing enable

201-255 Firing disable

 Operation

1. Safety distance explanation

Safety distance for CIRCLE FLAMER II divided into two parts safety radius around machine (a) and safety distance at firing direction (b). No person and flammable materials are allowed to stay inside the safety isolation zone when flamer was armed. The safety radius around machine depends on the firing height (nozzle size). For safety distance at firing direction equals to maximum firing height * 1.5. CIRCLE FLAMER II with maximum 105 waving firing angles, when firing step sequence, wave sequence or additional sequences the safety isolation zone is a three-dimensional sector area.

Nozzle Type
SFSMA027 Nozzle EL SFSMA024 Nozzle L SFSMA028 Nozzle PM SFSMA026 Nozzle H

Max. Flame Height
6m 8m 10m 12m

Safety Radius (a)
2m 2.5m 3m 3.5m

Safety Distance at Firing Direction (b) 9m
12m
15m
18m

The CIRCLE FLAMER II safety isolation zone is a three-dimensional space with a cross-section of 210° sector enclosed by a and b (check below diagram). We can understand it as a safety area formed by a safety column with diameter of a, height of b rotate of ±105 degrees. Unauthorized persons and objects are strictly prohibited from entering. Depending on the firing sequence / angles the sector area changes accordingly. For angled installation, the safety distance both around machine and firing direction should shift accordingly.
Safety distance in windy environment The safety isolation zone radius (a) increase with wind direction and wind speed (v, m/s). The safety distance in windy conditions can be calculated as below: For Nozzle L: a = 2.5 + v; For example when the wind speed is 3m/s, we use the Nozzle L, then the safety isolation zone radius should be 5.5m. CAUTION: When the wind speed  8m/s (wind force  5), please use it with caution. When wind speed  17m/s
wind force  8 , please stop use flamer. 2. Battery for Circle Flamer II
Circle Flamer II can be powered through 16 pcs of 18650 cells. New Circle Flamer II come only with battery compartment, customer need to get 18650 cells locally. The battery we suggest to use is with flat head as below:
The battery installation steps: a) Unscrew the screws of the battery box at the bottom panel as below.

b) Install the battery in correct direction, pay attention to the positive and negative pole. Wrong installation will damage the battery box or even machine.
c) Press and hold the reset button (as show in the red circle below) for 1s to activate battery.
d) Install back the battery box plate. e) Charging: charging automatically when machine connected with AC power supply (no matter
machine was powered on or not) NOTICE: To avoid the damage of battery, charge the battery at least once per month. NOTICE: 18650 battery activation is necessary whenever install the battery
3. Install Circle Flamer II a) Choose the correct nozzle, ensure the installation position of Circle Flamer II meet above safe distance requirements. New Circle Flamer II supplied with a nozzle PM which generate up to 10m flame. b) Horizontal installation is preferred for Circle Flamer II. If need to install Circle Flamer in angles, to avoid fake error message please turn the TIP Setting and Low fuel switch to OFF status first. Circle Flamer with maximum tilt angle of 45° or -45°, and it can be angled to two directions as show in below picture. Besides please be aware the fuel level in fuel tank to avoid fuel leakage when tilt installation.
c) For truss installations always connect with safety rope to ensure extra safety. If there is any other national or regional guidelines please follow it accordingly.
d) Double confirm the machine was firmly installed. 4. Fuel the Circle Flamer II
a) Switch safety lock to TEST MODE. b) Fill the fuel tank with qualified fuel.
WARNING: Fuel requirements for Circle Flamer II 1. Water content in fuel should less than 0.5% 2. For maximum safety, please use fuel with flash point between 60-80, ISOPAR L or M is highly
recommended. 3. Colored fuels are forbidden to use on Circle Flamer II it may damage the machine. SHOWVEN excludes liability for the losses, damages and accidents caused by not using qualified fuels in accordance with this requirement.

5. E-Stopper / E-stop terminator Connection E-stop interface is a power cut-off interface, the machine can be powered on normally only when ESTOP in is connected. For safer use of Circle Flamer II we suggest to connect it with E-stopper. For operators who don't want to use E-stopper can plug a E-stop terminator in E-STOP IN to enable the device. E-Stopper (optional) connect with single unit of Circle Flamer II.
E-Stopper (optional) connect with multi units of Circle Flamer II in daisy chain.
NOTICE: A unit of E-Stopper can control maximum 24 units of device. Use E-stop terminator (standard configuration): if without E-Stopper. Plug the E-stop terminator to the E-STOP IN port to enable the Circle Flamer II.
6. Connecting Circle Flamer II Make sure the DMX or pyro controller is disarmed or powered off during cable connection.
If control by DMX controller, follow below steps: a) Connect a DMX cable to the DMX IN socket of first unit of Circle Flamer II, another head of this DMX cable connect to DMX console (such as FXcommander). Make sure the DMX console is powered off. b) Connect a DMX cable to the DMX OUT socket of previous Circle Flamer II, and the other end to the DMX IN of next machine. Connect all devices in series in this way. c) Suggest to plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. For distance >200m please use SHOWVEN DMX splitter 8 to amplify the signal. d) Connect a power cable to the POWER IN socket of Circle Flamer II. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. e) Power on all Circle Flamer II. Check the safety lock, double confirm it stays at "TEST MODE".

f) Set the angle limit if needed g) Assign DMX address for each unit of Circle Flamer II. If use SHOWVEN host controller or
FXcommander to control the machine please allocate a unique DMX address for each unit of machine. If control by 9-60V pyro signal, follow below steps: a) Connect a power cable to the POWER IN socket of Circle Flamer II. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. b) Connect the power control cables to the 9-60V pyro signal connector on Circle Flamer II. c) Connect the other end of power control cables to the pyro controller (9-60V external trigger source), such as SHOWVEN PyroSlave series module. Before connect please make sure there is no pyro signal input. d) Power on all Circle Flamer II e) Set the angle limit if needed f) Set the Ext Ignite to ON status in advanced interface, set the firing sequences at "Set Ext Sequence".
7. Power ON the DMX console / Pyro controller and programming Power on DMX console and program the Circle Flamer II effect on DMX console or Pyro controller.
8. Test the ignition function of Circle Flamer II Test the ignition function of Circle Flamer II, we can check whether the igniters of each unit of Circle Flamer II is working fine. Due to the safety switch is stay at TEST MODE there will be only ignition while jet solenoid valve is not open, so no flames generated.
9. Firing a) Double confirm the prescribed safety isolation zone is clear, no person, animal or other property within this region. b) Switch the safety lock of Circle Flamer II to USER MODE.
c) Firing, the operator should always have a clear view of the device, so that he/she can stop the show immediately when there is danger.
10. Depressurize and Power OFF a) Depressurize the flame unit after show or not use flamer for a period of time b) Power OFF DMX console c) Press E-Stopper to power OFF all machine (if connect with E-stopper) d) Switch safety lock of Circle Flamer II to TEST MODE e) Power OFF each unit of machine
11. Empty the remaining fuels and package machine a) Unplug power cable, DMX cable, E-Stopper connection cable etc. b) Suggest to empty the remaining fuels inside fuel tank before shipment and storage c) Package the machine after it is cool down

 Nozzle Replacement and Igniter Position Adjustment

1. Nozzle Types and Flame Height

Nozzle Type

Picture

Short Flamer Height (m) Long Flame Height (m)

Nozzle H SFSMA026

7-9m

10-12m

Nozzle PM SFSMA028

5-7m

8-10m

Nozzle L SFSMA024

3-5m

6-8m

Nozzle EL SFSMA027

3-4m

4-6m

2. Nozzle Replacement Use 14mm outer hexagon socket wrench (SFMET944) to disassemble the nozzle, clean the nozzle and nozzle socket with air gun (air compressor), change a new nozzle and install it.

3. Igniter Position Adjustment Whenever changed the nozzle or ignition is not good, please check igniter pole position according to below parameters. The right position for each pair of pole should have a gap from tip to tip of 2.5-3mm (b) and a gap between two igniter of 18mm (a). Check the ignition success rate after adjustment by firing

WARNING: Do unplug the power cable and power off the machine when service flamer.
4. Nozzle Installation Please assemble the stailess steel gasket, O ring and nozzle main part according to below picture. The O ring should be inside the stailess steel gasket, otherwise it may leads to fuel leakage. Use nozzle replacement tool outer hexagon socket wrench to tighten the nozzle.
 Maintenance
1. To maintain the machine in good performance and running status, it is recommended to running the device at least once per month.
2. Check the ignition probes both before and after each show, if there is any foreign objects on it please clean it up.
3. Maintenance of the nozzle: Nozzle needs to be cleaned from time to time, and it is recommended that once every six months (depending on the environment and frequency of use). In the process of using the equipment, if the flame shape is seriously deformed or the fuel injection line is significantly deformed or coarsened, the nozzle should be removed immediately for cleaning. If after clean, there are still problems please replace new nozzle.
4. Maintenance of the O-ring: If it is found that the O-ring of the nozzle is damaged or ageing when cleaning the nozzle, the Fluorine rubber O-ring should be replaced in time. O ring outter diameter is 14mm, wire diameter is 2mm.
5. Flame detector maintenance: Recommended to clean the carbon buildup on flame detector at least once per month (depending on the use environment and frequency), if the detector is found to be insensitive, clean it immediately.

6. Emptying operation of the fuel tank

fuel drain screw (G1/4)

WARNING:
Please pay attention to the tightening torque of the fuel drain screw. It should not exceed 10N*m, otherwise, the fuel tank will be damaged. This operation is prohibited for non-professionals.

 Optional Parts for Circle Flamer II

Part. No. SFSMA026 SFSMA028 SFSMA024 SFSMA027 RMSMA530

Description NOZZLE H NOZZLE PM NOZZLE L NOZZLE EL SS304 gasket, outer 18, inner 14, thickness 1.5mm

RMWAS025
SFMET1107 FPEST001 RMMET516 RMPCK293 FPFLI057 SFMET944 RMBOT036 SFMET944 RMEMD062

Fluorine O ring, outer 14, wire diameter is 2 mm
G1-E-Stop connector E-STOPPER
G1-Anti-static battery disassembly spudger Paper carton
Flightcase for single unit Tool for exchage nozzle
Safety loop Nozzle disassemble tool 5-pin wireless DMX receiver (compatible with FXcommander 2.4GHz wireless DMX)

 Warranty Instructions
\ Sincere thanks for your choosing our products, you will receive quality service from us \ The product warranty period is one year. If there are any quality problems within 7 days after shipping
out from our factory, we can exchange a brand new same model machine for you \ We will offer free of charge maintenance service for machines which with hardware malfunction
(except for the instrument damage caused by human factors) in warranty period. Please don't repair machine without factory permission Below situations NOT included in warranty service: \ Damage caused by use unqualified fuels; \ Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors; \ Disassemble, modify or repair products without permission; \ Damage caused by external reasons (lightning strike, power supply etc.) \ Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service. Invoice is necessary when applying for maintenance service from SHOWVEN

Showven Technologies Co., Ltd.
Tel: +86-731-83833068 Web: www.showven.cn E-mail: info@showven.cn Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, Changsha, Hunan, 410300,
P.R.China



References

Microsoft Word 2016 Microsoft Word 2016