Daikin Wired Remote Controller Operation Handbook
Button Locations and Descriptions
Model: BRC1H63W/BRC1H63K
The wired remote controller features an LCD display and several control buttons.
LCD Display: Shows current status, settings, and icons.
Status Indicator (LED): A light ring around the display indicates operation status:
- Blue: Operating
- Blinking Red: Error is occurring
- Blinking Green: Bluetooth connecting
Button Functions:
- ON/OFF Button: Press to turn the system on or off.
- NAVIGATE/ADJUST Button (Left): Navigate left or adjust a setting.
- NAVIGATE/ADJUST Button (Right): Navigate right or adjust a setting.
- SELECT/ACTIVATE/SET Button: From the home screen, enter the main menu. From the main menu, enter submenus. From submenus, activate an operation or ventilation mode.
Before Using the Product
This manual describes the basic operation of the indoor unit using the BRC1H63W/BRC1H63K remote controller. Keep this manual accessible for future reference.
For detailed contents, refer to the BRC1H63W/BRC1H63K operation manual on the Daikin website. For information beyond remote controller operation, consult the operation manual attached to the indoor unit.
For manuals in other languages, a web manual is available via a QR code (not included in this text-based output).
Information Screen Icons
About Icons on the Information Screen
The items displayed vary depending on the indoor unit. The following table describes common icons:
Icon Representation | Name | Description |
---|---|---|
[Info Screen] | Information Screen | Indicates an information screen. |
[Main/Sub] | MAIN/SUB remote controller | Displayed when used as the MAIN/SUB remote controller (1=main, 2=sub). |
? | Bluetooth* | Indicates the controller is communicating with a mobile device via the app. |
[Setback] | Setback | Indicates the indoor unit is operating under setback conditions, maintaining comfort by turning on when temperature exceeds a setpoint. |
[Centralized Control] | Centralized Control | Indicates the system is controlled by central control equipment, limiting controller functions. |
[Changeover] | Changeover Under Control (VRV only) | Displays master control status. Unable to select heating/cooling: displayed. Can be set as master: blinking. Able to select heating/cooling: not displayed. Check home screen for master controller. |
[Backup] | Backup | Indicates that backup operation is being carried out. |
[Energy Savings] | Energy savings | Indicates energy consumption is limited, running with restricted capacity. |
[Test Operation] | Test operation | Indicates that Test Operation mode is active. |
[Defrost/Hot Start] | Defrost/Hot start | Indicates that the defrost/hot start mode is active. |
[Self-cleaning] | Self-cleaning filter operation | Indicates that self-cleaning filter operation is active. |
[24h Ventilation] | 24-hour ventilation | Indicates that 24-hour ventilation is set. May not display even if connected to a unit with this function. |
[Night Purge] | Night purge | Indicates that night purge is set. |
[Ventilating Standby] | Ventilating standby | Indicates ventilating operation has stopped temporarily to reduce energy loss after cooling/heating starts. |
[Ventilating Operation] | Ventilating operation | Indicates ventilating operation is active even when the system is stopped, if 24-hour ventilation and night purge are set. |
[Pre Vent] | Pre Vent (Fresh-up) | Indicates powerful ventilating due to a large difference in incoming/exhaust airflow rates. |
⚠️ | Warning | Indicates an error occurred or a component needs maintenance. |
[Zigbee] | Zigbee* | Displayed: Zigbee sensor linked control available. Blinking: Error with Zigbee sensor connection. |
[Timer A] [Timer B] | Timer setting | (A): Off timer or Schedule available. (B): Clock setting is unset. |
* Bluetooth® and Zigbee™ are registered trademarks of their respective owners. Use by Daikin Industries LTD. is under license.
Safety Precautions
Please read these "Safety Precautions" carefully before installing or operating the remote controller. This manual classifies precautions into WARNINGS and CAUTIONS.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
- Installation: Installation work must be carried out by your dealer or qualified personnel. Do not attempt self-installation, as improper installation may cause electric shocks or fire.
- Relocation/Reinstallation: Consult your local dealer for relocation and reinstallation. Improper procedures may lead to electric shocks or fire.
- Installation Compliance: Install the remote controller according to this manual and applicable legislation. Improper installation may cause electric shocks or fire.
- Accessories: Use only specified accessories and parts. Failure to do so may result in the controller falling, electric shocks, or fire.
- Mounting: Install on a foundation that can withstand its mass to prevent falling and injury.
- Electrical Work: Ensure all electrical work is performed by qualified personnel according to applicable legislation and this manual, using a separate circuit. Use wiring with sufficient length; do not connect additional wiring. Insufficient capacity or improper construction may lead to electric shocks or fire. (Note 1 defines applicable legislation).
- Power: Turn off the power before installation. Touching live parts can cause electric shocks.
- Repair: Do not disassemble, reconstruct, or repair. Doing so may cause electric shock or fire.
- Wiring Security: Ensure all wiring is secured, using specified wirings, and that external forces do not act on terminals. Improper connections may cause overheating or fire.
- Standards: Material choice and installation must comply with applicable national and international standards.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
- Water/Insects: To prevent electric shocks from water or insects, fill wiring through holes with putty.
- Wet Hands: Do not operate with wet hands to avoid electric shocks.
- Washing: Do not wash the remote controller with water. This may cause electric shock or fire.
- Interference: Install the air conditioner, power supply wiring, remote controller wiring, and transmission wiring at least 1 meter away from televisions or radios to prevent image interference or noise. (1 meter may not be sufficient depending on radio waves).
- Unsuitable Locations: Do not install in:
- Areas with oil mist, oil spray, or vapor (e.g., kitchens), as resin parts may deteriorate.
- Areas where corrosive gas (e.g., sulphurous acid gas) is produced.
- Areas with machinery emitting electromagnetic waves, which may disturb the control system and cause malfunctions.
- Areas where flammable gas may leak, or where flammable dust or volatile flammables (thinner, gasoline) are handled, as this may result in fire.
- High temperature areas or near heat sources, which may cause overheating or fire.
- Moist areas or places exposed to water, as water ingress can cause component failure, electric shocks, or fire.
- Thermostat Sensor Location: When using the thermostat sensor, select a location that:
- Detects the average room temperature.
- Is not exposed to direct sunlight.
- Is far from heat sources.
- Is not affected by outdoor air (e.g., door opening/closing).
Maintenance
Maintaining the Unit and LCD Display
- Wipe the LCD and surface of the remote controller with a dry cloth when dirty.
- If dirt is stubborn, dampen a cloth with neutral detergent diluted in water, squeeze it tightly, clean the surface, and then wipe with a dry cloth.
- Do not use non-neutral detergents or organic solvents (alcohol disinfectant, benzene, paint thinner, etc.), as they may cause cracking, electric shocks, or fire.
NOTICE
Do not use any paint thinner, organic solvent, or strong acid.
Overview of Screens
The following describes screen transitions and basic operations. Available settings may vary by indoor unit. The screen returns to the home screen after approximately 10 seconds of no button operation.
Home Screen
Displays current temperature and operation status. Press the ON/OFF button to turn the system on/off.
To access the User Menu, press and hold the SELECT/ACTIVATE/SET button for 5 seconds.
Information Screen
Displays indoor unit functions, time, and error codes as icons. Refer to the "Information Screen Icons" section for details.
Use the NAVIGATE/ADJUST buttons to select an icon and press the SELECT/ACTIVATE/SET button to change it.
User Menu
Allows changing fundamental functions such as operation mode, fan speed, airflow direction, LED brightness, and Fahrenheit/Celsius display.
Use the NAVIGATE/ADJUST buttons to select an item and press the SELECT/ACTIVATE/SET button.
Changing the Operation Mode
Use NAVIGATE/ADJUST buttons to select the desired mode (Auto, Heat, Cool, Dry) and press SELECT/ACTIVATE/SET.
Changing the Fan Speed
Use NAVIGATE/ADJUST buttons to select the fan level (Lv1 to Lv5, Auto) and press SELECT/ACTIVATE/SET.
Changing the Airflow Direction
Use NAVIGATE/ADJUST buttons to select the airflow direction (Auto, Positions 0-4, Swing) and press SELECT/ACTIVATE/SET.
Names and Functions
Screen Display Explanation
This section details the various elements displayed on the screens:
- a OFF
- Displayed when operation is stopped.
- b Error/Filter/Test/Streamer/Zigbee icon
- Indicates Error (⚠️), Filter (⚙️), Test (?), Streamer ([Streamer]), and Zigbee ([Zigbee]) status.
- c Centralized Control
- Displayed when under centralized management.
- d Operation mode
- Displays the current operation mode (e.g., Cool, Heat).
- e Ventilation mode
- Displays the ventilation mode status.
- f Room temperature
- Displays the current room temperature.
- g Setback
- Blinks during setback operation; displayed during setback setting.
- h Bluetooth
- Indicates communication with a mobile device via the app (?).
- i Changeover Under Control
- Displayed when the controller is unauthorized to select heating/cooling operation.
- j Fahrenheit/Celsius
- Indicates the selected temperature unit (Fahrenheit or Celsius).
- k Air Purifying
- Indicates air purifying function status.
- l Set temperature
- Displays the target setpoint temperature.
- m Clock (24 hours time display)
- Displays the current time in 24-hour format (⏰).
- n MAIN/SUB remote controller sign
- Indicates if the controller is the main or sub unit.
- o Status
- Notifies the general status of the system.
- p Error display
- If an error occurs, displays an icon, error code, and unit number.
- q Information icon
- Indicates an information screen is active.
- r Bluetooth/Zigbee icon
- Displays Bluetooth (?) or Zigbee ([Zigbee]) connection status.
- s Sensor values
- Displays Zigbee sensor values if configured and received. Displays a horizontal bar ("-") if no sensors or values are unavailable.
- t Settings menu icon
- Indicates access to the settings menu.