User Manual for robustel models including: R3000 Lite IoT VPN 4G Cellular Gateway Router, R3000 Lite, R3000 Lite Gateway Router, IoT VPN 4G Cellular Gateway Router, 4G Cellular Gateway Router, Gateway Router, Gateway, Router
ation, User Guides, Product | Robustel
Router gateway cellulare R3000 OpenVPN IoT VPN 4G | Robustel
Robustel produktblade, brugervejl. og kvikguide - M2M Nordic ApS
File Info : application/pdf, 10 Pages, 631.00KB
DocumentDocumentRobustel R3000 Lite Hardware Manual R3000 Lite Hardware Manual Version: 1.0.0 Date: July 28, 2022 RT025_HM_R3000_Lite 1/10 Robustel R3000 Lite Hardware Manual Regulatory and Type Approval Information Table 1: Directives 2011/65/EC The European RoHS 2011/65/EU Directive was issued by the European parliament and the European Council on 1 July 2011 on the restriction of the use of certain Hazardous substances in electrical and electronic equipment. On June 4, 2015, the Official Journal of the European Union published the RoHS2.0 Amendment Directive (EU) In 2015/863, four phthalates (DEHP, BBP, DBP, DIBP) were officially included in the list of restricted substances in Appendix II of RoHS 2.0 (2011/65/EU). From July 22, 2019, all electronic and electrical products exported to Europe (except medical and monitoring equipment) must meet this restriction; from July 22, 2021, medical equipment and monitoring equipment will also be included in the scope of control. 2012/19/EU The European WEEE 2012/19/EU Directive was issued by the European parliament and the European Council on 24 July 2012 on waste electrical and electronic equipm Table 2: Toxic or Hazardous Substances or Elements with Defined Concentration Limits Name of the Part Hazardous Substances (Pb) (Hg) (Cd) (Cr (VI) ) (PBB) (PBDE) Metal parts o o o o o o Circuit modules o o o o o o Cables and cable assemblies o o o o o o Plastic and polymeric parts o o o o o o o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in 2011/65/EU and SJ/T11363-2006. x: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in 2011/65/EU and SJ/T11363-2006. Radio Specifications RF technologies Cellular Frequency* 2G, 3G, 4G 4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B28 LTE TDD: B40 3G: WCDMA: B1/B2/B5/B8 2G: GSM: B2/B3/B5/B8 4G: LTE FDD: B2/B4/B5/B13/B17 3G: UMTS: B2/B5 4G: LTE FDD: B1/B3/B5/B7/B8/B20 LTE TDD: B38/B40/B41 3G: WCDMA: B1/B5/B8 2G: GSM: B3/B8 4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/ RT025_HM_R3000_Lite Oceania South America USA EMEA EMEA 2/10 Robustel R3000 Lite Hardware Manual B13/B18/B19/B20/B25/B26/B28 LTE TDD: B38/B39/B40/B41 3G: WCDMA: B1/B2/B4/B5/B6/B8/B19 2G: GSM: B2/B3/B5/B8 4G: LTE FDD: B1/B3/B8/B18/B19/B26 LTE TDD: B41 3G: WCDMA: B1/B6/B8/B19 4G: LTE FDD: B1/B3/B7/B8/B20/B28A 3G: WCDMA: B1/B8 2G: GSM: B3/B8 Max RF power 35 dBm@GSM, 25 dBm@WCDMA, 25.7 dBm@LTE * May vary on difference models. Japan EMEA Simplified EU Declaration of Conformity We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is available at the following internet address: www.robustel.com/certifications/ FCC Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. IC Declaration of Conformity This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1)This device may not cause interference. (2)This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L' appareil ne doit pas produire de brouillage; (2) L' appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d' en compromettre le fonctionnement. Radio Frequency Exposure Statement for IC This device complies with IC exposure limits set forth for an uncontrolled environment. This device shall be installed and operated with minimum distance 20cm between the radiator & body. Cet équipement est conforme aux limites d'exposition IC définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et la carrosserie. RT025_HM_R3000_Lite 3/10 Robustel R3000 Lite Hardware Manual Related download link Find more product documents or tools at: www.robustel.com/en/documentations/ Technical Support Tel: +86-20-82321505 Email: support@robustel.com Web: www.robustel.com Document History Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions. Date July 28, 2022 Firmware Version Document Version Change Description 5.0.0 1.0.0 Initial release. RT025_HM_R3000_Lite 4/10 Robustel R3000 Lite Hardware Manual Overview The Robustel Industrial Dual SIM Cellular VPN Router (R3000 Lite) is a rugged cellular router offering state-of-the-art mobile connectivity for machine to machine (M2M) applications. R3000 Lite is a powerful router developed from RobustOS, a Robustel self-developed and Linux-based operating system which is designed to be used in Robustel hardware routers. Package Checklist Before commencing installation ensure your package has the following components: Device 3PIN Terminal Block RCMS Card Quick Start Guide Card Mounting Kit (Optional) Cellular Antenna (Optional) Power Supply (Optional) Ethernet Cable (Optional) Note: The accessories could be different on specific order. Panel Layout (May Vary on Different Models) RT025_HM_R3000_Lite Top View Bot 5/10 Robustel R3000 Lite Hardware Manual Interface Descriptions 1. LED Indicator. Name Color Status Description RUN Green On, fast blinking Router is powered on (System is initializing) (250ms blink time) On, blinking Router starts operating (500ms blink time) Off Router is powered off On, solid Main Card is being used USR-SIM Green On, blinking Backup card is being used Off NO SIM card USR-NET Green On, solid Network is joined successfully and worked in an optimum one On, blinking Network is joined successfully but worked in a lower-level than standard Off Network is not joined or joining USR-OpenVPN Green On, solid OpenVPN connection is established Off OpenVPN connection is not established USR-IPsec Green On, solid IPsec connection is established Off IPsec connection is not established PPP Green On, solid Link connection is established Off Link connection is not established Green Three lights are solid green High signal strength (21-31) is available Two lights are solid green Medium signal strength (11-20) is available One light is solid green Low signal strength (1-10) is available Off No signal When the network is disconnected, those three signal LEDs are designed as a binary combination code to indicate a series of error report. Blinking: 1 Off: 0 bit2 bit1 bit0 0 0 1 AT command failed 0 1 0 no SIM card detected 0 1 1 need to enter the PIN code 1 0 0 need to enter the PUK code 1 0 1 registration failed 1 1 0 module error 1 1 1 not support the module Note: You can choose the display type of USR LED. For more details, please refer to RT123_SM_RobustOS Software Manual Service > Advanced > System >System Settings > User LED Type. 2. USB Interface. Function Operation Firmware upgrade USB interface is used for batch firmware upgrading, but cannot be used for sending or receiving data from slave devices which connected to it. You can insert a USB storage device into the router's USB interface, such as a U disk or a hard disk. If there have a supported configuration file or a router firmware in this USB storage device, the router will automatically update the configuration file or the firmware. For more details, see RT123_SM_RobustOS Software Manual. RT025_HM_R3000_Lite 6/10 Robustel R3000 Lite Hardware Manual 3. PIN Assignment 10 11 12 54321 9876 PIN Polarity 10 Positive 11 Negative 12 GND PIN Debug (232) 1 2 3 4 DRXD 5 GND 6 7 8 9 DTXD RS-232 RXD TXD GND RTS CTS RS485 (2 Line) Data+(A) GND Data-(B) Direction -- RouterDevice RouterDevice RouterDevice -RouterDevice RouterDevice RouterDevice 4. Reset Button Function Operation Reboot Press and hold the RST button for 2~ 5 seconds under the operating status. Restore to default Press and hold the RST button for 5~10 seconds, the RUN LED starts blinking quickly, the router will restore to default configuration configuration. Restore to factory Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory default settings default settings. Note: The more details please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset. 5. Ethernet Ports. R3000 Lite Router has one Ethernet port with two LED indicators. The yellow one is link indicator and the green one is speed indicator. For details about status, see the table below. Indicator Status Description Link indicator On, solid Connection is established On, blinking Data is being transferred Off Connection is not established Speed indicator On, solid 100 Mbps mode Off 10 Mbps mode RT025_HM_R3000_Lite 7/10 Robustel R3000 Lite Hardware Manual Hardware Installation 1. SIM Card Installation. Loosen the screws associated with the cover by using a screwdriver and then find the SIM card slot. Press the card with finger until you hear a click and then tighten the screws associated with the cover by using a screwdriver. Put back the cover and tighten the screws associated with the cover by using a screwdriver. 2. Antenna Installation. Rotate the antenna into the antenna connector accordingly. 3. Mounting Kit installation. (Optional) · Wall mounting · DIN rail mounting RT025_HM_R3000_Lite 8/10 Robustel R3000 Lite Hardware Manual 4. Power Supply installation. Following to the color of the head, connect the cable marked red to the positive pole through a terminal block, and connect the yellow one to the negative in the same way. Note: The range of power voltage is 9 to 36V DC. 5. Connect the Router to a Computer. Connect an Ethernet cable to the port marked ETH at the bottom of the R3000 Lite, and connect the other end of the cable to your computer. RT025_HM_R3000_Lite 9/10 Robustel R3000 Lite Hardware Manual Login to the Device 1. Connect the router's Ethernet port to a PC with a standard Ethernet cable. 2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure "Use the following IP address". 5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device. 6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting. 3. To enter the gateway's web interface, type http://192.168.0.1 into the URL field of your Internet browser. 4. Use login information shown in the product label when prompted for authentication. 7. The more configuration details please refer to RT123_SM_RobustOS Software Manual. (END) w RT025_HM_R3000_Lite Support: support@robustel.com Website: www.robustel.com ©2022 Guangzhou Robustel Co., Ltd. All rights reserved. Subject to change without notice. 10/10