Dyson Purifier Hot+Cool Gen1 User Manual
Model: Dyson Purifier Hot+Cool Gen1 (SV12 JN.00000 PN.000000-00-00)
Introduction
This user manual provides comprehensive instructions for your Dyson Purifier Hot+Cool Gen1 fan heater. It covers assembly, initial setup, operation of various modes, continuous monitoring, filter replacement, and machine maintenance.
The Dyson Purifier Hot plus Cool Gen1 fan heater features an amplifier loop, a mesh filter cover, a screen below the loop amplifier, and an outer cover release button on the side.
Contents
Assembling your machine
Use both hands to lift your machine out of the box, by its base. Do not lift out by the loop amplifier.
Your Dyson Purifier Hot+Cool Gen1 is supplied with a combined glass HEPA+Carbon filter.
Getting started
Place the remote control on top of the machine with the buttons facing down.
Plug in and switch on.
The air purifier fan heater is shown with the remote control placed on top of the loop amplifier. The standby on/off button is located on the top of the base of the machine.
Key components:
- Shroud
- Shroud release buttons
- Amplifier loop
- Standby on/off button
- LCD screen
- Filters (inside)
Remote Control Layout
The remote control features the following buttons:
- button (top left)
- toggle button (middle left)
- button (below Airflow speed)
- button (bottom left)
- button (top right)
- button (below Information menu)
- button (below Heating control)
- button (bottom right)
Power and continuous monitoring
Stand-by on/off
Press the
button on your Dyson purifying fan heater or remote control to stop your machine. It will continue to monitor the air quality.Continuous monitoring
Continuous monitoring is turned off by default. Once turned on, it will always be active until you turn it off again.
With continuous monitoring turned on, your Dyson purifying fan heater will gather particulate matter and temperature information, which is displayed on the LCD screen.
To turn continuous monitoring on, press and hold the
button on the remote control for 5 seconds. The LCD screen will indicate when continuous monitoring is on or off.Auto mode
Set your Dyson purifying fan heater to Auto mode and the on-board sensors will intelligently adjust the settings of the machine according to the air quality.
- Air quality: Your machine will pause when the target air quality has been reached, switching on again when the air quality levels drop.
- Airflow speed: The airflow speed will increase until the target air quality and temperature have been reached.
The remote control with the Auto mode button [AUTO] below the Airflow speed button on the left.
Airflow speed
Press the
toggle button ? to increase and decrease the airflow speed.The remote control with the Airflow speed toggle button on the left hand side, below the standby button.
Oscillation
Press the
button ? to circulate the air around the room and scroll through the oscillation settings from 0° to 350°.The remote control with the oscillation button on the left at the bottom below the Auto button.
Night mode and Sleep timer
In Night mode, your Dyson purifying fan heater will continue to monitor and respond to changes, but only using its quietest settings – and with its LCD screen dimmed.
Press the
button ? to scroll through the timer options.The remote control with the Night mode and Sleep timer button on the right at the bottom.
Heating and Cooling modes
Press the
button ? to set the required room temperature. Your machine will pause when the temperature set has been reached.Press the
button ❄️ to switch your machine from Heating mode to Cooling mode.The remote control with the Heating mode button on the right, below the Information button. The Cooling mode button is immediately below the Heating mode button.
Changing your HEPA+Carbon filter
Before changing your filter, switch off and unplug your Dyson purifier fan heater.
The remaining filter life is displayed on the screen and will indicate when your non-washable filters need replacing. Press the
button ℹ️ on your remote.You'll need to reset the filter life on your machine after replacement.
Dyson Purifier Hot+Cool Gen1: Supplied with a HEPA+Carbon filter.
To change your HEPA+Carbon filter:
- Push down on the buttons either side of your machine to release the outer cover.
- Push down on the tabs to remove the old filter.
- Push the replacement filter into the outer cover and make sure the tabs click into place.
- Put the outer covers into position on your machine and push firmly until they both click securely into position.
Plug in and switch your machine on, and then reset your filter life.
The air purifier fan heater with the filter covers open, showing a HEPA plus carbon filter located within. Arrows demonstrate that the filter covers need to be assembled onto the base of the machine.
Resetting your HEPA+Carbon filter life
It's important to reset your filter life after you have replaced your filter.
To reset the filter life: Press and hold the
button ? on your remote control.The display on your machine will countdown from five ⏳. The filter life will be reset and your machine is ready to use.
Pressing the Night mode and Sleep timer button on the bottom right of the remote control for 5 seconds.
Looking after your machine
To always get the best performance from your Dyson purifying fan heater, it's important to regularly clean it and check for blockages.
Cleaning your machine
If your machine is dusty, wipe with a damp lint-free cloth.
Look for blockages in the air inlet holes on the filter and the small aperture inside the loop amplifier.
Use a soft brush to remove dust and debris.
Do not use detergents or polishes to clean your machine.
Error codes
If your machine shows an error code, try turning it off and then on again. If this doesn't clear the error code, contact Dyson Customer Care.
For more information and support for your machine, go online: www.dyson.com/support