Instruction Manual for hygiena models including: BAX System Q7, BAX System, Q7
BAX System Q7 - Pathogen Detection - Hygiena
BAX System Q7 Version 4.22.0.10335 Features and Instructions
11 set 2022 — BAX System Q7 software release v4.22 contains several user interface features, new target options, and error logging improvements.
File Info : application/pdf, 12 Pages, 5.58MB
DocumentDocumentGuide | BAX® System Q7 Software Upgrade BAX® System Q7 Version 4.22.0.10335 Features and Instructions BAX System Q7 software release v4.22 contains several user interface features, new target options, and error logging improvements. We strongly recommended that you always install the most recent version as soon as possible for optimal performance. Please read all instructions thoroughly and ensure all required prerequisites are confirmed prior to prior to beginning installation of the software update. If you currently have a WIN7 computer system, please contact diagnostics.support@hygiena.com or your local Hygiena® representative for upgrade support. This release is NOT applicable for WIN7 systems. Software Updates and Features for Release v4.22.0.10335 for WIN10 ONLY New Assays with Result Interpretations: foodproof® Salmonella Genus plus Enteritidis & Typhimurium Detection LyoKit foodproof® Salmonella plus Cronobacter Detection LyoKit foodproof® Enterobacteriaceae plus Salmonella Detection LyoKit foodproof® Vibrio Detection LyoKit foodproof® Yeast and Mold Quantification LyoKit foodproof® Aspergillus Detection LyoKit microproof® Legionella Quantification LyoKit SDS Equipment Driver Improvements Messages and Confidence Levels: All foodproof and microproof assays www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Software Upgrade Instructions: 1. Required Prerequisites: Regional Settings are in English Read/Write Permissions for the below file locations for all users C:\Program Files\MATLAB C:\Program Files (x86)\BAX C:\ProgramData\BAX Q7 System All Power and Sleep Settings are set to Never Obtain HEX Calibration Kit from Hygiena This additional calibration plate is a standalone product and is not included with other calibration kits Please visit the contact us page for ordering and technical support 2. Calibration storage and removal of current software: Back up the system's calibration file Select Operations > BAX Maintenance > Export Calibration from the menu bar Navigate to a new folder in which to store the backup file and click Save Name the calibration file (example: Q7Cal_date.bqc) Uninstall the previous version of the BAX Q7 application Navigate to Windows Settings and select Apps www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Click on BAX System Q7, select Uninstall, and agree (click Yes) on next window to initiate removal If updating from 4.21, removal of MATLAB is not required. If updating from any previous versions, click on the MATLAB application, select Uninstall, and click Agree on next window (this may take several minutes) Restart computer BEFORE continuing to step 3 www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Software Installation Instructions for Steps 3 and 4 3. Download 4.22.0.10335 software by clicking this link or the button from the BAX Q7 Page Transfer download to a memory/USB stick if computer doesn't have internet access Click on the Q7 4.22.0.10335 icon and the program will automatically start execution of install. A windows protect screen may pop-up. Select More Info, then select Run Anyway. On the next pop-up, select Yes to allow install to begin 4. MATLAB updates will install first. Follow prompts below and select the default responses: www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade In case this install error occurs: VCRUNTIME140.dll was not found. (shown below) Please download and install the patch: vc_redist.x64.exe from https://www.microsoft.com/en-us/download/details.aspx?id=52685. The install will end when you click OK. After installing this patch, MATLAB Installation is continued www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade 5. Following MATLAB installation, the BAX Q7 application install will initiate. Read the prompts carefully. Choose the default responses. Welcome Window click Next www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Calibration File Warning ENSURE YOU HAVE BACKED UP THE CALIBRATION FILE Check box and click Next License Agreement Check Accept Terms box and click Next www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Custom Setup Click Next Password Protection BAX default is disabled password protection. Choose an option for your lab, then click Next www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade Ready to Install Program Click Install Installing BAX System Q7 Software During installation, an Error Log Reporting window will pop-up. We recommend NOT checking the box so the system can collect software and/or hardware errors in the Log Files to assist Diagnostics Support in troubleshooting. However, please review and decide what is appropriate for your lab. Select Next to complete install www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade InstallShield Wizard Complete Select Finish Click on the desktop icon to initiate program. New open screen will have software version 4.22.0.10335 Enter Instrument Name and Serial Number This will appear on reports and should be utilized www.hygiena.com DIAG-INS2050-REVA Guide | BAX® System Q7 Software Upgrade 6. CHECK system's calibration (NEW FEATURE) From the menu bar, select Diagnostics > Calibration to open the Q7 Calibration Diagnostics window Click the Check Calibration button to determine the status: If calibration is available, no further actions are needed If calibration is NOT optimal or NOT found: Import the backed-up calibration file by selecting Operations > BAX Maintenance > Import Calibration from the menu bar and selecting the backed-up calibration file from step 2 To utilize any foodproof assay, additional calibration using the HEX calibration kit must be performed. Please follow the onboard instructions in the BAX Software to perform calibration. 7. Ready to perform BAX System Analysis Define proper targets that are used in your lab by selecting View > Select Targets > then in window, highlight targets being used, and then use arrow buttons to move targets from Define in System to Available for Selection window www.hygiena.com DIAG-INS2050-REVA