50W Single Output Switching Power Supply

RS-50 series

 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

 Features :
Universal AC input / Full range

User's Manual

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

LED indicator for power on

100% full load burn-in test

All using 105 long life electrolytic capacitors

Withstand 300VAC surge input for 5 second

High operating temperature up to 70

Withstand 5G vibration test

No load power consumption<0.5W

High efficiency, long life and high reliability

3 years warranty

AS/NZS62368-1 GB4943.1

UL62368-1

Bauart gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1 IEC62368-1

TPTC004

MODEL

RS-50-3.3

RS-50-5

RS-50-12

RS-50-15

RS-50-24

RS-50-48

DC VOLTAGE

3.3V

5V

12V

15V

24V

48V

RATED CURRENT

10A

10A

4.2A

3.4A

2.2A

1.1A

CURRENT RANGE

0 ~ 10A

0 ~ 10A

0 ~ 4.2A

0 ~ 3.4A

0 ~ 2.2A

0 ~ 1.1A

RATED POWER

33W

50W

50.4W

51W

52.8W

52.8W

RIPPLE & NOISE (max.) Note.2 80mVp-p

80mVp-p

120mVp-p

120mVp-p

120mVp-p

200mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

3V ~ 3.6V

VOLTAGE TOLERANCE Note.3 ±3.0%

LINE REGULATION Note.4 ±0.5%

LOAD REGULATION Note.5 ±2.0%

4.75 ~ 5.5V ±2.0% ±0.5% ±1.0%

10.8 ~ 13.2V ±1.0% ±0.5% ±0.5%

13.5 ~ 16.5V ±1.0% ±0.5% ±0.5%

22 ~ 27.2V ±1.0% ±0.5% ±0.5%

42 ~ 54V ±1.0% ±0.5% ±0.5%

SETUP, RISE TIME

500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

60ms/230VAC 14ms/115VAC at full load

VOLTAGE RANGE

88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)

FREQUENCY RANGE

47 ~ 63Hz

INPUT

EFFICIENCY(Typ.)

78%

83%

84.5%

86%

88%

89%

AC CURRENT (Typ.)

1.3A/115VAC 0.8A/230VAC

INRUSH CURRENT (Typ.) COLD START 33A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

OVERLOAD PROTECTION
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

3.8 ~ 4.45V

5.75 ~ 6.75V

13.8 ~ 16.2V

17.25 ~ 20.25V

Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve")

20 ~ 90% RH non-condensing

-40 ~ +85, 10 ~ 95% RH

±0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes

27.6 ~ 32.4V

55.2 ~ 64.8V

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 , EAC TP TC 004, CCC GB4943.1 approved

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

(Note 6) EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020

EMC IMMUNITY MTBF

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 2956.7K hrs min. Telcordia SR-332 (Bellcore) ; 575.2K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION PACKING

99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.94CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RS-50-SPEC 2024-02-23

Downloaded from Arrow.com.

50W Single Output Switching Power Supply
Mechanical Specification

RS-50 series
Case No. 905B Unit:mm

36

2-M3 L=4 51.5

9.5

3.5

1
2
3 5.5
4
5

97

8.2

55.5

7 17.5 28 36

20.5

55

3.5

4.5

89

99

6.5

87

3.5

2-M3 L=4

18

74

3.5

Block Diagram

Terminal Pin No. Assignment

Pin No. Assignment Pin No.

1

AC/L

4

2

AC/N

5

3

FG

Assignment DC OUTPUT -V DC OUTPUT +V

fosc : 60KHz

I/P

EMI FILTER

RECTIFIERS &

POWER SWITCHING

RECTIFIERS &

FILTER

FILTER

+V -V

FG

DETECTION

CIRCUIT

O.L.P.

CONTROL

O.V.P.

Derating Curve

Output Derating VS Input Voltage

100 80 60 40 20

-25

0

10 20 30 40 50 60

70 (HORIZONTAL)

-25

0

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
88 95 100 115 120 140 160 180 200 220 240 264
INPUT VOLTAGE (VAC) 60Hz

File Name:RS-50-SPEC 2024-02-23

LOAD (%) LOAD (%)

Downloaded from Arrow.com.



References

Acrobat Distiller 9.0.0 (Windows); modified using iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version)