Instruction Manual for DI models including: DI-M204, DI-M204 Microwave Radar Sensor, Microwave Radar Sensor, Radar Sensor, Sensor, DI-M204G, M-204G
DI-M204 Mikrobangų jutiklis (jungiklis) automatinėms durims
1 Safety Instruction 2 Name of related parts Operation Instruction. M-204G Microwave Sensor EMC TESTED NO.:BSTDG 1001430419 26-C 3 Installation 4. Finish the cable connection and get on power. 6.Cover With The Lid
EMC TESTED NO.:BSTDG 1001430419 26-C Operation Instruction M-204G Microwave Sensor . 1 Safety Instruction Related part should be operated under low voltage condition. All installation process and maintainance should be carried out by the supplier 3.Adjustment of detection direction ( Adjust Direction of front and back/Left and Right flexibly) Adjusting angle of Plain aerial to get different detection distance and range 30 15×2range 2 Name of related parts JST connection Red:24V power cable Yellow: Relay COM/NO 3 Installation The indicator will shin for few seconds when starting. When object is detected by sensor , indicator lights up. Sensitivity potentiometer Fluctuation up and down NOTE: Rotation left and right Fluctuation up and down, Rotation left and right Initial setting is 45degree by factory. All the parameters above are only for reference, detection height is 2.2M. Detection range will be different because of the making material of door and ground , please adjust the sensitivity by the knob mentioned above. When it is adjusted to 60 degree, the detection range is the widest ,door will keep on closed and open all the time. 1.Please do the installation in the proper position,Installation height within 3.5m. Please arrange hole)mm(on the installation module. And hole (12m) for insetting guide line 2.Please connect the signal cable with the terminal of automatic door. Brown and Yellow cable: AC/DC12V-24V Green and White cable: Signal output COM/NO 5 Special Note 3.Take the outer cover off , and fix the screws. 4. Finish the cable connection and get on power. 5.Please set the detection range and disjunctor accordingly 6.Cover With The Lid 4 Adjustment( Get on power) 1.Detection range as below shown MIN 1m MAX 2m 2 1 0 1 2 NOTE: Please stand out of the detection range around 5S to ensure the sensor has enough time to finish the self-adjustment. 2.Sensitivity Adjustment Detection Range MIN:0.5*0.4M MAX:4*2M Select different detection range by adjusting sensitivity knob Position should be Do not place into Moving object should Fluorescent should fixed tightly to avoid board or other material. be avoided. be avoided. vibrating Do not touch directly, ESD Protection is necessary 6 Failure cause Symptom Cause Method Door&Indicator lose failure Did not get on power Check cable connection & power supply Door keep on closed and open Sensor detected the movement of autodoor;vibration of movement 1.adjust angle 2.check the position 3.adjust sensitivity Door do not close Red indicator lose failure 1.Switch of autodoor controller lose failure 2.incorrect position 3.Incorrect output of sensor Check the switch of autodoor controller &setting of ouput. Door keeps on moving when it rains Sensor detected the actions of rain Adopt waterproof accessories 7 Parameter Technology:Microwaveµwave disposer Frequency:24.125GHz Installation Height:4M(MAX) Installation Angle:0-90 degree(lengthways) -30 to +30(lateral) Detection Mode:Motion Min detection speed:5cm/s Power: 2W(VA) Detection range:8m*4m(Installation Height 2.2M) Maximum voltage:42AC-60V DC Maximum Current:1A Maximum switching power:30W(DC)/60VA(AC) Retention time:0.5S Protection class:IP54 Sheating material: ABS plastic Color: Black/silvery Anti-interference performance:R&TTE 1995/5/EC,EMC 89/366/EEC Power Voltage12V to 30V AC+/-10% ) H z 5 0 to H z 6 0 (12V to 36V DC Size120mm(W)×80mm(H)×50mm(D)Corel PDF Engine Version 14.0.0.701