Instruction Manual for Multimic models including: MDU-100X, MDU-200X, MDU-100X Display Unit Instrument Connecting Bluetooth, MDU-100X, Display Unit Instrument Connecting Bluetooth, Unit Instrument Connecting Bluetooth, Instrument Connecting Bluetooth, Connecting Bluetooth, Bluetooth
Display unit for the instrument connecting Bluetooth MDU-100X/200X English Manual (ver.1.20) Thank you very much for purchasing MDU series. Before using, read this instruction manual carefully
MDU-200X Display unit for the Bluetooth connecting instrument
File Info : application/pdf, 2 Pages, 182.98KB
DocumentDocumentDisplay unitfor the instrument connecting Bluetooth Warning In cases of misused, it causes serious injury to the body or danger to the life of the end-user. Pay extra attention when used. Caution If the unit becomes dirty, use a soft cloth with a moistened water or a neutral detergent in a small Contents Bluetooth version Receiving interval Specification Bluetooth4.2 class2 Approx. 0.5s intervals MDU-100X/200X Cautions If it is misused, it causes damage to the instrument. amount andwipe lightly. Do not use abrasives or Power Supply AAA alkali Battery x 3 organic solvents. Communication standby: English Manual (ver.1.20) Thank you very much for purchasing MDU series. Before using, read this instruction manual carefully and use it correctly. In order to refer the instruction manual anytime, keep it always at a safe and available place. MULTI MEASURING INSTRUMENTS CO., LTD. Address; Akihabara Murai Building 7-F, 1-26 Kanda Sakuma-cho, Chiyoda-ku, Tokyo,101-0025, JAPAN Tel; +81-3-3251-7016 Fax; +81-3-3253-4278 Webpage; www.multimic.com/e Warranty Sheet In a case of failures, due to manufacturing defects, contact the shop/ distributor where you purchased Or it disturbs the function of the instrument as specified. Please note that this device cannot be used in an environment where it is not available to connect with the measuring instrument by Bluetooth connection. The measuring instrument cannot pair with a smartphone while using this device. Please note that it cannot be used with "Multi-Tracer" at the same time. Please note that it is not possible to connect two measuring instruments with this device at the same time. Do not use a measuring instrument made by another company by connecting it to this instrument. The correct value will not be displayed and may cause an accident. Do not pair with the measuring instrument made by other company. The correct value will not be displayed and it may cause an accident. Warning There is a risk of electric shock. Never use it in direct contact with the power lines. It may cause an accident. When using a measuring instrument with connecting this device in a high-voltage circuit, be sure to equip this device to the insulating rod that secures an Do not use if water gets inside or its surface is wet. Power Do not wash by immersing it in water or in similar liquid. consumption Do not dry it in a microwave oven or in similar heaters. Do not expose to direct sunlight for a long time. It may cause deterioration of its cover. It is NOT dustproof or waterproof structure. Do not use or store in environment with harmful smoke or gas containing salts, sulfur, ammonia components or in ultraviolet light, etc. It may cause malfunction. Some kinds of oil may deteriorate the cover part, and it may cause malfunction. Wipe oil away lightly with a soft cloth, moistened with water or a neutral Display specification detergent, a small amount. Refrain from storing it in an environment where it has mold etc. Do not store it in an environment that exceeds the specified operating temperature and humidity. Do not roast this unit with a firearm such as a lighter Data hold Cannot be used underwater. function Do not give a strong shock to the unit. Do not use as a lightning rod. Max hold function Do not use as a hammer etc. (MDU-200X, Before measurement, be sure to pair with a measuring for HCL-36UX instrument. Without the pairing, it does not show and ALCL-80X) Approx.12mA Communication connection: Approx.6mA LCD display Displayable max 9999 count display with symbol and unit * Units and functions and symbol display to measurement contents differ depending on the connected measuring instrument. When the battery voltage drops below 3.5V, the "battery" mark on the display lights up. * If the battery voltage drops below 3.3V, the LCD display will fade. 100X=Hold/200X=Record switch are pressed for holding value. To release the data hold, press the same switch again. To press the Record switch again under data holding, MAX hold function is available. Press again to release the hold. product or directly inform us. The warranty period enough insulation distance according to the each the reading values. Press the Record switch during of this product is one year from the date of purchase. specified live-working safety regulations. Safety work is ensured by an insulating rod when 2s at each hold. Warran ty [User Inform ation] Street Address: When mounting this device on the insulating rod, secure firmly with a fastener to prevent it from falling off. *If dropped, the shock may cause used in a high voltage circuit., it is recommended to wear insulation gloves. Perform the work, according Max 4 data can be recorded. Recoreded data can be saved to each operation rule. Record function onto the 4 data spaces every time Full Name: Model :MDU-100X/200X Seria l number : WDiastrrriabnuttyorp/esrhioodp:1n5ammoen: th after shipment by factory This warranty sheet is required for after-sales service. Note This your warranty sheet is not to be reissued. For convenience, fill in above information and damage to workers or surrounding facility. The symbol marks are shown below: (MDU-200X) Never hit it to ground after use. It may cause malfunction. Check whether the surrounding environment and work is safe before use. High voltage circuits are extremely dangerous. For user without specialized knowledge, avoid Warning In order to protect the human-body and the unit, refer to the instruction manual and pay close attention. In order to avoid accidents or malfunction pressing the Storage switch. Data can be retained even when power off. To delete data, hold down the Storage switch and press Power after power off. keep it with the end user of the instrument. Warranty policy 1. In cases of a malfunction occurs during normal use, within the warranty period, it is to be repaired free of charge, based on the warranty provisions. 2. The warranty sheet is not to be reissued. using the measuring instrument connecting with this device near high voltage circuits. Even while operating a smartphone or a this device, keep the safety work sufficiently. If the insulation rod tumbled, it may lead to an unexpected accident. Cautions caused by incorrect use, refer to the instruction manual. Harmonics current Each time the Storage switch is display function pressed, the RMSfundamental The symbol indicates that the Bluetooth (MDU-200X, third harmonic measurement wireless technologies are employed. for ALCL-80X) value is displayed. 3. Even during the warranty period, under the following Avoid using this device in near electric circuit that Trademarks (TM, (R) mark, etc. are not specified in this manual.) When the APO mark is lighting, circumstances, items are not to be repaired free of charge. A) Failure due to improper handling B) Failure due to handling and use, outside design specifications C) Failure due to modifications or repairs other than our company or those commissioned by our company exceeds the using voltage range specified by each connected measuring instrument. · Bluetooth is a trademark of Bluetooth SIG,Inc. Multi Measuring Instruments Co., Ltd. uses it under a license agreement with the company. Due to safety reasons, do not use under abnormal · Android and Google Play are trademarks of Google LLC condition, such as raining, lightning, eruption, · The iOS trademark is used under a license agreement with Cisco Auto power off function the power is automatically turned off approx.30min after the last switch operation. This function is disabled during D) Other failures not considered to be manufacturing defects For Safe Use storm, earthquake or tsunami. Do not use at uninsulated conductors or at bus bars Systems, Inc.USA. · iPhone, iPad, iPad mini and iPod Touch are trademarks of Apple Inc., registered in the US and other countries. Do not push into a covered electric wire, larger · App Store is a service mark of Apple Inc. Weight communication connection (when the APO mark is off). 180g(with batteries inside) than the inner diameter of the unit. In order to use this instrument safely, follow this Do not use on the instrument or the insulating rod instruction manual strictly and attention to the with damages. Specification Size 76*97*50.4mm following cautions and warnings described below. Name of parts and function * If measured value exceeds the measurement range These Units requires Bluetooth communication. of the connected measurement instrument, it will be For the dedicated application "Multi-Tracer" in order Front Side MDU-100X MDU-200X Main Body displayed as "OL". to display, record or storage measurements, download Data hold function(Common to MDU-100X/200X) and install Multi-Tracer at APP Sore or at Google MDU-100X presses the Hold switch, MDU-200X play in prior. In order to download Multi-Tracer, presses the Record switch. The DH mark lights up because it requires each ID, obtain necessary ID in Screw on the LCD and holds the measured value when advance. For communication costs related to the pressed. To release it, press the same switch again. download, it is not our responsibility. Proceed the Battery Cover MAX hold function(Only MDU-200X for HCL-36UX download as it is necessary. For obtaining necessary and ALCL-80X) ID, communicate with customer-center of a dedicated Warning By pressing the Record switch during data hold, MAX mobile-phone company. In addition, we are not hold is enabled and only the max value is displayed. responsible for any problems or costs related to Possible electrical shock Press the same switch again to unlock. downloading. Proceed download and install based Back Side Common design Name of parts Function Hold switch Holds the measured value Power switch Power On/ Off. MDU-200X is also used to delete all recorded values Record switch Used to hold and record measured values Storage switch Used to select 4 storage spaces and also used to delete all recorded values LCD Displays the symbol and the battery status with measured value sent from the connected measuring instrument Main Body To store PCB etc Fastener hole for Passing the velcro fastener for fixing fixing the insulating rod Battery Cover Open when replace batteries. Equipped with the non-slip rubber for fixing to the insulating If opening the battery-cover, return to the original position. Harmonics current display function(Only MDU-200X on responsibility of its user. Do not apply to conductors with the battery cover open. for ALCL-80X) Low Battery Indication; when low battery, the Each time the Storage switch is pressed, the RMS Caution battery mark lights up. fundamental third harmonic measurement value Connection with "Multi-Tracer" is displayed(The first digit of the upper right two digitsThis product has a low power data communication 1: RMS, 2: fundamental, 3: third harmonic current). system based on the Radio Law. measuring instruments Record function (applicable only to MDU-200X) (Built-in equipment; EYSHCN: 001-A10745) Presses the Record switch for 2s under holding data,The communication range depends on the surrounding <1> Turn on the power of the "Multi-Tracer" measuring you can record the measured value in the each space environment such as other radio waves and devices. instrument. If the instruments have the " " switch, of the No.1~4.When it is recorded normally, the "M"This product uses communication frequencies of press this switch. If not, move to <2>. mark lights up. By pressing the Storage switch, changes the 2.4 GHz band. If another wireless devices are <2> Press the Power switch of these units to turn the recording spaces No.1~4 in order. Press again the using similar communication frequencies near this on the power. Record switch to return to the measuring state. product, it may disturb wireless communication of <3> Pairing is complete when the " " mark lights up * Changes the storage space number by pressing the both devices. Radio-wave interference may occur. on the LCD of these units. In the case of connecting Storage switch unless the data were not deleted, the In this case, stop other wireless devices or change with "Multi-Tracer", register the measuring instrument measured values data in each space can be displayed. the place where this product is used to avoid radio- to "Multi-Tracer" at first. After registration, select the * If communication is disconnected while operating the wave interference. measurement point on the map and start to measure. record function, the " " mark blinks and the APO markMulti-Tracer" is free of charge. However, the internet You can record and keep measurement data on the lights up. connection fee is on user's payment. server through "Multi-Tracer". If you do not need to * To delete the data, presses the Power switch whileThe Bluetooth communication function may not record data, you can also choose a mode that just pressing the Storage switch when the power is off, and works on all mobile terminals. Multi-Tracer" may measures. These Units and "Multi-Tracer" cannot the CLR mark will be displayed. When CLR mark appears, not work on all mobile devices. Use of devices with be connected with the Multi-Tracer measurement all the measured value data recorded in No.1~4 will radio-communication requires approval in the country instruments together at same time. This connection be deleted. After finishing the measurement work, of use, and use of the instrument in a country or a takes priority the one that was quickly paired with move the measurment instrument away from the region may be subject to penalty as a violation of the Multi-Tracer measurement instruments. measurement target, ensures the safety of the surro- related laws. Please close "Multi-Tracer" when using this unit. undings, and then press the power switch on the Attention:Some "Multi-Tracer" compatible measuring measurwement instrument to turn off the power. After Sales Service instruments cannot be connected with this unit. Furthermore, checks whether these unit still are Usage instructions connected or disconnected pairing on these unit LCD. In the unlikely event of failure, please contact your distributor or our agent at where you have purchased. rod Press the power switch while the measuring instrument Caution Handling Instruction to be connected is waiting for connection. Then the When an overcurrent and/or over voltage are APO mark lights up. When the connection is com- applied on these units, then it may cause damages Replacing Batteries Be sure to power-off and take off the battery-cover on the back-side and place batteries in right dire- ctions. pleted, the " " mark lights up on the LCD and the to these units. APO mark lights out, the LCD will be able to be This instrument is a precision mechanical equip- displayed measurement value. ment. When handling, be careful not to apply * If the connection is not completed, the " " mark shock, vibration or excessive stress. Place the battery-cover and secure the cover will blink on the LCD and APO mark still be lighting screws with (+) screw driver. up, and the measured value display part is displayed Bluetooth® function as "---", then please try to connect again. If you contact a distributor or agent which are different from the one you have purchased, it may be difficult to provide our after-sales service. Please be noted. When you are sending the item for repair, put it in a dedicated packaging box enclosed for this delivery, wrap it sufficiently not to be opened or damaged easily, along with the warranty card including information clearly describing the address, name, and details of the failure, and return to designated retailer/agent where you have purchased the item.