Instruction Manual for Basics models including: MT01-1325-069023-CT, MT01-1325-069023-CT 5V Wand Motor, 5V Wand Motor, Wand Motor, Motor
12 mars 2024 — CAUTION. • Do not expose motor to moisture or extreme temperatures. • Do not allow children to play with this device. • Modification of motor in any shape ...16 pages
Basics - Automate US
Index of /assets/uploads/2024/02
File Info : application/pdf, 16 Pages, 3.01MB
DocumentDocument5V Wand Motor Motor programming instructions Electronic Limit Selectable Speed Battery Powered Favorite Position USB Charge USE THIS DOCUMENT WITH THE FOLLOWING MOTORS: PART NUMBER MT01-1325-069023-CT MT01-1325-069024-CT DESCRIPTION 5V ZERO LI-ION 1.1NM WAND CT20 Ø25/5V/28RPM S45 5V ZERO LI-ION 1.1NM WAND CT20 Ø25/5V/28RPM SKY AUTOMATETM | Wand Motor & Wand Control offers a wire-free, rechargeable, easy to program and use solution to suit a large range of applications. The favorite position feature allows a pre-set position to be recalled for precise alignment at a desired mid window position. FEATURES: · Lithium-ion battery powered · Electronic Limits · Selectable Speed · Favorite Position · USB Charge · Battery Check Function · Child Safe Wand Control - [Sold separately] MT01-1325-069024_PRGM_DEC_2023 A Division of Rollease Acmeda SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer's liability and warranty. CAUTION · Do not expose motor to moisture or extreme temperatures. · Do not allow children to play with this device. · Modification of motor in any shape or form will void warranty. · Use or motor for other than intended use as outlined in this manual will void warranty. · For use within tubular blinds. · Ensure correct crown and drive adapters are used for the intended system. · Keep antenna straight and clear from metal objects · Do not cut the antenna. · Use only Rollease Acmeda hardware. · Ensure torque and operating time is compatible with system weight. · Do not expose or immerse motor in water or install in humid or damp environments. · Motor only to be installed horizontally. · Do not drill into motor body. · The routing of cable through walls shall be protected by isolating bushes or grommets. · Ensure power cable and antenna is clear and protected from moving parts. · Do not operate if cable or power connector is damaged. Important safety instructions to be read prior to operation. · It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced mental capacity, or lack of experience and knowledge should not be allowed to use this product. · Keep remote controls away from children. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep motor away from acid and alkali. · Do not force the motor drive. · Keep clear when in operation. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 2 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda CONTENTS 1 ASSEMBLY 4 2 OPERATION NOTE 5 3 BUTTON DESCRIPTION 5 4 INITIAL SETTINGS 6 4.1 Factory Settings 6 4.2 Change Motor Direction of Rotation 6 4.3 Set Limits 7 5 ADJUSTING LIMITS 8 5.1 Adjust Upper Limit 8 5.2 Adjust Lower Limit 9 6 FAVORITE POSITIONING 10 6.1 Setting a Favorite Position 10 6.2 Send Shade to Favorite Position 10 7 STEPPING MODE 11 7.1 Enter Stepping Mode 11 7.2 Exit Stepping Mode 11 8 ADJUSTING SPEED 12 8.1 Increase Motor Speed 12 8.2 Decrease Motor Speed 12 9 BATTERY CHECK FUNCTION 13 9.1 Send Shade to battery charge level 13 10 RESTORE FACTORY SETTINGS 13 11 MOTOR LED - COLOR STATUS 14 12 TROUBLE SHOOTING 14 A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 3 1 ASSEMBLY Please refer to Rollease Acmeda System Assembly Manual for full assembly instructions relevant to the hardware system being used. Step 1. Cut roller tube to required length. Step 2. Ensure roller tube is clean and free from burrs. Step 3. If is required, fit the crown, drive and bracket adapters. Tube must be close fitting with chosen crown and drive adapters. Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive, and bracket adapter kits. Step 4. Slide Motor into tube. Insert by aligning keyway in crown and drive wheel to the tube. Crown Drive Retaining Clip Step 5. Installation: Assemble motor and tube assembly to the bracket. Step 6. Attach the Wand to the Motor: Ensure power connector is attached to motor head. 4 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda 2 OPERATION NOTE This motor has a 8.4V built-in Li-ion battery pack with integrated charge management. · Before first use ensure that the motor is fully charged, indicated by a solid blue LED on the motor head. · If battery is getting low, the LED on the motor will flash 8 times when the motor starts moving. · Ensure limit positions are set before use to avoid damaging the motor or shade. · To prevent damage to the motor or shade, ensure no objects are blocking the free movement of the · shade. · On first use and after factory resetting, the motor is in a `sleep mode' to conserve battery life. Please · press the P1 button on the motor head for 2 seconds, causing the motor to jog. The motor is now out of · `sleep mode' and able to detect a wand control. · To indicate that a wand control has been successfully connected, the motor will jog. Type C Charging Port IMPORTANT Ensure that the wand connector cable are kept clear of fabric. 3 BUTTON DESCRIPTION MANUAL KEY: UP STOP DOWN A Division of Rollease Acmeda P1 button on the Wand Type-C Charging Port 5V-2A P1 button on motor head. AutomateTM Programming Instructions | Basics Wand Motor | 5 4 INITIAL SETTINGS 4.1 Factory Settings To check travel direction of shade,press UP or DOWN on controller. If no response from the motor, press P1 (on motor head only) for 2 seconds to wake the motor from sleep mode. Press UP button Press DOWN button Press STOP button to stop motor OR OR 1 SEC QUICK PRESS = Step 2 SEC LONG PRESS = Continuous Travel IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. 4.2 Change Motor Direction of Rotation OPTION 1: If the shade direction needs to be reversed: press and hold the UP & DOWN arrow together for 2 sec until the motor Jogs. Press & Hold UP and DOWN Button Motor Response Approx. 2 SEC OPTION 2 (Only if the limits are all set): To reverse shade direction, press the P1 Button for 10 seconds. Hold P1 button Motor Response Approx. 10 SEC 6 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda 4.3 Set Limits Move the shade into the desired highest location. Hold UP button until the shade is in desired position Press STOP button shade is at the desired position. OR OR Hold UP & STOP button Motor Response Motor Stops Motor Response Approx. 2 SEC Move the shade into the desired lowest location. Hold DOWN button until the shade is in desired position Press STOP button shade is at the desired position. Hold DOWN & STOP button OR OR Motor Response Motor Stops Motor Response Approx. 2 SEC IMPORTANT The reversal of button directions option is unavailable while setting the Limits. The motor will automatically go to Continuous Travel once the Limits are set. A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 7 5 ADJUSTING LIMITS 5.1 Adjust Upper Limit Hold UP & STOP for 6 seconds to enter Adjustment Mode. Hold UP & STOP button Motor Response Approx. 6 SEC Move the shade into the desired highest location. Press UP or DOWN buttons to move shade OR Hold STOP & UP button Motor Response Approx. 2 SEC IMPORTANT The Upper Limit can NOT be changed if it is currently sitting at the maximum height possible. Lower shade before beginning to change the upper Limit. IMPORTANT After entering the Limit Adjustment Mode, any Favorite Positions that have been saved are deleted and need to be re-programmed. If 4 minutes pass with no button press, the motor will exit the Limit Adjustment Mode and no new positions are set. 8 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda 5.2 Adjust Lower Limit Hold DOWN & STOP for 6 seconds to enter Adjustment Mode. Hold DOWN & STOP button Motor Response Approx. 6 SEC Move the shade into the desired lowest location Press UP or DOWN buttons to move shade OR Hold STOP & DOWN button Motor Response Approx. 2 SEC IMPORTANT The Lower Limit can NOT be changed if it is currently sitting at the lowest height possible. Raise shade before beginning to change the upper Limit. IMPORTANT After entering the limit adjustment mode, any favorite positions that have been saved are deleted and need to be re-programmed. If 4 minutes pass with no button press, the motor will exit the limit adjustment mode and no new positions are set. A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 9 6 FAVORITE POSITIONING 6.1 Setting a Favorite Position Move the shade into the desired position. Press UP or DOWN buttons to move shade Hold STOP button Hold STOP button T< 2 SEC OR IMPORTANT Setting of Favorite position must happen within 16 seconds after first pressing the STOP button 16 SEC Motor Response when Favorite Position is set Approx. 2 SEC Motor Response when Favorite Position is removed Approx. 2 SEC IMPORTANT The Favorite Position can NOT be set at the Upper or Lower Limit. Adjustment of the Upper or Lower Limit will delete the Favorite Position from the Motor and needs to be reset. 6.2 Send Shade to Favorite Position Press STOP button Approx. 2 SEC 10 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda 7 STEPPING MODE 7.1 Enter Stepping Mode Hold P1 button Hold STOP button Hold STOP button Motor Response Approx. 2 SEC Motor Response Approx. 2 SEC Motor Response 2 SEC IMPORTANT In stepping mode, Press UP or DOWN for 2 seconds to step or Long Press for continuous Travel. 1 SEC QUICK PRESS = Step 2 SEC LONG PRESS = Continuous Travel 7.2 Exit Stepping Mode Hold P1 button Hold STOP button Hold STOP button Motor Response Approx. 2 SEC Motor Response Approx. 2 SEC Motor Response 2 SEC A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 11 8 ADJUSTING SPEED 8.1 Increase Motor Speed Default motor mode is the slowest speed. Hold P1 button Press STOP button Press UP button Motor Response Approx. 2 SEC Motor Response Approx. 2 SEC 8.2 Decrease Motor Speed Hold P1 button Press STOP button Motor Response 2 SEC Press DOWN button Motor Response Approx. 2 SEC Motor Response Approx. 2 SEC Motor Response 2 SEC 12 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda 9 BATTERY CHECK FUNCTION 9.1 Send Shade to battery charge level Shade must be at Upper Limit. Hold UP Upper Limit Motor Response Approx. 5 Lower Limit Shade must be at Upper Limit Hold UP for Approx. 5s Percentage of Battery Charge Remaining Percentage Depleted Shade moves to percentage of battery charge remaining 10 RESTORE FACTORYGSETTINGS Hold P1 for 16 seconds to restore Factory Settings. Hold P1 button Motor Response Approx. 16 4 A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 13 11 MOTOR LED - COLOR STATUS LED Color LED Status Description Green LED blinking Green LED will blink when the motor is charging. Green LED solid Green LED is solid when the motor is fully charged. Yellow LED blinking 12 TROUBLE SHOOTING Yellow LED will blink when pressing the motor head button or P button on back of the remote jog indication. Problem The wand LED flashes when the motor is working. The motor is not responding. Cause The battery voltage is low. Battery in motor is depleted. Power Failure. Incorrect Wiring. Motor in Sleep Mode. automateshades.com Remedy Recharge battery with compatible AC adapter. Recharge battery with compatible AC adapter. Check power connector is attached correctly to motor head. Check power connector is attached correctly to motor head. Press and Hold the P1 Button for 2 seconds (On the motor head or on the Wand) 14 | AutomateTM Programming Instructions | Basics Wand Motor A Division of Rollease Acmeda NOTES A Division of Rollease Acmeda AutomateTM Programming Instructions | Basics Wand Motor | 15 ROLLEASE ACMEDA | USA Level 7 / 750 East Main Street Stamford, CT 06902, USA T +1 800 552 5100 | F +1 203 964 0513 ROLLEASE ACMEDA | AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS T +61 3 9355 0100 | F +61 3 9355 0110 16 | AutomateTM Programming Instructions | Basics Wand Motor ROLLEASE ACMEDA | EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 A Division of Rollease Acmeda