Panasonic Premium Inverter Ducted Air Conditioning
Brand: Panasonic
Tagline: QUALITY AIR FOR LIFE
Panasonic Leads the Way
With over 60 years of experience and exporting to more than 120 countries, Panasonic is a leader in global air conditioning. The company holds over 91,539 patents for innovation. Panasonic has produced over 200 million compressors and its residential air conditioners are No.1 in markets like Japan. Panasonic delivers quality air for life.
[Image: Hands gently holding the Earth, symbolizing global reach and environmental consideration.]
[Image: A happy family relaxing together in a bedroom, implying comfort provided by the air conditioning.]
Ducted Air Provides Year-Round Comfort
Panasonic offers ducted air conditioning solutions for homes and medium-sized buildings such as apartments, offices, and restaurants. Systems consist of an outdoor unit and a concealed indoor unit, distributing air via ducting pipes to room vents (floor, wall, or ceiling). These discreet and flexible systems add value to homes, providing comfort and quality air for life, especially in the Australian market.
[Diagram: A floor plan illustrating a ducted air conditioning system. It shows an outdoor unit connected via flexible ducting to an indoor unit, which then distributes conditioned air to various room outlets (air outlets) via ducting pipes. The diagram indicates 'WARM IN WINTER' and 'COOL IN SUMMER' airflow paths.]
Product Line-Up
R32 Compact Model
Capacities: 6.0kW, 7.1kW, 10.0kW, 12.5kW, 14.0kW.
Indoor Unit Models: U-60PZ2R5, U-71PZ2R5, U-100PZ2R5, U-100PZ2R8*[3-Phase], U-125PZ2R5, U-125PZ2R8*[3-Phase], U-140PZ2R5, U-140PZ2R8*[3-Phase].
Outdoor Unit Models: S-60PE1R5B, S-71PE1R5B, S-100PE1R5B, S-125PE1R5B, S-140PE1R5B.
Key Features:
- [R32 Refrigerant]
- Powerful Airflow: Increased by 16% (up to 1400 l/s) for faster room temperature control.
- Max. 200 Pa Static Pressure: Enables use of long ducts for installation in a wide range of spaces.
- Easy Installation: Newly designed duct model can be split into three components, ideal for residential use with aperture size restrictions.
[Image: Various Panasonic indoor and outdoor air conditioning units.]
Compact Outdoor Unit Design: Panasonic's R32 outdoor units are compact and intuitively designed to fit into any space, making installation easy even in tight locations.
[Comparison: 6.0/7.1kW Model shows a '40% Volume Decrease' for the 2018 model compared to conventional. 10.0-14.0kW Model shows 'Approx. 20% Volume Decrease' for the 2018 model compared to conventional. Dimensions and weight comparisons are provided.]
Splittable Ducted
Applicable models: 18.0kW / 20.0kW / 22.4kW. Designed to create comfort faster.
R410A Deluxe Model
Indoor Unit Models: 16.0kW (S-160PE1R5A), 18.0kW-22.4kW (S-180PE3R5, S-200PE3R5, S-224PE3R5).
Outdoor Unit Models: 16.0kW - 22.4kW (U-160PE2R8A*[3-Phase], U-180PE2R8A*[3-Phase], U-200PE2R8A*[3-Phase], U-224PE2R8A*[3-Phase]).
[R410A Refrigerant]
Premium Inverter Technology
Panasonic Premium Inverter Ducted air conditioners offer exceptional energy-saving performance and ensure comfort.
Reduces Electricity Consumption
Unlike conventional ACs that consume a lot of energy, Panasonic Premium Inverter Ducted models reduce wasteful operation for energy saving and better performance.
[Graphs: Two graphs comparing energy output and room temperature over time, showing conventional units with large fluctuations and Panasonic's inverter units with stable temperature control.]
Quick Comfort
Panasonic Premium Inverter Ducted air conditioners operate with higher power during start-up to cool and heat rooms faster than conventional units.
[Graphs: Two graphs comparing cooling and heating speeds, showing Panasonic Premium Inverter models achieving set temperatures faster than conventional models.]
Constant Comfort Air Conditioning
Panasonic Premium Inverter technology ensures precise temperature control and a wider power output range for extreme conditions in Australia, guaranteeing constant comfort.
Performance Range:
- R32 Compact Model: Offers comfort across LOW, MID, and HIGH room temperatures, with performance from 3.0 kW up to 11.5 kW, providing "Up to 15% Greater Performance".
- Brand X: Shown to have 'Over Cooling' and 'Under Cooling' issues in comparison.
[Visuals: Images depicting extreme environmental conditions: a hot desert landscape labeled '46°C OUTSIDE TEMPERATURE' and a snowy landscape labeled '-20°C OUTSIDE TEMPERATURE'.]
Control Solutions
Easy-to-use, with multiple energy saving functions at your fingertips.
Deluxe Wired Remote Controller
Features a large 3.5" full-dot LCD with white LED backlight. Characters and icons are clearly displayed for visibility, allowing temperature changes at night without turning on lights. It has a stylish, easy-to-use touch key design with a simple layout for intuitive operation.
[Image: Image of the Panasonic Deluxe Wired Remote Controller with its LCD display and touch keys.]
Smart Connectivity
The new form for control solutions, developed in collaboration with Schneider Electric. The SER8150 maintains high IAQ while saving energy. Its sleekly designed touch panel display is easy to use.
[Image: Image of a smart home interface displaying temperature and occupancy status.]
Plug & Play for Home Automation
Easily connect with integrated controllers to become part of your automated home network.
Supports integration with: Push™ by Schneider Electric and Clipsal® by Schneider Electric.
[Logos: Logos for Push and Clipsal, indicating integration with home automation systems.]
Reliable Comfort Comes from Reliable Technology
Discreet Comfort
Panasonic air conditioners are designed to be unobtrusive. Rigorous testing for noise levels, environmental performance, and ease of operation ensures they keep your home comfortable without intrusion.
[Image: An outdoor air conditioning unit positioned in an anechoic chamber, signifying noise level testing.]
Tested Durability
Units undergo simulated continuous operation under harsh conditions, including wind and rain tests, and detailed mechanism examination to ensure ruggedness and long-term dependability.
[Image: Air conditioning units being tested in a laboratory setting, likely simulating various environmental stresses.]
Shock Resistance
Units are tested for impacts, vibrations, drops, and stacking issues encountered during transportation and storage, ensuring readiness for installation.
[Image: An air conditioning unit being subjected to a drop test, demonstrating shock resistance.]
Class Leading Features
Energy Saving Technologies
Panasonic's Premium Inverter technology creates an energy-saving system that lowers cooling capacity and power consumption when needed. These technologies benefit the environment and reduce power bills without compromising comfort.
[Image: An image symbolizing energy saving and environmental benefit, showing coins with a plant growing from them.]
Designed for the Australian Environment
Premium Inverter ducted systems offer an outstanding operating temperature range. Cooling is possible up to 46°C, and heating operates down to -20°C, covering Australia's extreme conditions.
[Visuals: Images depicting extreme environmental conditions: a hot desert landscape labeled '46°C OUTSIDE TEMPERATURE' and a snowy landscape labeled '-20°C OUTSIDE TEMPERATURE'.]
Superior Technology
- Demand Response Enabling Device (DRED) ready
- Panasonic Premium Inverter technology
- DC fan motor
- Incredibly quiet operation
- Compact indoor and outdoor design
- Easy interfacing for remote On/Off, control outputs, and third party control.
Control, Comfort & Reassurance
Quiet Operation
Panasonic Premium Inverter ducted systems are among the quietest globally. Enjoy comfortable nights with quiet operation of both indoor and outdoor units, ensuring no disturbance to neighbours.
[Image: A person sleeping soundly in a comfortable bed, illustrating the quiet operation of the air conditioning.]
Cold Drafts Reduced During Winter
Addresses a common issue with ducted ACs. Panasonic Premium Inverter units use clever sensor technology to warm airflow before it enters the room during heating mode, preventing cold drafts and maintaining comfort.
[Image: A person comfortably enjoying a beverage indoors, implying a pleasant indoor climate.]
You Can Count on Panasonic
Panasonic air conditioners are built to high quality standards for reliable comfort. This reliability is backed by a full 5-year parts and labour warranty.
[Image: A prominent '5 YEAR FULL WARRANTY' badge, signifying product reliability and customer assurance.]
Specifications
R32 Compact Model Specifications
Capacity | Model Name | Indoor Unit | Outdoor Unit | Cooling Capacity (kW) | Heating Capacity (kW) | BTU/h | EER / COP (W/W) | Total Power Input (kW) | Phase/Hz | Power Source (V) | Current (A) | Dimensions (HxWxD mm) | Net Weight (kg) | Air Volume (L/s) | External Static Pressure (Pa) | Sound Pressure Level (dB(A)) | Sound Power Level (dB(A)) | Fan Speeds | Drain Pipe Size (mm) | Piping Connections (Liquid/Gas mm) | Pipe Length (m) | Elevation Difference (m) | Max. Chargeless Length (m) | Refrigerant | Operation Ranges (°C) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6.0kW | S-60PE1R5B | U-60PZ2R5 | 6.0 (2.0 - 7.1) | 6.0 (1.8 - 7.6) | 20,500 (6,800 - 24,200) | 3.23 / 3.92 | 1.86 / 1.53 | 1 Phase/50Hz | 230V / 240V | 0.85 / 0.85 | 290×1,100 (+100)×700 | 35 | 366 / 366 | 70 (10-100) | 43/41/40 | 60/58/57 | 3 | VP-25 | 09.52 / 015.88 | 3-40 | 15, 30 | 30 | R32, 1,450g, 35 (g/m) | -10 to 43 / -15 to 24 | |
7.1kW | S-71PE1R5B | U-71PZ2R5 | 7.1 (2.0 - 8.0) | 7.1 (1.8 - 8.6) | 24,200 (6,800 - 27,300) | 3.18 / 4.06 | 2.23 / 1.75 | 1 Phase/50Hz | 230V / 240V | 1.24 / 1.24 | 360×1,100 (+100)×700 | 42 | 500 / 500 | 100 (10-150) | 45/44/43 | 62/61/60 | 3 | VP-25 | 09.52 / 015.88 | 3-40 | 15, 30 | 30 | R32, 1,450g, 35 (g/m) | -10 to 43 / -15 to 24 | |
10.0kW | S-100PE1R5B | U-100PZ2R5 / U-100PZ2R8*[3-Phase] | 10.0 (3.0 - 11.5) | 10.0 (3.0 - 14.0) | 34,100 (10,200 - 39,200) | 3.33 / 3.89 | 3.00 / 2.57 | 1 Phase/50Hz | 230V / 240V | 1.72 / 1.72 | 360×1,100(+100)×700 | 44 | 666 / 666 | 100 (10-150) | 48/46/44 | 70/68/66 | 3 | VP-25 | 09.52 / 015.88 | 5-50 | 15, 30 | 30 | R32, 2,600g, 45 (g/m) | -10 to 43 / -15 to 24 | |
12.5kW | S-125PE1R5B | U-125PZ2R5 / U-125PZ2R8*[3-Phase] | 12.5 (3.2 - 13.5) | 12.5 (3.3 - 15.0) | 42,700 (10,900 - 46,100) | 3.30 / 4.00 | 3.79 / 3.125 | 1 Phase/50Hz | 230V / 240V | 1.82 / 1.82 | 430×1,100(+100)×700 | 48 | 833 / 833 | 100 (10-150) | 49/47/45 | 71/69/67 | 3 | VP-25 | 09.52 / 015.88 | 5-50 | 15, 30 | 30 | R32, 2,600g, 45 (g/m) | -10 to 43 / -15 to 24 | |
14.0kW | S-140PE1R5B | U-140PZ2R5 / U-140PZ2R8*[3-Phase] | 14.0 (3.3 - 15.0) | 14.0 (3.4 - 16.0) | 47,800 (11,300 - 51,200) | 3.15 / 3.66 | 4.44 / 3.825 | 1 Phase/50Hz | 230V / 240V | 2.62 / 2.62 | 430×1,100(+100)×700 | 53 | 1,000 / 1,000 | 100 (10-150) | 51/49/47 | 73/71/69 | 3 | VP-25 | 09.52 / 015.88 | 5-50 | 15, 30 | 30 | R32, 2,980g, 45 (g/m) | -10 to 43 / -15 to 24 |
R410A Deluxe Model Specifications
Capacity | Model Name | Indoor Unit | Outdoor Unit | Cooling Capacity (kW) | Heating Capacity (kW) | BTU/h | EER / COP (W/W) | Total Power Input (kW) | Phase/Hz | Power Source (V) | Current (A) | Dimensions (HxWxD mm) | Net Weight (kg) | Air Volume (L/s) | External Static Pressure (Pa) | Sound Pressure Level (dB(A)) | Sound Power Level (dB(A)) | Fan Speeds | Drain Pipe Size (mm) | Piping Connections (Liquid/Gas mm) | Pipe Length (m) | Elevation Difference (m) | Max. Chargeless Length (m) | Refrigerant | Operation Ranges (°C) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16.0kW | S-160PE1R5A | U-160PE2R8A*[3-Phase] | 16.0 (5.4 - 18.0) | 18.0 (5.6 - 20.0) | 54,600 (18,400 - 61,400) | 3.02 / 3.53 | 5.96 / 5.66 | 1 Phase/50Hz | 230V / 240V | 2.62 / 2.70 | 430×1,100(+100)×700 | 53 | 1,000 / 1,000 | 100 (10-150) | 51/49/47 | 73/71/69 | 3 | VP-25 | 09.52 / 019.05 | 5-50 | 15, 30 | 30 | R410A, 5,600g, 50 (g/m) | -15 to 46 / -20 to 24 | |
18.0kW | S-180PE3R5 | U-180PE2R8A*[3-Phase] | 18.0 (5.4 - 20.0) | 20.0 (5.6 - 22.4) | 61,400 (19,100 - 68,200) | 3.02 / 3.53 | 5.18 / 5.11 | 3 Phase/50Hz | 400V / 415V | 7.40 / 7.20 | 1,500 x 980 x 370 | 127 | 1,200 / 1,050 / 883 | 60 (Max 150) | 46/44/41 | 78/76/73 | 3 | VP-25 | 09.52 / 019.05 | 5-50 | 30, 30 | 30 | R410A, 5,600g, 50 (g/m) | -15 to 46 / -20 to 24 | |
20.0kW | S-200PE3R5 | U-200PE2R8A*[3-Phase] | 20.0 (6.3 - 22.4) | 22.4 (7.1 - 25.0) | 68,200 (21,500 - 76,400) | 3.12 / 3.61 | 6.41 / 6.20 | 1 Phase/50Hz | 230V / 240V | 3.30 / 3.30 | 486 x 1,456 x 916 | 86 | 1,200 / 1,050 / 883 | 75 (Max 180) | 46/44/41 | 78/76/73 | 3 | VP-25 | 09.52 / 019.05 | 5-50 | 30, 30 | 30 | R410A, 6,400g, 80 (g/m) | -15 to 46 / -20 to 24 | |
22.4kW | S-224PE3R5 | U-224PE2R8A*[3-Phase] | 22.4 (6.3 - 25.0) | 25.0 (7.1 - 28.0) | 76,400 (21,500 - 85,300) | 3.00 / 3.52 | 7.46 / 7.10 | 1 Phase/50Hz | 230V / 240V | 4.20 / 4.20 | 486 x 1,456 x 916 | 88 | 1,400 / 1,200 / 983 | 75 (Max 200) | 47/45/42 | 79/77/74 | 3 | VP-25 | 09.52 / 019.05 | 5-50 | 30, 30 | 30 | R410A, 6,400g, 80 (g/m) | -15 to 46 / -20 to 24 |
[Note: Tubing size may differ depending on pipe length. Please refer to technical documents.]