User Manual for ABB models including: STX3XX, 2BAJ6-STX3XX, 2BAJ6STX3XX, STX, STX Serial Wireless Temperature Sensor, Serial Wireless Temperature Sensor, Wireless Temperature Sensor, Temperature Sensor

Bran-Jing Liu

User Manual

ABB Electrical Equipment(Xiamen)Co.,Ltd. STX3XX 2BAJ6-STX3XX 2BAJ6STX3XX stx3xx

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6499972
ABB
User manual
ABB STX serial wireless temperature sensor

2
1. Overview

2NGA000585

ABB STX serial products are the key data source in ABB's monitoring and diagnostic solutions. This self-powered wireless smart sensor harvests the electromagnetic energy around power transmission conductor, continuously monitors the temperature of critical connections and wirelessly transmits to the concentrator. Eventually, the data will be stored in ABB Ability local or cloud-base solutions to enable a variety of different digital services.
 High performances
 Wide measurable range -40- 130  Excellent accuracy
<1.0°C @-10°C...85°C <2.0°C @-30°C...100°C <2.5@ outside the range  Support up to 3 measuring channels
 Self-powered
 Battery free  5A minimum active current
 Wireless
 IEEE802.15.4 at 2.4GHz  Private protocol  100m maximum transmission distance  Support OTA firmware update
 Stronger and durable
 Tiny size: 26x26x13mm, 18g weight  IP54 level  Easy installation

CNTC | ABB

3
2. Appearance and size

2NGA000585

26mm

Appearance of product

27mm

13mm

Dimensions

3. Ordering information

Type STX301 STX303

Mode Standalone External

STX311 STX313

Standalone External

CNTC | ABB

Protocol ABB Private ABB Private ZIGBEE Green Power ZIGBEE Green Power

4

4. Installation

4.1 Check the delivery of materials

Standalone mode
Part

Description STX301 thermal sensor

2NGA000585
Quantity 3

External mode
Part

Metal buckle

4

Description STX303 thermal sensor

Quantity 1

Metal buckle

2

External probe cable

1

CNTC | ABB

Notice!
The ferromagnetic ribbon shall be ordered separately, it's total length is 7.2 meters.

4.2 Check the tools

Tools

Type Metal scissor

5 2NGA000585
Usage Cut off and shape the ferromagnetic ribbon

Manual tensioner Bind the sensor

Long nose plier

Shape the tail of ferromagnetic ribbon

Gloves

Protect the hands

4.3 Start installation
4.3.1 Sensor boy
1 Use the scissor to cut off the ferromagnetic ribbon, the length should be 100-150mm longer than
the surface perimeter of measured conductor or cable.

100-150mm
CNTC | ABB

Busbar or cable

6
2 Cut two edges of ferromagnetic ribbon to an arc, to make it safer.

2NGA000585

Right angel

Not flat

Acute angel

Arc edge

3 Put the ribbon through the metal buckle from one end, then bend it's extremity with an angle at
90° longer than 10mm.

4 The ribbon goes through the sensor, ties it to the measured conductor or cable.

The position of sensor shall be in the middle of conductor, meanwhile the thermistor shall be at the closest position of the connection.

CNTC | ABB

7 2NGA000585
To improve insulation level, the metal buckle also shall be installed in the middle position of busbar.
5 The head of manual tensioner must hold against the buckle then tense the ferromagnetic ribbon,
make sure that the sensor is tied on measured conductor tightly. Finally, press the metal buckle.
6 Cut off the remaining of ribbon with metal scissor
7 Roll up the tail
CNTC | ABB

8
4.3.2 External probe (only for STX303 & STX313)
1 There are two methods to install the ring terminals, as below.

2NGA000585

Fixed by bolt

Bound by metal cable tie

2 Open the rubber cover and then insert the connector of cable into sensor body

CNTC | ABB

9
5. Cautions and notices

2NGA000585

Failure to follow these instructions can result in death or injury.
 Turn off all power supplying this product before working on  The operator must be qualified electrical personnel  Replace all devices, doors and covers before turning on the power  As the surface of the conductor or cable could be very hot, do not perform any
operations when the temperature of this part is above than 50
 As the metallic parts are very sharp and thin, please check your individual protection. Gloves must be required
 Follow the guide to use tools during the installation
FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
CNTC | ABB

10 2NGA000585
FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
CNTC | ABB

11
6. Technical datasheet

2NGA000585

Measurement characteristics and communication

Description
Measuring temperature range Accuracy within ambient air temperature for operation
Transmission cycle Power emission Maximum communication distance (in free field unobstructed) Number of channels
Operation frequency
Power supply

Value
-40...130 <1.0°C @-10°C...85°C <2.0°C @-30°C...100°C <2.5°C outside the range 12...60s +5 dBm 100m 16 (ZIGBEE Green Power) 60 (ABB Private protocol) 2403 MHz...2480 MHz

Description
Minimum active current Voltage limit of the active part Current limit of the active part Withstand voltage level (50hz,1 min) Rated frequency
Environmental conditions

Value
5A 40.5 kV 5000 A 2 kV(only for external probe) 50/60 Hz

Description
Ambient air temperature for operation Environment humidity Atmospheric pressure Operating altitude Transport and storage temperature range

Value
-40...105 20...95%, non-condensing 86...106 kPa
0...5000 m -40...70

CNTC | ABB

12
EMC compliance
Description
EMC directive Standard
Radio equipment conformance
Description
RE directive standard
Electromagnetic compatibility tests
Description
Electrostatic discharge
Radiated Emissions Radiated Immunity Electrical fast transient/burst immunity Resistance to conducted disturbances Power frequency magnetic field immunity
Pulse magnetic field immunity Damped oscillatory magnetic field immunity Damped oscillatory wave immunity

2NGA000585
Reference
2014/30/EU EN 301489-1 EN 301489-17
Reference
2014/53/EU EN 300328
Level
4 KV (Contact) 8 KV (Air) Class A (30MHz...1GHz) 3 V/m (80MHz...6GHz) 4 kV 5 kHz & 100 kHz 10 V (0.15...80 MHz) 300 A/m Pulse 30 A/m Continue 1000 A/m Pulls 100 A/m (0.1 & 1 MHz) 2.5 kV (CM-100 kHz&1 MHz) 1 kV (DM-100 kHz & 1 MHz)

CNTC | ABB

13

7. Revision history

Date
28-Mar-2023 07-Apr-2023

Revision
A.1 A.2

Changes
Draft First release

2NGA000585

CNTC | ABB


Microsoft Word 适用于 Microsoft 365