Instruction Manual for GREYSTONE models including: CS-425-HC Series, High Output AC Current Switch with Time Delay, CS-425-HC Series High Output AC Current Switch with Time Delay, CS-425-HC Series High Output AC Current Switch, High Output AC Current Switch, AC Current Switch, Current Switch, Switch
Index of /Install Notes
CS-425-HC-0 - alpscontrols.com
File Info : application/pdf, 2 Pages, 109.36KB
DocumentDocumentCurrent Switch CS-425-HC Series - Installation Instructions INTRODUCTION The High Current Switch / Dryer Fan Control is a solid-state current switches with N.O. triac outputs to control high current line-voltage AC loads. All models have a factory set trip level of approximately 1 Amp and require no field adjustment for easy installation. Internal circuits are powered by induction from the line being monitored The High Current Switch / Dryer Fan Control series can operate a dryer booster fan directly. These devices sense when a clothes dryer is drawing 1 Amp of current and then closes the output switch to activate the dryer vent booster fan. When the dryer cycle is complete and the current drops below the threshold, the output switch will open or remain closed for a pre-set delay time to allow heat to be removed from the vent before the switch is opened again. The device output can switch 120 Vac loads up to 2.5 Amps. All models are UL certified. *WARNING* · Electric Shock Hazard, Use Caution · Disconnect and lock out power before installation · Follow national and local electrical codes · Read and understand these instructions before installing · Installation only by qualified electrical personnel · Do not rely on this device to indicate line power · Only install this device on insulated conductors · Only install on 600 Vac maximum conductors · Do not use this device for life-safety applications · Do not install in hazardous or classified locations · Install this product in a suitable electrical enclosure · Failure to follow these instructions may result in serious injury or death. INSTALLATION Read all warnings before beginning. Ensure the selected device has the correct ratings for application. Figure 1 Select a convenient location, with-in or adjacent to the breaker panel. Alternatively the sensor can be installed inside the dryer electrical compartment. Refer to Figure 4 through 7 for typical installations. Mount the sensor with two screws through the base. The base has integrated mounting tabs to allow screw mount to a surface. If predrilling is required, the actual device may be used to mark holes. The mounting holes in the base will accommodate up to a #10 size screw (Not supplied). See Figure 1. Figure 2 Three Phase Wiring For 3-Phase systems, Disconnect and loop the neutral power wire, white, through the current sensor and reconnect. Connect the fan power supply, as shown 120 Vac max, to the top terminals of the current sensor. See Figure 2 For 220 Vac 3-wire single-phase systems, Determine which of the Hot wires is active for the dryer only. (this is necessary for stacked washer/dryer units). Verify that there is sufficient current to trip the current switch (minimum of 1 amp). If required the wire can be looped through twice to increase the current read by the switch. Connect the fan power supply, as shown 120 Vac max, to the top terminals of the current sensor. See Figure 3. Exhaust Fan Power Supply 120 Vac Max Power to Dryer Neutral/ White Dryer Junction Figure 4 Installation as a dryer junction box (3 phase) Figure 3 220 Vac Three Wire Single-Phase Wiring Power to Dryer Neutral / White Fan Exhaust Fan Power Supply 120 Vac Max Dryer junction box Current sensor 120 Vac Power to Dryer HOT Neutral IN-GE-CS425HCXXX-01 Copyright © Greystone Energy Systems, Inc. All Rights Reserved Phone: +1 506 853 3057 Web: www.greystoneenergy.com Page 1 Figure 5 Installation as a dryer junction box (3-wire single phase) Power to Dryer Hot Fan Figure 6 Figure 7 Dryer junction box Current sensor 120 Vac Installation at fuse/breaker panel (3-phase) 120 Vac Power to Dryer Neutral / White Fan Current sensor Dryer junction box Installation at fuse/breaker panel (3-wire single phase) 120 Vac Hot Power to Dryer Fan Current sensor Dryer junction box SPECIFICATIONS Maximum Input Current .........50 Amps Trip Set-point ..............................Approximately 1 Amp Switch Rating ..............................120 Vac @ 2.5 Amps maximum Switch Type..................................Solid-state triac Off-State Leakage......................<1 mA Response On Time ....................<200 mS Delayed Off Time .......................CS-425-HC-0---15 Second, +/- 2 seconds CS-425-HC-5---5 Minutes, +/- 2 Minutes CS-425-HC-10---10 Minutes, +/- 2 Minutes CS-425-HC-15---15 Minutes, +/- 2 Minutes Operating Conditions ..............0 to 40°C (32 to 104°), 0 to 95 %RH non-condensing Material .........................................ABS, UL94-V0, Inuslation class 600V Enclosure Size .............................49mm H x 87mm W x 25mm D (1.95" x 3.45" x 1.00") AC Conductor Hole ...................20mm (0.8") diameter Mounting Holes .........................(2) 5mm holes spaced 76mm apart on base, (2) x 0.19" holes spaced 3" apart on base Agency Approvals .....................cULus listed Country of Origin.......................Canada DIMENSIONS 49mm 1.95" 25mm 1.0" 20mm 0.8" 87mm 3.45" IN-GE-CS425HCXXX-01 67.2mm 3.0" Copyright © Greystone Energy Systems, Inc. All Rights Reserved Phone: +1 506 853 3057 Web: www.greystoneenergy.com Ø5mm Ø0.18" Page 2 PRINTED IN CANADA