User Manual for Danfoss models including: NovoCon M Digital Actuator, NovoCon M, Digital Actuator, Actuator
File Info : application/pdf, 4 Pages, 2.04MB
DocumentDocumentOperating Guide NovoCon® M NovoCon® M / 73697030 A B © Danfoss | 2024.03 NovoCon® M + AB-QM NovoCon (DN 40/50) NovoCon® M + AB-QM NovoCon (DN 50) NovoCon® M + AB-QM NovoCon (DN 65-100) DN 40 - 100 NO presetting! 100 % Click 1b 1a Click AQ291838446552en-010504 | 1 NovoCon® M +24V 24V AC/DC 0V A+ BACnet MS/TP or B- Modbus RTU GND T3 Temperature sensor 3 R on R off T2 T1 GND GND AO AI Temperature sensor 1 Analog output Temperature sensor 2 Analog input GND is common for all signals Optional step (connecting flow sensor) NovoCon M +24V 0V A+ B- GND T3 R on R off T2 T1 GND GND AO AI Sharky FS 473 flow sensor Wire Description Blue Ground (-) White Volume pulse output (+) NovoCon®M 003Z8540 Actuator for AB-QM DN40-100 Control signal: BACnet MS/TP, Modbus RTU, 0-10V, 0-20mA Power: 24VAC/DC, 50/60 HZ Force: 550N. Stroke: 20 mm. Speed: 3-24s/mm Consumption: 3.5VA running. Standby 0.9W III IP54/40, -10T55 E100 VX01X 281624 0030471 6430 Nordborg, Denmark MADE IN SLOVENIA E100 VX01X 281624 0030471 Serial number and QR code can be removed from the NovoCon® M label and added to installation drawing. E100 VX01X 281624 0030471 Device Object Instance Number 2 | © Danfoss | 2024.03 AQ291838446552en-010504 NovoCon® M DIP Switch 12345678 R ON OFF Dip switches for addressing and bus protocol selection are located under the lid of the actuator. Dip switches 1 to 7 are used to assign the MAC address manually. Default MAC address assignment method is Auto MAC addressing for BACnet MS/TP and DIP Switches for Modbus RTU. Dip switch 8 is used to select between BACnet MS/TP (OFF=Default) and Modbus RTU (ON). When the protocol is changed on DIP Switch 8, a power cycle is required. For termination of the last unit on the field bus, turn the DIP Switch R located between the connectors to ON. Initial configuration Application mode: MSV:9 / 32810 Digital control (default), Analog control Select Valve Type MSV:3 / 32802 (default AB-QM NovoCon DN40) Select application MSV:10 / 32811 Heating (default) Cooling Design Flow Rate AV:30 / 32796 Heating AV:31 / 32798 Cooling Activate calibration MSV:0 / 33284 state 2 or use manual calibration NovoCon® M AQ291838446552en-010504 © Danfoss | 2024.03 | 3 NovoCon® M Click ~ 60° Safety Note To avoid injury and damage to persons and devices, it is absolutely necessary these instructions are carefully read and observed prior to assembly and commissioning. Necessary assembly, start-up, and maintenance work must be performed only by qualified, trained and authorised personnel. Switch off the power line before wiring the actuator. Safety Note If the NovoCon® M network is supplied with two or more AC power boosters, caution must be observed when disconnecting one of the transformers from the high voltage power line. As the NovoCons are connected in a daisy chain, there may be high voltage on the primary side of the disconnected power supply. Disconnect always both the primary and secondary side of the transformer. Firmware update We recommend to validate the firmware version before installation. The latest firmware can be downloaded at www.novocon.com by selecting the tab: Support files. : UA: « », . , 15/15/6, . , 04080, 4 | © Danfoss | DCS-SGDPT/SI | 2024.03 73697030 / AQ291838446552en-010504