Owner's Manual for cossiga models including: STGRF6, STGRF6 Tower Counter Refrigerated, Tower Counter Refrigerated, Counter Refrigerated, Refrigerated
File Info : application/pdf, 13 Pages, 2.82MB
DocumentDocumentTOWER COUNTER SERIES REFRIGERATED RF STGRF6 STGRF6-SD STGRF9 STGRF6-SD STGRF12 STGRF12-SD STGRF15 STGRF15-SD Heated double glazed glass top, sides and front Heated rear sub frame Argon filled rear doors Sliding rear doors Solid front or sliding front doors Deck forced refrigeration Two adjustable shelves - flat or angled Ticket strips on shelves and base Under shelf and canopy LED lights Integral condenser Solid glass front - optional STGRF6 hinged rear door CABINET DIMENSIONS & SPECIFICATIONS MODEL STGRF6 STGRF6-SD STGRF9 STGRF9-SD STGRF12 STGRF12-SD STGRF15 STGRF15-SD CABINET SHELVING SHELVING LENGTH DEPTH HEIGHT [MM] [MM] [MM] 600 650 925 WEIGHT KG 143 2 + BASE 900 650 925 178 2 + BASE 1200 650 925 212 2 + BASE 1500 650 925 243 2 + BASE OPERATING TEMP DEG C 3-5 3-5 3-5 3-5 SHELF W X D BASE TRAY W X D TOTAL FOOD DISMPL2AY 100MM UNITS INTERNAL VOLUME M3 FREQUENCY REFRIGERANT POWER KW AMP 230V CONNECTION ELECTRICAL POWER CORD 2200MM NZ/AUS 10 AMP UK 13 AMP 490 X 445 540 x 415 86 0.61 0.29 50/60 HZ R290 1.01 4.3 3 PIN PLUG 3 PIN PLUG 790 X 445 840 x 415 136 0.96 0.45 50/60 HZ R290 1.06 4.6 3 PIN PLUG 3 PIN PLUG 1090 X 445 1140 x 415 175 1.32 0.60 50/60 HZ R290 1.15 5.0 3 PIN PLUG 3 PIN PLUG 1390 X 445 1440 x 415 285 1.67 0.75 50/60 HZ R290 1.24 5.4 3 PIN PLUG 3 PIN PLUG VOLTAGE PACKED FOR SHIPPING 220240V 220240V 220240V 220240V LENGTH DEPTH HEIGHT WEIGHT [MM] [MM] [MM] 700 730 1450 150 1000 730 1450 185 1300 730 1450 219 1600 730 1450 300 Maximum shelf load weight 15kg spread evenly SLIDING FRONT DOORS and rear glass sliding doors STGRF-SD SOLID FRONT and rear glass sliding doors STGRF Page 1 Date Modified: 24/04/23 Check website for latest version Download C.A.D models or contact us on COSSIGA.COM TOWER PLACED IN BENCH DETAIL ALLOW 400 mm ALLOW 400 mm min 75 mm CutRoFu6tC5u2t5omutm525 mm min 20 mm Cut out 620 mm Remove feet for all drop-in installations Supplied 5mm PVC wedge strip to sides for drop-in unit. 150 mm min 20 mm Open at rear. Cut out see table benchtop cut out sizes Condensor unit 545w x 485d x 390h (RF6 485w x 485d x 335h) min 75 mm Open at rear. Condensor unit 545w x 485d x 390h (RF6 485w x 485d x 335h) RCFu6tCouutt o5u8t55m25mmm Full bench top drop in Page 2 Date Modified: 24/04/23 Check website for latest version Supplied 5mm PVC wedge strip to sides for drop-in unit. No glue or sealant required On bench top drop in Download C.A.D models or contact us on COSSIGA.COM TOWER AIR FLOW CONSIDERATIONS REAR VIEW Hole Cut to meet condenser face 350 mm varies 260 mm REAR VIEW An extract fan may be required if hot air is not adequately venting varies 200mm clear space Joinery divider panel providing sealed air intake plenum with cutout to meet condenser face UNITS SHOWEN FROM REAR VIEW Ideal configuration cabinet open at rear Page 3 Date Modified: 24/04/23 Check website for latest version Joinery divider panel providing sealed air intake plenum with cutout to meet condenser face Intake and extract vents. Guaze or similar material allowing good airflow Cabinet with vented rear doors Download C.A.D models or contact us on COSSIGA.COM TOWER JOINERY TO REAR WALL WITH VENT Horizontal vent in cabinet top for hot air extract Electric biscuit fans can also be fitted to provide mechanical extract Ambient air ducted in to compressor face through air plenum space Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face Allow access for cleaning, servicing and waste evaporator water removal Page 4 Date Modified: 24/04/23 Check website for latest version Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit Vent must be at least 100mm deep and as wide as unit Download C.A.D models or contact us on COSSIGA.COM TOWER EXTRACTION FAN - VENTILATION GRILL EXTRACTION FAN Extract hot air from box joinery Fan and power cable supplied, screw fixed to joinery Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case Cossiga part number X000611 Extraction Fan Page 5 Date Modified: 24/04/23 Check website for latest version VENTILATION GRILL Stainless steel construction Hole cut out size 540 mm x 298 mm Square grille holes 10mm x 10mm Cossiga part number X000765 Ventilation Grill Screws not included Download C.A.D models or contact us on COSSIGA.COM TOWER REFRIGERATED SERVICES INFORMATION DRAINAGE RECOMMENDATIONS for high humidity locations condensate drain to four litre container 3/8" pipe max run 1500 mm Vertical pipe runs are not recommended Pipe runs over 150mm : Expansion valve will need to be fitted Correctly sized condensing unit fitted Correct pipe size determined REMOTE COMPRESSOR INSTALLATION Page 6 Date Modified: 24/04/23 Check website for latest version Plumbed Receptacle As standard units are self evaporating to a receptacle in the condenser unit. In areas of high humidity it is recommended by-passing the evaporator dish. A plastic hose can be attached to the end of the condensate drain and re-directed as shown. PLUMBED TUNDISH DRAINAGE - Maximum 150 mm above finished floor level - Drainage to building waste - Building waste by client FREE STANDING RECIPIENT - Receptacle placed under unit to receive condensate waste - Dispose of waste water daily TO BE CONSIDERED FOR HIGH HUMIDITY SITES WITH ACCESS TO DRAINAGE Download C.A.D models or contact us on COSSIGA.COM TOWER IN BENCH INSTALLATION THESE UNITS ARE HEAVY AND REQUIRE LIFTING INTO BENCH TOPS PROTECT BENCHTOP LIFT TO BENCH AND REST REMOVE To reduce weight remove - All doors - Shelving - Base plates PLAN AHEAD - Have plenty of labour on hand - Use a mechanical lifting device - optional - Check bench top hole measurement - Ensure enough clear depth in cabinet work - Protect bench top with a mat or similar - Pre-adjust unit feet if needed All accepted local safety work wear and standards should be adhered to with a safety programme developed before undertaking of this kind of lifting work Page 7 Date Modified: 24/04/23 Check website for latest version Download C.A.D models or contact us on COSSIGA.COM TOWER UNIT PLACEMENT GUIDE CLEAR FLOW NO AIR FLOW AIR FLOW BLOCKED Too much chilled air around coil can create excessive ice build up CORRECT AIRFLOW IN CORRECT AIRFLOW Blocked air flow will retard operation on both HOT and COLD units Ensure trays or plates are not blocking air flow at rear Locations to avCooildd air disrupted Close to shop front exterior In an outside location In direct sunlight In a high wind Near any source producing excessive heat Service units more frequently in dusty or polluted areas Environmental conditions Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor Page 8 Date Modified: 24/04/23 Check website for latest version Download C.A.D models or contact us on COSSIGA.COM TOWER ACCESSORIES Top Mounted Controller Panel For against wall installations Sold individually Ventilation Grill Stainless Steel Sold individually 450 mm Humidity Dish Stainless Steel Perforated lid is removable 450 mm Page 9 Date Modified: 24/04/23 Check website for latest version Base Tray - Heated Units Stainless Steel For heated units Sold in pairs Tong Holder Stainless Steel Drop into counter tray race Sold individually 100 mm 190 mm 80 mm Bag Holder Stainless Steel Drop into counter tray race Solid individually 220 mm 105 mm 75 mm 190 mm Download C.A.D models or contact us on COSSIGA.COM TOWER TICKET STRIP Shelf with ticket strip attached Lengths CABINET LENGTH MM 600 900 1200 1500 TICKET STRIP LENGTH 475 775 1075 1375 Page 10 Date Modified: 24/04/23 Check website for latest version Ticket Strip Stainless Steel Attaches to shelf frame End Profile Price Tabs Stainless Steel Write on with marker or adhesive tape Measure 60mm x 30mm Sold in packs of 20 Download C.A.D models or contact us on COSSIGA.COM TOWER GLASS SHELVING Glass Shelf Options Standard wire racks are removed and replaced with 6mm toughened glass panes Maximum shelf load weight 15kg spread evenly MODEL GLASS STGRF6 6MM TOUGHENED - POLISHED EDGES STGRF9 6MM TOUGHENED - POLISHED EDGES STGRF12 6MM TOUGHENED - POLISHED EDGES STGRF15 6MM TOUGHENED - POLISHED EDGES STGAB6 6MM TOUGHENED - POLISHED EDGES STGAB9 6MM TOUGHENED - POLISHED EDGES STGAB12 6MM TOUGHENED - POLISHED EDGES WIDTH MM 240 DEPTH MM 385 390 385 540 385 690 385 240 385 390 385 540 385 PER SHELF SHELVES PANES 2 2 2 2 2 2 2 2 2 3 2 3 2 3 TOTAL PANES 4 4 4 4 6 6 6 Page 11 Date Modified: 24/04/23 Check website for latest version Support bracket Download C.A.D models or contact us on COSSIGA.COM TOWER HEATED UNITS ACCESSORIES Mirror film Applied to the inside glass rear doors Suitable for heated and chilled units Pie Trays Stainless Steel Construction Placed on shelves for heated food items ADDS DEPTH TO YOUR DISPLAYS Mirror film adhered to inside of rear door glass BLOCKS WORK AREAS BEHIND UNITS MODEL CODE PIE TRAYS QUANTITY STGHT6 AA16015 STGHT9 AA16016 STGHT12 AA16017 4 Per Shelf 6 Per Shelf 9 Per Shelf PIE TRAYS 1ST SHELF 2ND SHELF 3RD SHELF TOTAL DEPTH DEPTH DEPTH 400MM 365MM 400MM 12 Trays TRAY WIDTH 120MM 400MM 400MM 400MM 18 Trays 130MM 400MM 400MM 400MM 27 Trays 120MM Page 12 Date Modified: 24/04/23 Check website for latest version Download C.A.D models or contact us on COSSIGA.COM TOWER COLOUR WRAP OPTIONS COUNTER TOP MODEL - all exterior visible areas covered all exterior top visible areas covered 2mm gap left around rear frame Rear of units cut around serial number plate, exhaust fan and controller Page 13 Date Modified: 24/04/23 Check website for latest version Download C.A.D models or contact us on COSSIGA.COM