User Manual for ANCEL models including: HD3X0002, 2ASC7HD3X0002, HD Series Commercial Vehicle Diagnostic Tools, HD Series, Commercial Vehicle Diagnostic Tools, Vehicle Diagnostic Tools, Diagnostic Tools, Tools
OBDSPACE TECHNOLOGY CO,.LTD HD3X0002 Truck Scanner 2ASC7HD3X0002 2ASC7HD3X0002 hd3x0002
File Info : application/pdf, 25 Pages, 1.52MB
DocumentDocumentHD series 1. PRODUCT OVERVIEW Ancel HD series products are commercial vehicle diagnostic tools based on special Android tablet. This product integrates commercial vehicle OBD standard diagnostic protocols, including SAE J1939, SAE J1708, SAE J1850 PWM, SAE J1850 VPW, ISO 14230-4, ISO 9141-2, ISO 15765-4 and ISO 27145-4. The commercial vehicles are classified according to the vehicle type information, and the operation interface is very clear, which makes it convenient for users to diagnose commercial vehicles. There's a optional printer module available to have diagnosis data and report printed. At the same time, the product supports online upgrade of diagnostic program and diagnostic data. 1 2. PRODUCT STRUCTURE HD series 2 HD series Serial No. Name Function Description Connection interface connects vehicle Main Testing 1 Cable communication cable during vehicle diagnosis Used to connect to an external 2 USB Port computer 3 Print Used to print diagnostic reports and results Paper bin After opening, you can install and 4 cover replace the printing paper Touch Display content and touch operation 5 screen area 6 Speaker Device sound output Auxiliary 7 Auxiliary for hand holding bandage Separation 8 switch Host and printer separation switch 9 Test key Printer self test and paper feed button 10 Paper outlet Printer paper outlet 3. HOST CONFIGURATION CPU Quad-Core ARM Cortex-A7 RAM 1GB Flash 8GB Display 5 inches LCDresolution ratio 800*480 TP touch screen Capacitive screen 3 WIFI Horn USB interface Diagnose interface Operating voltage Operating temperature Storage temperature 802.11b/g/n 2.4GHz Support Type C interface DB15 interface DC 10V~24V/3A -20~60 -30~70 HD series 4. PRINTER CONFIGURATION (OPTIONAL) Printer 80mm thermal printer Print speed 60mm/s Effective print width 72mm Print resolution 203dpi 1mm=8dots Print paper specifications 80mm*30mm 5. POWER ON/OFF 1) Power on The device can be powered on in the following ways: Vehicle power on: plug one end of the main diagnostic test line into the DB-15 interface of the device, and the other end into the diagnostic interface of the vehicle, and the device will automatically start up . If it doesn't started up, it may be that there is no power supply for the vehicle diagnostic seat, and the device can be powered by the cigarette lighter or battery clamp. 4 HD series Power on the power adapter: plug one end of the main diagnostic test line into the DB-15 interface of the device, connect the power adapter, and the device will start automatically. Note: the voltage of the power supply should be within the scope of application of the product equipment. If it is beyond the scope, the product may be damaged. 2) Power off Before power off, please stop all diagnostic items and return back to the main interface. Pull out the diagnostic main test line from the diagnostic interface of the vehicle. If the device is not equipped with battery, the device will shut down automatically after disconnecting the main test line from the diagnostic interface of the vehicle. 6.VEHICLE DIAGNOSTIC PREPARATION The diagnostic program establishes data connection through the vehicle electronic control system connected with the equipment, which can read the vehicle diagnostic information, view the data flow, and perform action test and other functions. For details of the functions, please refer to the model which you purchased. To establish good communication between the diagnostic program and the vehicle, the following operations need to be performed: 1) Turn off the ignition; 2) Find the diagnostic interface of the vehicle: it is usually located on the driver side; If the diagnostic interface is not found, 5 HD series please refer to the vehicle maintenance manual. 3) Insert one end of the diagnostic main test line into the device DB-15 connector and tighten the retaining screws. The other end is connected to the vehicle's diagnostic interface. Note: Before the equipment is connected to the vehicle, it is necessary to judge whether the diagnostic seat of the vehicle is a standard OBD-II interface or a non-standard OBD-II interface. The vehicle compatible with OBD-II management system only needs to use the integrated main test line OBD connector to connect with the vehicle diagnosis seat and provide power; For vehicles that are not compatible with the OBD-II management system, the corresponding connector should be selected; Some vehicles need to be powered by other vehicle power sources. The following is an operation description of these two connection modes. 1) Connection of standard OBD-II interface The vehicle connected with standard OBD-II interface only needs to use the integrated main test line OBD connector, and no other connectors are needed, as shown in the figure: 6 HD series 2) Connection of non OBD-II interface Vehicles with non OBD-II interface need to connect the main test line with the corresponding special connector, as shown in the figure: 7 HD series Note: at this time, the equipment is powered by the vehicle diagnosis seat, and the equipment starts automatically. If not, it may be that the vehicle diagnosis seat has no power supply, and the equipment can be powered by the cigarette lighter or battery clip. 7.INTRODUCTION OF EACH FUNCTION MENU After the system is started, the main menu of function will be entered. The main menu of each version of model will be slightly different. Please refer to the display of the model you purchased. 1) Toolbar (see Table 1) 2) Function main menu (see Table 2) Icon Table 1: Toolbar Function name Function description Refresh Refresh upgrade menu Home Return to the main interface of the system Screenshot Capture current screen picture Test report Used to save test data during diagnosis (can be viewed in data management menu) 8 HD series Icon Function name Function description Feedback Print Used to report the problem to the company's service system (need to connect to the network) when the system cannot be accessed during the diagnosis process Used to print test results or test reports. The printer is optional Used to edit files, lock, unlock or delete Edit files Added Used to add feedback information WIFI WIFI connection network Brightness Used to adjust the brightness of the device screen Volume Used to adjust the volume of the device User info Used to view device status and user information Data cleaning Used to remove useless data from the device General Used to set device language, unit and time, view device information and restore 9 factory settings HD series Icon Table 2: Function main menu Function name Function description Diagnostic procedure: Diesel OBD, Diesel OBD see section 5 for details OBD-II Diagnostic procedure: OBD-II, see section 5 for details Model diagnosis The diagnosis menu of each model will be slightly different. Please refer to the model you purchased Service DPF regeneration and maintenance lamp zero and other services. Please refer to the model you purchased Tools (Pin Detect)For the measurement of pin voltage of diagnostic interface, see section 6 for details Data For browsing and managing saved management data files, see section 7 for details Upgrade For online upgrade of system software and vehicle software, see section 8 for details Settings Set and view system information, see section 9 for details 10 HD series 8. DIAGNOSTIC FUNCTION 1) TakeHD3200Diesel OBDas an example; ClickDIESEL OBDmenu enter the diagnosis interface. 2) Select connector according to the specific situation, such as Diesel6&9PIN; 3) Select the required diagnostic method,such as Standard protocol(Fast Scan); 11 HD series 4) Click Start test 5) Select(J1939) Engine; 12 HD series 6) EnterDiagnosis home page; The main diagnostic interface usually includes the following options: ECU Information: Read and display the control system module information detected from ECU Read Fault Code: Read the fault code information retrieved from the vehicle system module Erase Fault Code:Clear the fault code and freeze frame data 13 HD series retrieved from the vehicle system module Live Data: Read and display the real-time operation parameters of the current system module 9. PIN DETECT This function mainly measures the voltage of 16 PIN of OBD diagnostic interface, and judges the pin position of K- line and CAN line. After connecting the OBD interface of vehicle, click the main interface Tools to select pin detection. The program automatically measures the 16pin voltage of OBD diagnosis interface, and judges the pin position of K-line and can line, as shown in the figure below: 10. DATA MANAGEMENT Data ManagementThe function is used to save and view test reports, screenshots and problem feedback files. Most of the files are generated by executing the toolbar operation of the vehicle diagnosis interface. 14 HD series 11. DIAGNOSTIC SOFTWARE UPGRADE By connecting the device to the wireless network, the diagnostic software can be upgraded and the product function can be improved in time. Open Update in the function main menu, and the system will automatically search for the latest update program, as shown in the figure below. Click Update to upgrade the model and other applications to the latest version. 15 HD series 12. SETTINGS Select Settings from the main menu to open the setting interface, where you can adjust the following system settings 12.1 WIFI CONNECTION The device supports wireless network connection for diagnosis software upgrade and problem feedback. 12.2 BRIGHTNESS The device supports screen brightness setting, please adjust it according to your adaptive brightness. 16 HD series 12.3 ACTIVATE 1) Activate The products are not activated when they leave the factory. Connect the network to enter the setting, and click Activate to activate the machine. 2) User Info Set your personal information: name, telephone, email, address, 17 HD series etc. 12.4 DATA CLEANING Cleaning up useless data with one click, freeing up more space and cleaning up regularly will help the system run more stably. 12.5 General 1) Language Please select settings based on the language you support for 18 the model you purchased. HD series 2) Unit This option can set the data flow unit in the diagnostic equipment software. Please select metric system or English system as required. 3) Date&Time This option can set the date / time of the device. The default is automatic network synchronization update, or it can be set manually. 19 HD series 4) Reset This option can restore the original settings of the device, which will delete all the data stored in the device, including the activation information and model data. You need to re-connect the network to activate and download the model data package. 13. PRINTER INTRODUCTION 1) Printer combination and split 20 HD series 1. Hold the printer in your hand, aim at the lead-in slot on the back of the main unit, push it in slightly, and you will hear a "click" voice, which means the main unit and the printer has already connected together. 2. After pressing the separation switch, hold the printer in your hand and gently pull it out. The printer will be separated from the host. 2) Printer loading and changing paper 21 HD series 1. Hold the position of the printer paper bin cover with your fingers and open the cover up; 2. Put the printing paper into the paper bin according to the diagram. Pay attention to the direction of the paper. If the installation is reversed, the printing will be blank; 3. Just close the paper bin cover. 3) Printer self test function 22 HD series 1. When the machine is turned on, press the printer test key briefly, and the printer will automatically print out a piece of blank paper. 2. In the case of power on, long press the printer test key for three seconds, the printer will automatically print a section of self-test content, indicating that the printer function is normal. 23 HD series 24 Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restrictionPDFium PDFium