Installation Guide for Altronix models including: T2KK38 8 Door Kit with Fused Outputs, T2KK38, 8 Door Kit with Fused Outputs, Fused Outputs, Outputs

IITroveK ULXB Kits L21U

Click to View

Altronix T2KK38 | 8-Door Access and Power Integration Kit

T2KK38-Installation-Instructions

Altronix T2KK38 8-Door Altronix/DMP Access and Power Integration Kit, Trove2DM2 with AL600ULXB, ACM8, T16100 | 123 Security Products

T2KK38D-Installation-Instructions

Altronix T2KK38D 8-Door Altronix/Keyscan Access and Power Integration Kit | 123 Security Products


File Info : application/pdf, 4 Pages, 688.85KB

PDF preview unavailable. Download the PDF instead.

T2KK38D-Installation-Instructions
Access & Power Integration
Altronix/Keyscan Kits
Models Include:

T2KK38
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKA2 Altronix/Keyscan backplane - (1) AL600ULXB - Power Supply/Charger - (1) ACM8 - Fused Access Power Controller - (1) T16100 Transformer
T2KK38D
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKA2 Altronix/Keyscan backplane - (1) AL600ULXB - Power Supply/Charger - (1) ACM8CB - PTC Access Power Controller - (1) T16100 Transformer
All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. TKKL_122121 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Altronix Trove Keyscan kits are pre-assembled and consist of Trove2KA2 enclosure/backplane with factory installed Altronix power supply/ charger, transformer, and sub-assemblies. These kits also accommodate various combinations of Keyscan boards for up to eight (8) doors in a single enclosure.

Configuration Chart:

Altronix Model Number
T2KK38

115VAC 60Hz Input Current (A)
3.5

Power Supply Board Input Fuse Rating
5A/ 250V

Power Nominal Maximum Supply Current Fail-Safe/

ACM8/

Supply DC

for Main and Aux. Fail-Secure Fail-Safe/ Current Current ACM8CB ACM8 ACM8CB

Board Output Outputs on Power

or Fail-Secure Per Per Board Board Board

Battery Voltage Supply board and ACM8/ Dry Outputs ACM8 ACM8CB Input Output Output

Fuse Range ACM8CB Access Power Form "C" (auto- Output Output Fuse Fuse PTC

Rating (V) Controller's outputs (A) Outputs resettable) (A)

(A) Rating Rating Rating

N/A

20.1926.4

24VDC @ 5.8A

8

­

2.5

­

10A/ 250V

2.5A

­

T2KK38D 4.2

5A/ 15A/ 20.17250V 32V 26.4

24VDC @ 5.8A

­

8

­

2.0

10A/ 250V

­

2A

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having jurisdiction.

Product is intended for indoor use only.

1. Remove backplane from enclosure. Do not discard hardware.

2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws

in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws, level and secure.

Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners.

Place the enclosure's upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.

Fig. 1

3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location,

opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2).

Enclosure

Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed

Edge of

reporting device. To activate alarm signal open the door of the enclosure.

Enclosure

4. Mount Keyscan boards to backplane, refer to page 3.

5. Refer to the ULXB Power Supply/Charger Installation Guide for AL600ULXB, Sub-Assembly Installation Guide for ACM8(CB), and T16100 Installation Instructions for

Tamper Switch (included)

T16100 for further installation instructions.

To Access Control Panel or

Hardware:

UL Listed Reporting Device

Nylon Spacer |

Metal Spacer |

Pan Head Screw | Lock Nut

- 2 -

Trove Keyscan ULXB Kits Installation Guide

T2KK38(D): Configuration of Keyscan Boards 1. Mount appropriate Keyscan boards into the correct positions (Fig. 2, pg. 2) by postioning spacers over appropriate holes in the
backplane and depressing down on board to secure spacer to the backplane (Fig. 2b, pg. 2). 2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided).

Fig. 2

ON OFF - 24V ON - 12V

Altronix - AL600ULXB

LG N

AC DC BAT BAT FAIL NC C NO NC C NO AC FAIL

+BAT-

+ DC -

TRIGGER INPUT

IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND

1

2

3

4

5

6

7

8

Altronix

ACM8 (T2KK38)

or

ACM8CB (T2KK38D)

INTERFACE

NO C NC +INP- T + RET-

FACP TRG

ON

ON

1234 1234

FACP

MAIN 10A 250V

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4

OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

Plastic Spacer pre-mounted into Keyscan modules
Insert into TKA2 or TKA3 backplane

Fig. 2b

-+-+ Power Control

Altronix T16100
Keyscan DPS15 Locknut

Keyscan CA250B, CA4500B CA8500B

Keyscan OCB8
Keyscan OCB8

Keyscan CIM

Trove Keyscan ULXB Kits Installation Guide

- 3 -

2.00" (50.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

Enclosure Dimensions (H x W x D approximate):
27.25" x 21.5" x 6.5" (692.2mm x 552.5mm x 165.1mm)
21.50" (546.1mm)
5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty