Genie SmartLink Software Installation Instructions
Part No. 216767 Rev B September 2014
Introduction
Observe and Obey:
- This procedure shall be completed by a person trained and qualified on the repair of this machine.
- Immediately tag and remove from service a damaged or malfunctioning machine.
- Repair any machine damage or malfunction before operating the machine.
Before Starting Installation:
- Read, understand and obey the safety rules and operating instructions in the appropriate operator's manual.
- Be sure that all necessary tools and parts are available and ready for use.
- Read this procedure completely and adhere to the instructions. Attempting shortcuts may produce hazardous conditions.
Indicates that a specific result is expected after performing a series of steps.
Indicates than an incorrect result has occurred after performing a series of steps.
Note: These installation instructions only apply to the Genie models listed on the front cover.
Tools Required:
- Torx T10 screw driver
- Cat5 Ethernet Cable
- PC or Laptop with an Ethernet Port and Internet Browser
Glossary of Terms
- ECM - Electronic Control Module
- GCON - Ground Controller. This ECM is located at the ground controls.
- PCON - Platform Controller. This ECM is located at the platform controls.
- CAT5 Cable - Standard Ethernet cable used for networking purposes.
If you have any further questions regarding these instructions or need assistance, please contact Genie Product Support at one of the following telephone numbers:
- United States: 800-536-1800
- Canada: 425-881-1800
- Europe: UK 0044 1476 584 333
- France 0033 237 260 986
- Germany 0049 4221 491 821
- Iberica 0034 935 725 090
- Italy 0039 075 941 8132
- Scandinavia 0046 3157 5154
- Other locations 0031 653 221 908
- Middle East: 0097 143 391 800 or 0097 150 459 7937
- Australia: 61 7 3456 4444
- All other locations 001-425-881-1800
Procedure
Software Version
Note: Before proceeding verify the version of software installed on your machine. The software revision is displayed at the GCON LCD.
- Turn the key switch to the ground controls or platform controls position. Pull out the red Emergency Stop button to the on position at both ground and platform controls.
- Result: The PCON LCD will show "CH".
- Result: The GCON LCD will show the machine model and hour meter information. After 3 seconds, the machine model will not show on the display.
- Press the ground control scroll down button.
- Result: The GCON LCD will show the software revision and hour meter information. After 5 seconds, the ground controls LCD will return to machine model and hour meter information.
- Push in the red Emergency Stop button to the off position at both the ground and platform controls and turn the key switch to the off position.
Procedure
Loading or Updating Machine Software
Note: Before updating the machine software, open a web browser and navigate to the following location for the Genie Machine Software Download portal, http://firmware.genielift.com. Perform a search by applying the appropriate filters and download the machine software.
Note: There are two procedures available to update the machine software. These are Bootloader Mode and Machine Application Mode.
Bootloader Mode
The Bootloader mode is only available with the key switch in the GCON position. It allows the user to update or reinstall the machine software by directing the system into the Bootloader.
Choose this mode if the GCON ECM is not operating correctly.
Machine Application Mode
The machine Application mode is available with the key switch in the GCON or PCON position. This mode of machine software update requires the user to enter the Machine Service Tool.
Choose this mode if the machine is operating correctly and you are updating the machine software.
Bootloader Mode Steps:
- Open the GCON compartment. Note: Some models will require opening the ground control box to access the GCON.
- Turn the key switch to the ground controls position and pull out the red Emergency Stop button to the on position at the platform controls.
- At the ground controls, press and hold the Enter and Escape buttons.
- Pull out the red Emergency Stop button to the on position at the ground controls.
- Result: The ground controls LCD display will show the following: SOFTWARE UPDATE CONNECT ETHERNET
- Locate the diagnostic port on the side of the GCON. Remove one of the fasteners securing the cover and set aside. Loosen the other fastener. Do not remove it.
- Connect one end of a CAT5 Ethernet cable into the diagnostic port. Connect the other end into a PC or laptop.
- Result: The ground controls LCD display will show the following: OPEN WEB BROWSER <IP ADDRESS>
- Read and record the IP address. Note: The display will only show the IP address for 3 seconds. Press the scroll up button to display the IP address for another 3 seconds.
- Launch a web browser such as Internet Explorer ®, Chrome ® or Firefox ® on your PC or laptop. Type the IP address from step 7 into the web browser address bar and press enter.
- Result: The following screen will be displayed.
- Enter the following username and password then select OK.
Username: smart.link
Password: SL1000
Note: The username and password are case sensitive. - Result: The following screen will be displayed.
- Select the Software tab at the header bar.
- Result: The following screen will be displayed.
- Select the Update Machine Software button.
- Result: The following screen will be displayed.
- Select the Choose File button and navigate to the downloaded Genie Flash file (.gff). Note: Verify it is the correct flash file.
- Select the Load Flash File button to verify the file is a .gff file.
- Result: The following screen will be displayed.
- Select the Reprogram Device(s) button to start the ECM software update.
- Result: The following screen will be displayed after the software update is complete. Note: Do not turn off power while the ECM is being reprogrammed.
- Select the Run Application button to exit the software update mode.
- Push in the red Emergency Stop button and disconnect the CAT5 cable from the GCON.
- Secure the diagnostic port cover using the retaining fasteners removed in step 5. Do not over tighten.
- Perform a function test. Refer to the Operator's Manual on your machine.
- Return the machine to service.
Procedure
Machine Application Mode Steps:
- Open the GCON compartment. Note: Some models will require opening the ground control box to access the GCON.
- Turn the key switch to ground controls or platform controls and pull out the red Emergency Stop button to the on position at both ground and platform controls.
- Locate the diagnostic port on the side of the GCON. Remove one of the fasteners securing the cover and set aside. Loosen the other fastener. Do not remove it.
- Connect one end of a CAT5 Ethernet cable into the diagnostic port. Connect the other end into a PC or laptop.
- Result: The ground controls LCD display will show the following: OPEN WEB BROWSER <IP ADDRESS>
- Read and record the IP address. Note: The display will only show the IP address for 3 seconds. Press the scroll up button to display the IP address for another 3 seconds.
- Launch a web browser such as Internet Explorer ®, Chrome ® or Firefox ® on your PC or laptop. Type the IP address from step 5 into the web browser address bar and press enter.
- Result: The following screen will be displayed.
- Enter the following username and password then select OK.
Username: smart.link
Password: SL1000
Note: The username and password are case sensitive. - Result: The following screen will be displayed.
- Select the Software tab at the header bar.
- Result: The following screen will be displayed.
- Select the Update Machine Software button.
- Result: The following screen will be displayed.
- Select the Choose File button and navigate to the downloaded Genie Flash file (.gff). Note: Verify it is the correct flash file.
- Select the Load Flash File button to verify the file is a .gff file.
- Result: The following screen will be displayed.
- Select the Reprogram Device(s) button to start the ECM software update.
- Result: The following screen will be displayed after the software update is complete. Note: Do not turn off power while the ECM is being reprogrammed.
- Select the Run Application button to exit the software update mode.
- Push in the red Emergency Stop button and disconnect the CAT5 cable from the GCON.
- Secure the diagnostic port cover using the retaining fasteners removed in step 5. Do not over tighten.
- Perform a function test. Refer to the Operator's Manual on your machine.
- Return the machine to service.
File Info : application/pdf, 8 Pages, 1.80MB
DocumentDocumentReferences
Related Documents
![]() |
Genie SmartLink Software Installation Instructions Installation instructions for Genie SmartLink Software, covering models like GR, GRC, QS, GS, and X series. Details procedures for Bootloader Mode and Machine Application Mode for software updates. |
![]() |
Genie GS Series Scissor Lifts Service and Repair Manual Comprehensive service and repair manual for Genie GS series scissor lifts, covering models GS-1530, GS-1532, GS-1930, GS-1932, GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-3246, and GS-4047. Includes repair procedures, fault codes, electrical and hydraulic schematics, and safety guidelines. |
![]() |
Genie GS Series Scissor Lift Operator's Manual - Safety, Operation, and Specifications This operator's manual provides comprehensive safety guidelines, operating instructions, inspection procedures, maintenance information, and technical specifications for Genie GS series scissor lifts, including models GS-1530, GS-1930, GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-3246, and GS-4047. Learn how to safely operate and maintain your Genie scissor lift. |
![]() |
Genie GS Series Service and Repair Manual Comprehensive service and repair manual for Genie GS series scissor lifts, covering repair procedures, fault codes, electrical and hydraulic schematics, and troubleshooting for models GS-1330m, GS-1530/1532, GS-1930/1932, GS-1932 XH, GS-2032/2632/3232, GS-2046/2646/3246/4046, GS-2646 XH / 3246 XH, and GS-4655. |
![]() |
Genie GS Series Operator's Manual: Operation, Safety, and Transport Comprehensive operator's manual for Genie GS Series scissor lifts, covering operation, safety procedures, maintenance, and transport guidelines. Includes model information for GS-1530, GS-1532, GS-1930, GS-1932, GS-1932 XH, GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-2646 XH, GS-3246, GS-3246 XH, GS-4046. |
![]() |
Genie GS-2669BE, GS-3369BE, GS-4069BE Operator's Manual | Safety & Operation Guide Comprehensive operator's manual for Genie GS-2669BE, GS-3369BE, and GS-4069BE Bi-Energy Power aerial work platforms. Covers safety, operation, inspections, maintenance, and specifications. |
![]() |
Genie GS-3384, GS-3390, GS-4390, GS-5390 Parts Manual This comprehensive parts manual details the components and part numbers for Genie's GS-3384, GS-3390, GS-4390, and GS-5390 series scissor lifts. It serves as an essential resource for maintenance, repair, and part identification for these aerial work platforms manufactured by Genie, a Terex Brand. |
![]() |
Genie GS-3384, GS-3390, GS-4390, GS-5390 Operator's Manual This manual provides operating instructions and safety guidelines for Genie GS-3384, GS-3390, GS-4390, and GS-5390 series aerial work platforms. It covers general safety, hazard classifications, operating procedures, maintenance, and specifications. |