User Manual for INVERTER models including: WVC-600, 600W Solar Inverter
Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Loss of power at night Total current harmonics Appearance and technical features Temperature range Size(L×W×H) Net amount Waterproof grade Heat dissipation mode Communication mode Power transmission mode monitoring system <0.5W <5%-40 ...
Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Loss of power at night Total current harmonics Appearance and technical features Temperature range Size(L×W×H) Net amount Waterproof grade Heat dissipation mode Communication mode Power transmission mode monitoring system
File Info : application/pdf, 2 Pages, 2.85MB
DocumentDocumentMicro inverter Use Manual Micro Inverter WVC-600 WVC series communication type intelligence Micro grid-connected inverter Micro inverter Use Manual model Maximum input power WVC-600 600Watt Output voltage mode 120/230V Auto switch PV Open circuit voltage 30-60VOC Operating voltage range 22-60V Starting voltage range 22-60V short-circuit current 30A Maximum working current 24A Output parameters @120V Output peak power 600Watt @230V 600Watt Rated output power 580Watt 580Watt Output current 5A 2.6A AC voltage range 80-160VAC 180-280VAC AC frequency range 48-51Hz/58-61Hz 48-51Hz/58-61Hz Power factor >95% >95% Number of branch connections. 6PCSSingle 12PCSSingle Output efficiency @120V @230V Static MPPT efficiency 99.5% 99.5% Max output efficiency 95% 95% Loss of power at night <0.5W <0.5W Total current harmonics <5% Appearance and technical features <5% Temperature range -40°C to +65°C SizeL×W×H 283mm×200mm×41.6mm Net amount 1.56kg Waterproof grade Ip65 NEMA3R Heat dissipation mode Self-cooling Communication mode 433MHz/WiFi Power transmission mode Reverse transmission,Load priority monitoring system Electromagnetic Detection Mobile phone APPBrowser EN61000-6-1:2007 EN6100-6-3:2007+A1:2011+AC:2012 Power Grid standard EN50549-1EN 50549-2NBR 16149:2013UL1741 Power grid detection IEC/EN 62109-1 IEC/EN 62109-2 IEC 62116IEEE 1547 Certificate CEETLINMETROPatented technology Packing weight Specifications EachPacking Box5PCS weight 2.8G 14G Size 342×240×115mm 440×380×260mm Micro inverter Use Manual System diagram 433MHz WiFi Modem KDM Cloud server WiFi APP Contorl Computer Photovoltaic module Micro inverter Switch Meter Power Grid Description of the connector and cable core of the micro inverter Note: You can purchase a professionally customized AC bus with a T-type connector. Use this AC bus as the AC bus for each branch. Connect it hand in hand to form a modular micro-inverter branch wiring system. LED indicator function of micro inverter Micro inverter Use Manual Micro inverter Use Manual WVC-600 micro inverter installation drawing APP Contorl Appearance description of micro inverter Micro inverter fixing hole 22-60V DC Input connected to PV module AC output terminal, connect previous / next / connect to grid access point + Independent ground connection to fixed holes Status indicator + 22-60V DC Input connected to PV module Antenna AC output terminal, connect previous / next / connect to grid access point Screw Kit Iinstructions AC Plug Accessories of micro inverter Preparation before installation: 1Please install Kayden micro inverter series products as shown in the following figure. 2Please note that only qualified personnel can install and / or replace Kaideng micro-inverters. 3Before installing or using Kaideng Micro Inverter, please rea -d all instructions and technical instructions and the warning mark system and photovoltaic array on Kay Microinverter. 5Implement all national electrical codes (NEC), ANSI / NFPA 70 in accordance with all local electrical codes and all relev -ant regulations. 6Please do not try to repair Kaideng micro-inverter. It does n -ot contain user-serviceable parts. If it fails, please contact Kaideng customer service to obtain the ID number and start the replacement process. Tampering or opening the Kaideng micro inverter will invalidate the warranty. 4When installing the inverter handshake cable, please plan th -at your AC branch circuit cannot exceed the current limit, so that the maximum number of micro-inverters in each branch can be reasonably allocated. Inverter model Number of branches WVC-295 30PCS WVC-300 30PCS WVC-350 25PCS 7Please make sure that the installation operation is performed before the AC power is disconnected, and do not install the K -aideng micro-inverter with power on. 8After the installation of the power station is completed, ple -ase install a ground wire on the photovoltaic support, inst -all and use a lightning protection and / or surge suppress -ion equipment protection system in the AC junction box. It is very important to have a switch device that automatically protects against lightning strikes and surges. WVC-600 WVC-700 WVC-1000 WVC-1200 WVC-1400 WVC-1600 WVC-2000 WVC-2400 WVC-2800 15PCS 12PCS 10PCS 8PCS 6PCS 5PCS 5PCS 3PCS 3PCS 9 In addition to Kaideng Energy's WVC series micro-invert -ers, you must also purchase photovoltaic brackets / AC boxes / electrical cables and other related materials. The current of each channel of the WVC series micro-inverte -rs at the branch of the installed circuit cannot exceed 40 Amp, if the rated current is exceeded, it may lead to an un -safe factor. 10Check if you still have the following related equipment: AC junction box, tools: screwdriver, wire cutter, voltmeter, tor -que wrench, socket and wrench for installing hardware, etc. *Each region may be different. Please refer to local requirem ents to define the number of micro-inverters per branch in your area. Connect up to 12 units Inverter Inverter 2 Inverter 1 WiFi Modem KDM Cloud Server 433MHz WiFi System support: Power monitoring system WiFi Router Switch Electric meter Grid Inverter installation steps Step1 Install the inverter on the bracket of the photovoltaic panel with the screws pro -vided with the machine, as shown in the fo -llowing figure: Step2 Connect the positive and negative poles Step3 Open the waterproof cover of the AC output of the DC connection MC4 plug on the photovo connector of the inverter and connect the AC cable -ltaic board to the DC input terminal of the inv to the AC waterproof plug. The connection method -erter, as shown below: is as shown in the plug connection diagram: Solar Panel Mc4 Solar Panel Mc4 AC Cable AC Cable Neutral (blue) Live wire (brown) (PIN 2) 31 (PIN 1) 2 Ground (yellow-green) (PIN 3) Step 4 Connect the AC output cable to the AC main cable; Step 5 Repeat steps 1 to 3, install and connect all inverters; Step 6 Connect the AC main cable to the utility grid to start your green energy journey. Note: Before installing WVC series micro inverter products, please read this manual and pay attention to the installation details. This manual contains important instructions that should be followed when installing and maintainingReduce the risk of electric shock and ensure safe installation and ope -ration of Kaideng MicroInverters,Always follow the following safety symbols present in this document to indicate hazardous conditions and important safety Instructions. Wiring Diagram WVC-600 Triple Phase Array 1-1 Maximum number of micro inverters per array branch: 12 pcs Array 1-N Maximum number of micro inverters per array branch: 12 pcs On Grid L1 L2 L3 N Array 2-1 Maximum number of micro inverters per array branch: 12 pcs Array 2-N Maximum number of micro inverters per array branch: 12 pcs Array 3-1 Maximum number of micro inverters per array branch: 12 pcs Array 3-N Maximum number of micro inverters per array branch: 12 pcs L 1 BROWN BLUE N GREEN&YELLOW G L 2 BROWN BLUE N GREEN&YELLOW G L 3 BROWN BLUE N GREEN&YELLOW G Meter L1 L3 Electric box G Micro inverter Use Manual Micro inverter Use Manual Distribution network preparation tool When installing the KDM monitoring system, it is necessary to configure the KDM monitoring system in advance. Please use the two-dimensional scanning function to download and install the MxEasyLink network distribution tool. (IOS SYSTEM Download Password:Mxchip) Android IOS Monitoring system distribution network instructions Press the reset button (A-1), release the button (A-2) when the indicator light flashes quickly, and operate in the MxEasyLink interface of the mobile phone. (Please explain the parameters below for Android and IOS) When the network configuration is completed, the Reday and Link lights of the collector will become a constant light display (A-3). KDM Monitoring System Ready to work: Install the "KDM Monitoring System" tool on your Android Phone Download: http://jzi6.cn/MiTp6q (You can scan the QR to Download) Note: This application only supports Android. If you have an Iphone, please operate in your browser and log in to the website: kdm.kaidengdg.com Create account Android Open KDM software D-1, first use KDM monitoring system, please click Register D-2, register KDM account and save D-3 (A-1) Reset button (A-2) Flashes quickly (A-3) Long bright Android client configuration Connect the wireless network of your mobile phone to your home wireless signal source and open the MxEasyLink client B-1, fill in the wireless SSID and password in the software. When the collector is in the (A-2) state, click the send command button B-2, The system will automatically configure the network until the data string is received, and the network configuration is successful (B-3). (B-1) (B-2) (B-3) IOS Client configuration Open the MxEasyLink client, click "+" in the upper right corner C-1 to create network configuration settings and fill in the SSID and password, and select the mode as "EasyLink AWS". When the collector flashes quickly as shown in Figure(A-2), click "Start EasyLink AWS Mode" button is like C-2. When the distribution network receives the module data and returns C-3. Click "Confirm" to complete the network configuration. (C-1) (C-2) (C-3) (D-1) (D-2) (D-3) ADD Station After logging account, click "Add Station" Like Figure E-1, fill in the Information and fill in the 8-digit code on the back of the Modem into the corresponding items. For example, E-2. For the electrical box option, please select "None", and fill in "1" "Figure E-3 WIFI-MODEM ID:40009E13 40009E13 (8-bit ID) (No) (1) (E-1) (E-2) (E-3) ADD Inverter When the creation of the power station is completed, the page will automatically jump to the interface for adding an inverter (make sure the inverter has been installed correctly), fill in the 8-digit ID on the inverter and click Add such as F1, after the addition is completed You can return to query the working status of the inverter F-2 and view the basic operating status of the power station F-3. 30000C01 ID30000C01 (F-1) (F-2) (F-3) * The Wi-Fi modem changes its working mode (press and hold the reset button until the following display appears): TCP/IP mode: Release the Reday indicator from "offonoff"; Internet of Things mode: Release the Reday indicator from "offon"; Micro inverter Use ManualCorel PDF Engine Version 16.1.0.843 CorelDRAW X6