User Manual for INVERTER models including: WVC-600, 600W Solar Inverter

WVC-600-A3黑白打印

Micro Inverter - en.kaidengdg.com

Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Loss of power at night Total current harmonics Appearance and technical features Temperature range Size(L×W×H) Net amount Waterproof grade Heat dissipation mode Communication mode Power transmission mode monitoring system <0.5W <5%-40 ...

Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Micro inverter Use Manual Loss of power at night Total current harmonics Appearance and technical features Temperature range Size(L×W×H) Net amount Waterproof grade Heat dissipation mode Communication mode Power transmission mode monitoring system

UserManual.wiki


File Info : application/pdf, 2 Pages, 2.85MB

PDF preview unavailable. Download the PDF instead.

5ff57c266c609
Micro inverter Use Manual
Micro Inverter

WVC-600

WVC series communication type intelligence Micro grid-connected inverter

Micro inverter Use Manual

model
Maximum input power

WVC-600
600Watt

Output voltage mode

120/230V Auto switch

PV Open circuit voltage 30-60VOC

Operating voltage range 22-60V

Starting voltage range 22-60V

short-circuit current

30A

Maximum working current 24A

Output parameters @120V

Output peak power

600Watt

@230V
600Watt

Rated output power

580Watt

580Watt

Output current

5A

2.6A

AC voltage range

80-160VAC

180-280VAC

AC frequency range

48-51Hz/58-61Hz

48-51Hz/58-61Hz

Power factor

>95%

>95%

Number of branch connections. 6PCSSingle

12PCSSingle

Output efficiency @120V

@230V

Static MPPT efficiency 99.5%

99.5%

Max output efficiency

95%

95%

Loss of power at night <0.5W

<0.5W

Total current harmonics <5% Appearance and technical features

<5%

Temperature range

-40°C to +65°C

SizeL×W×H

283mm×200mm×41.6mm

Net amount

1.56kg

Waterproof grade

Ip65 NEMA3R

Heat dissipation mode Self-cooling

Communication mode 433MHz/WiFi

Power transmission mode Reverse transmission,Load priority

monitoring system Electromagnetic Detection

Mobile phone APPBrowser EN61000-6-1:2007 EN6100-6-3:2007+A1:2011+AC:2012

Power Grid standard

EN50549-1EN 50549-2NBR 16149:2013UL1741

Power grid detection

IEC/EN 62109-1 IEC/EN 62109-2 IEC 62116IEEE 1547

Certificate

CEETLINMETROPatented technology

Packing weight

Specifications

EachPacking

Box5PCS

weight

2.8G

14G

Size

342×240×115mm

440×380×260mm

Micro inverter Use Manual

System diagram

433MHz

WiFi Modem

KDM Cloud server

WiFi

APP Contorl Computer

Photovoltaic module

Micro inverter

Switch

Meter

Power Grid

Description of the connector and cable core of the micro inverter

Note: You can purchase a professionally customized AC bus with a T-type connector. Use this AC bus as the AC bus for each branch. Connect it hand in hand to form a modular micro-inverter branch wiring system.
LED indicator function of micro inverter

Micro inverter Use Manual

Micro inverter Use Manual

WVC-600 micro inverter installation drawing

APP Contorl

Appearance description of micro inverter

Micro inverter fixing hole

22-60V DC Input connected to PV module
AC output terminal, connect previous / next / connect to grid access point

+

Independent ground connection to fixed holes

Status indicator

+ 22-60V DC Input connected to PV module
Antenna
AC output terminal, connect previous / next / connect to grid access point

Screw Kit Iinstructions

AC Plug
Accessories of micro inverter

Preparation before installation:

1Please install Kayden micro inverter series products as shown in the following figure.
2Please note that only qualified personnel can install and / or replace Kaideng micro-inverters.
3Before installing or using Kaideng Micro Inverter, please rea -d all instructions and technical instructions and the warning mark system and photovoltaic array on Kay Microinverter.

5Implement all national electrical codes (NEC), ANSI / NFPA 70 in accordance with all local electrical codes and all relev -ant regulations.
6Please do not try to repair Kaideng micro-inverter. It does n -ot contain user-serviceable parts. If it fails, please contact Kaideng customer service to obtain the ID number and start the replacement process. Tampering or opening the Kaideng micro inverter will invalidate the warranty.

4When installing the inverter handshake cable, please plan th -at your AC branch circuit cannot exceed the current limit, so that the maximum number of micro-inverters in each branch can be reasonably allocated.

Inverter model

Number of branches

WVC-295

30PCS

WVC-300

30PCS

WVC-350

25PCS

7Please make sure that the installation operation is performed before the AC power is disconnected, and do not install the K -aideng micro-inverter with power on.
8After the installation of the power station is completed, ple -ase install a ground wire on the photovoltaic support, inst -all and use a lightning protection and / or surge suppress -ion equipment protection system in the AC junction box. It is very important to have a switch device that automatically protects against lightning strikes and surges.

WVC-600 WVC-700 WVC-1000 WVC-1200 WVC-1400 WVC-1600 WVC-2000 WVC-2400 WVC-2800

15PCS 12PCS 10PCS 8PCS 6PCS 5PCS 5PCS 3PCS 3PCS

9 In addition to Kaideng Energy's WVC series micro-invert -ers, you must also purchase photovoltaic brackets / AC boxes / electrical cables and other related materials. The current of each channel of the WVC series micro-inverte -rs at the branch of the installed circuit cannot exceed 40 Amp, if the rated current is exceeded, it may lead to an un -safe factor.
10Check if you still have the following related equipment: AC junction box, tools: screwdriver, wire cutter, voltmeter, tor -que wrench, socket and wrench for installing hardware, etc.

*Each region may be different. Please refer to local requirem ents to define the number of micro-inverters per branch in your area.

Connect up to 12 units Inverter

Inverter 2

Inverter 1

WiFi Modem

KDM Cloud Server

433MHz

WiFi

System support:
Power monitoring system

WiFi Router
Switch

Electric meter

Grid

Inverter installation steps

Step1 Install the inverter on the bracket of the photovoltaic panel with the screws pro -vided with the machine, as shown in the fo -llowing figure:

Step2 Connect the positive and negative poles Step3 Open the waterproof cover of the AC output

of the DC connection MC4 plug on the photovo connector of the inverter and connect the AC cable

-ltaic board to the DC input terminal of the inv to the AC waterproof plug. The connection method

-erter, as shown below:

is as shown in the plug connection diagram:

Solar Panel Mc4

Solar Panel Mc4

AC Cable

AC Cable

Neutral (blue)

Live wire (brown)

(PIN 2)

31

(PIN 1)

2

Ground (yellow-green) (PIN 3)

Step 4 Connect the AC output cable to the AC main cable; Step 5 Repeat steps 1 to 3, install and connect all inverters; Step 6 Connect the AC main cable to the utility grid to start your green energy journey.
Note: Before installing WVC series micro inverter products, please read this manual and pay attention to the installation details. This manual contains important instructions that should be followed when installing and maintainingReduce the risk of electric shock and ensure safe installation and ope -ration of Kaideng MicroInverters,Always follow the following safety symbols present in this document to indicate hazardous conditions and important safety Instructions.

Wiring Diagram WVC-600 Triple Phase

Array 1-1 Maximum number of micro inverters per array branch: 12 pcs

Array 1-N Maximum number of micro inverters per array branch: 12 pcs

On Grid
L1 L2 L3 N

Array 2-1 Maximum number of micro inverters per array branch: 12 pcs

Array 2-N Maximum number of micro inverters per array branch: 12 pcs

Array 3-1 Maximum number of micro inverters per array branch: 12 pcs

Array 3-N Maximum number of micro inverters per array branch: 12 pcs

L 1 BROWN



BLUE

 N

GREEN&YELLOW  G

L 2 BROWN



BLUE

 N

GREEN&YELLOW  G

L 3 BROWN



BLUE

 N

GREEN&YELLOW  G

Meter

L1

L3

Electric box

G

Micro inverter Use Manual

Micro inverter Use Manual

Distribution network preparation tool
When installing the KDM monitoring system, it is necessary to configure the KDM monitoring system in advance. Please use the two-dimensional scanning function to download and install the MxEasyLink network distribution tool. (IOS SYSTEM Download Password:Mxchip)

Android

IOS

Monitoring system distribution network instructions
Press the reset button (A-1), release the button (A-2) when the indicator light flashes quickly, and operate in the MxEasyLink interface of the mobile phone. (Please explain the parameters below for Android and IOS) When the network configuration is completed, the Reday and Link lights of the collector will become a constant light display (A-3).

KDM Monitoring System
Ready to work: Install the "KDM Monitoring System" tool on your Android Phone Download: http://jzi6.cn/MiTp6q (You can scan the QR to Download)
Note: This application only supports Android. If you have an Iphone, please operate in your browser and log in to the website: kdm.kaidengdg.com

Create account

Android

Open KDM software D-1, first use KDM monitoring system, please click Register D-2, register KDM account and save D-3

(A-1)

Reset button

(A-2)

Flashes quickly

(A-3)

Long bright

Android client configuration
Connect the wireless network of your mobile phone to your home wireless signal source and open the MxEasyLink client B-1, fill in the wireless SSID and password in the software. When the collector is in the (A-2) state, click the send command button B-2, The system will automatically configure the network until the data string is received, and the network configuration is successful (B-3).

(B-1)

(B-2)

(B-3)

IOS Client configuration

Open the MxEasyLink client, click "+" in the upper right corner C-1 to create network configuration settings and fill in the SSID and password, and select the mode as "EasyLink AWS". When the collector flashes quickly as shown in Figure(A-2), click "Start EasyLink AWS Mode" button is like C-2. When the distribution network receives the module data and returns C-3. Click "Confirm" to complete the network configuration.

(C-1)

(C-2)

(C-3)

(D-1)

(D-2)

(D-3)

ADD Station

After logging account, click "Add Station" Like Figure E-1, fill in the Information and fill in the 8-digit code on the back of the Modem into the corresponding items. For example, E-2. For the electrical box option, please select "None",
and fill in "1" "Figure E-3

WIFI-MODEM ID:40009E13

40009E13

(8-bit ID)

(No) (1)

(E-1)

(E-2)

(E-3)

ADD Inverter

When the creation of the power station is completed, the page will automatically jump to the interface for adding an inverter (make sure the inverter has been installed correctly), fill in the 8-digit ID on the inverter and click Add such as F1, after the addition is completed You can return to query the working status of the inverter F-2 and view the basic operating status of the power station F-3.

30000C01

ID30000C01

(F-1)

(F-2)

(F-3)

* The Wi-Fi modem changes its working mode (press and hold the reset button until the following display appears): TCP/IP mode: Release the Reday indicator from "offonoff"; Internet of Things mode: Release the Reday indicator from "offon";

Micro inverter Use Manual


Corel PDF Engine Version 16.1.0.843 CorelDRAW X6