American Standard Nv-Series and P- Series Catalog 05-2021 Nv-Series and P-Series Catalog
Winter 2021
Doing Our Part to Create a Better Future
Core Environmental Policy
The Mitsubishi Electric Group promotes sustainable development and commits to protecting and restoring the global environment through technology, all business activities, and our employees' actions.
Making Positive Contributions to the Earth and its People through Technology and Action
Preventing Global Warming
· Reduce CO2 emissions from product usage by 30% · Reduce total CO2 emissions from production by 30% · Aim to reduce CO2 emissions from power generation
Creating a Recycling-Based Society
· Reduce, reuse and recycle product resources by 30% · Eliminate manufacturing waste going to landfills
Fostering Environmental Awareness Ensuring Harmony with Nature
Mitsubishi Electric reflects the essence of this policy and vision in all aspects of its heating and air conditioning business.
Preventing Global Warming
Heat pump technology inspires Mitsubishi Electric to design air conditioners that combine comfort and ecology. Mitsubishi Electric develops technologies to achieve greater efficiency in heat pump operation.
1. Inverter 2. 3D i-see Sensor® 3. Flash Injection
Comfort
Faster start-up and more stable indoor temperature than non-inverter units.
Ecology
Fewer On/Off operations than with non-inverter
systems.
When enabled, the sensor detects the location of people within a space.
Customized airflow settings to move air directly toward or away from individuals
provides personalized comfort.
The sensor detects the number of people in the space. When the space is detected to be vacant, the unit enters Energy Saving operation or may be set to automatically turn off.
Achieves high heating capacity even at low temperatures plus faster start-up compared to conventional inverters.
Expands the geographical region covered by heat pump heating systems.
Heat Pump Principle (When Heating) <Case of COP of 5.0>
Refrigerant and Heat Circulation
3,600 BTU/H
Electrical Energy Output
Compressor compresses the refrigerant which raises the temperature
68° F Outdoors
176° F Compressor
Indoors
14,400 BTU/H
Heat absorbed from the air
Evaporator
Condenser
Expansion Valve
18,000 BTU/H
Heat output
86° F
41° F
Expansion valve expands refrigerant to lower the temperature
122° F
Heat
Contents
Product Overview
Product Lineup...................................................................................................................6 - 11 Quality and Testing.........................................................................................................12 - 13 Inverter Technologies......................................................................................................14 - 15 Features............................................................................................................................16 - 29
Nv-Series
Nv-Series........................................................................................................................... 30 - 69
P-Series
P-Series...........................................................................................................................70 - 107
Multi-Zone Series
Nv-Series : Multi-zone Outdoor Units.........................................................................108 - 115
Conditions
Conditions for Specifications...............................................................................................117 Piping Installation........................................................................................................118 - 121 Explanation of Terminology.................................................................................................122
Appendix
Installation in Cold Regions.........................................................................................125 -126 System Control..............................................................................................................127 - 131 Optional Parts..............................................................................................................132 - 147 Additional Information...............................................................................................152 - 156 Correction Factors........................................................................................................157 - 161 External Dimensions.....................................................................................................162 - 173
Nv-Series Model Reference Guide
N A X S PH 1 2 A 1 1 2 A *
Family N = Nv-Series
Brand A = American Standard
Function/Type X = Heat Pump (INVERTER) V = Indoor matched with
Various Outdoor Y = Cooling Only (INVERTER)
Unit Configuration Outdoor Outdoor: S = Single-zone Outdoor M = Multi-zone Outdoor Indoor: A = Convertible Air Handler C = Cassette 2'x2' D = Horizontal-ducted F = Floor Unit U = EZ FITTM Ceiling Cassette W = High-wall Unit
Series EL = Entry Level KH = Non-highwall Hyper-heating KS = Non-highwall Series MT = Mid Tier MX = Standard Multi-zone PH = Hyper-heating ST = Standard Line SH = Standard Line Hyper-heating PB = Hyper-heating with Base Heater PF = Hyper-heating for Floor Standing
Minor Service Change (parts change, no function/spec change)
Major Change (compressor, software, related to features/ performance etc)
Voltage 1 = 115V, 1ph 2 = 208/230V,1ph
Max Number of Zones 1 = Single-zone 2+ = Multi-zone
UL/Non-UL 1 = US / UL Rated 2 = Non US/ Non-UL Rated
Generation Change A, B, C
Capacity (Nominal) BTU/H (X 1,000) 06 = 6,000 09 = 9,000 12 = 12,000 15 = 15,000 18 = 18,000 24 = 24,000 30 = 30,000 36 = 36,000 42 = 42,000 48 = 48,000 60 = 60,000
· Designed for residential applications · User-friendly zoned cooling and heating solutions for single- or multi-room applications or the whole home · Hyper-heating INVERTER-driven outdoor units can provide high heating performance at lower ambient
temperatures · Many ENERGY STAR® certified models
6 Product Overview
P-Series Model Reference Guide
P U Z - A 24 NHA 7 - BS
Family P = Professional
Type K = Wall-mounted Indoor Unit C = Ceiling-suspended Indoor Unit L = Ceiling cassette Indoor Unit E = Horizontal-ducted Indoor Unit V = Multi-position Air Handler U = Single-zone Outdoor Unit
Cooling Only / Heat Pump Y = Cooling Only (INVERTER-driven) Z = Heat Pump (INVERTER-driven) A = Both Heating And Cooling
BS = S eacoast Protection
Model Version
Control Method A = A-control Generation H = Model Generation
Compressor Voltage N = 208/230V
Generation A = Standard heat pump HA = Hyper-Heating INVERTER Unit
Capacity (Nominal) BTU/H (X 1,000)
· Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms
· Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures
· Long lineset lengths · Outside air intake on PLA, PCA, PEAD and PVA models · P-Series ducted units have higher static than most Nv-Series, allowing for design flexibility
Product Overview 7
Nv-Series Model Reference Guide
Model Name
6,000 BTU/H
9,000 BTU/H
12,000 BTU/H
15,000 BTU/H
18,000 BTU/H
24,000 BTU/H
30,000 BTU/H
36,000 BTU/H
NAXWPH Model
·····
MSZ-EF Model
·W·S·B *1
·W·S·B *1
·W·S·B *1
·W·S·B *1
NAXWST Model
·*1 · · · · · · ·
Wall-mounted
NAXWMT Model
· · · · · *2
*2
*2
*2
*2
NAXWMT 115V Model
· · *2
*2
NAXWEL Model
· · *2
*2
· · *2
*2
NAYWST Model
COOLING ONLY
· · · · · · · *2
*2
*2
*2
*2
*2
*2
Floor-mounted
NAXFKS Model
····
EZ FIT® Ceiling Cassette
NAXUKS Model
··
·
Multi-position Air Handler
NAXAMT Model
·
····
Ceiling Cassette
NAXCKS Model
· · · ·*2
Horizontalducted
NAXDKS Model
····
8 Product Overview
*1 MX connection only *2 Single-zone connection only W·S·B: Indoor units are available in three colors; White, Silver, and Black.
Model Name
Capacity
Wall-mounted
Floormounted
EZ FIT® Ceiling Cassette
Four-way Ceiling Cassette
Horizontal-ducted
Multi-position Air Handler
Heat Pump
NAXMMX20A122** up to 2 indoor units
20,000 BTU/H [1-phase]
NAXMMX24A132** up to 3 indoor units
24,000 BTU/H [1-phase]
NAXMMX30A132** up to 3 indoor units
30,000 BTU/H [1-phase]
NAXMMX36A142** up to 4 indoor units
36,000 BTU/H [1-phase]
NAXMMX42A152** up to 5 indoor units
42,000 BTU/H [1-phase]
NAXMMX48A182** *3 up to 8 indoor units
48,000 BTU/H [1-phase]
NAXMMX60A182** *3 up to 8 indoor units
60,000 BTU/H [1-phase]
NAXMPH20A122** up to 2 indoor units
20,000 BTU/H [1-phase]
NAXMPH24A132** up to 3 indoor units
24,000 BTU/H [1-phase]
NAXMPH30A132** up to 3 indoor units
30,000 BTU/H [1-phase]
NAXMPH36A142** *3 up to 4 indoor units
36,000 BTU/H [1-phase]
NAXMPH42A152** *3 up to 5 indoor units
42,000 BTU/H [1-phase]
NAXMMX48A182** *3 up to 8 indoor units
48,000 BTU/H [1-phase]
WPH 06/09/12/15
MSZ-EF 09/12/15 NAXWST 06/09/
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18 NAXWST06/ 09/12/15/18
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15
MSZ-EF 09/12/15 NAXWST 06/09/12/15
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
WPH 06/09/12/15/18
MSZ-EF 09/12/15/18
NAXWST 06/09/12/15/18/24
FKS 09/12/15
FKS 09/12/ 15/18
FKS 09/12/ 15/18
FKS 09/12/ 15/18
FKS 09/12/ 15/18
FKS 09/12/ 15/18
FKS 09/12/ 15/18
FKS 09/12/15
FKS 09/12/15/18
FKS 09/12/15/18
FKS 09/12/15/1
FKS 09/12/15/18
FKS 09/12/15/18
UKS 09/12
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
UKS 09/12/18
CKS 09/12
CKS 09/12/15 PLA-A18
CKS 09/12/15 PLA-A18
CKS 09/12/15 PLA-A18
CKS 09/12/15 PLA-A18
CKS 09/12/15
PLA-A 12/18/24/30/36
CKS 09/12/15
PLA-A 12/18/24/30/36
CKS 09/12
CKS 09/12/15 PLA-A18
CKS 09/12/15 PLA-A18
CKS 09/12/15 PLA-A12/18/ 24/30/36
CKS 09/12/15 PLA-A12/18/ 24/30/36
CKS 09/12/15 PLA-A12/18/ 24/30/36
DKS 09/12/15 PEAD-A12
AMT 12
DKS 09/12/15/18 PEAD-A12/18
AMT 12/18
DKS 09/12/15/18 PEAD-A12/18/24
AMT 12/18/24
DKS 09/12/15/18 PEAD-A12/18/24
AMT 12/18/ 24/30/36
DKS 09/12/15/18 PEAD-A12/18/24
DKS 09/12/15/18
PEAD-A 12/18/24/30/36
DKS 09/12/15/18
PEAD-A 12/18/24/30/36
DKS 09/12/15 PEAD-A12
AMT 12/18/ 24/30/36
AMT 12/18/ 24/30/36
AMT 12/18/ 24/30/36
AMT1 2
DKS 09/12/15/18 PEAD-A12/18
AMT 12/18
DKS 09/12/15/18 PEAD-A12/18/24
AMT 12/18/24
DKS 09/12/15/18 PEAD-A12/18/
24/30/36
DKS 09/12/15/18 PEAD-A12/18/
24/30/36
DKS 09/12/15/18 PEAD-A12/18/
24/30/36
AMT 12/18/24/30/36
AMT 12/18/24/30/36
AMT 12/18/24/30/36
Hyper-heating
*3 The number of indoor units are limited when connected to PLA. For more information, please refer to pg.85-86 The number of ducted models (AMT, DKS, PEAD) connectable may be limited based on the outdoor unit and combination - refer to the compatibility charts.
Ceiling Suspended
PCA-A24 PCA-A24 PCA-A24
PCA-A24
Product Overview 9
P-Series
Cooling Only Models (PUY)
Four-way Ceiling Cassette
Model Name PLA Model
Wall-mounted
PKA Model
Multi-position Air Handler
PVA Model
12,000 BTU/H
· ·
·
18,000 BTU/H
· ·
·
24,000 BTU/H
· ·
·
30,000 BTU/H
· ·
·
36,000 BTU/H
· ·
·
42,000 BTU/H
·
·
Horizontal-ducted
PEAD Model
Ceiling-suspended
PCA Model
······ ····
Heat Pump Models (PUZ)
Four-way Ceiling Cassette
Model Name PLA Model
Wall-mounted
PKA Model
Multi-position Air Handler
PVA Model
Horizontal-ducted
PEAD Model
Ceiling-suspended
PCA Model
10 Product Overview
12,000 BTU/H
·
18,000 BTU/H
·
24,000 BTU/H
·
30,000 BTU/H
·
36,000 BTU/H
·
42,000 BTU/H
·
·····
······
······ ····
Hyper-heating Models (PUZ-HA)
Four-way Ceiling Cassette
Model Name PLA Model
24,000 BTU/H
·
PKA Model
Wall-mounted
·
PVA Model
Multi-position Air Handler
·
PEAD Model
Horizontal-ducted
·
PCA Model
Ceiling-suspended
·
30,000 BTU/H
· · · · ·
36,000 BTU/H
· · · · ·
42,000 BTU/H
·
· · ·
Product Overview 11
Quality and Testing
Quality First. Always.
Cutting edge technologies and uncompromising commitment to quality and reliability have made us one of the world's most trusted brands in air conditioning and refrigeration equipment and service.
Development
Operating Tests in Harsh Conditions Harsh environmental conditions of cold regions are simulated for the development of our air conditioners. This is another reason customers in severely cold regions rely on us for comfortable heating.
Combustion Test Products are subjected to a wide range of tests including combustion testing, all to confirm safe operation under a variety of conditions. Combustion testing is done by assuming accidental firing and replicating abnormal conditions that cause breakage of pressure components.
Shock Resistance On the assumption of many different kinds of logistics environments in the world, we perform drop/strength tests, transport vibration tests, and many other product checks to assure that the quality and performance are maintained when the product reaches the user's home.
Explosion-proof chamber
12 Product Overview
Drop/strength testing
Transport vibration testing
Waterproof and Corrosion Test Since the outdoor unit is subject to rain, wind, and corrosive substances, potential problems are checked by tests such as showering the unit for a certain amount of time and increasing protection to enhance the lifespan of the unit.
Operation Noise Test Operation noise tests are performed in an anechoic chamber with an extremely low 10 dB(A) of background noise. This is just one of the ways we ensure our customers enjoy extremely quiet air conditioners with a minimum operation noise of 19 dB(A) (sound pressure level).
Design
Anechoic chamber
Designed to create and maintain a comfortable environment To improve the quality of products, engineers strive to achieve our philosophy of combining comfort and ecology in an effort to continually raise the bar. Therefore, we are working to further improve quality at all stages from development to production.
Production
Each and every unit is checked and double-checked by experienced professionals Every air conditioner goes through a rigorous electrical inspection on the manufacturing line. In final testing, our experienced inspectors listen for even the faintest operation noise to detect any defect.
Product Overview 13
INVERTER Technologies
Our Promise: Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy. Fast, comfortable operation and amazingly low running cost -- that's the Mitsubishi Electric promise.
How Inverters Work
Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner. They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and providing the most comfortable room environment.
Economic Operation
Impressively low operating cost is a key advantage of inverter air conditioners. We've combined advanced inverter technologies with cutting edge electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling efficiency. Better performance and lower energy consumption are the result.
True Comfort
Below is a comparison of air conditioner operation control with and without an inverter.
N o n -Ni novne-ritnevrear ti re rc oani rdci toi on nd ei tri o n eOkrene/pOsOkffernooe/oppOmesfrfratooetopimomenpraeotetrfimaoctnopumreoerfpacrtoeusmresporressor
ChangCehainngroeoimn room tempeteramtupreerature Full poFwulel rpower
InverIntevreratier rcaoinrdciotinodnietironerOkepetpimOkseuppemtrpiems-csuopemnrtetrr-coosoloenomttfrrooftreloemomqfupfteereenrmaqctuypueerenractyure
ChangCehainngroeoimn room tempeteramtupreerature
MinimMuimnimpouwmepr ower consucmonpstiuomn ption
Preset temperature Preset temperature Preset temperature Preset temperature
ON ON OFF OFFON OONFF OFOFN ON
gettingettotoinghotot o hogtettinggetottoincgotoolo cool
ConstCanotnrsotaonmt rtoeommpetreamtuprerature
CompCreosmsporeospseoraotipoenration
Time Time
CompCreosmsporeospseoraotipoenration
Time Time
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the preset room temperature. This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room temperature. This ensures energy-efficient operation and a more comfortable room.
POINT 1 Quick & Powerful
POINT 2 Room Temperature Maintained
Increasing the compressor motor speed by controlling the operation frequency ensures powerful output at start-up, brings the room temperature to the comfort zone faster than units not equipped with an inverter. Hot rooms are cooled and cold rooms are heated faster and more efficiently.
The compressor motor operating frequency and the change of room temperature are monitored to calculate the most efficient waveform to maintain the room temperature in the comfort zone. This eliminates the large temperature swings common with non-inverter systems and guarantees a pleasant, comfortable environment.
Key Technologies
Our Rotary Compressor
Room Temperature Maintained
Our rotary compressors use our original Poki-Poki Motor and Heat Caulking Fixing Method to achieve a compact-high-efficiency unit. They are designed to be used in various residential and commercial applications. In addition, the Divisible Middle Plate production method realizes even more size and weight reductions while increasing capacity and meeting energy efficiency needs.
Our scroll compressors are equipped with an advanced frame compliance mechanism that allows self-adjustment of the position of the orbiting scroll according to pressure load and the accuracy of the fixed scroll position. This minimizes gas leakage in the scroll compression chamber, maintains cooling capacity, and reduces power loss.
14 Product Overview
More Advantages With Our Products
Joint Lap DC Motor Mitsubishi Electric has developed a unique motor, called the Poki-Poki Motor in Japan, manufactured using a joint lapping technique. This innovative motor operates based on a high-density, high-magnetic force, leading to extremely high efficiency and reliability.
Magnetic Flux Vector Sine Wave Drive This drive device is a microprocessor that converts the compressor motor's electrical current waveform from a conventional waveform to a sine wave (180°conductance) to achieve higher efficiency by raising the motor winding utilization ratio and reducing energy loss. reliability.
Reluctance DC Rotary Compressor Powerful neodymium magnets used in the reluctance DC motor rotor produce strong magnetic torque and reluctance torque resulting in more efficient operation.
DC Compressor Motor Rotor
Neodymium magnets
Magnetic torque
+
Reluctance torque
Highly Efficient DC Scroll Compressor Adding a frame compliance mechanism to the DC scroll compressor achieves further efficiency. The mechanism allows movement in the axial direction of the frame supporting the cradle scroll, thereby significantly reducing leakage and friction loss and ensuring high efficiency at all speeds.
Room Temperature Maintained The inverter monitors the varying compressor motor frequency and creates the most efficient waveform for the motor speed. This results in improving operating efficiency at all speed ranges, using less power, and reducing annual electricity costs.
Smooth Wave Pattern
The synthetic resin is molded with the circuit pattern to reduce the inverter size. Using soft PWM control to eliminate the metallic whine associated with conventional inverters achieves quieter operation.
Sine-wave drive soft PWM
PAM (Pulse Amplitude Modulation) PAM is a technology controlling the current waveform to resemble the supply voltage wave resulting in reduced loss and more efficient electricity use. PAM control effectively utilizes 98% of the input power supply.
Without PAM Control
Supply voltage
With PAM Control
Time
Current
Time
Merits of PAM Control
Significant energy savings with remarkable reduction in power loss saves electricity
Limited energy savings Electricity is wasted
Power increased Efficient voltage increase realizes increased power
PAM
Conventional Inverter
Limited power Insufficient power when needed
Power Receiver and Twin LEV Control Mitsubishi Electric developed a power receiver and twin linear expansion valve (LEVs) circuit that optimize compressor performance. This technology ensures ultimate control in response to the operating waveform and outdoor temperature. Tailoring the system to the characteristics of R410A refrigerant improves operational efficiency.
Frame can move in direction
of axis
Fixed scroll
Substantial reduction in leakage and friction loss
Frame Cradle scroll
Leakage loss (minimum)
Thrust gas power (minimum)
Thrust friction loss (minimum)
Secondary back-pressure chamber minimizes thrust friction loss
Primary back-chamber minimizes leakage loss
Heat Caulking Fixing Method A Heat Caulking Fixing Method replaced arc spot welding to secure internal parts in place. This change reduces the distortion of internal components resulting in additional efficiency gains.
Heat exchanger
Compressor
Power receiver
LEV1
Heat exchanger
LEV2
Grooved Piping
Grooved piping
High-performance grooved piping
is used in heat exchangers to Pipe Image
increase the heat exchange area. Cross Sectional View
DC Fan Motor A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor. increase the heat exchange area.
Product Overview 15
Features
for Nv-Series
The WPH Model comes equipped with a 3D i-see Sensor®, an infrared-ray sensor that measures temperatures at different positions throughout the space. While scanning the area from left to right, eight vertically arranged sensor elements analyze the room temperature in three dimensions. Based on temperature readings, the sensor detects the location of people in the room. This technology enables the user to personalize comfort by selecting their preferred airflow setting.
Sensor with eight elements
Indirect Airflow
Direct Airflow
The Indirect Airflow setting diverts airflow away from people within the space.
The Direct Airflow setting blows conditioned air toward people within the space.
Absence Detection
The sensors detect whether there are people in the room. When no one is in the area, the unit automatically switches to Energy Saving Mode.
Sensor measures while moving from the left to right
8 × 94 areas
When the 3D i-see Sensor detects an unoccupied room, the power consumption reduces by ~10% after 10 minutes and further decreases by ~20% after 60 minutes.
Divided into 94
for CKA and PLA Models
Detects Number Of People The 3D i-see Sensor detects the number of people in the room and adjusts the power accordingly. This saves energy in places where the number of people changes frequently. Additionally, when the area is continuously unoccupied, the system switches to an advanced Power Saving Mode. Depending on the setting, it can also stop the operation.
Detects number of people
Detects the Location of Individuals
Detects the Location of Individuals The airflow in the space is entirely customizable. The user can choose Direct Airflow or Indirect Airflow configurations for each of the four air vanes. Once the sensor detects a person within the area, each air vane adjusts automatically to the preferred settings.
8
7
6 4 53 2 1
Highly Accurate Temperature Measurements A total of eight sensors rotate a full 360° in 3-minute intervals. The sensor measures temperature throughout the space, plus the algorithm determines the number of people within the area and their locations.
Detects position and number of people
Detects floor temperature
8 sensors
12 3 4 5
6
7
8
360°
Detection
8 ft. 23 ft.
3 ft.
39ft.
Floor surface *In case of a 8ft. ceiling
16 Product Overview
Determines Occupancy
Room Occupancy Energy Saving Mode The 3D i-see Sensor® detects the number of people in the room. It calculates the actual occupancy rate as a percentage of the maximum number of people. When the occupancy rate is approximately 30%, the system energy savings is equivalent to 2° F during cooling or heating operation. The Energy Saving Mode algorithm controls the room temperature based on space occupancy.
Room Occupancy Energy Save Mode No Occupancy Energy Save Mode
2° F power savings
4° F power savings
No Occupancy Energy Saving Mode When the 3D i-see Sensor detects that no one is in the room, the system switches to a preset powersaving mode. If the area remains unoccupied for more than 60 min, the system energy savings is equivalent to 4° F during cooling or heating operation. This mode reduces energy wasted on heating and cooling unoccupied rooms.
Detects the Location of Individuals
Seasonal Airflow*
When Cooling:
When Heating:
The unit saves energy
Once the room reaches the
while keeping a
temperature setpoint, the
comfortable temperature system switches from heating
by automatically switching mode to fan mode. The fan
between ventilation and
recirculates conditioned air
cooling modes. Once the
throughout the space to
room reaches the desired prevent heated air from being
temperature, the system
wasted by collecting at the
switches from cooling mode ceiling. This feature improves
to swing-fan operation to room comfort by eliminating
extend the amount of time annoying temperature
the space maintains setpoint. differences caused by air
stratification.
Cooling
Heating
*AAR-40MAAU is required for each setting.
No Occupancy Auto Off Mode
Auto-Off
*AAR-40MAAU is required for each setting
No occupancy Auto Off Mode When the room remains unoccupied for a predetermined amount of time, the system automatically turns off. The time duration the system remains off can be configured in 10-minute increments ranging from 60 minutes to 180 minutes.
Direct/Indirect Settings* When set to Indirect Airflow, the vanes direct air horizontally across the ceiling away from individuals eliminating drafts.
*AAR-40MAAU is required for each setting.
Area Temperature Monitor The 3D i-see Sensor monitors the whole room in small sections and directs the airflow to regions within the space as needed. For example, if the system is in cooling mode and the middle of the room is hot, then more airflow is directed toward the problem area to even out the room temperature. This smart feature eliminates unnecessary heating and cooling costs while delivering more uniform temperatures and comfort throughout the room.
Daytime
Warmer area
Nighttime
Cooler area
Cooling Mode
Product Overview 17
Energy-Saving
Econo Cool Mode Econo Cool is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on discharge air temperature. The setpoint can be raised by 4° F without any loss in comfort, achieving an additional 20% energy efficiency.
(Function only available during manual cooling operation.)
Conventional
Econo Cool
Ambient Temperature
95° F
95° F
Set Point
77° F
81° F
Perceived Temperature
86° F
85° F
Econo Cool
Conventional Cooling Mode
Demand Function (Onsite Adjustment) Based on the signal input, energy consumption can be reduced up to 100% of the typical consumption. The demand function can be activated by a commercially available timer or an on/off switch added to the CNDM connector (optional) on the outdoor unit control board.
[Example: P-Series] Limit energy consumption by changing the settings of SW7-1, SW1 and SW2 on the control board of the outdoor unit. The following settings are possible.
SW7-1
SW1
SW2
Energy Consumption
OFF
OFF
100%
ON
OFF
75%
ON
ON
ON
50%
OFF * PUY/PUZ outdoor only
ON
0% (Stop)
Temperature distribution (° F) 58 61 64 68 72 75 79 82
Air Quality
Nano Platinum Filter This filter has a large capture area and incorporates nanometer-sized platinum-ceramic particles that work to kill bacteria and deodorize the circulating air.
Catechin Filter Catechin is a bioflavonoid by-product of green tea with both antiviral and antioxidant qualities. In addition to improving air quality, it prevents the spreading of bacteria and viruses throughout the room, and also has an excellent deodorizing effect.
Air Filter This filter removes dust particles from the air.
Deodorizing Filter The catalyst coating on the honeycomb-structured frame captures small foul-smelling substances in the air, then breaks down the source of the odors with the power of the ozone generated in a plasma electrode unit.
Electrostatic Anti-Allergy Enzyme Filter This filter is charged with static electricity, enabling it to attract and capture dust particles that regular filters cannot capture. This filter can also trap allergens such as bacteria and decompose them using enzymes retained in the filter.
Air Purifying Filter The filter has a large capture area and deodorizes the circulating air.
Fresh-air Intake The direct intake of fresh exterior air enhances indoor air quality.
High-efficiency Filter This high-performance filter has a much finer mesh compared to standard filters, and is capable of capturing minute particulates floating in the air that were not previously caught.
Oil Mist Filter The oil mist filter prevents oil mist from penetrating the inner part of the air conditioner.
Long-life Filter A special process for the entrapment surface improves the filtering effect, making the maintenance cycle longer than that of units equipped with conventional filters.
Filter Check Signal The system monitors the air conditioner operating time, and the user is notified when filter maintenance is necessary.
18 Product Overview
Air Distribution
Double Vane The double vane separates airflow into different directions to supply air across a wide area of the room and also reach people in two separate locations.
Natural Flow Operation Airflow becomes more like a light breeze, and the occupant feels more comfortable.
Indirect/Direct Mode This mode offers finely-tuned operation by locating where an occupant is in the room and sends the air directly or indirectly according to the selected mode.
Powerful Operation The air conditioner will automatically adjust the fan speed and set temperature for 15 minutes. Rapid cooling and heating will make the room comfortable more quickly.
Wide Airflow Especially beneficial for large spaces, helping to ensure that the air is well circulated and reaches every corner of the room. Select the desired airflow pattern and it will distribute air horizontally over a wide-ranging 150° in heating mode and 100° in cooling mode.
Vertical Vane The air outlet fin swings from side to side so that the airflow reaches every part of the room.
High Ceiling Mode In the case of rooms with high ceilings, the outletair volume can be increased to ensure that air is circulated all the way to the floor.
Low Ceiling Mode If the room has a low ceiling, the airflow volume can be reduced for less draft.
Auto Fan Speed Mode The airflow speed mode adjusts the fan speed of the indoor unit automatically according to the present room conditions.
Auto Vane Control Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.
Horizontal Vane The air outlet vane swings up and down so that the airflow is spread evenly throughout the room.
Blue Fin Coating
Blue Fin Heat Exchanger Anti-corrosion treatment applied to the heat exchanger of the outdoor units. This coating prevents the corrosion of the aluminum fins caused by salt in the air, especially in coastal areas. (Corrosion of the heat exchanger will affect the efficiency and performance of the air conditioner.)
Standard HEX coatings: Rated for 240 hours spraying time*
Blue Fin HEX coatings: Rated for 960 hours spraying time*
*Per JRA 9002 Standard Coating is applied on all Nv-Series single-zone outdoor units
Compatibility Outdoor Unit SPH SPF SST SMT SMT 115V SEL SKS (9, 12,15)
SKH (9, 12, 15, 18) PUZ/Y-BS
(sea coast protection models only) MMX/MPH Multi-zone (branch box type)
Blue Fin Coating
· · · · · · · · ·
·
RAensHityin-dAcrlLoouurprbmrhoiiislcniiacuonnmtCoCFCiaotoniaatntiignngg PhosSipRlihecsoiarincHAlLyAuucdirbmrdioicnpCauhhirnlimtocFCmiCaontoaetaitiCnnoggating
Blue Fin HEX
Standard HEX
Product Overview 19
Convenience
Smart Set
Smart Set is a simplified setting function that recalls the preferred (preset)
temperature by pressing a single button on the remote controller. Press
the same button twice in repetition to immediately return to the previous
temperature setting. Using this function contributes to comfortable waste-
free operation, realizing the most suitable air conditioning settings and
saving on power consumption when, for example, leaving the room or
going to bed.
Heating
Heating
70° F
65° F
Smart Set
Auto Changeover The air conditioner automatically switches between heating and cooling modes to maintain the desired temperature.
Low-Temperature Cooling Intelligent fan speed control in the outdoor unit ensures optimum performance even when the outside temperature is low.
Ampere Limit Adjustment Dip switch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs.
*Maximum capacity is lowered with the use of this function
Auto Restart Especially useful at the time of power outages, the unit turns back on automatically when power is restored.
Operation Lock (Outdoor Unit) To accommodate specific-use applications, cooling or heating operation can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service.
Sleep Mode When Sleep Mode is activated using the wireless remote controller, it will switch to the settings described below.
· After 30 minutes, the set temperature will automatically change to the sleep mode set temperature, which the user can set beforehand.
· The fan speed will immediately change to low fan speed.
On/Off Operation Timer Use the remote controller to set the times of turning the air conditioner On/Off.
20 Product Overview
WPH Remote - Closed
FS Remote - Open
Weekly Timer Function Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
Sample Operation Pattern (Winter/Heating mode)
Mon.
Tues.
Wed.
Thurs.
Fri.
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
AM
Automatically changes to high-power operation at wake-up time
AM
AM
OFF
AM
PM
OFF
OFF
OFF
Automatically turned off during work hours
OFF
PM
PM
PM
PM
(during sleeping
hours)
ON 72°F ON 64°F
ON 72°F
ON 72°F
ON 72°F
Automatically turns on, synchronized with arrival at home
ON 72°F
ON 64°F
ON 64°F
ON 64°F
ON 64°F
Automatically lowers temperature at bedtime for energy-saving operation at night
Settings
Pattern Settings: Input up to four settings for each day Settings: ·Start/Stop operation ·Temperature setting The operation mode cannot be set.
Sat. ON 68°F
Sun. ON 68°F
ON 64°F
ON 64°F
Midday is warmer, so the temperature is set lower
ON 72°F
ON 72°F
Automatically raises temperature setting to match time when outside-air temperature is low
ON 64°F
ON 64°F
Easy Set-Up Using Dedicated Buttons The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer. Setting operation patterns is easy and quick.
How to set the Weekly
Timer
PUSH
PUSH
Ready to set
PUSH
PUSH
PUSH
Select the day
Select the period
PUSH
PUSH
How the W
Tim
Com
Complete
Select ON/OFF
Select the time
Set the temperature
Set a Weekly Timer Start by pushing the "SET" button and follow the instructions to set the desired patterns. Once all of the desired patterns are input, point the top end of the remote controller at the indoor unit and push the "SET" button one more time. (Push the "SET" button only after inputting all of the desired patterns into the remote controller memory. Pushing the "CANCEL" button will end the set-up process without sending the operation patterns to the indoor unit). It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit. Please continue to point the remote controller at the indoor unit until all data has been sent.
System Control
M-NET Connection Units can be connected to MELANS system controllers (M-NET controllers) such as the TE-200A.
kumo cloud® Wireless Interface Along with your smart phone or tablet device, you can manage your system in multiple venues, such as home, work and vacation locations. You can control functions like turning on/off, fan speed, and vane direction.
Mx Connection Connection to the MX multi-split outdoor unit is possible.
System Group Control The same remote controller is capable of controlling the operational status of up to 16 refrigerant systems.
Product Overview 2121
Anytime, Anywhere Control
kumo cloud gives you the ability to control your home's comfort effortlessly. Whether you're out for the day or out for the month, looking to cool down or warm up, kumo cloud gives you control from any smart device or web browser.
Wireless Interface 2
Indoor Unit
Manage Your Comfort From Anywhere with kumo cloud
kumo cloud app
· Compatible with Nv-Series and P-Series · kumo cloud allows for a American Standard®/Mitsubishi Electric indoor unit to be controlled remotely
or locally with the app · For product information, go to kumocloud.com · Ability to group indoor units and organize groups into sites · Batch command indoor units · Ability to program events and scheduling into the unit itself · Available in Fahrenheit or Celsius · Easy to connect the device to home router using the kumo cloud app · Each indoor unit must be equipped with a Wireless Interface (PAC-USWHS002-WF-2) installed by a
licensed contractor · Secure boot to prevent unauthorized reprogramming of the Wireless Interface · Intuitive initial settings feature for Nv- & P-Series equipment · Compatible with Amazon Alexa and Google Home
Program and Schedules kumo cloud setup walks through a simple five-step process to easily schedule modes, program set points, and select fan speeds for all zones or one at a time.
Easily Zoned The kumo cloud app discovers active Wireless Interface devices. Once located, each zone can be named and organized into groups.
Check Filter Status You never have to manually check a filter again. kumo cloud can tell you the status of any filter in your system at any time.
22 Product Overview
kumo touchTM
Simple Wall-mounted design controllers can be installed anywhere with large, back lit, easy to read display. Both the controller and receiver is enabled with RedLINK reliability.
Receiver
Indoor Unit
Optional Wireless Interface
(Required for kumo cloud®)
MHK2 Controller
MRCH2 kumo touch Controller Specifications
· Touch panel, Back lit, easy-to-read display
· Used RedLINKTM 3.0 wireless technology
- Not compatible with MHK1, MOS1, and MCCH1 RedLINK 2.0 wireless technology environment
· User functions allow user to set:
- On/Off - Operation modes cool, heat, drying, fan - Set temperature (separate dual set points for heat and cool) - Fan speed setting - Airflow direction
· Set temperature range limits (dependent on the system
connected):
- Cooling from 50° to 99° F - Heating from 40° to 90° F - Auto from 50° to 90° F with dual temperature setting
· MHK2 Scheduling options:
- No Schedule - MO-SU = Every day the same - MO-FR, SA, SU = 5-1-1 schedule - MO-FR, SA-SU = 5-2 schedule - Each Day = Every day individual - Allow kumo cloud to be schedule holder
· Hold function
· Temporary or Permanent schedule override
· Lockout:
- On, Off, Mode, Fan Speed, Set point, Vane Direction
· Day/Time display with a 12 or 24-hour clock
· Supports both Fahrenheit and Celsius
· RedLINKTM Wireless Connection Status
· Filter sign display
· Diagnostics: Displays and records error codes
· Adjustable auto mode dead band
· Space temperature offset adjustment
· Space humidity offset adjustment
· Hide (on screen only)
- Indoor temperature - Indoor humidity
· Temperature Sensing Source
MHK2 Specifications
- Indoor Unit - RedLINK Wireless Indoor Air
Sensor (IAS) - Average of MHK2 and
RedLINK Wireless Indoor Air Sensor (IAS)
· Indoor Humidity Source
- MHK2
MHK2
- RedLINK Wireless Indoor
Air Sensor (IAS)
- Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS)
· Improved indoor unit function code list
- Indoor unit type - Expanded to 28 indoor unit codes
· Reset to factory default
· Uses two "AA" alkaline batteries (included)
· Dimensions: 4-5/64" x 4-5/64" x 1-1/16" (104 x 104 x 27 mm)
· Operating Ambient Temperature: 32° to 120° F (0° to 48.9° C)
· Operating Relative Humidity: 5% to 90%
MIFH2 Wireless Receiver Specifications · Included in MHK2 Kit · Mounts next to or near indoor units to allow MRCH2
Remote Controller operation
· Connects to indoor unit control board with MRC2 Cable · Dimensions: 3-3/32" H x 1-3/4" W x 39/64" D (74.8 x 44.4 x 15.4 mm) · Operating Ambient Temperature: -40° to 165° F (-40° to 73.9° C) · Operating Relative Humidity: 5% to 95%
MRC2 Cable
· Included in MHK2 Kit in the MIFH2 box
· Connects MIFH2 Wireless Receiver to the CN105 connector
on indoor unit control board
· Length: 39-23/64" (1 m)
Apple and the App Store are registered trademarks of Apple, Inc. Amazon, Alexa, Fire and all related logos are trademarks of Amazon.com, Inc. or its affiliates. Google play is
a registered trademark of Google, Inc.
Product Overview 23
Wired Controllers
Simple MA Remote Controller
PAC-YT53CRAU-J
· Controls group operation for up to 16 indoor units in a single group
· Supports Fahrenheit and Celsius · User defined functions: · On/Off · Operation modes: Heat/Cool/Auto/Dry · Fan speed setting · Airflow direction · Set temperature range: 40° F to 95° F
depending on operation mode and indoor unit connected · Set temperature range limit for cool and heat modes
· LOSSNAY®: Simple MA for interlocked system can set high/low/stop on LOSSNAY
· Room temperature can be sensed either at indoor unit (default) or at the remote controller
· Dimensions: 2-3/4" W x 9/16" D x 4-3/4" H
· Requires MAC-334IF-E for use with NvSeries products
Deluxe MA Remote Controller
AAR-40MAAU
User defined functions: · On/Off · Operation modes: Heat/Cool/Auto/Dry · Room temperature setting &
Temperature range restriction · Manual vane angle (P-Series cassette
indoor units) · Smooth maintenance (P-Series only) · Auto-off timer & Weekly timer · Setting screen for 3D i-see Sensor®
· Draft reduction mode
· Daylight Saving Time (DST)
· Dimensions: 4-3/4"W x 3/4"D x 4-3/4"H
· Requires MAC-334IF-E for use with Nv-Series ductless products
· Room temperature displays room temperature sensed either at the indoor unit (default) or at the controller
Deluxe MA Remote Controller
PAR-CT01MAU-SB
· User-friendly, customizable full color touch panel display · Ability to add a custom logo on the display · Large icons with 180 color patterns · Daily and weekly timers · Password protected · Requires MAC-334IF-E for use with Nv-Series products · The MELRemo app and Bluetooth® Low Energy (BLE) technology supports
communication with smartphones or tablets in multiple languages
24 Product Overview
Interface Devices
Thermostat Interface
PAC-US444CN-1
· Control your Zoned Comfort Solution using a third-party 24VAC transformer
· Wires back to the indoor unit using CN105 to replace the return air temperature sensor
· Maximum wiring length: 39" (12 m)
· Dimensions: 3.17 in (w) x 3.96 in (h) x 0.93in (d) (80.6 x 100.6 x 23.7 mm)
· Exterior shell made of ABS resin
· Environment Conditions -- operating temperature range: Installation manual states that the temperature should be between 32° F and 104° F (0° C to 40° C)
BACnet® Interface
· Allows for third-party home automation/building management system to control indoor unit
· One interface required per indoor unit
· Compatible with remote controllers
· Dimensions: 3.74" x 2" x 0.75"
· Cable length: 37"
· Allows for third-party home automation/ building management system to control indoor unit
PAC-UKPRC001-CN-1
USNAP Interface
· Allows indoor units to participate in demand response events
· Works with CTA 2045 DC Form Factor Universal Communication Modules (UCMs)
· 3 LEDs to display device status
· Communication with UCM · Communication to indoor unit · Demand Response Events · System Reset
PAC-WHS01UP-E
MAC-334IF-E System Control Interface
· Allows Nv-Series indoor units to communicate with the CITY MULTI® Controls Network via M-Net
· Provides an input to allow remote On/
· Allows Nv-Series indoor units to connect to a MA controller
· Power: 12V DC (supplied from indoor unit)
· Off control of indoor unit
MAC-334IF-E
· Allows Nv-Series indoor units to connect to MHK2 Wall-mounted Wireless Controller when using other MAC-334IF-E functions
Product Overview 25
Features
Category
Icon
Indoor Unit
NAXWPH(06/09/12/15/18)A112A*
Outdoor Unit
Nv-Series MSZ-EF09/12/15/18NA(W)(B)(S)
NAXWST(06/09/12/15/18)A112A*
Combination NAXSPH MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone NAXSST MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone
i-see Sensor
Energy Saving
Radiant Temperature Control (3D i-see Sensor®) AREA Temperature Monitor
Econo Cool
Nano Platinum Filter Catechin Filter
······ ······ ················· ·················
Air Quality
Air Cleaning Filter
Deodorizing Filter Electrostatic Anti-Allergy Enzyme Filter Anti-Allergy Enzyme Filter
······ · · · · · · · · · · · 24 24 24 24 24 24
06-18 06-18 06-18 06-18 06-18 06-18
Functions
Air Purifying Filter
Double Vane
Horizontal Vane
Vertical Vane
Air Distribution
Natural Flow Operation
Wide Airflow
Indirect/Direct Airflow
Powerful Operation
Smart Set
Auto Restart
Low Temperature Cooling
Convenience Sleep Mode
12H On/Off Operation Timer
24H On/Off Operation Timer
Weekly Timer
Blue Fin Maintenance
Dual Barrier Coating
······
·················
······
18/24 18/24 18/24 18/24 18/24 18/24
······
24 24 24 24 24 24
······
······
24 24 24 24 24 24
· · · · · · · · · · · 06-18 06-18 06-15 06-18 06-18 06-18
·················
·················
·················
···········
·
· *1 · *1 ·
· *1 · *1 · ·
· *1 · *1 ·
·
*1 Branch box units only: NAXMMX48A182**, NAXMMX60A182**, NAXMPH36A142**, NAXMPH42A152**, and NAXMMX48A182** *2 Sea coast protection models only (-BS)
26 Product Overview
NAXSST NAXSMT NAYSST NAYSST NAXSEL NAXSMT
115V NAXSPF MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone NAXSKS MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone NAXSKS MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone
NAXWST (30/36) A112A*
NAXWMT (09/12/15/
18/24) A112A*
NAYWST (09/12/15/
18/24) A112A*
NAYWST (30/36) A112A*
NAXWEL (09/12/18/24) A112A*(09/12/18/24)
A112A*
NAXWMT 115V(09/12)
A111A*
Nv-Series
NAXFKS (09/12/15/18)
A112A*
NAXUKS (09/15/18) A112A*
NAXAMT (12/18/24/30/36)
A112A*
·
·
·
·
·
·
·
·
·
·
24
·
Opt
09-18
·
·
·
·
·
·
·
18/24
·
·
24
·
·
24
·
18/24
06-18
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Opt: Separate parts must be purchased.
· ············ · ······
·· · · · ·
Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
······ · ············
······
······ ············ · · · · · · ··· · · · ··· · · · · · · · · · ··· · · · ··· · · · · ············
· ············
············
··
· *1 · *1 · ·
· *1 · *1 · ·
· *1 · *1 ·
Product Overview 27
Combination NAXSKS MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone NAXSKS MX 2 zone MX 3 zone MX 4 zone MX 5 zone MX 8 zone PUZ-A PUY-A PUZ-HA MX 3 Zone MX 4 Zone MX 5 Zone MX 8 Zone
Features
Category Icon
Nv-Series
Indoor unit
NAXCKS(09/12/15/18)A112A*
NAXDKS(09/12/15/18)A112A*
Outdoor Unit
P-Series PLA-A12/18/24/30/36/42EA7
i-see Sensor
Energy Saving
Radiant Temperature Control (3D i-see Sensor®) AREA Temperature Monitor
ENERGY STAR©
Demand Function (PAR-33MAA)
Fresh-air Intake
······
·······
·······
12/18/ 24/36
12/18/ 24/36
30/36
···
·······
Air Quality
High-efficiency Filter Long-life Filter
Filter Check Signal
······ ······
······· ·······
Vertical Swing
······
·······
Functions
Horizontal Swing Air Distribution High Ceiling Mode
Low Ceiling Mode
······
··· ···
Auto Fan Speed Mode · · · · · · · · · · · · · · ·
Auto Restart
············ · · ·
Low Temperature Cooling
Convenience
12H On/Off Operation Timer
24H On/Off Operation Timer
············ · · ·
Weekly Timer
Self-Diagnostic Function
Maintenance
Failure Recall Function
············ · · · ············ · · ·
Blue Fin
·
· *1 · *1 · ·
· *1 · *1 · · *2 · *2
*1 Branch box units only: NAXMMX48A182**, NAXMMX60A182**, NAXMPH36A142**, NAXMPH42A152**, and NAXMMX48A182** *2 Sea coast protection models only (-BS)
···· ···· ···· ···· ····
···· ····
· *1 · *1 ·
28 Product Overview
PKA-A12/18HA7 PKA-A24/30/36KA7
PCA-A24/30/36/42KA7
P-Series PEAD-A12/18/24/30/36/42AA7
PVA-A12/18/24/ 30/36/42AA7
PUZ-A PUY-A PUZ-HA PUZ-A PUY-A PUZ-HA MX 3 Zone MX 4 Zone MX 5 Zone PUZ-A PUY-A PUZ-HA MX 2 Zone MX 3 Zone MX 4 Zone MX 5 Zone MX 8 Zone PUZ-A PUY-A PUZ-HA
Opt Opt Opt Opt Opt Opt
12 12 30/36
12 12 30/36
······
···
······
···
Opt Opt Opt Opt Opt Opt
·············· Opt Opt Opt · · · · · · · · · · · · · · ·········
···················· ···················· ····················
····················
····················
· *2 · *2
· *2 · *2
· *1 · *1 · *2 · *2
· *1 · *1 · · *2 · *2
Opt: Separate parts must be purchased.
Product Overview 29
Nv-Series
Whether for a cold spot or hot spot or the entire home, our systems are versatile and perfectly suited for any cooling or heating occasion.
Nv-Series Product Lineup
Heat Pumps
A multiple model lineup to choose from, each with various outstanding features. In addition to inverter-equipped Wall-mounted models, floor-standing and Multi-position air handlers can be selected. Choose the best style to match usage needs.
Wall-mounted Units
WPH Model
MSZ-EF Model
WST Model
WST Model EZ FIT® Ceiling Cassette Unit
WMT Model WMT 115V Model
Multi-position Air Handler
WEL Model Floor-mounted Unit
UKS Model Ceiling Cassette Units
AMT Model Horizontal-ducted Units
FKS Model
CKS Model
DKS Model
PEAD Model
Cooling Only
For applications with needs for only cooling, there are cooling-only models to choose from. Wall-mounted Units
WST Models
Nv-Series 31
WPH Model
Deluxe Wall-mounted Indoor Unit
Dual Barrier Coating
The patented Mitsubishi Electric Dual Barrier Coating prevents dust and dirt from accumulating on the inner surface of the heat pump, keeping your heat pump clean year-round.
Blended fluorine particles prevent hydrophilic dirt penetration, and hydrophilic particles prevent hydrophobic dirt from getting into the heat pump. As a result, the patented Dual Barrier Coating keeps the heat exchanger, vanes/air ducts and blower wheel clean.
A clean heat exchanger preserves high-efficiency operation and optimal heat transfer. Also eliminated is additional motor power input required to deliver the proper airflow through a dirty blower wheel and heat exchanger contributing to operational efficiency. Over time, the end result is 30% better airflow and 18% less energy consumption than a system without Dual Barrier Coating.
Heat Exchanger
Comparison of Dirt on Heat Exchanger, Blower Wheel and Air Duct
Actual images of accelerated 10 year test
Heat Exchanger
Blower Wheel Vanes and Ducts
No Dual Barrier Coating 32 Nv-Series
Blower Wheel Air Duct
Dual Barrier Coating Used
The WPH Model comes equipped with a 3D i-see Sensor®, an infrared-ray sensor that measures temperatures at different positions throughout the space. While scanning the area from left to right, eight vertically arranged sensor elements analyze the room temperature in three dimensions. Based on temperature readings, the sensor detects the location of people in the room. This technology enables the user to personalize comfort by selecting their preferred airflow setting.
Sensor with eight elements
Indirect Airflow
The Indirect Airflow setting diverts airflow away from people within the space.
Direct Airflow
The Direct Airflow setting blows conditioned air toward people within the space.
Absence Detection
The sensors detect whether there are people in the room. When no one is in the area, the unit automatically switches to Energy Saving Mode.
Sensor measures while moving from the left to right
8 × 94 areas
When the 3D i-see Sensor detects an unoccupied room, the power consumption reduces by ~10% after 10 minutes and further decreases by ~20% after 60 minutes.
Natural Flow
Divided into 94
The most critical aspect of comfortable airflow is that it feels natural. The Natural Flow feature is accomplished by alternately oscillating the two vanes to simulate a light breeze.
Natural Flow (in Cooling)
104
68
Gentle airflow that avoids overcooling
Direct Airflow (in Cooling)
104
Double Vane
Our double vane separates the airflow in the left and right directions to deliver airflow not only across a wide area of the room but also simultaneously to two people in different locations.
68
Legs become too cold
Base Data for Natural Flow Kirigamine Highland
Measuring Wind Data
Kirigamine Highland is one of the most famous sightseeing spots in Japan. A large number of people visit to experience its pleasant breezes and comfortable weather. We attempted to recreate the feeling of the Kirigamine Highland's natural airflow. Engineers collected data at the site and were able to imitate the waveforms.
Analysis of natural wind
Wind speed [cm/s] 140
120
100
80
60
40
20
0 0 20 40 60 80 100 120 Time [s]
Wind of Kirigamine
Natural Flow(WPH Model)
Nv-Series 33
Deluxe Hand-Held Wireless Controller with Advanced Features
· Backlit screen · Text used for HEAT, COOL, AUTO
Nano·PPloawteinrfulmMoFdieltfeurnsction allows the system to
temporarily run at a lower or higher temperature Tinhcios rfiploterar twheaistsnhaaanlanormgineectsreuerra-fssaiezcdeedafarenasapneded to quickly bring the platinum-rcoeroammitcopyaortuicrleosptthimatawl ocorkmtfoort level breakdo·wWn ibdaectVearinaeansedttdienogdporriozveidthees a wider horizontal air circulatingdaisitr.ribution on select models
Triple-action Filtration
· Indirect or Direct Airflow for personalized comfort
· Wide Vane · L-Vane · R-Vane · Powerful · Indirect/Direct · Natural Flow
Air, like water, is something we use every day unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans. Healthy air is achieved with three filters: the Nano Platinum filter, the Deodorizing filter, and the Electrostatic anti-allergy enzyme filter.
Nano Platinum Filters
This filter has a large surface area and incorporates nanometer-sized platinum-ceramic particles that work to breakdown bacteria and deodorize the
Deodorizing Ficilrtcuelarting air.
This filter removes chemical substances such as ammonia, methyl mercaptan, trimethylamine and hydrogen sulphide at the nano-level (1/1,000,000 of a millimeter).
Lorem ipsum
Electrostatic Anti-Allergy Enzyme Filter Deodorizing Filter
This filter removes chemical substances such as
This filter is charged wamitmhonsitaa, tmicetehylel mcterriccaipttya,n, trimethylamine
enabling it to attractaannddhycdaropgteunrseulpdhuidset at the nano-level particles that regular(1fi/1lt,0e0r0s,0c0a0nonf aomt icllaimpettuerr)e. .
Also, it can trap allergens and bacteria and
neutralizes them using enzymes retained
in the filter.
Electrostatic Anti-Allergy
Enzyme Filter
This filter is charged with static electricity, enabling it to attract and capture dust particles that regular filters cannot capture. Also, it can trap allergens and bacteria and neutralizes them using enzymes retained in the filter.
Quiet Operation
Human hearing limits (Extremely quiet)
Sound of rustling leaves
Library interior
The indoor unit noise level is as low as 20dB(A) for WPH06/09 models, offering a peaceful inside environment.
34 Nv-Series
10dB(A) Human hearing limits
Sound of
20dB(A) (Extremely quiet) rustling leaves
Only
(for WPH06/09 models)
10dB(A)
Only 20dB(A)
(for FS06/09 models)
40dB(A)
Library interior
40dB(A)
Quiet passenger car interior (40km/h)
Subway car interior
60dB(A) Quiet passenger car interior (40km/h)
Subway car 80dB(A)
interior
60dB(A)
80dB(A)
H2i plusTM Hyper-Heating Performance
H2i plusTM hyper-heating heat pump technology is leading technology in the industry. The H2i plus outdoor units produce up to 100% heating capacity down to -5° F.
Heating Capacity
Maximum Heating Capacity at 5°F (-15°C)
SP*06
SP*09
SP*12
SP*15
SP*18
10,500BTU/H 11,590BTU/H 14,690BTU/H 19,360BTU/H 23,000BTU/H
COP at 5°F (-15°C)
2.46
2.41
2.42
2.17
2.15
Maximum Heating Capacity at -5°F (-20.5°C)
8,700BTU/H 9,600BTU/H 12,300BTU/H 16,000BTU/H 19,000BTU/H
COP at -5°F (-20.5°C)
2.26
2.20
2.24
2.01
2.00
Industry Leading Performance
OOppeerraattioionngguurraarraanntteeeeddaattmmininuuss-1-133°°F,F, 110000%%hheeaattininggccaappaaccttiyiyaatt-5-5°°FF
% Heating Capacity HHeeaattiinngg CCaappaacciittyy ((%%))
Heating Capacity At Low Temperatures
120
100
HHeeaatitningg
100
ooppeeraratitoionn
80
ddoowwnntoto --1133°F°F
110000%% hheeaatitningg ccaappaaccitiyty aasslolowwaass
55°F°F
60 1010%0%
40
20
H2i plusTM H2i Standard Heat Pump
0 -13 -1-31-o35oFF
0-4-o4oFF 5
51o50oFF 17
25 191o9oF3F0
35 323o24oF0F 47
OOuOtudutodtodorooTore-rma-aiprireTreTaemtmuprpeeerDaraetugturreerees °FWB
BBaasseeHHeeaatteerreeqquuipipppeeddaassssttaannddaardrd**
HTeThaheteibnbagasesCeahhpeeaaactietteryrrerestsrtircictstslolowweerereddccaappaaccitiytyaannddooppeeraratitoionnshshuutdtdoowwnnss ccaauuseseddbbyyththeeddraraininwwaateterrfrfereeezziningg. .TThhisisfefeaatutureresusuppppoortrstsstsatabblele
ooppeeraratitoionnininloloww-t-etemmppeeraratFutSur0er6eeennvviriorFoSnn0m9meenntst.s.FS12
FS15
FS18
Maximum Heating Capacity at 5°F (-15^)
10,500Btu 11,590Btu 14,690Btu 19,360Btu 23,000Btu
FFrroozzeenn
DDrraaininddooeess
COP at 5°F (-15^)
dd2r.ra4a6inin 2.41
2.42
2.1n7noottffrere2e.e1zz5ee
Maximum Heating Capacity at 8,700Btu 9,600Btu 12,300Btu 16,000Btu 19,000Btu -5°F (-20.5^)
COP at -5°F (-20.5^)
2.26
2.20
2.24
2.01
2.00
WWitihthoouut tBBaaseseHHeeaateter r
WWitihthBBaaseseHHeeaateter r
33.1 13.5
MMUUZZ-F-FHH SStatannddaardrdHHeeaat tPPuummpp
30.5 13.5
26.1 12.5
*Standa*r*dSStftaaonnrddMaarrUddZfof-orFrSNxNAxXTNSXPASBHPmBmomdoeodlsdelesls OptionOOaplptftioioornnaMal lfUofZor -NrFANSXxTSxXPNSHPAmHmomdoeodlsdelesls
SEER
HSPF
22.0 12.5
21.0 12.5
SP*06
SP*09
SP*12
SP*15
SP*18
All WPH/SP* single-zone systems are ENERGY STAR® certified.
Nv-Series 35
WPH Model Indoor Unit
Outdoor Unit
Remote Controller
NAXWPH(06/09/12/15/18)A112A*
NAXSPB(06/09/12)A112A*
NAXSPB(15/18)A112A*
HUMAN
Heat Caulking Fixing Method
Blue Fin
Optional
Nano Platinum
Deodorizing Filter
EAlenctit-raollsetragtiyc
Double Vane
HORIZONTAL
VERTICAL
Natural Flow
POWERFUL MODE
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Indoor Unit
NAXWPH06B112AA
NAXWPH09B112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSPH06B112AA
6,000 1,7009,000
315 0.2 0.960 8,700 1,60014,000 545 5,900 12,840 10,500 8,700 33.1 19.05 13.5 4.68 Yes
137167221304381
117143190261328
140167225325437
2023293640
2024293942
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 82 [37] 1141/1183 47 49 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
NAXSPH09B112AA
9,000 1,70012,000
560 0.6 0.920 9,600 1,60018,000 620 5,900 14,170 11,590 9,600 30.5 16.05 13.5 4.54 Yes
137167221304381
117143190261328
140167225325437
2023293640
2024293942
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 82 [37] 1141/1183 48 49 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
NAXWPH12B112AA
NAXSPH12B112AA 12,000
2,50013,600 870 1.9 0.830
12,300 3,70021,000
850 8,400 17,410 14,690 12,300 26.1 13.8 12.5 4.24 Yes
137167221304424
117143190261364
155226282367454
2124293644
2128323843
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 83 [37.5] 1215/1201 49 51 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
NAXWPH15B112AA
NAXSPH15B112AA 14,000
6,45019,000 1,000 4.0 0.700 16,000
5,15024,000 1,155 10,000 22,730 19,360 16,000 22.2 14.0 12.5 4.06 Yes
225262304355437
194225261305376
201272350410514
2731353944
2531374046
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 18.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 117 [53] 1801/1949 51 55 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115
-13 to 75
NAXWPH18B112AA
NAXSPH18B112AA 17,200
6,45021,000 1,375 4.8 0.690 19,000
5,15030,000 1,610 12,800 27,000 23,000 19,000 21.0 12.5 12.5 3.46 Yes
225262304355437
194225261305376
201272350410514
2731353944
2531374046
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 18.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 118 [53.5] 1801/1949 52 55 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115
-13 to 75
36 Nv-Series
WPH Model Indoor Unit
Outdoor Unit
Remote Controller
NAXWPH(06/09/12/15/18)A112A*
NAXSPH(06/09/12)A112A*
NAXSPH(15/18)A112A*
HUMAN
Heat Caulking Fixing Method
Blue Fin
Optional
Nano Platinum
Deodorizing Filter
EAlenctit-raollsetragtiyc
Double Vane
HORIZONTAL
VERTICAL
Natural Flow
POWERFUL MODE
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Indoor Unit
NAXWPH06B112AA
NAXWPH09B112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSPB06B112AA
6,000 1,7009,000
315 0.2 0.960 8,700 1,60014,000 545 5,900 12,840 10,500 8,700 33.1 19.05 12.5 4.68 Yes
137167221304381
117143190261328
140167225325437
2023293640
2024293942
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 83 [37.5] 1141/1183 47 49 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
NAXSPB09B112AA
9,000 1,70012,000
560 0.6 0.920 9,600 1,60018,000 620 5,900 14,170 11,590 9,600 30.5 16.05 12.5 4.54 Yes
137167221304381
117143190261328
140167225325437
2023293640
2024293942
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 83 [37.5] 1141/1183 48 49 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
NAXWPH12B112AA
NAXSPB12B112AA 12,000
2,50013,600 870 1.9 0.830
12,300 3,70021,000
850 8,400 17,410 14,690 12,300 26.1 13.8 12.0 4.24 Yes
137167221304424
117143190261364
155226282367454
2124293644
2128323843
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 84 [38] 1215/1201 49 51 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115
-13 to 75
NAXWPH15B112AA
NAXSPB15B112AA 14,000
6,45019,000 1,000 4.0 0.700 16,000
5,15024,000 1,155 10,000 22,730 19,360 16,000 22.2 14.0 12.0 4.06 Yes
225262304355437
194225261305376
201272350410514
2731353944
2531374046
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 18.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 118 [53.5] 1801/1949 51 55 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115
-13 to 75
NAXWPH18B112AA
NAXSPB18B112AA 17,200
6,45021,000 1,375 4.8 0.690 19,000
5,15030,000 1,610 12,800 27,000 23,000 19,000 21.0 12.5 12.0 3.46 Yes
225262304355437
194225261305376
201272350410514
2731353944
2531374046
-- -- 12 (+11/16) [305 (+17)] 36-7/16 [925] 9-3/16 [234] 29 [13.5] 18.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 118 [53.5] 1801/1949 52 55 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115
-13 to 75
Nv-Series 37
MSZ-EF Model
Designer Series Wall-mounted Indoor Unit
A Stylish Lineup Matches Any Decor
The stylish Wall-mounted indoor units have eloquent edges, expressing sophistication and quality.The EF Models come in three color options: matte silver, glossy black, or glossy white.
Quiet Operation
Our advanced Quiet Mode fan speed setting provides super-quiet operation as low as 21dB(A) for EF09/12 models.
Human hearing limits
(Extremely quiet)
Sound of rustling leaves
Sound Level
Library interior
Quiet passenger car interior (25mph)
Subway car interior
10dB(A)
21 Only dB(A)
(for EF09/12 models)
40dB(A) 60dB(A)
80dB(A)
Superior Design Concept
The EF Model boosts a modern design coupled with advanced technology providing low power consumption, quiet operation, and powerful performance makes these units a smart selection. They maintain their sleek design during operation as the air vane opens and closes, providing the space with comfort.
Closed
Open
Most MSZ-EF systems are ENERGY STAR® certified.
38 Nv-Series
MSZ-EF Model
Indoor Unit MSZ-EF09/12/15/18NAB*
MSZ-EF09/12/15/18NAS
MSZ-EF09/12/15/18NAW
Remote Controller
Color Options Available: Matte Silver, Glossy Black, or Glossy White
For MX Connection Only* Soft-dry Cloth is enclosed with Black models
Nano Platinum
EAlenctit-raollsetragtiyc
Optional
Optional
USNAP
Optional
Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Optional
T-STAT
Optional
Indoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
MSZ-EF09NA(B/S/W)
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
141162222293371
121140191252319
141162219314420
2123293642
2124293745
-- -- 11-3/4 [299] 34-13/16 [884] 7-11/16 [195] 26 [11.8] -- -- -- -- -- -- -- -- -- -- -- 5/8 [15.88] -- -- -- -- -- --
--
MSZ-EF12NA(B/S/W)
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
141162222293371
121140191252319
141162219314448
2124293642
2124303846
-- -- 11-3/4 [299] 34-13/16 [884] 7-11/16 [195] 26 [11.8] -- -- -- -- -- -- -- -- -- -- -- 5/8 [15.88] -- -- -- -- -- --
--
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
MSZ-EF15NA(B/S/W)
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
205233272314364
176200234270313
194222275350448
2831353942
2830354148
-- -- 11-3/4 [299] 34-13/16 [884] 7-11/16 [195] 26 [11.8] -- -- -- -- -- -- -- -- -- -- -- 5/8 [15.88] -- -- -- -- -- --
--
MSZ-EF18NA(B/S/W)
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
205240279328388
176206240282334
226258318392466
3033364043
3033374349
-- -- 11-3/4 [299] 34-13/16 [884] 7-11/16 [195] 26 [11.8] -- -- -- -- -- -- -- -- -- -- -- 5/8 [15.88] -- -- -- -- -- --
--
Nv-Series 39
NA(X/Y)WST Model
Standard Wall-mounted Indoor Unit
24.6 12.8
23.1 12.5
21.6 11.7
20.5 11.2
SEER 20.5
HSPF
10.0
WST09
WST12
WST15
WST18
WST24
Large Range of Capacities
The NA(X/Y)WST Wall-mounted indoor units offer our highest design flexibility. Combinations include single-zone (cooling only or heat pump) and multi-zone (heat pump or hyper-heating heat pump) systems. A large selection of sizes ranges from 6,000 to 36,000 BTU/H.
NAXWST(06/09/12/15)A112A* NAYWST(09/12/15)A112A*
NA(X/Y)WST18A112A*
NA(X/Y)WST24A112A*
NA(X/Y)WST(30/36)A112A*
Compact Design
Slim and compact indoor units provide enhanced, industry-leading performance for cooling and heating.
11- 5 /8"
31-7/16"
9 - 1 / 8"
All NA(X/Y)WST single-zone systems are ENERGY STAR® certified.
40 Nv-Series
Quiet Operation
Human
hearing limits
The indoor unit noise level is as low as 19dB(A) (Extremely
for WST09/12 models, offering a peaceful inside quiet)
environment.
Sound of rustling leaves
10dB(A)
19 Only dB(A) (for WST06/09/12 models)
Sound Level
Library interior
Quiet passenger car interior (25mph)
Subway car interior
40dB(A) 60dB(A)
80dB(A)
Powerful Operation (WST24, WST30/36) Fan speed: Exclusive speed for POWERFUL mode.
Horizontal Vane: Set position, or downward airflow
Depending on the capacity, the unit will automatically
position during AUTO setting.
adjust the fan speed and set temperature for 15 minutes. Rapid cooling and heating will make the Fraon sopemed: Exclusive speed for POWERFUL mode.
POWERFUL
comfortable quickly.
Horizontal Vane: Set position, or downward airflow position during AUTO setting.
POWERFUL
Nano Platinum Filter (NAXWST06, NA(X/Y)WST09/12/15/18/24)
The Nano Platinum Filter generates stable antibacterial and deodorizing effects. The three-dimensional surface enlarges the filter capture area and increases dust collection performance compared to conventional filters.
It is okay to wash the filter with water (air cleaning effect is maintained)
3D surface (Waved surface)
Smart Set (NAXWST06, NA(X/Y)WST09/12/15/18/24)
Smart Set is a simplified function that recalls the preferred (preset) temperature by pressing a single button on the remote controller. Press the same button twice to return to the previous temperature setting.
70°F
Heating
65°F
Heating
Nv-Series 41
NA(X/Y)WST Model
Indoor Unit
WST18 NAXWST(06/09/12/15)A112A* NAYWST(09/12/15)A112A*
Outdoor Unit
Remote Controller
NAXWST18A112A* NAYWST18A112A*
NAXSST(09/12/15)A112A* NAYSST(09/12/15)A112A*
NAXSST18A112A* NAYSST18A112A*
Blue Nano Fin Platinum
Smart Set
GWLS1T818
Optional
T-STAT
Optional
MSZ-GL06-18
Heat Caulking Fixing Method
Indoor Unit
NAYWST09A112AA
NAYWST12A112AA
NAYWST15A112AA
Outdoor Unit
Capacity
Rated 1
BTU/H
Capacity Range
Min-Max BTU/H
Cooling
Power Input
Rated 1
W
Moisture Removal
Pints/h
Sensible Heat Factor
Capacity at 47ºF
Rated
BTU/H
Capacity Range
Min-Max BTU/H
Power Input at 47ºF
Rated
W
Heating
Capacity at 17ºF
Rated Max
BTU/H BTU/H
Capacity at 5ºF
Max
BTU/H
Capacity at -5ºF
Max
BTU/H
SEER
EER
Efficiency
HSPF
COP
ENERGY STAR® Certified
Indoor Unit
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi)
Wet
Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi)
Dry
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Cooling
Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Heating
CFM CFM CFM dB(A) dB(A)
External Static Pressure
In. W.G.
Condensate Lift Mechanism
Max Distance In. [mm]
H
In. [mm]
Dimensions
W
In. [mm]
D
In. [mm]
Weight
lbs [kg]
MCA
A
MOCP
A
H
In. [mm]
Dimensions
W
In. [mm]
Outdoor Unit
D
In. [mm]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating) CFM
Sound Pressure Level
Cooling Heating
dB(A) dB(A)
Gas (O.D.) In. [mm]
Diameter
Liquid (O.D) In. [mm]
Piping
Indoor Drain In. [mm]
Max. Length
ft [m]
Max. Height
ft [m]
Electrical
Outdoor-Indoor5 Recommended Breaker Size
V, ph, Hz A
Refrigerant Type
Guaranteed Temperature Operation Range
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAYSST09A112AB
9,000 3,60012,200
585 1.5 0.820 -- -- -- -- -- -- -- 24.6 15.4 -- -- Yes 145170237 321399 109134201 286364
--
1922303743
--
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10.0] 7.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 81 [37] 1229/-- 48 -- 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0]
--
NAYSST12A112AB
12,000 1,50013,600
209 2.5 0.770 -- -- -- -- -- -- -- 23.1 13.0 -- -- Yes 145170237 321399 109134201 286364
--
1922303745
--
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10.0] 7.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 81 [37] 1229/-- 49 -- 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0]
--
NAYSST15A112AB
14,000 3,10018,200
1,080 2.7 0.780 -- -- -- -- -- -- -- 21.6 13.0 -- -- Yes 205272335 420533 170237300 385498
--
2632384449
--
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10.0] 9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 81 [37] 1243/-- 49 -- 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0]
--
Notes:
AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Optional
Optional
USNAP
Optional
Optional
Optional
NAYWST18A112AA
NAYSST18A112AA
18,000 5,80022,000
1,340 2.1 0.870 -- -- -- -- -- -- -- 20.5 13.4 -- -- Yes 258332417 522646 232299375 470581
--
2833384449
--
-- -- 12 [305] 36-5/16 [923] 9-13/16 [250] 28 [13.0] 14.0 15 34-5/8 [880] 33-1/16 [840] 13 [330] 121 [55] 1691/-- 54 -- 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0]
--
NAYWST24A112AA
NAYSST24A112AA
22,500 8,20031,400
1,800 5.1 0.750 -- -- -- -- -- -- -- 20.5 12.5 -- -- Yes 388469544 628738 347420487 562661
--
NAYWST30A112AA
NAYWST36A112AA
NAYSST30A112AA
30,700 9,80030,600
3,380 9.9 0.640 -- -- -- -- -- -- -- 16.0 9.1 -- -- No
NAYSST36A112AA
34,600 9,80034,600
4,249 11.9 0.620 -- -- -- -- -- -- -- 15.1 8.2 -- -- No
389639848887 389639848887
350576763798 350576763798
--
--
3441454953
32424951
32424951
--
-- -- 12-13/16 [325] 43-5/16 [1100] 9-3/8 [238] 37 [17.0] 17.1 20 34-5/8 [880] 33-1/16 [840] 13 [330] 119 [54] 1769/-- 55 -- 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0]
--
--
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 40 [18.0] 21.0 25 33-7/16 [850] 33-1/16 [840] 13 [330] 126 [57] 1941/-- 55 -- 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 25 R410A 14 to 115 [-10.0 to 46.0]
--
--
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 40 [18.0] 21.0 25 33-7/16 [850] 33-1/16 [840] 13 [330] 126 [57] 1941/-- 56 -- 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 25 R410A 14 to 115 [-10.0 to 46.0]
--
42 Nv-Series
NA(X/Y)WST Model
Indoor Unit
NAXWST24A112A* NAYWST24A112A*
Outdoor Unit
Remote Controller
NAXWST(30/36)A112A* NAYWST(30/36)A112A*
NAXSST30/36A112A* NAYSST30/36A112A*
NAXSST24A112A* NAYSST24A112A*
Blue Nano Fin Platinum
GWLS1T818
Smart Set
Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
MNSAZX-WGSLT0066-1-188
Heat Caulking Fixing Method
Indoor Unit
NAXWST06A112AA
NAXWST09A112AA
NAXWST12A112AA
NAXWST15A112AA
NAXWST18A112AA
NAXWST24A112AA
NAXWST30A112AA
NAXWST36A112AA
Outdoor Unit
NAXSST09A112AB
NAXSST12A112AB
NAXSST15A112AB
NAXSST18A112AA
NAXSST24A112AA
Capacity
Rated 1
BTU/H
--
9,000
12,000
14,000
18,000
22,400
Capacity Range
Min-Max BTU/H
--
3,60012,200 1,50013,600 3,10018,200 5,80022,000 8,20031,400
Cooling
Power Input
Rated 1
W
--
585
920
1,080
1,340
1,800
Moisture Removal
Pints/h
--
1.5
2.5
2.7
2.1
5.1
Sensible Heat Factor
--
0.820
0.740
0.800
0.870
0.750
Capacity at 47ºF
Rated 2
BTU/H
--
10,900
14,400
18,000
21,600
27,600
Capacity Range
Min-Max BTU/H
--
4,50015,900 2,00018,100 4,80020,900 5,40025,000 7,50036,900
Power Input at 47ºF
Rated 2
W
--
720
1,100
1,600
1,680
2,340
Heating
Capacity at 17ºF
Rated 3
BTU/H
--
Max
BTU/H
--
6,700 10,200
9,200 12,000
12,200 16,400
13,800 18,200
16,000 24,600
Capacity at 5ºF
Max 4
BTU/H
--
8,170
9,790
13,680
14,900
19,320
Capacity at -5ºF
Max 5
BTU/H
--
--
--
--
--
--
SEER
--
24.6
23.1
21.6
20.5
20.5
EER
--
15.4
13.0
13.0
13.4
12.5
Efficiency
HSPF
--
12.8
12.5
11.7
11.2
10.0
COP
--
4.44
3.84
3.3
3.77
3.46
ENERGY STAR® Certified
--
Yes
Yes
Yes
Yes
Yes
Indoor Unit
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi)
Wet
Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi)
Dry
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Cooling
Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Heating
CFM CFM CFM dB(A)
145170237 321399
109134201 286364
145170237 321406
145170237 321399
109134201 286364
145170237 321406
145170237 321399
109134201 286364
145170237 321406
205272335 420533
170237300 385498
205247304 367463
258332417 522646
232299375 470581
297385469 565646
388469544 628738
347420487 562661
388469544 628738
1922303743 1922303743 1922303745 2632384449 2833384449 3441454953
dB(A) 1922303743 1922303743 1922303743 2630354046 2833384348 3241454952
External Static Pressure
In. W.G.
--
--
--
--
--
--
Condensate Lift Mechanism
Max Distance In. [mm]
--
--
--
--
--
--
H
In. [mm] 11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
11-5/8 [295]
12 [305]
12-13/16 [325]
Dimensions
W
In. [mm] 31-7/16 [798] 31-7/16 [798] 31-7/16 [798] 31-7/16 [798] 36-5/16 [923] 43-5/16 [1100]
D
In. [mm] 9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-1/8 [232]
9-13/16 [250]
9-3/8 [238]
Weight
lbs [kg]
22 [10.0]
22 [10.0]
22 [10.0]
22 [10.0]
28 [13.0]
37 [17.0]
MCA
A
--
9.0
9.0
0.0
14.0
7.0
MOCP
A
--
15
15
15
15
20
H
In. [mm]
--
21-5/8 [550]
21-5/9 [550]
21-5/10 [550]
34-5/8 [880]
34-5/8 [550]
Dimensions
W
In. [mm]
--
31-1/2 [800]
31-1/2 [800]
31-1/4 [800]
33-1/16 [840] 33-1/16 [840]
Outdoor Unit
D
In. [mm]
--
11-1/4 [285]
11-1/5 [285]
11-1/6 [285]
13 [330]
13 [330]
Weight
lbs [kg]
--
81 [37]
81 [37]
81 [37]
121 [55]
119 [54]
Air Flow Rate (Cooling/Heating) CFM
--
1229/1172
1229/1172
1243/1129
1691/1691
1769/1701
Cooling
dB(A)
--
48
49
49
54
55
Sound Pressure Level
Heating
dB(A)
--
50
51
51
55
55
Gas (O.D.) In. [mm]
--
3/8 [9.52]
3/8 [9.52]
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
Diameter
Liquid (O.D) In. [mm]
--
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
Piping
Indoor Drain In. [mm] 5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
Max. Length
ft [m]
--
65 [20]
65 [20]
65 [20]
100 [30]
100 [30]
Max. Height
ft [m]
--
40 [12]
40 [12]
40 [12]
50 [15]
50 [15]
Electrical
Outdoor-Indoor 6 Recommended Breaker Size
V, ph, Hz A
--
208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
--
15
15
15
15
20
Refrigerant Type
--
R410A
R410A
R410A
R410A
R410A
Guaranteed Temperature Operation Range
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
--
14 to 115 [-10.0 to 46.0]
14 to 115 [-10.0 to 46.0]
14 to 115 [-10.0 to 46.0]
14 to 115 [-10.0 to 46.0]
14 to 115 [-10.0 to 46.0]
--
-4 to 75 [-20.0 to 24.0]
-4 to 75 [-20.0 to 24.0]
-4 to 75 [-20.0 to 24.0]
-4 to 75 [-20.0 to 24.0]
-4 to 75 [-20.0 to 24.0]
NAXSST30A112AA
30,600 9,80030,700
3,850 9.9 0.640 32,600 8,70034,000 3,360 19,500 20,800 -- -- 14.5 8.0 8.2 2.84 No 389639848 887 350576763 798 445639848 887
32424951
34424950
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 40 [18.0] 21.0 25 33-7/16 [850] 33-1/16 [840] 13 [330] 126 [57] 1941/1941 55 57 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 25 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
NAXSST36A112AA
33,200 9,80033,200
4,360 11.3 0.620 35,200 8,70036,000 3,840 21,800 22,800 -- -- 14.5 7.6 8.2 2.69 No 389639848 887 350576763 798 445639686 887
32424951
34424950
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 40 [18.0] 21.0 25 33-7/16 [850] 33-1/16 [840] 13 [330] 126 [57] 1941/1941 56 56 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 25 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Nv-Series 43
WMT Model
18 SEER Wall-mounted Indoor Unit
Stylish Design
A stylish flat panel design creates a simple look that matches any room aesthetics.
Quiet Operation
A quiet, relaxing space is within reach. Operational noise is as low as 22dB(A).
Human hearing limits
(Extremely quiet)
Sound of rustling leaves
Sound Level
Library interior
Quiet passenger car interior (25mph)
Subway car interior
Econo Cool Energy-Saving Feature
Econo Cool is an intelligent temperature control feature that adjusts the amount of air discharged based on the air-outlet temperature. The temperature setpoint can be raised up to 4° without any loss in comfort, thereby realizing a 20% gain in energy efficiency.
Ambient Temperature
Setpoint
Perceived Temperature
Conventional 95° F 77° F 86° F
Econo Cool 95° F 81° F 85° F
Econo Cool On
Conventional Cooling Mode
10dB(A)
22 Only dB(A) (for WMT09/12 models)
40dB(A) 60dB(A)
80dB(A)
Air Filter
This filter can remove dust particles from the air.
Anti-allergy Enzyme Filter* (*Optional)
This filter works to trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.
12-hour Timer
Allows for one ON/OFF cycle during a 12-hour period.
Blue Fin Heat Exchanger
Blue Fin is an anti-corrosion coating applied to the heat exchanger of the outdoor unit. This treatment prevents the deterioration of the aluminum fins caused by salt, especially in coastal areas. (Corrosion of the heat exchanger will affect the efficiency and performance of the outdoor unit.)
Temperature distribution (° F)
58 61 64 68 72 75 79 82
44 Nv-Series
WMT Model
Indoor Unit
NAXWMT09/12/15A112A*
Outdoor Unit
Remote Controller
NAXWMT18/24A112A*
NAXSMT09/12/15/18A112A* NAXSMT24A112A*
Optional Controller Holder: U01A01083
Blue Fin
Blue AiFr Finilter
Air Filter
Optional
Optional
12 hour
12 hour
Indoor Unit
NAXWMT09A112AA
NAXWMT12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSMT09A112AB
9,000 3,80010,000
750 1.5 0.820 10,900 4,50011,800 900 6,700 7,200 5,990 -- 18.0 12.0 10.0 3.55 No
170237321399
134201286364
170237321406
22303743
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 73 [33.1] 1151/1225 46 50 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
NAXSMT12A112AB
12,000 3,80012,200
1,210 2.5 0.770 12,200 4,50014,500 990 7,600 900 9,000 -- 18.0 9.9 10.0 3.61 No
170237321399
134201286364
170237321406
22303745
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 73 [33.1] 1151/1225 49 51 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Heat Caulking Fixing Method
NAXWMT15A112AA
NAXSMT15A112AB
14,000 3,10016,000
1,170 2.7 0.780 18,000 4,80018,500 1,600 11,500 14,000 12,240 -- 18.0 12.0 10.0 3.3 No
272335420533
237300385498
247304367463
32384449
30354046
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 81 [36.7] 1243/1229 49 51 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
NAXWMT18A112AA
NAXSMT18A112AB
17,200 5,80018,000
1,640 2.1 0.860 18,000 5,40020,900 1,590 11,500 15,000 12,780 -- 18.0 10.5 10.0 3.32 No
328431530625
295388477562
307431530625
30374247
30374247
-- -- 12 [305] 36-5/16 [923] 9-13/16 [250] 28 [13.0] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 81 [36.7] 1243/1229 50 51 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
NAXWMT24A112AA
NAXSMT24A112AA
22,500 5,80022,500
2,630 2.3 0.890 26,000 5,40026,000 2,500 18,500 18,500 15,600 -- 18.0 8.6 10.0 3.05 No
353431530702
318388477632
346448579702
33384450
32384450
-- -- 12 [305] 36-5/16 [923] 9-13/16 [250] 28 [13.0] 14.0 15 34-5/8 [880] 33-1/16 [840] 13 [330] 121 [55] 1691/1691 54 55 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
Nv-Series 45
WMT 115V Model
115V Wall-mounted Indoor Unit
Stylish Design with Flat Panel Front
A stylish flat panel design creates a simple look that matches the decor in any room.
Quiet Operation
A quiet, relaxing space is within reach. Operational noise is as low as 22dB(A).
Human hearing limits
(Extremely quiet)
Sound of rustling leaves
Sound Level
Library interior
Quiet passenger car interior (25mph)
Subway car interior
Econo Cool Energy-Saving Feature
Econo Cool is an intelligent temperature control feature that adjusts the amount of air discharged based on the air-outlet temperature. The temperature setpoint can be raised up to 4° without any loss in comfort, thereby realizing a 20% gain in energy efficiency.
Ambient Temperature
Setpoint
Perceived Temperature
Conventional 95° F 77° F 86° F
Econo Cool 95° F 81° F 85° F
Econo Cool On
Conventional Cooling Mode
10dB(A)
22 Only dB(A) (for WMT09/12 models)
40dB(A) 60dB(A)
80dB(A)
Air Filter
This filter can remove dust particles from the air.
Anti-allergy Enzyme Filter* (*Optional)
This filter works to trap allergens such as bacteria and decompose them using enzymes retained in the filter.
12-hour Timer
Allows for one ON/OFF cycle during a 12-hour period.
Blue Fin Heat Exchanger
Blue Fin is an anti-corrosion coating applied to the heat exchanger of the outdoor unit. This treatment prevents the deterioration of the aluminum fins caused by salt, especially in coastal areas. (Corrosion of the heat exchanger will affect the efficiency and performance of the outdoor unit.)
Temperature distribution (° F)
58 61 64 68 72 75 79 82
46 Nv-Series
WMT 115V Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXWMT(09/12)A111A*
NAXSMT(09/12)A111A*
Blue Fin
Blue AiFr Finilter
Air Filter
Optional
Optional
12 hour
12 hour
Indoor Unit
NAXWMT09A111AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSMT09A111AA
9,000 3,80010,000
750 1.5 0.820 10,900 4,50011,800 900 6,700 7,200 5,990 -- 17.0 12.0 9.0 3.55 No
170237321399
134201286364
170237321406
22303743
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 12.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 73 [33] 1105/1225 46 46 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 40 [12] 65 [20] 115, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Heat Caulking Fixing Method
NAXWMT12A111AA
NAXSMT12A111AA 12,000
3,80012,000 1,210 2.5 0.770 12,200
4,50014,500 990 7,600 9,000 7,440 -- 17.0 9.9 9.0 3.61 No
170237321399
134201286364
170237321406
22303743
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 14.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 73 [33] 1105/1225 49 50 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 40 [12] 65 [20] 115, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to 75 [-20.0 to 24.0]
Nv-Series 47
WEL Model
16 SEER Wall-mounted Indoor Unit
Stylish Design with Flat Panel Front
A stylish flat panel design creates a simple look that matches the decor in any room.
Quiet Operation
A quiet, relaxing space is within reach. Operational noise is as low as 22dB(A).
Human hearing limits
(Extremely quiet)
Sound of rustling leaves
Sound Level
Library interior
Quiet passenger car interior (25mph)
Subway car interior
Econo Cool Energy-Saving Feature
Econo Cool is an intelligent temperature control feature that adjusts the amount of air discharged based on the air-outlet temperature. The temperature setpoint can be raised up to 4° without any loss in comfort, thereby realizing a 20% gain in energy efficiency.
Ambient Temperature
Setpoint
Perceived Temperature
Conventional 95° F 77° F 86° F
Econo Cool 95° F 81° F 85° F
Econo Cool On
Conventional Cooling Mode
10dB(A)
22 Only dB(A)
(for WEL09/12 models)
40dB(A) 60dB(A)
80dB(A)
Air Filter
This filter can remove dust particles from the air.
Anti-allergy Enzyme Filter* (*Optional)
This filter works to trap allergens such as bacteria and decompose them using enzymes retained in the filter.
12-hour Timer
Allows for one ON/OFF cycle during a 12-hour period.
Blue Fin Heat Exchanger
Blue Fin is an anti-corrosion coating applied to the heat exchanger of the outdoor unit. This treatment prevents the deterioration of the aluminum fins caused by salt, especially in coastal areas. (Corrosion of the heat exchanger will affect the efficiency and performance of the outdoor unit.)
Temperature distribution (° F)
58 61 64 68 72 75 79 82
48 Nv-Series
WEL Model
Indoor Unit
NAXWEL09/12A112A*
Outdoor Unit
Remote Controller
NAXWEL18/24A112A*
NAXSEL(09/12)A112AB NAXSEL(18/24)A112AB
Blue Fin
Blue AiFr Finilter
Air Filter
Optional
Optional
12 hour
12 hour
Indoor Unit
NAXWEL09A112AA
NAXWEL12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSEL09A112AB
9,000 3,80010,000
820 1.5 0.820 10,900 4,50011,800 980 6,700 7,200 5,990 -- 16.0 11.0 8.5 3.25 No
170237321399
134201286364
170237321406
22303743
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 73 [33] 1151/1225 51 51 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 40 [12] 65 [20] 208/230, 1, 60 15 R410A 32 to 115 [-10.0 to 46.0] 5 to 75 [-20.0 to 24.0]
NAXSEL12A112AB
12,000 3,80012,200
1,330 2.5 0.770 12,200 4,50014,500 1,090 7,600 9,000 7,440 -- 16.0 9.0 8.5 3.28 No
170237321399
134201286364
170237321406
22303745
22303743
-- -- 11-5/8 [295] 31-7/16 [798] 9-1/8 [232] 22 [10] 10.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [286] 73 [33] 1243/1229 53 51 1/2 [12.7] 1/4 [6.35] 5/8 [15.88] 40 [12] 65 [20] 208/230, 1, 60 15 R410A 32 to 115 [-10.0 to 46.0] 5 to 75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Heat Caulking Fixing Method
NAXWEL18A112AA
NAXSEL18A112AB 17,200
5,80018,000 1,720 2.1 0.860 18,000
5,40020,900 1,670 11,500 15,000 12,780 -- 16.0 10.0 8.5 3.16 No
328431530625
295388477562
307431530625
30374247
30374247
-- -- 12 [305] 36-5/16 [923] 9-13/16 [250] 28 [13] 9.0 15 34-5/8 [880] 31-1/16 [840] 13 [330] 121 [55] 1151/1225 48 50 3/8 [9.52] 1/4 [6.35] 5/8 [15.88] 40 [12] 65 [20] 208/230, 1, 60 15 R410A 32 to 115 [-10.0 to 46.0] 5 to 75 [-20.0 to 24.0]
Optional Controller Holder: U01A01083
NAXWEL24A112AA
NAXSEL24A112AA 22,500
5,80022,500 2,810 2.3 0.890 26,000
5,40026,000 2,680 18,500 18,500 15,600 -- 16.0 8.0 8.5 2.84 No
353431530702
318388477632
346448579702
33384450
32384450
-- -- 12 [305] 36-5/16 [923] 9-13/16 [250] 28 [13] 14.0 15 34-5/8 [880] 31-1/16 [840] 13 [330] 121 [55] 1691/1691 57 55 5/8 [15.88] 3/8 [9.52] 5/8 [15.88] 50 [15] 100 [30] 208/230, 1, 60 15 R410A 32 to 115 [-10.0 to 46.0] 5 to 75 [-20.0 to 24.0]
Nv-Series 49
FKS Model
Floor-mounted Indoor Unit
Simple Flat Design
Unique modern design
Two-block structure to accommodates partially recessed installation
Images of installed unit
Standard
23-5/8"
Low profile air inlet
Semi-inbuilt
When heating
29-17/32"
Air currents can be controlled freely
Multi-Flow Vane
When heating
Air currents can be controlled freely
Rapid heating
Warm air is blown out in a downward direction and then sucked back into the unit to quickly raise the temRpapeirdathuereatoinf gthe air being blown out. Warm air is blown out in a downward direction and then sucked back into the unit to quickly raise the temperature of the air being blown out.
Removable base section
5-23/32" 8-15/32"
Air Distribution (NTXFKS15A112AA) (sectional view)
10 min later
Outside Temp: 5° F Set Temp: 73° F Fan mode: auto
30 min later
When cooling
Base can be removed to accentuate the stylish
main body
When cooling *The downward airflow is also possible as well as heating.
*The downward airflow is also possible as well as heating.
Even distribution of warm air throughout the room
60 min later
80° F
Air Distribution (NTXFKS15A112AA) (sectional view)
10 min later
Outside Temp: 5° F Set Temp: 73° F Fan mode: auto
30 min later
Even distribution of warm air throughout the room
60 min later
80° F
41° F
All FKS single-zone systems are ENERGY STAR® certified.
41° F
50 Nv-Series
FKS Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXFKS(09/12/15/18) A112A*
NAXFKS(09/12)A112A*
NAXFKS(15/18)A112A*
Blue Nano Fin Platinum
Optional
POWERFUL MODE
USNAP
Optional
Optional
Optional
T-STAT
Optional
Indoor Unit
NAXFKS09A112AA
NAXFKS12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSPF09A112AA
9,000 2,30014,000
570 1.4 0.790 11,000 2,90019,000 750 7,500 13,400 11,000 -- 28.2 15.8 13.0 4.3 Yes
138198272360417
117168231306354
138191254328417
2127344146
2127344046
-- -- 23-5/8 [600] 29-17/32 [750] 8-15/32 [215] 33 [15.0] 11.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 83 [38] 1074/1202 48 50 3/8 [9.52] 1/4 [6.35] 5/8 O.D [15] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXSPF12A112AA
12,000 2,30015,000
890 2.7 0.700 13,000 2,90022,800 900 8,800 14,800 13,000 -- 25.5 13.6 12.0 4.2 Yes
138198272360417
117168231306354
138191254328417
2127344146
2127344046
-- -- 23-5/8 [600] 29-17/32 [750] 8-15/32 [215] 33 [15.0] 11.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 83 [38] 1074/1202 48 50 3/8 [9.52] 1/4 [6.35] 5/8 O.D [15] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Sleep
Optional
Optional
Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
NAXFKS15A112AA
NAXSPF15A112AA
15,000 5,30019,000
1,120 3.9 0.660 18,000 5,70025,000 1,410 12,000 20,500 18,000 -- 21.8 13.5 11.6 3.7 Yes
198254311392431
NAXFKS18A112AA
NAXSPF18A112AA
17,000 5,30022,500
1,350 4.4 0.650 21,000 5,70029,000 1,730 12,800 23,000 21,000 -- 21.0 12.6 11.3 3.5 Yes
198254328420491
168216264333366
168216279357417
212268328399470
212268328399470
2833384347
2833394550
2935404549
-- -- 23-5/8 [600] 29-17/32 [750] 8-15/32 [215] 33 [15.0] 16.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 124 [56] 1653/1730 51 55 1/2 [12.7] 1/4 [6.35] 5/8 O.D [15] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
2935404549
-- -- 23-5/8 [600] 29-17/32 [750] 8-15/32 [215] 33 [15.0] 16.0 20 34-5/8 [880] 33-1/16 [840] 13 [330] 124 [56] 1653/1730 51 55 1/2 [12.7] 1/4 [6.35] 5/8 O.D [15] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Nv-Series 51
Konnect Series
Universal Outdoor Unit
NAXSKS(09/12/15)A112A*
NAXSKS(18/24/30/36)A112A* NAXSKH(09/12/15/18)A112A*
UKS
CKS
DKS
PEAD
System Compatibility
Model CKS DKS PEAD AMT
UKS Hyper-Heating
Outdoor Unit Capacity KBTU/H
Type
2' x 2' cassette
Low static ducted
Mid static ducted
Multi-position Air Handler
EZ FIT® Recessed Ceiling Cassette
HP=Heat Pump
AMT
9
HP
·
·
·
·
·
·
12
HP
·
·
·
·
·
·
·
·
15
HP
·
·
·
·
·
·
18
HP
·
·
·
·
·
·
·
·
24 HP
·
·
·
·
30 HP
·
·
·
·
36 HP
·
·
·
·
·
·
·
·
·
·
Most Konnect systems are ENERGY STAR® certified.
52 Nv-Series
Hyper-Heating INVERTER®
The Hyper-heat models provide heating even when it's -13° F (-25° C) outdoor ambient temperature, producing up to 100% heating capacity at 5° F (-15° C). These units offer year-round comfort even in extreme climates.
Heating Capacity (%)
Operation guaranteed at 13° F, 100% heating capacity at 5° F
Hyper-heat Konnect Series Standard Heat Pump
100%
Heating operation down to
-13° F (-25° C)
100% heating capacity as low as
5° F (-15° C)
-13° F (-25° C)
-4° F 5° F (-20° C) (-15° C)
19° F (-7° C)
32° F (0° C)
Outdoor Air Temperature
OOppeerraattiioonngguurraarraanntteeeeddaattmmiinnuuss--1133°°FF,, 110000%%hheeaattiinnggccaappaaccttiiyyaatt--55°°FF
HHeeaattiinngg CCaappaacciittyy ((%%))
110000%%
hheeaattiinngg
HHeeaattiinngg
Built-in Base Heater ooppeerraattiioonn ddoowwnnttoo
ccaappaacciittyy aasslloowwaass
55°°FF
--1133°°FF
The base heater restricts lowered capacity and 110000%%
operation shutdowns caused by the drain water
freezing. This feature supports stable operation in
low-temperature environments.
Operation Guaranteed at Outsid--11e33oToFeFmpera--4t4ouoFrFe of 1535oo°FFF (25° C) 1199ooFF
OOuuttddoooorr--aaiirrTTeemmppeerraattuurree
3322o o FF
Heating Performance at Low Temperatures
NAXSKH09A112A* COP at CKS DKS PEAD UKS
47° F 3.90 2.80 3.80 4.10 17° F 2.56 2.20 2.56 2.76 5° F 1.34 1.59 1.67 1.67
NAXSKH12A112A* COP at CKS DKS PEAD AMT UKS
47° F 3.40 3.90 3.90 3.80 3.80 17° F 2.38 2.56 2.72 2.61 2.54 5° F 1.83 2.19 2.09 1.69 1.57
NAXSKH15A112A* COP at CKS DKS PEAD
47° F 2.60 2.70 3.00 17° F 1.91 2.15 2.29 5° F 1.84 1.88 1.81
NAXSKH18A112A* COP at CKS DKS PEAD AMT UKS
47° F 2.70 3.40 3.30 3.30 3.00 17° F 2.20 2.52 2.49 2.32 2.42 5° F 1.44 1.75 1.66 1.75 1.39
NAXSKH24A112AA*
NAXSKH30A112AA*
NAXSKH36A112AA*
COP at PEAD AMT COP at PEAD AMT COP at PEAD AMT
47° F 3.80 3.10BBaasseeHHe4ea7a°tteFerreeqq3u.u4i0ippppeed3d.9aa0ssssttaanndda4a7rrd°dF** 3.70 3.30
17° F 2.10 1.80
17° F 2.10 2.00
17° F 2.20 1.80
5° TFThheebb1aa.7sse5ehheeaa1tt.e6er0rrreessttrriiccttss5llo°owFweerreed1d.7cc5aappaacci1itt.y7y5aannddooppeerra5a°ttiFioonnsshh1uu.7tt5ddoowwn1ns.s60 ccaauusseeddbbyytthheeddrraaiinnwwaatteerrffrreeeezziinngg..TThhiissffeeaattuurreessuuppppoorrttssssttaabbllee
ooppeerraattiioonniinnllooww--tteemmppeerraattuurreeeennvviirroonnmmeennttss..
FFrroozzeenn ddrraaiinn
DDrraaiinnddooeess nnoottffrreeeezzee
WWiitthhoouuttBBaasseeHHeeaatteerr
WWiitthhBBaasseeHHeeaatteerr
Compact and Powerful CompressorNNTTXXSSPPHH SSttaannddaarrddHHeeaattPPuummpp
**SSttaannddaarrddffoorrNNTTXXSSPPBBmmooddeelsls OOppttioionnaallffoorrNNTTXXSSPPHHmmooddeelsls
Manufacturing with Heat Caulking Fixing Method reduces compressor size while maintaining a high compressor output. This technology enables the installation of a more powerful compressor in compact outdoor units. As a result, it is possible to achieve excellent heating performance while operating in cold outdoor environments.
Compressor Using Conventional Method (Arc Spot-Welded Method)
Compressor Using Heat Caulking Fixing Method
TNB220F
Reduced by 13%
SNB220F
Outer layer must be thick enough to hold the cylinder.
Compressor size reduced while maintaining same cylinder inner diameter.
Nv-Series 53
UKS Model
EZ FIT® Recessed Ceiling Cassette
Slim Design
Ceiling Recessed
The EZ FIT flush-mount design creates a more spacious feeling in the room. The recessed-ceiling-cassette indoor unit style provides a solution when wall space is limited or not available.
Slim Body
The new units are built with a slim body (only 7-5/16"), ensuring easy installation even when shallow ceiling cavities limit installation space. The inventive design also eliminates the need for an extra service access panel, further reducing the required installation area.
7-5/16"
Set Airflow According to Ceiling Height
Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the ceiling height.
Standard High Ceiling
09
12
18
7' 10-1/2" 7' 10-1/2" 7' 10-1/2"
8' 10-1/2" 8' 10-1/2" 8' 10-1/2"
54 Nv-Series
Auto Vane Control
Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature eliminates drafts..
Up and Down
Left and Right
Only available when Econo Cool is set.
Built-in Weekly Timer Function
Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
Example Operation Pattern (Winter/Heating mode)
Mon.
Tues.
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
ON 68°F
AM
Automatically changes to high-power operation at wake-up time
AM
AM
OFF
AM
PM
OFF
OFF
OFF
Automatically turned off during work hours
OFF
ON 64°F
ON 64°F
Midday is warmer, so the temperature is set lower
PM
PM
PM
PM
(during sleeping
hours)
ON 72°F ON 64°F
ON 72°F
ON 72°F
ON 72°F
Automatically turns on, synchronized with arrival at home
ON 72°F
ON 72°F
ON 72°F
Automatically raises temperature setting to match time when outside-air temperature is low
ON 64°F
ON 64°F
ON 64°F
ON 64°F
Automatically lowers temperature at bedtime for energy-saving operation at night
ON 64°F
ON 64°F
Settings
Pattern Settings: Input up to four settings for each day Settings: ·Start/Stop operation ·Temperature setting The operation mode cannot be set.
Easy Set-Up Using Dedicated Buttons
The remote controller is equipped
with buttons that are used exclusively for setting the WetHheoewkWlteyoeskelyt Timer. Setting operation patteTrnimseris
easy and quick.
PUSH
Ready to set
How to set the Weekly
Timer PUSH
SePleUcSt Hthe day
PUSH
PUSH
PUSH
PUSH
ReadyPtUoSH set
Select the period
PUSH
PUSH
PUSH
PUSH
Select the day
Select the period
PUSH
PUSH
Complete
Complete
Select ON/OFF
Select the time
Set the temperature
SeleSctt OaNr/tOFbFy puSsehlecitnthge titmhe e SSEeTt thbe tuemtpteoratnureand follow the instructions to set the desired
patterns. Once all of the desired patterns are input, point the top end of the
remote controller at the indoor unit and push the SET button one more time.
(Push the SET button only after inputting all of the desired patterns into the
remote controller memory. Pushing the CANCEL button will end the set-up
process without sending the operation patterns to the indoor unit).
Nv-Series 55
Easy Installation
Industry Leading Slim Body
The EZ FIT® installs between standard joists that span 16 inches on center. There is no need for largescale construction, such as the cutting of the joist.
Temporary Hanging Hook
within 16 inches
Secure one side
Drain Piping Supporters and Drain Cover
Drain piping
Push the unit to one side Secure the opposite side
Move unit to the center
Easy joint connections! 19-11/16in.
Insulating material wrapping only required from this point
Insulating material pretreatment eliminates need for wrapping.
No need for wrapping
Insulation-free cover collects condensation
in the drain pan.
Drain cover
Wireless Interface Installation (Optional)
The indoor unit panel is equipped with a Wireless Interface pocket, contributing to the beautiful appearance, easy installation and maintenance.
Wireless Interface pocket
56 Nv-Series
UKS Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXUKS(09/15/18)A112A*
NAXSKS09/12A112A*
NAXSKS18A112A*
Air Purifying
Optional
Weekly Timer
*Requires ALP-444W grille
Optional
Optional
Indoor Unit
NAXUKS09A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKS09A112AA
9,000 3,6009,000
710 1.5 0.820 12,000 4,01013,000 860 7,700 7,700 6,100 -- 19.5 12.6 13.3 4.0 Yes
212254283311
180216240264
212247290325
27313438
26293437
-- 19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 9.0 15
21-5/8 [550] 31-1/2 [800] 11-1/4 [285]
81 [37] 1228/1172
48 50 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Optional
Wi-Fi
Interface
Optional
NAXUKS12A112AA
NAXSKS12A112AA
12,000 3,90012,000
960 2.8 0.740 15,400 4,60017,000 1,300 9,900 9,900 7,900 -- 19.8 12.5 12.1 3.4 Yes
212258297332
180219252282
212272311350
27323640
26323640
-- 19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 9.0 16
21-5/8 [550] 31-1/2 [800] 11-1/4 [285]
81 [37] 1228/1172
49 51 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
10°C Sleep
NAXUKS18A112AA NAXSKS18A112AA
18,000 6,60018,000
1,440 5.3 0.670 20,000 8,20022,800 1,170 13,100 13,100 10,700 -- 22.3 12.5 12.4 3.3 Yes 212293346403
180249294343
212311364417
29364147
26374248 --
19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 14.0 24
34-5/8 [880] 33-1/16 [840]
13 [330] 127 [58] 1691/1691
54 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Nv-Series 57
UKS Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXUKS(09/15/18)A112A*
NAXSKH(09/12/18)A112A*
Air Purifying
Optional
Weekly Timer
*Requires ALP-444W grille
Optional
Optional
Indoor Unit
NAXUKS09A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKH09A112AA
9,000 4,8009,000
720 1.8 0.780 12,000 8,30014,000 840 6,600 12,000 12,000 -- 18.9 12.5 11.0 4.1 Yes
212254283311
180216240264
212247290325
27313438
26293437
-- 19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 14.0 24
34-5/8 [880] 38-1/16 [840]
13 [330] 129 [58.5] 1,691/1,691
54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Optional
Wi-Fi
Interface
Optional
NAXUKS12A112AA
NAXSKH12A112AA
12,000 5,27012,000
940 3.1 0.710 15,000 7,80018,000 1,130 9,100 15,000 15,000 -- 19.0 12.7 10.2 3.8 Yes
212258297332
180219252282
212272311350
27323640
26323640
-- 19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 14.0 24
34-5/8 [880] 33-1/16 [840]
13 [330] 129 [58.5] 1,691/1,691
54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
58 Nv-Series
10°C Sleep
NAXUKS18A112AA
NAXSKH18A112AA 16,700
8,74016,700 1,335 5.1 0.660 18,600
8,50022,000 1,780 11,800 18,600 18,600 -- 18.8 12.5 10.0 3.0 Yes
212293346403
180249294343
212311364417
29364147
26374248
-- 19-11/16 [500] 7-5/16 [185] 43-3/8 [1102] 14-3/16 [360]
34 [15.5] 17.0 31
34-5/8 [880] 33-1/16 [840]
13 [330] 131 [59.5] 2,020/1,930
55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
AMT Model
Multi-position Air Handler
The Multi-position air handler is well-suited for supplemental or replacement applications. This product provides the powerful, quiet, and efficient cooling and heating solution your home or business deserves.
or
Multi-position Air Handler
Attic
Bedroom
Bedroom
Bedroom
Wall-mounted MX
Kitchen
Living Room
Sunroom
Small Footprint
This air handler's compact design makes it possible to replace existing furnaces or air handlers. Choose either a single-zone or multi-zone system. Hybrid multi-zone applications provide a unique approach to solving zoning problems by mixing ducted and ductless indoor units.
Flexibility
Quiet
The AMT air handler is truly Multi-positional unit offering up, down*, left or right airflow, making it ideal for tight and unique spaces.
*Downflow kit required for downflow installations
The DC motor ensures quiet and efficient operation year round.
Nv-Series 59
AMT Model
Indoor Unit
Outdoor Unit
NAXAMT(12/18/24/30/36)A112A*
NAXSKS12A112A* NAXSKS(18/24/30/36)A112A*
Air Filter
Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Indoor Unit
NAXAMT12A112AA
NAXAMT18A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKS12A112AA
12,000 4,30012,000
940 1.2 0.890 15,000 4,70016,700 1,210 9,900 9,900 7,800 -- 18.0 12.7 12.1 3.6 Yes
278381448
--
278381448
293639
293639
0.300.50.8 --
34-5/8 [880] 33-1/16 [840]
13 [330] 93 [42]
9.0 16 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1228/1172 49 51 3/8 [9.52] 1/4 [6.35] 3/4 [19.05] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
NAXSKS18A112AA
18,000 6,20018,000
1,360 2.4 0.850 21,600 8,30026,000 1,600 14,000 14,000 12,200 -- 18.0 13.2 12.6 3.9 Yes
471573675
--
471573675
333641
333641
0.300.50.8 --
39-13/16 [1011] 17 [432]
21-5/8 [549] 93 [42] 14.0 24
34-5/8 [880] 33-1/16 [840]
13 [330] 127 [58] 1691/1691
54 55 1/2 [12.7] 1/4 [6.35] 3/4 [19.05] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
NAXAMT24A112AA
NAXSKS24A112AA
24,000 12,40024,000
1,920 4.1 0.810 25,000 14,60028,000 1,910 14,600 14,600 -- -- 18.0 12.5 10.4 3.8 Yes
515625735
--
515625735
333641
333641
0.300.50.8 --
39-13/16 [1011] 17 [432]
21-5/8 [549] 93 [42] 17.0 31
34-5/8 [880] 33-1/16 [840]
13 [330] 129 [59] 2020/1930
55 55 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
NAXAMT30A112AA
NAXSKS30A112AA
27,000 13,50027,000
2,160 2.4 0.900 30,000 12,64033,000 2,060 21,400 21,400 -- -- 18.0 12.5 13.6 4.2 Yes
613744875
--
613744875
323741
323741
0.300.50.8 --
43-3/4 [1111] 21 [533]
21-5/8 [549] 119 [54] 17.0 31
34-5/8 [880] 33-1/16 [840]
13 [330] 129 [59] 2020/1930
55 55 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
NAXAMT36A112AA
NAXSKS36A112AA
33,400 11,60033,400
3,711 4.7 0.840 33,400 13,26036,000 3,030 23,200 23,200 -- -- 16.0 9.0 11.7 3.2 No
767910910
--
767910910
354042
354042
0.300.50.8 --
43-3/4 [1111] 21 [533]
21-5/8 [549] 119 [54] 17.0 31
34-5/8 [880] 33-1/16 [840]
13 [330] 129 [59] 2020/1930
55 55 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
60 Nv-Series
AMT Model
Indoor Unit
Outdoor Unit
NAXAMT12/18 /24/30/36A112A*
NAXSKH(12/18)A112A*
NAXSKH24A112A*
NAXSKH(30/36)A112A*
Air Filter
Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
Indoor Unit
NAXAMT12A112AA
NAXAMT18A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKH12A112AA
12,000 5,60012,000
860 0.8 0.920 15,000 7,70018,000 1,130 8,900 15,000 15,000 -- 19.0 13.9 10.2 3.8 Yes
278381448
--
278381448
293639
293639
0.300.50.8 --
34-5/8 [880] 33-1/16 [840]
13 [330] 93 [42] 14.0
24 34-5/8 [880] 33-1/16 [840]
13 [330] 129 [58.5] 1,691/1,691
54 55 3/8 [9.52] 1/4 [6.35] 3/4 [19.05] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXSKH18A112AA
18,000 9,36018,000
1,440 1.1 0.930 21,600 8,80028,000 1,880 14,300 21,600 21,600 -- 18.4 12.5 10.4 3.3 Yes
471573675
--
471573675
333641
333641
0.300.50.8 --
39-13/16 [1011] 17 [432]
21-5/8 [549] 93 [42] 17.0 31
34-5/8 [880] 33-1/16 [840]
13 [330] 131 [59.5] 2,020/1,930
55 55 1/2 [12.7] 1/4 [6.35] 3/4 [19.05] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
NAXAMT24A112AA
NAXSKH24A112AA
24,000 8,80024,000
2,420 4.7 0.780 23,000 9,40028,800 2,140 19,200 23,000 23,000 -- 16.0 9.9 9.2 3.1 No
515625735
--
515625735
333641
333641
0.300.50.8 --
39-13/16 [1011] 17 [432]
21-5/8 [549] 93 [42] 17.0 27
37-1/8 [943] 37-13/32 [950] 14-3/16 [360]
190 [86] 800/800
52 53 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXAMT30A112AA
NAXSKH30A112AA
27,000 13,40027,000
2,100 4.1 0.830 32,000 13,00034,000 2,400 21,400 32,000 32,000 -- 15.0 12.5 9.0 3.9 Yes
613744875
--
613744875
323741
323741
0.300.50.8 --
43-3/4 [1111] 21 [533]
21-5/8 [549] 119 [54] 24.0 40
52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360]
261 [118] 590/680
52 53 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXAMT36A112AA
NAXSKH36A112AA
36,000 14,20036,000
3,760 8.4 0.740 37,000 13,80040,000 3,280 32,800 37,000 37,000 -- 16.0 9.5 9.0 3.3 No
767910910
--
767910910
354042
354042
0.300.50.8 --
43-3/4 [1111] 21 [533]
21-5/8 [549] 119 [54] 26.0 42
52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360]
261 [118] 590/680
52 53 5/8 [15.88] 3/8 [9.52] 3/4 [19.05] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Nv-Series 61
CKS Model
Four-way Ceiling Cassette
Flexibility
The attractive CKS Model ceiling cassette units offer a slim width and a four-way air outlet. The size and shape are a perfect match for ceilings made using 2'×2' construction and its light weight package makes installation easy.
The compact body matches 2'×2' ceiling construction specifications.
NAXCKS12A112A*
16-17/32 8-3/16
22-7/16 "
22-7/16 "
22-7/16
Suspension LEG
Bolt to bolt 20-7/8
Suspension bolt
Fresh-air Intake
T-bar
Ceiling panel
Unit 22-7/16 22-11/16 23-5/8
Access door is required
9-21/32
(unit: in.)
A duct hole is provided in the main body, making it possible to intake fresh air from outside.
Static pressure: P [in. W.G.×10-2]
20
Intake-air volume
Fresh-air intake
Detail drawing of fresh-air intake
3-15/16
3- 1/8 hole Burring hole
1 2-7/8
Cut-out hole
20
40
60
80
0
-20
-40
-60
Airflow: Q [CFM]
100
120
4-21/32 120°
Drain pipe
Electrical box Refrigerant pipe
Ceiling surface
120°
-80
-100
-120 Note: Fresh-air intake amount should be 20% or less of whole air amount to prevent dew dripping. Booster fan required.
62 Nv-Series
CKS Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXCKS(09/12/15/18)A112A*
NAXSKS(09/12/15)A112A* NAXSKS18A112A*
*optional PAR-SL100A-E
*optional AAR-40MAAU
Optional
ALP-18FAU (standard grille) ALP-18FAEU (3D i-see Sensor® grille)
Optional
Optional Optional
Optional
Optional
USNAP
Optional
Optional
USNAP
Heat Caulking Fixing Method
Optional
Optional
Optional
T-STAT
Optional
T-STAT
Optional
Optional
*optional
PAC YT53CRAU-J
*optional PAR-CT01MAU-SB
Indoor Unit
NAXCKS09A112AA
NAXCKS12A112AA
NAXCKS15A112AA
NAXCKS18A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKS09A112AA
9,000 3,6009,000
670 1.0 0.870 11,000 4,01012,000 4,010 6,900 6,900 5,600 -- 22.4 13.4 12.2 3.9 Yes
230265300
207239270
230265335
252831
252831
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1228/1172 48 50 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
NAXSKS12A112AA
12,000 3,90012,000
900 2.8 0.740 13,000 4,80013,000 4,800 8,900 8,900 6,100 -- 22.0 13.3 11.4 2.9 Yes
230265335
207252302
230265335
253034
253034
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
9.0 16 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1228/1172 49 51 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
NAXSKS15A112AA
14,100 5,10014,100
1,150 3.2 0.750 18,000 5,10019,100 5,100 11,900 11,900 8,900 -- 19.8 12.2 11.2 3.0 No
245315405
221284365
245315405
273439
273439
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
10.0 18 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1243/1229 49 51 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
NAXSKS18A112AA 17,700
6,10017,700 1,410 4.7 0.710 19,700
8,40020,900 8,400 12,900 12,900 9,800 -- 20.7 12.5 11.6 3.1 Yes
300420475
270378429
300420475
324043
324043
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 127 [58] 1691/1691 54 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Nv-Series 63
CKS Model Indoor Unit
Outdoor Unit
Remote Controller
NAXCKS(09/12/15/18)A112A*
NAXSKH(09/12/15/18)A112A*
*optional PAR-SL100A-E
*optional AAR-40MAAU
Optional
ALP-18FAU (standard grille) ALP-18FAEU (3D i-see Sensor® grille)
Optional
Optional Optional
Optional
Optional
USNAP
Optional
Optional
USNAP
Heat Caulking Fixing Method
Optional
Optional
Optional
T-STAT
Optional
Optional
T-STAT
Optional
*optional
*optional
PAC YT53CRAU-J PAR-CT01MAU-SB
Indoor Unit
NAXCKS09A112AA
NAXCKS12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKH09A112AA
9,000 4,8009,000
600 1.9 0.770 11,000 7,40013,200 820 6,300 11,000 11,000 -- 20.2 15.0 10.0 3.9 Yes
230265300
207239270
230265335
252831
252831
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
14.0 24 34-5/8 [880] 38-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXSKH12A112AA
12,000 5,07012,000
940 3.1 0.710 13,800 7,80014,500 1,170 8,300 13,800 13,800 -- 20.3 12.7 10.0 3.4 Yes
230265335
207252302
230265335
253034
253034
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
NAXCKS15A112AA
NAXSKH15A112AA
13,700 8,50013,700
1,095 3.4 0.720 16,400 8,30019,000 1,830 9,700 16,400 16,400 -- 17.7 12.5 9.0 2.6 Yes
245315405
221284365
245315405
273439
273439
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXCKS18A112AA
NAXSKH18A112AA
16,800 9,01016,800
1,340 4.2 0.720 18,800 8,30020,000 2,020 12,100 18,800 18,800 -- 19.0 12.5 9.4 2.7 Yes
300420475
270378429
300420475
324043
324043
-- 33 [850] 9-21/32 [245] 22-7/16 [570] 22-7/16 [570] 31 [13.9]
17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
64 Nv-Series
DKS Model
Low Static Horizontal-ducted
Indoor Unit
Compact Ceiling-Concealed Units
Only the intake-air grille and outlet vents are visible when using the DKS Model ceiling-concealed indoor unit. The compact design requires minimal space and installs in buildings with lowered ceilings or attics.
E
B
D
C
F GA
A Air inlet B Air outlet C Access door D Ceiling surface E Canvas duct F Air filter G Inlet grille
Selection of Fan Speeds and Static Pressure Levels
Three fan speed settings (Low, Medium, and High) and four static pressure levels are available for all capacities.
Sound Levels
09
Static Pressure Levels
Low
Medium High
DKS 09-18
23 dB(A)
26 dB(A) 30 dB(A)
0.02-0.06-0.14-0.20 In.W.G.
12
23 dB(A)
28 dB(A) 33 dB(A)
15
30 dB(A)
34 dB(A) 37 dB(A)
18
30 dB(A)
34 dB(A) 38 dB(A)
Nv-Series 65
DKS Model
Indoor Unit
Outdoor Unit
Remote Controller
NAXDKS(09/12/15/18)A112A*
NAXSKS(09/12/15)A112A* NAXSKS18A112A*
AT
l
Optional
VAQ Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
Heat Caulking Fixing Method
Indoor Unit
NAXDKS09A112AA
NAXDKS12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKS09A112AA
9,000 3,9009,000
700 1.5 0.820 12,000 4,20012,800 1,100 7,600 6,700 6,000 -- 18.8 12.8 11.0 3.1 Yes
194247317
174222285
194247317
232630
232630
0.020.060.140.2 2121/32 [550] 7-7/8 [200] 31-1/8 [790] 27-9/16 [700] 42 [19.0] 9.0 15 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1228/1172 48 50 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
NAXSKS12A112AA
12,000 4,00012,000
930 1.9 0.820 15,000 4,80016,800 1,330 10,000 9,000 7,900 -- 20.5 12.9 12.4 3.3 Yes
247317388
222285349
247317388
232833
232833
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 39 [990] 27-9/16 [700] 50 [22.0] 9.0 16 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1228/1172 49 51 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
66 Nv-Series
*optional
*optional AAR-40MAAU
Optional
*optional
*optional
PAC YT53CRAU-J PAR-CT01MAU-SB
NAXDKS15A112AA
NAXSKS15A112AA
15,000 5,20015,000
1,150 1.9 0.860 18,000 5,00021,600 1,440 11,700 11,900 10,000 -- 19.0 13.0 11.4 3.6 Yes
353441529
317396476
353441529
303437
303437
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 39 [990] 27-9/16 [700] 54 [24.0] 10.0 18 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1243/1229 49 51 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
NAXDKS18A112AA
NAXSKS18A112AA
18,000 6,10018,000
1,310 2.8 0.820 21,600 8,10025,600 1,580 13,900 13,100 12,000 -- 22.0 13.7 13.1 4.0 Yes
423529635
381476572
423529635
303438
303438
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 46-7/8 [1190] 27-9/16 [700] 62 [28.0] 14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 127 [58] 1691/1691 54 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
DKS Model
Indoor Unit
Outdoor Unit
Remote Controller
-STAT
Optional
NAXDKS(09/12/15/18)A112A*
NAXSKH(09/12/15/18)A112A*
Optional
VAQ Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
Heat Caulking Fixing Method
Indoor Unit
NAXDKS09A112AA
NAXDKS12A112AA
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKH09A112AA
9,000 4,5009,000
690 1.7 0.790 12,500 8,10013,300 1,300 8,700 12,500 12,500 -- 17.3 13.0 9.8 2.8 Yes
194247317
174222285
194247317
232630
232630
0.020.060.140.2 2121/32 [550] 7-7/8 [200] 31-1/8 [790] 27-9/16 [700] 42 [19.0] 14.0 24 34-5/8 [880] 38-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXSKH12A112AA
12,000 5,21012,000
920 2.5 0.760 15,000 7,70018,000 1,120 9,000 15,000 15,000 -- 19.0 13.0 10.2 3.9 Yes
247317388
222285349
247317388
232833
232833
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 39 [990] 27-9/16 [700] 50 [22.0] 14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
*optional
*optional AAR-40MAAU
Optional
*optional
*optional
PAC YT53CRAU-J PAR-CT01MAU-SB
NAXDKS15A112AA
NAXSKH15A112AA
15,000 9,00015,000
1,200 2.8 0.800 18,000 8,60022,400 1,920 12,200 18,000 18,000 -- 17.3 12.5 9.5 2.7 Yes
353441529
317396476
353441529
303437
303437
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 39 [990] 27-9/16 [700] 54 [24.0] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
NAXDKS18A112AA
NAXSKH18A112AA
18,000 9,20018,000
1,370 2.0 0.870 21,600 8,80028,000 1,840 14,200 21,600 21,600 -- 19.1 13.1 10.9 3.4 Yes
423529635
381476572
423529635
303438
303438
0.020.060.140.2 21-21/32 [550] 7-7/8 [200] 46-7/8 [1190] 27-9/16 [700] 62 [28.0] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Nv-Series 67
PEAD Model
Mid Static Horizontal-ducted Indoor Unit
The thin, ceiling-concealed indoor units of this model are the perfect answer for the air conditioning needs of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, reducing electricity consumption and contributing to a further reduction in operating cost.
Compact Indoor Units
External Static Pressure
The height is only 9-7/8" for all sizes of this model ranging from 12 to 42 KBTU/H. Its compact size allows for the unit installations in low ceilings with minimal clearance space.
External static pressure conversion can be set up to five settings. Capable of being set to a maximum of 0.60 In.W.G., units are applicable to a wide range of building types.
Model
12
18
24
30
36
42
PEAD-AA7
0.14-0.20-0.28-0.40-0.60 In. W.G.
High Energy Efficiency
SEER
21.1
19.9
AA5 Series
(previous model)
19.6 19.1
AA7 Series
(current model)
19.1
16.0
16.1
15.5
15.0
13.8
HSPF
10.8
AA5 Series
(previous model)
10.8
AA7 Series
(current model)
10.2
10.2 10.2
9.4
9.9 9.8
10.0 10.0
12
18
24
30
36
42
12
18
24
30
36
42
Built-in Drain Lift Mechanism
All sizes feature a built-in drain lift mechanism for the removal of condensate. A fail-safe mechanism recognizes a high liquid level in the condensate pan and turns off the indoor fan and the outdoor unit compressor to prevent overflow.
68 Nv-Series
PEAD Model
Indoor Unit
Outdoor Unit
Remote Controller
-STAT
Optional
PEAD-A09/12/15/18/24/30/36AA7
NAXSKS(09/12/15)A112A* NAXSKS(18/24/30/36)A112A*
*optional
*optional AAR-40MAAU
Optional
VAQ Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
Heat Caulking Fixing Method
Indoor Unit
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry Wet Dry Cooling Heating
External Static Pressure
Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
NAXSKS09A112AA
9,000 4,3009,000
720 0.8 0.900 12,000 3,96013,000 900 7,600 7,600 6,100 -- 19.7 12.5 12.6 3.9 Yes
282318353
NAXSKS12A112AA
12,000 4,40012,000
930 1.1 0.900 15,000 4,80017,000 1,160 9,900 9,900 7,900 -- 20.5 12.9 13.0 3.7 Yes
353424494
NAXSKS15A112AA
15,000 5,50015,000
1,150 1.3 0.900 18,000 4,90021,500 1,350 11,300 11,300 10,100 -- 19.2 13.0 11.6 3.9 Yes
424512600
254286318
318382445
382461540
282318353
353424494
424512600
242628
283034
303337
242628
0.140.20.28 0.40.6
279/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
58 [26] 9.0 15
21-5/8 [550] 31-1/2 [800] 11-1/4 [285]
81 [37] 1228/1172
48 50 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
283034
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
58 [26] 9.0 16
21-5/8 [550] 31-1/2 [800] 11-1/4 [285]
81 [37] 1228/1172
49 51 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
303337
0.140.20.28 0.40.6
279/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
62 [28] 10.0 18 21-5/8 [550] 31-1/2 [800] 11-1/4 [285] 81 [37] 1243/1229 49 51 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Optional
PEAD-A18AA7
NAXSKS18A112AA
18,000 6,20018,000
1,270 3.2 0.800 21,600 8,12025,600 1,600 14,000 14,000 12,000 -- 19.8 14.1 12.9 3.9 Yes
424512600
382461540
424512600
303337
303337
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
62 [28] 14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 127 [58] 1691/1691 54 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 15 R410A 14 to 115 [-10.0 to 46.0] -4 to -75 [-20.0 to 24.0]
*optional
*optional
PAC YT53CRAU-J PAR-CT01MAU-SB
PEAD-A24AA7
NAXSKS24A112AA
24,000 12,00024,000
1,920 4.9 0.770 25,000 14,40028,000 1,990 15,000 15,000 -- -- 18.0 12.5 11.2 3.6 Yes
512635741
PEAD-A30AA7
NAXSKS30A112AA
27,000 13,20027,000
2,160 3.9 0.840 30,000 15,86033,000 2,410 22,400 22,400 -- -- 18.0 12.5 12.6 3.6 Yes
618742883
PEAD-A36AA7
NAXSKS36A112AA
33,000 14,00033,000
3,510 4.8 0.840 33,400 14,75036,000 3,170 23,000 23,100 -- -- 16.0 9.4 11.6 3.0 No
84710241201
461572667
556668795
7629221081
512635741
618742883 84710241201
303337
303439
333842
303337
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732]
69 [31] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [59] 2020/1930 55 55 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
303439
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732]
69 [31] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [59] 2020/1930 55 55 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
333842
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 55-1/8 [1400] 28-7/8 [732]
86 [39] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [59] 2020/1930 55 55 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 100 [30] 100 [30] 208/230, 1, 60 20 R410A 14 to 115 [-10.0 to 46.0] 14 to -75 [-10.0 to 24.0]
Nv-Series 69
PEAD Model Indoor Unit
Outdoor Unit
Remote Controller
PEAD-A09/12/15/18AA7
NAXSKH(09/12/15/18)A112A* NAXSKH24A112A* NAXSKH(30/36)A112A*
*optional
*optional AAR-40MAAU
AT
al
Optional
Indoor Unit
VAQ Optional
Optional
Optional
USNAP
Optional
Optional
Optional
T-STAT
Optional
Heat Caulking Fixing Method
Optional
*optional
*optional
PAC YT53CRAU-J PAR-CT01MAU-SB
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max 5
Dry Wet Dry Cooling Heating
External Static Pressure
Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor 6 Recommended Breaker Size
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling 7 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
NAXSKH09A112AA
9,000 5,0009,000
650 1.4 0.820 12,000 8,20014,000 910 6,800 12,000 12,000 -- 17.8 13.8 10.8 3.8 Yes
282318353
NAXSKH12A112AA
12,000 5,77012,000
850 1.9 0.820 15,000 7,90018,000 1,100 9,000 15,000 15,000 -- 19.3 14.1 11.0 3.9 Yes
353424494
NAXSKH15A112AA
15,000 9,60015,000
1,190 2.4 0.820 18,000 8,80023,000 1,710 11,700 18,000 18,000 -- 18.3 12.6 9.9 3.0 Yes
424512600
NAXSKH18A112AA
18,000 9,32018,000
1,400 3.6 0.780 21,600 8,80028,000 1,890 14,200 21,600 21,600 -- 18.9 12.8 10.8 3.3 Yes
424512600
NAXSKH24A112AA
24,000 10,00024,000
2,080 6.9 0.680 25,000 10,00028,000 1,920 18,000 25,000 25,000 -- 15.0 10.3 9.0 3.8 No
512635741
NAXSKH30A112AA
30,000 14,60030,000
2,350 6.5 0.760 32,000 14,70034,000 2,740 21,000 32,000 32,000 -- 15.0 12.5 9.0 3.4 Yes
618742883
NAXSKH36A112AA
33,000 15,60033,000
2,490 3.6 0.880 37,000 17,40040,000 2,940 25,400 37,000 37,000 -- 15.0 12.5 9.0 3.7 Yes
84710241201
254286318
318382445
382461540
382461540
461572667
556668795
7629221081
282318353
353424494
424512600
424512600
512635741
618742883 84710241201
242628
283034
303337
303337
303337
303439
333842
242628
0.140.20.28 0.40.6
279/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
58 [26] 14.0 24 34-5/8 [880] 38-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
283034
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
58 [26] 14.0 24 34-5/8 [880] 33-1/16 [840] 13 [330] 129 [58.5] 1,691/1,691 54 55 3/8 [9.52] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 15 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
303337
0.140.20.28 0.40.6
279/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
62 [28] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 65 [20] 40 [12] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
303337
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 35-7/16 [900] 28-7/8 [732]
62 [28] 17.0 31 34-5/8 [880] 33-1/16 [840] 13 [330] 131 [59.5] 2,020/1,930 55 55 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 50 [15] 208/230, 1, 60 20 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
303337
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732]
69 [31] 17.0 27 37-1/8 [943] 37-13/32 [950] 14-3/16 [360] 190 [86] 800/800 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
303439
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732]
69 [31] 24.0 40 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 590/680 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
333842
0.140.20.28 0.40.6
27-9/16 [700] 9-7/8 [250] 55-1/8 [1400] 28-7/8 [732]
86 [39] 26.0 42 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 590/680 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 17 DB, 15 WB
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
Conditions
5Heating at -5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // -5 DB, -6 WB
6Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
70 Nv-Series
P-Series
Our professional line of products provide solutions for residential and commercial single-zone applications.
P-Series Product Lineup
The P-Series lineup includes a selection of six indoor units and three categories of outdoor units. You can easily build a system that best matches the application's heating and cooling needs.
Step 1: Select your Indoor Unit
Wall-mounted PKA-HA
Four-way Ceiling Cassette PLA
Wall-mounted PKA-KA
Step 2: Select your Outdoor Unit
Choose from Cooling Only, Heat Pump, or Hyper-heating models.
Cooling Only
Horizontal-ducted PEAD
Multi-position Air Handler PVA
Ceiling-suspended PCA
PUY-A12NKA7
Heat Pump
PUY-A18NKA7
PUY-A24NHA7
PUY-A30NHA7
PUY-A36NKA7
PUY-A42NKA7
PUZ-A12NKA7
PUZ-A18NKA7
PUZ-A24NHA7
Hyper-Heating INVERTER® Heat Pump
PUZ-A30NHA7
PUZ-A36NKA7
PUZ-A42NKA7
PUZ-HA24NHA1
PUZ-HA30NKA
PUZ-HA36NKA
PUZ-HA42NKA1
P-Series 73
P-Series
Industry-leading energy efficiency has been achieved by optimizing a newly designed compressor and using the latest energy-saving technologies. All compressors offer high performance due to advanced variable-speed INVERTER-drive technology, which varies the compressor speed dynamically to adapt to the room's conditioning requirements.
Industry Leading Energy Efficiency
Industry-leading energy efficiency has been achieved through optimization of a newly designed compressor and the use of the latest energy-saving technologies. All compressors offer high performance due to advanced variable-speed INVERTER-drive technology, which varies the compressor speed dynamically to continuously adapt to the conditioning requirements of the room.
28
27.0
SEER
26
24.6
24.2
24
22.8
21.8
22
21.0
20
18
16
14
12
10 PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
14
13
12.8
HSPF
12
11.6
11.2 11.0
11
10.4
10 9.3
9
8
7 PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
Advanced Energy-Saving Technology
Highly efficient fan for outdoor unit
Fan opening of 21-3/4" (A36-42)
The opening for the fan in the outdoor unit is
21-3/4" in diameter. Exchanging heat more efficiently
contributes to increased energy-savings and lower
noise levels.
The opening for the fan
The opening fi2on1r-t3th/h4e"eoiufnatddnoiaomr eutneirt. is
in the outdoor unit is
21-3/4" in diameter. The opening for the fan
in the outdoor unit is 21-3/4" in diameter.
Improved fan (A36-42) A newly designed fan increases airflow capacity and reduces operation noise.
Fan rear edge
Fan rear edge
Fan rear edge
Highly efficient heat exchanger
High-density heat exchanger (A36-42)
The A36-42 units use a 5/16" diameter pipe. The high-density heat exchanger contributes to efficient heat exchange and reduces the amount of refrigerant used, which benefits the environment.
2 lines, 64 columns (2A(Al3in63e-s46,2-6)442c)olumns
74 P-Series
2 lines, 64 columns (A36-42)
Cooling Only
PUY Model High Reliability and Performance in Low Ambient Conditions
PrTceoPhvneriteoPrvouUilsoYlinumMgsootmdhdeeeolldfc(aPeonUlos(YlPpi-nUAegeY**do-NA,nK*tl*AyhNe/uNKnPHAiUAt/NY6pH)rcoAav6ni)doefsfecrosotlainbgleaclol oyelianrgroopuenrda,teiovnendoinwcnoltdoc-l4im0°aFt.e low ambient conditions. By
11*15Op1°tLi5oFon°awltAFoirA1Ptromo4te°1bctFi4ioen°(nG4Futi6dCe(°/4WoC6iond°ltBionCaffglet1ioOs 0npe°ee1deCr0da)w°thiCeon )nambRieantntegmeperature
is
under
23° F.
High
Capacity
At
Low
Ambient
Condition
NeNwewPmreovmidoouesdlm(ePoldUe(YPl (-UPAUY*Y*--ANA*K**N*AKNA/KN/NAHHA/AN67)H)A7)
115° F to 14° F (46° C to 10° C)
11151° 5F°tFo to40°4F0°(4F6(°4C6°toCt4o0°4C0)° C)
New model (PUY-A**NKA/NHA7)
1151°1F5° F 115° F to 40° F (46° C to 40° C) 14° F14° F 40° F40° F
PUZ-A12NKA7 PUZ-A18NKA7 PUZ-A24NHA7 PUZ-A30NHA7 PUZ-A36NKA7
Piping
Length (ft)
Height (ft)
100
100
100
100
165
100
165
100
165
100
115° F
14° F
40° F
PUZ-A42NKA7
165
100
Quick Auto Restart After Power Failure
In case of power failures, auto restart time shortens from 180 seconds to 60 seconds. The unit starts back up in the same operation mode it ran when the power failure occurred.
Backup Rotation Function
The two units operate alternately to maintain equal runtimes and equivalent wear, extending their life. In this configuration, if one unit experiences issues, the other unit continues to operate.
PrePvrieoPvuriesovuimosuosmdmeooldd(ePelUl(P(YPU-YUA-AY***-N*ANKK**AAN//NNKHHAAA6/N)6H) A6) 18108s0e1c8s0oenscedocsnonddss
*Can only be used with AAR-40MAAU controller
ON
ON OONN
ON
ON
UNIT 1
UNIT 1UNIT 1OFF
OFF OOFFFF
OFF OFF
NeNwe6Nwm0eowmsdemoceoodlnd(edePsllU((PYPU-UAYY-*A*-*NA*NK*K*ANA//KNNHAHA/A7N)7H) A7)
6 06s0ecsoencodns ds
UNIT 2
ON
UNIT 2
OFF
UNIT
2
OFF
ON
OFF
OFF
ON
ON
OFF OFF
ON
ON
Continuous Operation
A control algorithm allows for stable continuous operation to meet cooling requirements all year round. The unit will quickly restart with the same operation mode as before the power failure.
P-Series 75
Heat Pump
PUZ Model Quiet Operation
Sound Level
PUZ Series outdoor unit*
*PUZ-A12/18 cooling mode
30 dB(A)
40 dB(A) Library interior
44 dB(A)
40 dB(A)
50 dB(A)
60 dB(A)
65-75 dB(A)
Quiet passenger Traditional heat-pump
80 dB(A)
car interior (40km/h) outdoor unit
Subway car interior
60 dB(A)
70 dB(A)
80 dB(A)
90 dB(A)
Wide Operation Range
PUZ Series outdoor unit*
HSPF SEER
P-Series
heat
pumps
offer
a
wide
tempera*tPuUZr-eA12/18
cooling 25
mode
27.0
Cooling24.6 0° F*124t.2o 115° F
(46° C to 18.8° C)
15
operation range, easily fitting many climate design
conditions.
40 dB(A)
20
22.8
12Q.8uie6Ht0pedaBas(stAeinn) gger
Tradit6io5n-7a5l-hd4eB°a(AFt-)ptuom7p0°
F
21.8
(-8200d°B(CA)to211.09°
C1)3*2
Library interior
car interior (40km/h) outdoor unit
Subway car interior
Flexible Installation
44 dB(A)
15
30 dB(A)
Long Piping Length
40 dB(A)
50 dB(A)
11.6
*1 6*02
In c1a1s.e0that the a1ir1p.2rotection guide
baffle is not installed, the minimum
dAB24(A/3)0/36/42
70 dB(A)
wind baffle is installed. (In case the wind temperat1u0re.4will be 23° F (5° C) DB) 11
80 dB(A) 9.3
90 dB(A)
10
9
Long piping lengths enable system design flexibility
Energy Efficiency
HSPF SEER
for applications such as apartment buildings, churc5hes, PLA-A12EA7
PLA-A1287E.0A7 PLA-A24EA7
PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
7
or strip malls.
25
24.6
24.2
15
22.8
Piping
20
12.8
21.8 21.0 13
PUZ-A12NKA7 PUZ-A18NKA7
Length (ft) 100 100
Height (ft)
15 100
100
10
11.0
11.2
11.6
11
10.4
9.3
9
PUZ-A24NHA7
165
PUZ-A30NHA7
165
100
5
7
100
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
PUZ-A36NKA7
165
100
PUZ-A42NKA7
165
100
76 P-Series
Hyper-Heating INVERTER®
PUZ-HA Model Improved Heating Performance
Our unique Flash Injection circuit achieves remarkably high heating performance. This technology has resulted in excellent heating capacity ratings in outdoor temperatures as low as 5° F. The guaranteed heating operation range of the heating mode extends to -13° F.
Heating capacity (Btu/h)
38,000 30,000
Approximately 30% higher than model one size larger (example of 30,000 BTUH model)
PUZ-A36
PUZ-HA36 PUZ-HA30
Guaranteed heating operation range is extended to -13° F ambient temperature
-4oF
PUZ Series
22,000
PUZ-A30
-13oF
PUZ-HA Series
-13oF
- 4oF
5oF
19oF
32oF
Outdoor-air Temperature
-13oF
-4oF
5oF
14oF
23oF
32oF
Enhanced Comfort
The Flash Injection circuit improves start-up and recovery from the defrosting operation. The defrost operation control improves the required defrost frequency. These features enable the temperature to reach the set point fast and contribute to maintaining the desired setting.
HeaHtienatging capcaaciptayci(tByT(UB/Th)U/h)
HeaHtienatging capcaaciptayci(tByT(UB/Th)U/h)
Quick Start-up
QOpueicrkatSiotnaratt-u36p° F outdoor temperature
Operation at 36H°2Fi roisuetsdqouoicrktlye,mperature
38,000
H1123i °riFseins 1q0umiciknly, 113° F in 10min
38,000
10min
Discharged air temperature reaches 122o F
D(iinssctahbalercgoendditiaonir) Stabtleempera(intustraeblerceoandcihtioens) 122o F
Stable 19min
30,000 30,000
10min
19min
Normal INV:
1N1o3romFainl I1N9Vm: in
Approx. 50% faster 113o F in 19min
22,000
Approx. 50% faster
Operation at -4° F outdoor temperature
Operation at -4° F outdooHr2ti erimseps eqruaictkulrye,
38,000
1H123i °riFseins q2u0mickinly, 113° F in 20min
38,000
20min
30min
30,000
20min
30min
30,000 22,000
33% faster 33% faster
22,000
0 0
0 0
5
10
15
20
5
Oper1a0tion time1(5min) 20
Operation time (min)
22,000 0 0
10
20
30
10 Operation t2im0 e (min) 30
Operation time (min)
H2i Defrost Control and Faster Recovery from Defrost Operation Field Test Results: Office building in Asahikawa, Hokkaido, Japan
OHp2ei rDateiofrnodstatCaofnortr2o5l Jaannd. 2F0a0s5ter Recovery frOopmeraDteiofnrodsattaOfpoerr2aDtieocn. 20F0ie4ld Test Results: Office building in Asahikawa, Hokkaido, Japan
O140p°Feration data for 25 Jan. 2005
114202°°FF
Indoor outlet temp.
110242°°FF
Indoor outlet temp.
10846°°FF
6886°°FF 5608°°FF
Room temp.
5302°°FF
Room temp.
18:00 20:00 22:00 0:00
2:00
4:00
6:00
1342°°FF 1-44°°FF
18:00 20:00 22:00 0:00
2:00
4:O00utdoo6r :t0e0mp.
-2-42°°FF
Outdoor temp.
Reduced defrosting operation time
-22°F
from 4 to 3 minutes.
Reduced defrosting operation time
from 4 to 3 minutes.
O14p0°Feration data for 2 Dec. 20Ind0o4or outlet temp.
114202°°FF
Indoor outlet temp.
110242°°FF
10846°°FF
6886°°FF
Room temp.
5608°°FF
Room temp. Outdoor temp.
5302°°FF
14°F 32°F
8:00 14°F
Outdoor temp. 10:00 12:00 14:00 16:00 18:00 20:00 22:00
H8:200i De1f0r:0o0st C12o:0n0 tro14l:0m0 ain16t:0a0ine1d8:0a0 m2a0:x00imum22:0i0nterval of 1tHe52m0i pDmeeirfnaruottusetrseCsbooentftwraopelepmnroadxienimftraaointseteildnyga-4om°pFaexarainmtdiuo3mn2s°ianFt.teoruvtadlooofr 150 minutes between defrosting operations at outdoor temperatures of approximately -4° F and 32° F.
Installation example Installation example
Normal INV: 1N1o3romFailnIN30Vm: in 113o F in 30min
P-Series 77
PLA Model
Four-way Ceiling Cassette
Four-way Ceiling Cassette Lineup
The PLA Model offers an extensive lineup with capacities ranging from 12 to 42 KBTU/H.
Line-up
Model
12
18
24
30
36
42
Key Technologies for Higher Energy Efficiency
Series
3D Turbo Fan
4-way Cassette (PLA-A)
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
By optimizing the fan blade wing design using a three-dimensional shape, efficiency has been improved and operating noise reduced.
Indoor/Outdoor Unit Combinations
Four-way Cassette PLA-A EA
Power Inverter
PUY/PUZ-A12/18 PUY/PUZ-A24/30 PUY/PUZ-A36/42
PUY-HA24 PUZ-HA30/36/42
Improved Energy-Saving Performance
SEER
27.0
24.6
PLA-BA Series
(previous model)
PLA-EA Series
(current model)
24.2 22.8
21.8
21.0
14.2
14.0
14.0
14.2
14.4
HSPF
12.8
11.0 9.8
11.2 8.5
PLA-BA Series
(previous model)
PLA-EA Series
(current model)
11.6 8.7
10.4 9.3
9.3 9.3
12
18
24
30
36
42
78 P-Series
12
18
24
30
36
42
Horizontal Airflow
Draft Reduction Vane Setting
The Draft Reduction vane setting adjusts airflow direction more horizontal than the standard vane setting reducing drafts dramatically.
*The draft reduction can be set for only 1 vane. AAR-40MAAU is required for this setting.
4-, 3-, or 2- way outlet selection* 4-, 3-, or 2- way outlet selection*
*Optional parts air outlet shutter plate is required for 2- or 3- way *Ooputtiloent aslepleacrttisona.ir outlet shutter plate is required for 2- or 3- way
outlet selection.
Individual Vane Settings
An astonishing 72 unique airflow patterns are available to accommodate different room layouts. Select any combination of 2, 3, or 4 vanes to deliver air into the area. Further, personalize comfort by adjusting the vane up or down to set air direction.
Easy Installation
Setting the air direction for each outlet with Setting thewairirediremctoiotne cfoornetraoclhleor utlet with
wired remote controller Horizontal airflow Horizontal airflow
Remote controller setting Remote controller setting
Down airflow Down airflow
Fixed Fixed
Electrical Box Wiring
Product design improvements to the power supply terminal position enhance connectivity and increase ease of installation.
Previous Model (BA Model) New Model (EA Model)
Increased Space For Piping Work
The updated product design includes reversing the gas and liquid line connections to enhance piping installation. Additional piping improvements include increased space surrounding the connections, permitting a larger wrench turning radius.
Temporary Hanging Hook
The updated product design includes temporary hanging hooks, improving work efficiency during installation.
50° 70°
No Need To Remove Screws Captive screws added to the corner panel and control box make working overhead much easier.
Corner Panel
Corner Box Cover
Lightweight Decorative Panel The updated product grille is 20% lighter weight compared to the previous model.
P-Series 79
for P-Series
Detects Number Of People
The 3D i-see Sensor® detects the number of people in the room and adjusts the power accordingly. This makes automatic power-saving operation possible in places where the number of people changes frequently. Additionally, when the area is continuously unoccupied, the system switches to a more enhanced power-saving mode. Depending on the setting, it can also stop the operation.
Detects People's Position
Once a person is detected, the angle of the vane is automatically adjusted. Each vane can be independently set to Direct Airflow or Indirect Airflow according to taste.
Detects number of people
Detects the Location of Individuals
Detects position and number of people
Detects floor temperature
8 sensors
8
7
6 4 53 2 1
12 3 4 5
6
7
8
360°
Detection
8 ft. 23 ft.
3 ft.
39ft.
Room Occupancy Energy Save Mode
Floor surface *In case of a 8 ft. ceiling
Room Occupancy Energy-Saving Mode
The 3D i-see Sensor detects the number of people in the room. It then calculates the occupancy rate based on the maximum number of people in the room up to that point in time in order to save air conditioning power. When the occupancy rate is approximately 30%, air-conditioning power equivalent to 2° F during both cooling and heating operation is saved. The temperature is controlled according to the number of people.
No Occupancy Energy Save Mode No Occupancy Auto Off Mode
2° F power savings
4° F power savings
No Occupancy Energy-Saving Mode
Auto-Off
When 3D i-see Sensor detects that no one is the room, the system is switched to a preset power-saving mode.
If the room remains unoccupied for more than 60min,
*AAR-40MAAU is required for each setting
air-conditioning power equivalent to 4° F during both cooling and heating operation is saved. This contributes to
preventing waste in terms of heating and cooling.
No Occupancy Auto-Off Mode
When the room remains unoccupied for a preset period of time, the air conditioner turns off automatically, thereby providing even greater power savings. The time until operation is stopped can be set in intervals of 10 min, ranging from 60 to 180 min.
Seasonal Airflow*
When Cooling
Saves energy while keeping a comfortable effective temperature by automatically switching between ventilation and cooling. When a preset temperature is reached, the air conditioning unit switches to swing fan operation to maintain the effective temperature. This clever function contributes to keeping a comfortable coolness.
When Heating
The air conditioning unit automatically switches between circulator and heating. Wasted heat that accumulates near the ceiling is reused via circulation. When a preset temperature is reached the air conditioner switches from heating to circulator and blows air in the horizontal direction. It pushes down the warm air that has gathered near the ceiling to people's height, thereby providing smart heating.
Direct/Indirect Settings*
The horizontal airflow spreads across the ceiling. When set to Indirect Airflow uncomfortable drafty-feeling is eliminated completely.
80 P-Series
PLA Model
Model Selection
Indoor Unit
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
Outdoor Unit
Cooling Only PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
PLA-A12/18/24/30/36/42EA7 Required grille: PLP-41EAEU
Heat Pump PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
Remote Controller
Hyper-heating PUZ-HA24NH1
PUZ-HA30/36NKA
PUZ-HA42NK1
*optional AAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
P-Series 81
PLA Model
Cooling Only
Optional
Optional 60-140V/200/250
Optional
Optional
Optional Optional
Wi-Fi Interface
Optional
Optional
Indoor Unit
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
Outdoor Unit Cooling Heating Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Rated 1 Min-Max Rated 1 Pints/h
Rated Min-Max Rated Rated Max Max Max
Dry Wet Dry Cooling Heating
Max Distance
H
Dimensions
W
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
D
lbs [kg] A A H
W
D
lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
PUY-A12NKA7(-BS)
12,000 5,80012,000
730 1.2 0.890 -- -- -- -- -- -- -- 27.0 16.4 -- -- Yes
420460490530
PUY-A18NKA7(-BS)
18,000 8,00018,000
1,250 2.4 0.850 -- -- -- -- -- -- -- 24.6 14.4 -- -- Yes
420460570600
PUY-A24NHA7(-BS)
24,000 10,00024,000
1,670 3.0 0.860 -- -- -- -- -- -- -- 24.2 14.3 -- -- Yes
530640710810
380420450490 380420530560 490600670770
420460490530 420460570600 530640710810
27282930
28293132
28303336
27282930
28293132
--
33-7/16 [849] 10-5/32 // 1-9/16 [258
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 46 // 11 [21 // 5]
11.0
28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)]
--
33-7/16 [849] 10-5/32 // 1-9/16 [258
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 46 // 11 [21 // 5]
11.0
28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)]
11-3/16 [300]
11-3/16 [300]
92 [41] 1590/--
44 -- 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60 15 R410A -40 to 115 [-40.0 to 46.0] --
99 [44] 1590/--
44 -- 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60 15 R410A -40 to 115 [-40.0 to 46.0] --
28303336
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
19.0 26 37-1/8 [943]
37-13/32 [950]
13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 --
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 225 [68] 100 [30] 208/230, 1, 60
25 R410A -40 to 115 [-40.0 to 46.0]
--
Notes:
AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
PLA-A30EA7
PUY-A30NHA7(-BS)
30,000 9,00030,000
2,540 5.4 0.800 -- -- -- -- -- -- -- 22.8 11.8 -- -- No
570670780880
530630740840
570670780880
28323538
28323538
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
19.0 26 37-1/8 [943]
37-13/32 [950]
13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 --
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 225 [68] 100 [30] 208/230, 1, 60
25 R410A -40 to 115 [-40.0 to 46.0]
--
PLA-A36EA7
PLA-A42EA7
PUY-A36NKA7(-BS)
36,000 16,00036,000
2,780 4.5 0.860 -- -- -- -- -- -- -- 21.8 12.9 -- -- Yes
PUY-A42NKA7(-BS)
42,000 16,00042,000
3,590 7.9 0.790 -- -- -- -- -- -- -- 21.0 11.6 -- -- No
67085010201200 74092010601200
6308109801160 70088010201160
67085010201200 74092010601200
32374144
34384245
32374144
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
25.0 31 52-11/16 [1338]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 --
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 225 [68] 100 [30] 208/230, 1, 60
30 R410A -40 to 115 [-40.0 to 46.0]
--
34384245
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
25.0 31 52-11/16 [1338]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 --
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 225 [68] 100 [30] 208/230, 1, 60
30 R410A -40 to 115 [-40.0 to 46.0]
--
82 P-Series
PLA Model
Heat Pump
Optional PUHZ
PUHZ
Optional PUHZ
Optional
Optional
PUHZ
SUZ Optional
Optional Optional
PUHZ
Wi-Fi Interface
Optional
PUHZ Optional
PUHZ
Indoor Unit
PLA-A12EA7
PLA-A18EA7
PLA-A24EA7
Outdoor Unit Cooling Heating Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry Wet Dry Cooling Heating
Max Distance
H
Dimensions
W
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
D
lbs [kg] A A H
W
D
lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
PUZ-A12NKA7(-BS)
12,000 5,80012,000
730 1.2 0.890 14,000 5,50020,000 830 10,100 12,200 13,000 -- 27.0 16.4 12.8 4.94 Yes
420460490530
PUZ-A18NKA7(-BS)
18,000 8,00018,000
1,250 2.4 0.850 19,000 7,90023,000 1,300 11,000 13,500 12,000 -- 24.6 14.4 11.0 4.28 Yes
420460570600
PUZ-A24NHA7(-BS)
24,000 10,00024,000
1,670 3.0 0.860 26,000 9,00029,000 1,750 14,900 17,400 13,000 -- 24.2 14.3 11.2 4.35 Yes
530640710810
380420450490 380420530560 490600670770
420460490530 420460570600 530640710810
27282930
28293132
28303336
27282930
28293132
--
33-7/16 [849] 10-5/32 // 1-9/16 [258
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 46 // 11 [21 // 5]
11.0
28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)]
--
33-7/16 [849] 10-5/32 // 1-9/16 [258
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 46 // 11 [21 // 5]
11.0
28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)]
11-3/16 [300]
11-3/16 [300]
93 [42] 1590/1590
44 46 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 100 [30] 208/230, 1, 60 15 R410A 0 to 115 [-18.0 to 46.0] 12 to 70 [-11.0 to 21.0]
100 [45] 1590/1590
44 46 1/2 [12.7] 1/4 [6.35] 1-1/4 [32] 100 [30] 100 [30] 208/230, 1, 60 15 R410A 0 to 115 [-18.0 to 46.0] 12 to 70 [-11.0 to 21.0]
28303336
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
19.0 26 37-1/8 [943]
37-13/32 [950]
13 (+1-3/16) [330 (+30)] 153 [69]
1940/1940 47 48
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60
25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
Conditions
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
PLA-A30EA7
PUZ-A30NHA7(-BS)
30,000 9,00030,000
2,540 5.4 0.800 32,000 9,00033,000 2,400 18,100 20,800 16,800 -- 22.8 11.8 11.6 3.9 No
570670780880
530630740840
570670780880
28323538
28323538
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
19.0 26 37-1/8 [943]
37-13/32 [950]
13 (+1-3/16) [330 (+30)] 153 [69]
1940/1940 47 48
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60
25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
PLA-A36EA7
PLA-A42EA7
PUZ-A36NKA7(-BS)
36,000 16,00036,000
2,780 4.5 0.860 38,000 18,00042,000 2,540 22,000 25,500 21,600 -- 21.8 12.9 10.4 4.38 Yes
PUZ-A42NKA7(-BS)
42,000 16,00042,000
3,590 7.9 0.790 45,000 18,00048,000 3,290 28,000 30,800 26,900 -- 21.0 11.6 9.3 4.0 No
67085010201200 74092010601200
6308109801160 70088010201160
67085010201200 74092010601200
32374144
34384245
32374144
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
25.0 31 52-11/16 [1338]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 214 [97]
3880/3880 52 53
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60
30 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
34384245
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298
// 40] 33-1/16 // 37-13/32
[840 // 950] 33-1/16 // 37-13/32
[840 // 950] 56 // 11 [25 // 5]
25.0 31 52-11/16 [1338]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 214 [97]
3880/3880 52 53
5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60
30 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
P-Series 83
PLA Model
Hyper-heating
Optional
Optional 60-140V/200/250
Optional
Optional
Optional Optional
Wi-Fi Interface
Optional
Optional
Indoor Unit Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
Conditions
4Heating at 5°F (Indoor // Outdoor)
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
PLA-A24EA7
PUZ-HA24NHA1
24,000 10,00024,000
1,710 3.0 0.860 26,000 10,00028,000 1,700 17,300 26,000 26,000 -- 21.5 14.0 11.3 4.5 Yes
530640710810
490600670770
530640710810
28303336
28303336
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840 // 950] 33-1/16 // 37-13/32 [840 // 950] 56 // 11 [25 // 5]
17.0 27 37-1/8 [943] 37-13/32 [950] 14-3/16 [360] 190 [86] 1940/1940 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PLA-A30EA7
PUZ-HA30NKA
30,000 14,60030,000
2,120 5.4 0.800 32,000 14,20034,000 2,260 20,600 32,000 32,000 -- 20.2 14.1 9.8 4.1 Yes
570670780880
530630740840
570670780880
28323538
28323538
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840 // 950] 33-1/16 // 37-13/32 [840 // 950] 56 // 11 [25 // 5]
24.0 40 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
°F
80 DB, 67 WB // 95 DB, 75 WB
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
°F
70 DB, 60 WB // 5 DB, 4 WB
PLA-A36EA7
PUZ-HA36NKA
36,000 14,80036,000
2,750 5.5 0.830 38,000 16,70040,000 2,650 24,200 38,000 38,000 -- 20.0 13.0 10.4 4.2 Yes
67085010201200
6308109801160
67085010201200
32374144
32374144
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840 // 950] 33-1/16 // 37-13/32 [840 // 950] 56 // 11 [25 // 5]
26.0 42 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PLA-A42EA7
PUZ-HA42NKA1
42,000 18,80042,000
3,920 4.5 0.880 48,000 17,00054,000 4,210 40,500 48,000 48,000 -- 16.3 10.7 9.8 3.3 No
74092010601200
70088010201160
74092010601200
34384245
34384245
-- 33-7/16 [849] 11-3/4 // 1-9/16 [298 // 40] 33-1/16 // 37-13/32 [840 // 950] 33-1/16 // 37-13/32 [840 // 950] 56 // 11 [25 // 5]
36.0 44 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 283 [128] 3319/3319 49 51 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 40 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
84 P-Series
PKA Model
Wall-mounted Indoor Unit
Flat Panel & Pure White Finish
A flat panel design and pure white color that pairs with any interior.
Flat panel is easy to clean
PKA-A HA7
PKA-A KA7
Compact Indoor Units
The updated product design boasts a significant size reduction compared to the previous model.
PKA-A12/18HA7 *REDUCED 3-5/8"
PKA-A24/30KA7
*REDUCED 9-1/16"
PKA-A36KA7
*REDUCED 20-1/16"
*Compared to PKA-A12/18GA previous model
*Compared to PKA-A24/30FA previous model
*Compared to PKA-A36FA previous model
Energy Saving Performance
When contrasted with the previous model's performance, SEER and HSPF efficiencies improved, realizing industry-leading energy-saving features.
SEER
20.8
18.5 15.3
HA6/KA6 Series
(previous model)
21.4
HA7/KA7 Series
(current model)
19.8 18.8
17.0 15.5 14.0
HSPF
10.2
10.2 9.5
HA6/KA6 Series
(previous model)
11.0 10.8
HA7/KA7 Series
(current model)
9.9 8.9
9.3 9.2
12
18
24
30
36
12
18
24
30
36
86 P-Series
PKA Model
Model Selection
Indoor Unit
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
Outdoor Unit
Cooling Only PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36NKA7
PKA-A12/18HA7 PKA-A24/30/36KA7
Heat Pump PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36NKA7
Remote Controller
Hyper-heating
PUZ-HA24NH1
PUZ-HA30/36NKA
*optional AAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
P-Series 87
PKA Model
Optional
Cooling Only
Wi-Fi Interface
Optional
Optional
Optional
Optional
Indoor Unit
PKA-A12HA7
PKA-A18HA7
PKA-A24KA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated Min-Max Rated Rated Max Max Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM
PUY-A12NKA7(-BS)
12,000 5,80012,000
1,000 2.0 0.810 -- -- -- -- -- -- -- 20.8 12.0 -- -- No
320370425
PUY-A18NKA7(-BS)
18,000 8,00018,000
1,820 5.2 0.680 -- -- -- -- -- -- -- 18.5 9.9 -- -- No
320370425
PUY-A24NHA7(-BS)
24,000 10,00024,000
1,960 5.0 0.770 -- -- -- -- -- -- -- 21.4 12.2 -- -- No
635705775
CFM
290335380
290335380
570635700
CFM
320370425
320370425
635705775
dB(A)
364043
364043
394245
dB(A)
364043
364043
394245
In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
--
--
--
--
11-5/8 [295]
11-5/8 [295]
35-3/8 [898]
35-3/8 [898]
9-13/16 [249]
9-13/16 [249]
29 [13]
29 [13]
11.0
11.0
28
28
24-13/16 [630]
24-13/16 [630]
31-13/16 (+7/16) [809 (+62)] 31-13/16 (+7/16) [809 (+62)]
11-3/16 [300]
11-3/16 [300]
92 [41]
99 [44]
1590/--
1590/--
44
44
--
--
1/2 [12.7]
1/2 [12.7]
1/4 [6.35]
1/4 [6.35]
5/8 [16]
5/8 [16]
165 [50]
165 [50]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
15
15
R410A
R410A
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
--
--
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52] 5/8 [16] 225 [68] 100 [30] 208/230, 1, 60 25 R410A -40 to 115 [-40.0 to 46.0] --
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
60-140V/200/250
Optional
PKA-A30KA7
PUY-A30NHA7(-BS) 30,000
9,00030,000 3,150 8.1 0.700 -- -- -- -- -- -- -- 19.8 9.5 -- -- No
635705775
570635700
635705775
394245
394245
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52] 5/8 [16] 225 [68] 100 [30] 208/230, 1, 60 25 R410A -40 to 115 [-40.0 to 46.0] --
Optional
Optional
Optional
PKA-A36KA7
PUY-A36NKA7(-BS)
36,000 16,00036,000
3,330 9.7 0.700 -- -- -- -- -- -- -- 18.8 10.8 -- -- No
705810920
635730830
705810920
434649
434649
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 -- 5/8 [15.88] 3/8 [9.52] 5/8 [16] 225 [68] 100 [30] 208/230, 1, 60 30 R410A -40 to 115 [-40.0 to 46.0] --
88 P-Series
PKA Model
Optional
Optional
Optional
Optional
Optional
Optional
Wi-Fi Interface
Optional
Heat Pump
Optional
Optional
Indoor Unit
PKA-A12HA7
PKA-A18HA7
PKA-A24KA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM
PUZ-A12NKA7(-BS)
12,000 5,80012,000
1,000 2.0 0.810 14,000 5,50018,000 950 9,200 11,100 10,600 -- 20.8 12.0 10.2 4.31 No
320370425
PUZ-A18NKA7(-BS)
18,000 8,00018,000
1,820 5.2 0.680 19,000 7,70022,000 1,300 11,300 13,900 11,800 -- 18.5 9.9 10.2 4.28 No
320370425
PUZ-A24NHA7(-BS)
24,000 10,00024,000
1,960 5.0 0.770 26,000 9,00028,000 1,750 15,700 18,300 15,200 -- 21.4 12.2 11.0 4.35 No
635705775
CFM
290335380
290335380
570635700
CFM
320370425
320370425
635705775
dB(A)
364043
364043
394245
dB(A)
364043
364043
394245
In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
--
--
--
--
11-5/8 [295]
11-5/8 [295]
35-3/8 [898]
35-3/8 [898]
9-13/16 [249]
9-13/16 [249]
29 [13]
29 [13]
11.0
11.0
28
28
24-13/16 [630]
24-13/16 [630]
31-13/16 (+7/16) [809 (+62)] 31-13/16 (+7/16) [809 (+62)]
11-3/16 [300]
11-3/16 [300]
93 [42]
100 [45]
1590/1590
1590/1590
44
44
46
46
1/2 [12.7]
1/2 [12.7]
1/4 [6.35]
1/4 [6.35]
5/8 [16]
5/8 [16]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
15
15
R410A
R410A
0 to 115 [-18.0 to 46.0]
12 to 70 [-11.0 to 21.0]
0 to 115 [-18.0 to 46.0]
12 to 70 [-11.0 to 21.0]
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52] 5/8 [16] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
Conditions
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
PKA-A30KA7
PUZ-A30NHA7(-BS)
30,000 9,00030,000
3,150 8.1 0.700 32,000 8,90034,000 2,460 18,300 21,000 -- -- 19.8 9.5 9.9 3.81 No
635705775
570635700
635705775
394245
394245
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52] 5/8 [16] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
PKA-A36KA7
PUZ-A36NKA7(-BS)
36,000 16,00036,000
3,330 9.7 0.700 38,000 18,20040,000 2,460 22,400 25,900 -- -- 18.8 10.8 9.2 4.52 No
705810920
635730830
705810920
434649
434649
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 214 [97] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 5/8 [16] 165 [50] 100 [30] 208/230, 1, 60 30 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
P-Series 89
PKA Model
Optional
Hyper-heating
Wi-Fi Interface
Optional
Indoor Unit Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
Conditions
4Heating at 5°F (Indoor // Outdoor)
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
Optional
Optional
Optional
PKA-A24KA7
PUZ-HA24NHA1
24,000 10,00024,000
1,900 5.0 0.770 26,000 10,00028,000 1,920 17,200 26,000 26,000 -- 19.5 12.65 10.6 3.96 Yes
635705775
570635700
635705775
394245
394245
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 17.0 27 37-1/8 [943] 37-13/32 [950] 14-3/16 [360] 190 [86] 1940/1940 52 53 5/8 [15.88] 3/8 [9.52] 5/8 [16] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
°F
80 DB, 67 WB // 95 DB, 75 WB
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
°F
70 DB, 60 WB // 5 DB, 4 WB
PKA-A30KA7
PUZ-HA30NKA
30,000 14,60030,000
2,330 7.5 0.720 32,000 14,60034,000 2,770 21,300 32,000 32,000 -- 18.5 12.8 9.6 3.38 Yes
635705775
570635700
635705775
394245
394245
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 24.0 40 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 5/8 [16] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
60-140V/200/250 Optional
Optional
Optional
Optional
PKA-A36KA7
PUZ-HA36NKA
33,600 14,70036,000
2,700 9.3 0.690 38,000 14,90040,000 3,340 25,400 38,000 38,000 -- 18.5 11.6 10.0 3.33 No
705810920
635730830
705810920
434649
434649
-- -- 14-3/8 [365] 46-1/16 [1170] 11-5/8 [295] 46 [21] 26.0 42 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 5/8 [16] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
90 P-Series
PVA Model
Multi-position Air Handler
Multi-position Installation Options
The PVA Model air handler is Multi-positional* offering up, down, left, or right airflow options, making it ideal for tight and unique spaces. (*CMA accessory recommended for downflow applications.)
High Energy Efficiency
The PVA Model has high SEER ratings and is highly energy efficient compared to outdated unitary air conditioners.
21.4
SEER
20.2
20.5
20.5
19.0
19.3
13.07
Average SEER for unitary air conditioners sold in 2006.
PVA-A12 PVA-A18 PVA-A24 PVA-A30 PVA-A36 PVA-A42
Interlocking Function
The PVA Model has an output terminal which allows it to interlock with other appliances such as humidifiers and dehumidifiers.
Thermostat Control
Using the Thermostat Interface (PAC-US444CN-1), the user can replace their unitary air conditioner without changing the thermostat.
92 P-Series
PVA Model
Model Selection
Indoor Unit
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
Outdoor Unit
Cooling Only PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
Heat Pump PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
PVA-A12/18/24/30/36/42AA7
Hyper-heating
Remote Controller
PUZ-HA24NHA1
PUZ-HA30/36NKA
PUZ-HA42NKA1
*optional AAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
P-Series 93
PVA Model
Optional
Cooling Only
Wi-Fi Interface
Optional
Optional
Optional
Optional
60-140V/200/250 Optional
Optional
Optional
Optional
Indoor Unit
PVA-A12AA7
PVA-A18AA7
PVA-A24AA7
PVA-A30AA7
PVA-A36AA7
PVA-A42AA7
Outdoor Unit
Cooling Heating Efficiency
Indoor Unit
Capacity
Rated 1
BTU/H
Capacity Range
Min-Max BTU/H
Power Input
Rated 1
W
Moisture Removal
Pints/h
Sensible Heat Factor
Capacity at 47ºF
Rated
BTU/H
Capacity Range
Min-Max BTU/H
Power Input at 47ºF
Rated
W
Capacity at 17ºF
Rated Max
BTU/H BTU/H
Capacity at 5ºF
Max
BTU/H
Capacity at -5ºF
Max
BTU/H
SEER
EER
HSPF
COP
ENERGY STAR® Certified
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi)
Wet
Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi)
Dry
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Cooling
Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Heating
CFM CFM CFM dB(A) dB(A)
External Static Pressure
In. W.G.
Condensate Lift Mechanism
Max Distance In. [mm]
H
In. [mm]
Dimensions
W
In. [mm]
D
In. [mm]
Weight
lbs [kg]
MCA
A
MOCP
A
H
In. [mm]
Outdoor Unit
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Piping
Max. Length
Max. Height
Electrical
Outdoor-Indoor5 Recommended Breaker Size
Refrigerant Type
Guaranteed Temperature Operation Range
Cooling6 Heating
W
In. [mm]
D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
ºF DB [ºC DB] ºF DB [ºC DB]
PUY-A12NKA7(-BS)
12,000 4,80012,000
890 1.2 0.770 -- -- -- -- -- -- -- 21.4 13.4 -- -- Yes
280340400
--
280340400
273135
273135
0.300.50.8 --
50-1/4 [1275] 17 [432]
21-5/8 [548] 113 [51] 11.0 28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)] 11-3/16 [300]
92 [41] 1590/--
44 -- 1/2 [12.7] 1/4 [6.35] 3/4 FPT [19.05] 165 [50] 100 [30] 208/230, 1, 60 15 R410A -40 to 115 [-40.0 to 46.0]
--
PUY-A18NKA7(-BS)
18,000 7,00018,000
1,570 2.4 0.760 -- -- -- -- -- -- -- 20.2 11.4 -- -- No
515625735
PUY-A24NHA7(-BS)
24,000 10,00024,000
1,960 3.0 0.830 -- -- -- -- -- -- -- 20.5 12.2 -- -- No
613744875
PUY-A30NHA7(-BS)
30,000 10,00030,000
3,000 5.4 0.740 -- -- -- -- -- -- -- 19.0 10.0 -- -- No
613744875
PUY-A36NKA7(-BS)
36,000 14,60036,000
3,250 4.5 0.770 -- -- -- -- -- -- -- 19.3 9.8 -- -- No
7889561125
PUY-A42NKA7(-BS)
42,000 15,00042,000
4,150 7.9 0.810 -- -- -- -- -- -- -- 18.0 10.1 -- -- No
104012621485
--
--
--
--
--
515625735
613744875
613744875
7889561125
104012621485
283336
303438
303438
303438
364044
283336
303438
303438
303438
364044
0.300.50.8 --
50-1/4 [1275] 17 [432]
21-5/8 [548] 113 [51] 11.0 28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)] 11-3/16 [300]
99 [44] 1590/--
44 -- 1/2 [12.7] 1/4 [6.35] 3/4 FPT [19.05] 165 [50] 100 [30] 208/230, 1, 60 15 R410A -40 to 115 [-40.0 to 46.0]
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 19.0 26
37-1/8 [943]
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 19.0 26
37-1/8 [943]
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 25.0 31
52-11/16 [1338]
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 25.0 31
52-11/16 [1338]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 225 [68] 100 [30]
208/230, 1, 60 25
R410A -40 to 115 [-40.0 to 46.0]
13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 225 [68] 100 [30]
208/230, 1, 60 25
R410A -40 to 115 [-40.0 to 46.0]
13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 -- 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 225 [68] 100 [30]
208/230, 1, 60 30
R410A -40 to 115 [-40.0 to 46.0]
13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 -- 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 225 [68] 100 [30]
208/230, 1, 60 30
R410A -40 to 115 [-40.0 to 46.0]
--
--
--
--
--
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
94 P-Series
PVA Model
Optional
Optional
Optional
Optional
Optional
Optional
Wi-Fi Interface
Optional
Heat Pump
Optional
Optional
Indoor Unit
PVA-A12AA7
PVA-A18AA7
PVA-A24AA7
PVA-A30AA7
PVA-A36AA7
PVA-A42AA7
Outdoor Unit
Cooling Heating Efficiency
Indoor Unit
Capacity
Rated 1
BTU/H
Capacity Range
Min-Max BTU/H
Power Input
Rated 1
W
Moisture Removal
Pints/h
Sensible Heat Factor
Capacity at 47ºF
Rated 2
BTU/H
Capacity Range
Min-Max BTU/H
Power Input at 47ºF
Rated 2
W
Capacity at 17ºF
Rated 3 Max
BTU/H BTU/H
Capacity at 5ºF
Max 4
BTU/H
Capacity at -5ºF
Max
BTU/H
SEER
EER
HSPF
COP
ENERGY STAR® Certified
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi)
Wet
Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi)
Dry
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Cooling
Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Heating
CFM CFM CFM dB(A) dB(A)
External Static Pressure
In. W.G.
Condensate Lift Mechanism
Max Distance In. [mm]
H
In. [mm]
Dimensions
W
In. [mm]
D
In. [mm]
Weight
lbs [kg]
MCA
A
MOCP
A
H
In. [mm]
Outdoor Unit
Dimensions
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Piping
Max. Length
Max. Height
Electrical
Outdoor-Indoor5 Recommended Breaker Size
Refrigerant Type
Guaranteed Temperature Operation Range
Cooling6 Heating
W
In. [mm]
D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
ºF DB [ºC DB] ºF DB [ºC DB]
PUZ-A12NKA7(-BS)
12,000 4,80012,000
890 1.2 0.770 14,000 5,70019,000 1,070 9,900 12,000 -- -- 21.4 13.4 10.3 3.82 Yes
280340400
--
280340400
273135
273135
0.300.50.8 --
50-1/4 [1275] 17 [432]
21-5/8 [548] 113 [51] 11.0 28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)] 11-3/16 [300]
93 [42] 1590/1590
44 46 1/2 [12.7] 1/4 [6.35] 3/4 FPT [19.05] 100 [30] 100 [30] 208/230, 1, 60 15 R410A 0 to 115 [-18.0 to 46.0] 12 to 70 [-11.0 to 21.0]
PUZ-A18NKA7(-BS)
18,000 7,00018,000
1,570 2.4 0.760 19,000 7,70023,000 1,470 12,000 14,700 -- -- 20.2 11.4 10.4 3.78 No
515625735
PUZ-A24NHA7(-BS)
24,000 10,00024,000
1,960 3.0 0.830 26,000 12,00028,000 1,920 15,000 17,500 14,500 -- 20.5 12.2 9.3 3.96 No
613744875
PUZ-A30NHA7(-BS)
30,000 10,00030,000
3,000 5.4 0.740 32,000 12,00034,000 2,640 18,000 20,700 17,200 -- 19.0 10.0 10.0 3.54 No
613744875
PUZ-A36NKA7(-BS)
36,000 14,60036,000
3,250 4.5 0.770 38,000 17,70042,000 3,030 24,000 27,800 23,900 -- 19.3 9.8 9.5 3.66 No
7889561125
PUZ-A42NKA7(-BS)
42,000 15,00042,000
4,150 7.9 0.810 46,000 18,10048,000 3,900 28,400 31,400 26,800 -- 18.0 10.1 9.3 3.44 No
104012621485
--
--
--
--
--
515625735
613744875
613744875
7889561125
104012621485
283336
303438
303438
303438
364044
283336
0.300.50.8 --
50-1/4 [1275] 17 [432]
21-5/8 [548] 113 [51] 11.0 28
24-13/16 [630] 31-13/16 (+7/16) [809
(+62)] 11-3/16 [300]
100 [45] 1590/1590
44 46 1/2 [12.7] 1/4 [6.35] 3/4 FPT [19.05] 100 [30] 100 [30] 208/230, 1, 60 15 R410A 0 to 115 [-18.0 to 46.0] 12 to 70 [-11.0 to 21.0]
303438
303438
303438
364044
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 19.0 26
37-1/8 [943]
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 19.0 26
37-1/8 [943]
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 25.0 31
52-11/16 [1338]
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 25.0 31
52-11/16 [1338]
37-13/32 [950]
37-13/32 [950]
41-5/16 [1050]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 165 [50] 100 [30]
208/230, 1, 60 25
R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 165 [50] 100 [30]
208/230, 1, 60 25
R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
13 (+1-3/16) [330 (+30)] 214 [97] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 165 [50] 100 [30]
208/230, 1, 60 30
R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
13 (+1-3/16) [330 (+30)] 214 [97] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52]
3/4 FPT [19.05] 165 [50] 100 [30]
208/230, 1, 60 30
R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
Conditions
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
P-Series 95
PVA Model
Optional
Hyper-heating
Wi-Fi Interface
Optional
Optional
Optional
Optional
Indoor Unit
Outdoor Unit
Capacity
Rated 1
BTU/H
Capacity Range
Min-Max BTU/H
Cooling
Power Input
Rated 1
W
Moisture Removal
Pints/h
Sensible Heat Factor
Capacity at 47ºF
Rated 2
BTU/H
Capacity Range
Min-Max BTU/H
Power Input at 47ºF
Rated 2
W
Heating
Capacity at 17ºF
Rated 3 Max
BTU/H BTU/H
Capacity at 5ºF
Max 4
BTU/H
Capacity at -5ºF
Max
BTU/H
SEER
EER
Efficiency
HSPF
COP
ENERGY STAR® Certified
Indoor Unit
Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi)
Dry
Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi)
Wet
Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi)
Dry
Sound Pressure Level (Quiet-Lo-Med-Hi-SHi)
Cooling
Sound Pressure Level (Quiet-LoMed-Hi-SHi)
Heating
CFM CFM CFM dB(A) dB(A)
External Static Pressure
In. W.G.
Condensate Lift Mechanism
Max Distance In. [mm]
H
In. [mm]
Dimensions
W
In. [mm]
D
In. [mm]
Weight
lbs [kg]
MCA
A
MOCP
A
H
In. [mm]
Dimensions
W
In. [mm]
Outdoor Unit
D
In. [mm]
Weight
lbs [kg]
Air Flow Rate (Cooling/Heating) CFM
Sound Pressure Level
Cooling Heating
dB(A) dB(A)
Gas (O.D.) In. [mm]
Diameter
Liquid (O.D) In. [mm]
Piping
Indoor Drain In. [mm]
Max. Length
ft [m]
Max. Height
ft [m]
Electrical
Outdoor-Indoor5 Recommended Breaker Size
V, ph, Hz A
Refrigerant Type
Guaranteed Temperature Operation Range
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
Conditions
4Heating at 5°F (Indoor // Outdoor)
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
PVA-A24AA7
PUZ-HA24NHA1
24,000 10,00024,000
2,100 3.7 0.830 26,000 10,00028,000 1,980 17,500 26,000 26,000 -- 19.0 11.4 10.4 3.8 No
613744875
--
613744875
303438
303438
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 17.0 27
37-1/8 [943] 37-13/32 [950] 14-3/16 [360]
190 [86] 1940/1940
52 53 5/8 [15.88] 3/8 [9.52] 3/4 FPT [19.05] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-18.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PVA-A30AA7
PUZ-HA30NKA
30,000 14,80030,000
2,300 5.9 0.780 32,000 14,80034,000 2,460 21,000 32,000 32,000 -- 18.0 13.0 9.8 3.8 Yes
613744875
--
613744875
303438
303438
0.300.50.8 --
54-1/4 [1378] 21 [534]
21-5/8 [548] 141 [64] 24.0 40
52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360]
261 [118] 3880/3880
52 53 5/8 [15.88] 3/8 [9.52] 3/4 FPT [19.05] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-18.0 to 46.0] -13 to 75 [-25.0 to 24.0]
°F
80 DB, 67 WB // 95 DB, 75 WB
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
°F
70 DB, 60 WB // 5 DB, 4 WB
60-140V/200/250 Optional
Optional
Optional
Optional
PVA-A36AA7
PUZ-HA36NKA
33,000 15,50036,000
2,500 3.8 0.870 38,000 18,60040,000 2,850 24,600 38,000 38,000 -- 18.2 13.0 11.2 3.9 Yes
7889561125
--
7889561125
303438
303438
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 24.0 40
52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360]
261 [118] 3880/3880
52 53 5/8 [15.88] 3/8 [9.52] 3/4 FPT [19.05] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-18.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PVA-A42AA7
PUZ-HA42NKA1
42,000 17,00042,000
3,960 5.3 0.860 48,000 23,90054,000 3,850 38,500 48,000 48,000 -- 15.4 10.6 10.0 3.7 No
104012621485
--
104012621485
364044
364044
0.300.50.8 --
59-1/2 [1511] 25 [635]
21-5/8 [548] 172 [78] 36.0 44
52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360]
283 [128] 3319/3319
49 51 5/8 [15.88] 3/8 [9.52] 3/4 FPT [19.05] 245 [75] 100 [30] 208/230, 1, 60 40 R410A 0 to 115 [-18.0 to 46.0] -13 to 75 [-25.0 to 24.0]
96 P-Series
PEAD Model
Mid Static Horizontal-ducted Indoor Unit
Compact Indoor Units
The height is only 9-7/8" for all sizes of this model ranging from 12 to 42 KBTU/H. Its compact size allows for the unit installations in low ceilings with minimal clearance space.
External Static Pressure
External static pressure conversion can be set up to five settings. Capable of being set to a maximum of 0.60 In.W.G., units are applicable to a wide range of building types.
High Energy Efficiency
SEER
21.1
19.9
AA5 Series
(previous model)
AA7 Series
(current model)
19.6
19.1
19.1
16.0
16.1
15.5
15.0
13.8
Model
12
18
24
30
36
42
PEAD-AA7
0.14-0.20-0.28-0.40-0.60 In. W.G.
HSPF
10.8
AA5 Series
(previous model)
10.8
AA7 Series
(current model)
10.2
10.2 10.2
9.4
9.9 9.8
10.0 10.0
12
18
24
30
36
42
12
18
24
30
36
42
Built-in Drain Lift Mechanism
All sizes feature a built-in drain lift mechanism for the removal of condensate. A fail-safe mechanism recognizes a high liquid level in the condensate pan and turns off the indoor fan and the outdoor unit compressor to prevent overflow.
98 P-Series
PEAD Model
Model Selection
Indoor Unit
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
Outdoor Unit
Cooling Only PUY-A12/18NKA7
PUY-A24/30NHA7
PUY-A36/42NKA7
PEAD-A12/18/24/30/36/42AA7
Heat Pump
PUZ-A12/18NKA7
PUZ-A24/30NHA7
PUZ-A36/42NKA7
Remote Controller
Hyper-heating PUZ-HA24NHA1
PUZ-HA30/36NKA
PUZ-HA42NKA1
*optional AAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
P-Series 99
PEAD Model
Optional
Cooling Only
Wi-Fi Interface
Optional
Optional
Optional
Optional
60-140V/200/250 Optional
Optional
Optional
Optional
Indoor Unit
PEAD-A12AA7
PEAD-A18AA7
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Rated 1 Min-Max Rated 1 Pints/h
Rated Min-Max Rated Rated Max Max Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H
Dimensions
W
D
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM
PUY-A12NKA7(-BS)
12,000 5,00012,000
920 1.8 0.830 -- -- -- -- -- -- -- 21.1 13.0 -- -- Yes
353424494
PUY-A18NKA7(-BS)
18,000 8,00018,000
1,660 3.7 0.770 -- -- -- -- -- -- -- 19.9 10.8 -- -- No
424512600
PUY-A24NHA7(-BS)
24,000 10,00024,000
2,050 6.9 0.680 -- -- -- -- -- -- -- 19.6 11.7 -- -- No
512635741
PUY-A30NHA7(-BS)
30,000 9,00030,000
3,000 8.6 0.680 -- -- -- -- -- -- -- 19.1 10.0 -- -- No
618742883
PUY-A36NKA7(-BS)
36,000 16,00036,000
3,000 8.1 0.750 -- -- -- -- -- -- -- 19.1 12.0 -- -- No
84710241201
PUY-A42NKA7(-BS)
42,000 16,00042,000
3,920 9.0 0.760 -- -- -- -- -- -- -- 16.1 10.7 -- -- No
104212541483
CFM
318382445
382461540
461572667
556668795
7629221081
100212141443
CFM
353424494
424512600
512635741
618742883
84710241201
104212541483
dB(A)
283034
303337
303337
303439
333842
364044
dB(A)
283034
303337
303337
303439
333842
364044
In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
35-7/16 [900]
35-7/16 [900]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
55-1/8 [1400]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
58 [26]
62 [28]
69 [31]
69 [31]
86 [39]
91 [41]
11.0
11.0
19.0
19.0
25.0
25.0
28
28
26
26
31
31
24-13/16 [630]
24-13/16 [630]
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
31-13/16 (+7/16) [809 31-13/16 (+7/16) [809
(+62)]
(+62)]
11-3/16 [300]
11-3/16 [300]
37-13/32 [950]
13 (+1-3/16) [330 (+30)]
37-13/32 [950]
13 (+1-3/16) [330 (+30)]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
92 [41]
99 [44]
151 [68]
151 [68]
211 [96]
211 [96]
1590/--
1590/--
1940/--
1940/--
3880/--
3880/--
44
44
47
47
52
52
--
--
--
--
--
--
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
165 [50]
165 [50]
225 [68]
225 [68]
225 [68]
225 [68]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
-40 to 115 [-40.0 to 46.0]
--
--
--
--
--
--
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
100 P-Series
PEAD Model
Optional
Optional
Optional
Optional
Optional
Optional
Wi-Fi Interface
Optional
Heat Pump
Optional
Optional
Indoor Unit
PEAD-A12AA7
PEAD-A18AA7
PEAD-A24AA7
PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H
Dimensions
W
D
Weight Air Flow Rate (Cooling/Heating) Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM
PUZ-A12NKA7(-BS)
12,000 5,00012,000
920 1.8 0.830 14,000 5,80018,000 1,030 8,700 10,500 10,000 -- 21.1 13.0 10.2 3.98 Yes
353424494
PUZ-A18NKA7(-BS)
18,000 8,00018,000
1,660 3.7 0.770 19,000 7,90022,000 1,400 11,000 13,500 11,400 -- 19.9 10.8 10.2 3.97 No
424512600
PUZ-A24NHA7(-BS)
24,000 10,00024,000
2,050 6.9 0.680 26,000 9,00028,000 1,750 14,800 17,200 14,300 -- 19.6 11.7 10.8 4.35 No
512635741
PUZ-A30NHA7(-BS)
30,000 9,00030,000
3,000 8.6 0.680 32,000 8,80034,000 2,490 18,500 21,200 17,700 -- 19.1 10.0 10.8 3.76 No
618742883
PUZ-A36NKA7(-BS)
36,000 16,00036,000
3,000 8.1 0.750 38,000 18,20040,000 2,410 20,800 24,200 19,800 -- 19.1 12.0 9.9 4.62 No
84710241201
PUZ-A42NKA7(-BS)
42,000 16,00042,000
3,920 9.0 0.760 45,000 18,10048,000 3,290 30,600 33,700 29,400 -- 16.1 10.7 10.0 4.0 No
104212541483
CFM
318382445
382461540
461572667
556668795
7629221081
100212141443
CFM
353424494
424512600
512635741
618742883
84710241201
104212541483
dB(A)
283034
303337
303337
303439
333842
364044
dB(A)
283034
303337
303337
303439
333842
364044
In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6 0.140.20.280.40.6
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
27-9/16 [700]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
9-7/8 [250]
35-7/16 [900]
35-7/16 [900]
43-5/16 [1100]
43-5/16 [1100]
55-1/8 [1400]
55-1/8 [1400]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
28-7/8 [732]
58 [26]
62 [28]
69 [31]
69 [31]
86 [39]
91 [41]
11.0
11.0
19.0
19.0
25.0
25.0
28
28
26
26
31
31
24-13/16 [630]
24-13/16 [630]
37-1/8 [943]
37-1/8 [943]
52-11/16 [1338]
52-11/16 [1338]
31-13/16 (+7/16) [809 31-13/16 (+7/16) [809
(+62)]
(+62)]
11-3/16 [300]
11-3/16 [300]
37-13/32 [950]
13 (+1-3/16) [330 (+30)]
37-13/32 [950]
13 (+1-3/16) [330 (+30)]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
41-5/16 [1050]
13 (+1-3/16) [330 (+30)]
93 [42]
100 [45]
153 [69]
153 [69]
214 [97]
214 [97]
1590/1590
1590/1590
1940/1940
1940/1940
3880/3880
3880/3880
44
44
47
47
52
52
46
46
48
48
53
53
1/2 [12.7]
1/2 [12.7]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
5/8 [15.88]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
3/8 [9.52]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
1-1/4 [32]
100 [30]
100 [30]
165 [50]
165 [50]
165 [50]
165 [50]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
100 [30]
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
208/230, 1, 60
15
15
25
25
30
30
R410A
R410A
R410A
R410A
R410A
R410A
0 to 115 [-18.0 to 46.0]
12 to 70 [-11.0 to 21.0]
0 to 115 [-18.0 to 46.0]
12 to 70 [-11.0 to 21.0]
0 to 115 [-18.0 to 46.0]
-4 to 70 [-20.0 to 21.0]
0 to 115 [-18.0 to 46.0]
-4 to 70 [-20.0 to 21.0]
0 to 115 [-18.0 to 46.0]
-4 to 70 [-20.0 to 21.0]
0 to 115 [-18.0 to 46.0]
-4 to 70 [-20.0 to 21.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
Conditions
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
P-Series 101
PEAD Model
Optional
Hyper-heating
Wi-Fi Interface
Optional
Indoor Unit Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
Conditions
4Heating at 5°F (Indoor // Outdoor)
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
Optional
Optional
Optional
PEAD-A24AA7
PUZ-HA24NHA1
24,000 10,00024,000
2,080 6.9 0.680 25,000 10,00028,000 1,920 18,000 25,000 25,000 -- 16.6 11.5 10.4 3.8 No
512635741
461572667
512635741
303337
303337
0.140.20.280.40.6 27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732] 69 [31] 17.0 27 37-1/8 [943] 37-13/32 [950] 14-3/16 [360] 190 [86] 1940/1940 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PEAD-A30AA7
PUZ-HA30NKA
30,000 14,60030,000
2,350 6.5 0.760 32,000 14,80034,000 2,740 21,000 32,000 32,000 -- 18.1 12.7 9.6 3.4 Yes
618742883
556668795
618742883
303439
303439
0.140.20.280.40.6 27-9/16 [700] 9-7/8 [250] 43-5/16 [1100] 28-7/8 [732] 69 [31] 24.0 40 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
°F
80 DB, 67 WB // 95 DB, 75 WB
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
°F
70 DB, 60 WB // 5 DB, 4 WB
60-140V/200/250 Optional
Optional
Optional
Optional
PEAD-A36AA7
PUZ-HA36NKA
36,000 15,60036,000
2,850 5.2 0.840 38,000 17,40040,000 2,940 25,400 38,000 38,000 -- 17.1 12.6 10.4 3.8 Yes
84710241201
7629221081
84710241201
333842
333842
0.140.20.280.40.6 27-9/16 [700] 9-7/8 [250] 55-1/8 [1400] 28-7/8 [732] 86 [39] 26.0 42 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PEAD-A42AA7
PUZ-HA42NKA1
42,000 17,10042,000
3,900 4.1 0.890 48,000 21,20054,000 3,990 39,000 48,000 48,000 -- 15.0 10.7 9.8 3.5 No
104212541483
100212141443
104212541483
364044
364044
0.140.20.280.40.6 27-9/16 [700] 9-7/8 [250] 55-1/8 [1400] 28-7/8 [732] 91 [41] 36.0 44 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 283 [128] 3319/3319 49 51 5/8 [15.88] 3/8 [9.52] 1-1/4 [32] 245 [75] 100 [30] 208/230, 1, 60 40 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
102 P-Series
PCA Model
Ceiling-suspended Indoor Unit
High Energy Efficiency
SEER
21.2
16.8
KA6 Series
(previous model)
19.6
19.1
14.5
14.4
KA7 Series
(current model)
17.6 15.8
HSPF
10.9 10.8
KA6 Series
(previous model)
KA7 Series
(current model)
10.0 9.2
10.2 10.2
10.2 10.2
24
30
36
42
24
30
36
42
Optional Drain Pump Available for All Models
The pumping height of the optional drain pump is 23-5/8", expanding flexibility in choosing the indoor unit location.
Drain pump installation possible
Drainage outlet can be 23-5/8" above ceiling surface
Ceiling surface
Equipped with Automatic Air-speed Adjustment Strong
The Automatic Air-speed Adjustment setting changes the speed to match the
room environment conditions. The airflow is set to high at the start of the
Start of the heating/cooling operation
heating or cooling operation, quickly conditioning the space. When the room
temperature reaches the setpoint, the airflow decreases automatically for Strong
stable, comfortable heating and cooling operation.
Gentle
After setpoint is reached
Gentle
Start of the heating/cooling operation
After setpoint is reached
Equipped with High/Low-Ceiling Modes
High- and Low-ceiling Operation modes match the airflow volume to the room height. This option adjusts the airflow volume and ensures even temperature distribution throughout the room.
Capacity (KBTU/H)
24
30
36
High ceiling (ft)
11.5
11.5
13.8
Standard ceiling (ft)
8.9
8.9
9.8
Low ceiling (ft)
8.2
8.2
8.5
42
13.8
9.8
8.5
104 P-Series
PCA Model
Model Selection
Indoor Unit
Cooling Only
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
Outdoor Unit
PUY-A24/30NHA7
PUY-A36/42NKA7
PCA-A24/30/36/42KA7
Heat Pump
PUZ-A24/30NHA7
PUZ-A36/42NKA7
Remote Controller
Hyper-heating PUZ-HA24NHA1
PUZ-HA30/36NKA
PUZ-HA42NKA1
*optional AAR-40MAAU
*optional PAC-YT53CRAU-J
*optional
*optional PAR-CT01MAU-SB
P-Series 105
PCA Model
Optional
Cooling Only
Wi-Fi Interface
Optional
Optional
Optional
Optional
Indoor Unit
PCA-A24KA7
PCA-A30KA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated Min-Max Rated Rated Max Max Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
PUY-A24NHA7(-BS)
24,000 10,00024,000
1,960 5.8 0.730 -- -- -- -- -- -- -- 21.2 12.2 -- -- No
530565600670
495530565635
530565600670
33353740
33353740
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 225 [68] 100 [30] 208/230, 1, 60 25 R410A -40 to 115 [-40.0 to 46.0] --
PUY-A30NHA7(-BS)
30,000 9,00030,000
3,190 8.3 0.690 -- -- -- -- -- -- -- 19.6 9.4 -- -- No
565600635705
530565600670
565600635705
35373941
35373941
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 151 [68] 1940/-- 47 -- 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 225 [68] 100 [30] 208/230, 1, 60 25 R410A -40 to 115 [-40.0 to 46.0] --
Notes: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring. 6Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
60-140V/200/250 Optional
Optional
Optional
Optional
PCA-A36KA7
PUY-A36NKA7(-BS)
36,000 16,00036,000
3,270 8.7 0.730 -- -- -- -- -- -- -- 19.1 11.0 -- -- No
775850920990
705775850920
775850920990
37394143
37394143
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 79 [36] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 -- 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 225 [68] 100 [30] 208/230, 1, 60 30 R410A -40 to 115 [-40.0 to 46.0] --
PCA-A42KA7
PUY-A42NKA7(-BS)
42,000 16,00042,000
4,110 11.7 0.690 -- -- -- -- -- -- -- 17.6 10.2 -- -- No
8108859551025
740810885955
8108859551025
39414345
39414345
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 86 [39] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 211 [96] 3880/-- 52 -- 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 225 [68] 100 [30] 208/230, 1, 60 30 R410A -40 to 115 [-40.0 to 46.0] --
106 P-Series
PCA Model
Optional
Optional
Heat Pump
Optional
Optional
Indoor Unit
PCA-A24KA7
PCA-A30KA7
Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
PUZ-A24NHA7(-BS)
24,000 10,00024,000
1,960 5.8 0.730 26,000 8,80028,000 1,800 15,400 17,900 14,900 -- 21.2 12.2 10.8 4.23 No
530565600670
495530565635
530565600670
33353740
33353740
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
PUZ-A30NHA7(-BS)
30,000 9,00030,000
3,190 8.3 0.690 32,000 8,60034,000 2,520 18,800 21,600 18,000 -- 19.6 9.4 10.0 3.72 No
565600635705
530565600670
565600635705
35373941
35373941
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 19.0 26 37-1/8 [943] 37-13/32 [950] 13 (+1-3/16) [330 (+30)] 153 [69] 1940/1940 47 48 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
°F
80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) 3Heating at 17°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
Conditions
4Heating at 5°F (Indoor // Outdoor)
°F
70 DB, 60 WB // 5 DB, 4 WB
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
· External Outer Panel: Phosphate coating + Acrylic-Enamel coating
· Fan Motor Support: Epoxy resin coating (at edge face)
· Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
· "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
Optional
Optional
Optional
Optional
Wi-Fi Interface
Optional
PCA-A36KA7
PUZ-A36NKA7(-BS)
36,000 16,00036,000
3,270 8.7 0.730 38,000 17,90040,000 2,410 21,000 24,400 20,000 -- 19.1 11.0 10.2 4.62 No
775850920990
705775850920
775850920990
37394143
37394143
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 79 [36] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 214 [97] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 165 [50] 100 [30] 208/230, 1, 60 30 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
PCA-A42KA7
PUZ-A42NKA7(-BS)
42,000 16,00042,000
4,110 11.7 0.690 45,000 18,10048,000 3,480 31,800 35,000 30,500 -- 17.6 10.2 10.2 3.78 No
8108859551025
740810885955
8108859551025
39414345
39414345
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 86 [39] 25.0 31 52-11/16 [1338] 41-5/16 [1050] 13 (+1-3/16) [330 (+30)] 214 [97] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 165 [50] 100 [30] 208/230, 1, 60 30 R410A 0 to 115 [-18.0 to 46.0] -4 to 70 [-20.0 to 21.0]
P-Series 107
PCA Model
Optional
Hyper-heating
Wi-Fi Interface
Optional
Indoor Unit Outdoor Unit Cooling
Heating
Efficiency
Indoor Unit
Outdoor Unit
Piping Electrical Refrigerant Type Guaranteed Temperature Operation Range
Capacity Capacity Range Power Input Moisture Removal Sensible Heat Factor Capacity at 47ºF Capacity Range Power Input at 47ºF
Capacity at 17ºF
Capacity at 5ºF Capacity at -5ºF SEER EER HSPF COP ENERGY STAR® Certified Air Flow Rate - Cooling (Quiet-Lo-Med-Hi-SHi) Air Flow Rate - Cooling (Quiet-LoMed-Hi-SHi) Air Flow Rate - Heating (Quiet-LoMed-Hi-SHi) Sound Pressure Level (Quiet-Lo-Med-Hi-SHi) Sound Pressure Level (Quiet-LoMed-Hi-SHi) External Static Pressure Condensate Lift Mechanism
Dimensions
Weight MCA MOCP
Dimensions
Weight Air Flow Rate (Cooling/Heating)
Sound Pressure Level
Diameter
Max. Length Max. Height Outdoor-Indoor5 Recommended Breaker Size
Rated 1 Min-Max Rated 1 Pints/h
Rated 2 Min-Max Rated 2 Rated 3 Max Max 4 Max
Dry
Wet
Dry
Cooling
Heating
Max Distance H W D lbs [kg] A A H W D lbs [kg] CFM Cooling Heating Gas (O.D.) Liquid (O.D) Indoor Drain ft [m] ft [m] V, ph, Hz A
BTU/H BTU/H W
BTU/H BTU/H W BTU/H BTU/H BTU/H BTU/H
CFM CFM CFM dB(A) dB(A) In. W.G. In. [mm] In. [mm] In. [mm] In. [mm]
In. [mm] In. [mm] In. [mm]
dB(A) dB(A) In. [mm] In. [mm] In. [mm]
Cooling6 Heating
ºF DB [ºC DB] ºF DB [ºC DB]
Notes:
AHRI Rated Conditions
1Cooling (Indoor // Outdoor)
(Rated data is determined
2Heating at 47°F (Indoor // Outdoor)
at a fixed compressor speed)
3Heating at 17°F (Indoor // Outdoor)
Conditions
4Heating at 5°F (Indoor // Outdoor)
5Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0° F - 115° F.
Optional
Optional
Optional
PCA-A24KA7
PUZ-HA24NHA1
23,000 10,00024,000
1,840 5.6 0.730 26,000 10,00028,000 2,050 17,700 26,000 26,000 -- 18.5 12.5 10.3 3.71 Yes
530565600670
495530565635
530565600670
33353740
33353740
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 17.0 27 37-1/8 [943] 37-13/32 [950] 14-3/16 [360] 190 [86] 1940/1940 52 53 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 165 [50] 100 [30] 208/230, 1, 60 25 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PCA-A30KA7
PUZ-HA30NKA
30,000 14,30030,000
2,380 8.3 0.690 32,000 14,40035,000 2,930 22,200 32,000 32,000 -- 17.9 12.6 9.4 3.2 Yes
565600635705
530565600670
565600635705
35373941
35373941
-- -- 9-1/16 [230] 50-3/8 [1280] 26-3/4 [680] 71 [32] 24.0 40 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
°F
80 DB, 67 WB // 95 DB, 75 WB
°F
70 DB, 60 WB // 47 DB, 43 WB
°F
70 DB, 60 WB // 17 DB, 15 WB
°F
70 DB, 60 WB // 5 DB, 4 WB
60-140V/200/250 Optional
Optional
Optional
Optional
PCA-A36KA7
PUZ-HA36NKA
34,000 14,90034,000
2,700 7.9 0.740 38,000 17,40040,000 3,360 25,400 38,000 38,000 -- 18.0 12.5 10.3 3.31 Yes
775850920990
705775850920
775850920990
37394143
37394143
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 79 [36] 26.0 42 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 261 [118] 3880/3880 52 53 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 245 [75] 100 [30] 208/230, 1, 60 35 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
PCA-A42KA7
PUZ-HA42NKA1
42,000 16,60042,000
4,050 10.6 0.720 48,000 24,00054,000 4,760 38,500 48,000 48,000 -- 15.5 10.3 10.0 2.95 No
8108859551025
740810885955
8108859551025
39414345
39414345
-- -- 9-1/16 [230] 63 [1600] 26-3/4 [680] 86 [39] 36.0 44 52-11/16 [1338] 41-5/16 [1050] 14-3/16 [360] 283 [128] 3319/3319 49 51 5/8 [15.88] 3/8 [9.52] 1-1/32 [26] 245 [75] 100 [30] 208/230, 1, 60 40 R410A 0 to 115 [-10.0 to 46.0] -13 to 75 [-25.0 to 24.0]
108 P-Series
Multi-Zone Models
Nv-Series multi-zone outdoor units operate 2 to 8 indoor units on the same system.
Multi-zone Nv-Model Lineup
Choose from six types of indoor units and thirteen outdoor units that can run up to eight indoor units each.
Step 1: Select Your Indoor Unit to be Installed in Each Room
Choose from Wall-mounted, Floor-mounted, Multi-position Air Handler, Ceiling Cassette, Ceiling-suspended or Horizontal-ducted Indoor Units..
Wall-mounted Floor-mounted
Multi-position Air Handler
Ceiling Cassette
Ceiling-suspended Horizontal-ducted
CKS WPH
MSZ-EF FKS
WST
AMT
PLA
DKS
PCA
UKS PEAD
Step 2: Select Your Outdoor Unit
Select the best outdoor unit based on the number of indoor units and overall system capacity required.
2-port
Up to 2 indoor units
3-port
Up to 3 indoor units
4-port
Up to 4 indoor units
5-port
Up to 5 indoor units
8-port
Up to 8 indoor units
NAXMMX20A122AA NAXMMX24A132AA NAXMMX36A142AA NAXMMX30A132AA
Hyper-heating Models
NAXMMX42A152AA NAXMMX48A182BA
NAXMMX60A182BA
Branch Box needed*
2-port
Up to 2 indoor units
3-port
Up to 3 indoor units
4-port
Up to 4 indoor units
5-port
Up to 5 indoor units
8-port
Up to 8 indoor units
NAXMPH20A122AA NAXMPH24A132AA NAXMPH36A142BA NAXMPH42A152BA NAXMPH48A182BA
NAXMPH30A132AA
Branch Box needed*
Branch Box needed*
Branch Box needed*
Step 3: Check System Compatibility
Possible combinations depends on the outdoor unit chosen. Please check the following points.
Check Indoor Units Refer to the Indoor Unit Compatibility Table to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Check Branch Box Refer to the Indoor Unit Compatibility Table for units that require a Branch Box.
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
Multi-Zone Nv-Models 111
MX Models
Mulit-zone Heat Pump Outdoor Unit
2-port
NAXMMX20A122AA
3-port and 4-port
NAXMMX24A132AA NAXMMX30A132AA NAXMMX36A142AA
Example System
Smaller MX 2, 3, 4 and 5 ports ((eexxaammplpeloef oNfANXMTXMMX4M2AX14522AA15**2*sy*stseymst)em)
MSZ-EF
WST
WPH
5-port
NAXMMX42A152AA
8-port
NAXMMX48A182BA NAXMMX60A182BA
8 Port Branch Box required
WPH WST UKS
NTXMMX48A182** NNATXXMMMMX4X8A6108A2B1A82**
NAXMMX60A182BA
TAC-MKA52BC
TAC-MKA32BC
MSZ-EF FKS
FKS
CKS
NTXNMAXMMXM4X422AA11552A2A**
MSDD-50AR-E or
MSDD-50BR-E
CKS
TPEAD
NTNXAMXMMMXX6600AA11882B*A*
AMT
Refer to the multi-zone compatibility table on page 9.
Handle Up to 8 Rooms with a Single Outdoor Unit
The MX Model offers a seven-system line-up to choose from, ranging between 20,000 and 60,000 BTU/H. All of them are compatible with specific Nv- and P-Series indoor units. A single outdoor unit can handle a wide range of building layouts.
Optional Drain for All Models
With MX Model one outdoor unit can cool and heat up to eight rooms. They can be installed neatly in sites with limited space such as condominium balconies.
Single air conditioner
Clean/neat installation
Multi air conditioner system
112 Multi-Zone Nv-Models
MX Model
35-71
100-250
35-140
JointL ap
Vector Sine Wave
DC Scroll
DC FanM otor
Vector-Wave
Grooved Piping
35-71
Heat Caulking Fixing Method
INVERTER-driven Multi-zone Heat Pump
Type
Up to 2 indoor units
Up to 3 indoor units
Up to 4
Up to 5
indoor units indoor units
Up to 8 indoor units
Outdoor Unit
NAXMMX20A122AA NAXMMX24A122AA NAXMMX30A122AA NAXMMX36A122AA NAXMMX42A122AA NAXMMX48A122AA NAXMMX60A122AA
Branch Box Required
No
No
Power Supply
Source Outdoor (Phase, Hz, V)
R410A 1-phase, 60Hz,
208/230V
R410A 1-phase, 60Hz,
208/230V
Capacity
Rated *1 BTU/H
18,000
22,000
Cooling
SEER
EER
Heating
Capacity
Rated *1 Max at 17F
*2 Max at 5F *3
BTU/H BTU/H BTU/H
22,000 12,500 11,100
25,000 19,600 18,200
HSPF
MCA
A
17.2
22.1
Recommended Fuse/Breaker Size
A
20
25
W
In. [mm] 33-1/16 [840] 37-13/32 [950]
Outdoor Unit
Dimensions
D
H
Weight
In. [mm] In. [mm] lbs [kg]
13 [330] 27-15/16 [710]
126 [57]
13 [330] 31-11/32 [796]
137 [62]
Air volume (Cooling/Heating)
CFM
1,342/1,458
2,287/2,382
Sound Level
Cooling Heating
dB [A] dB [A]
50 54
51 55
Diameter
Gas
In. [mm] 3/8 [9.52]
A: 1/2 [12.7] B,C: 3/8 [9.52]
Piping
Liquid In. [mm] 1/4 [6.35]
1/4 [6.35]
Max. Length
ft [m]
164 [50]
230 [70]
Height
ft [m]
49 [15]
49 [15]
Guaranteed Operation Range
Cooling Heating
F [C]
14 ~ 115°FDB 14 ~ 115°FDB [-10 ~ 46°CDB] [-10 ~ 46°CDB]
F [C]
5 ~ 75°FDB
5 ~ 75°FDB
[-15 ~ 24°CDB] [-15 ~ 24°CDB]
NOTE:
Test conditions are based on AHRI 210/240.
*1 Rating Conditions (Cooling) - Indoor: 80° FDB, 67° FWB, Outdoor: 95° FDB, (75° FWB)
(Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 47° FDB, 43° FWB
*2 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 17° FDB, 15° FWB
*3 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 5° FDB, 5° FWB
*5 °F DB - 115°F DB when optional wind baffles are installed
No R410A 1-phase, 60Hz, 208/230V 28,400
No R410A 1-phase, 60Hz, 208/230V 35,400
No R410A 1-phase, 60Hz, 208/230V 40,500
Yes R410A 1-phase, 60Hz, 208/230V 48,000
Yes R410A 1-phase, 60Hz, 208/230V 60,000
Refer to page 154
28,600
21,000
18,200
22.1 25 37-13/32 [950] 13 [330] 31-11/32 [796] 137 [62] 2,287/2,382 52 56 A: 1/2 [12.7] B,C: 3/8 [9.52] 1/4 [6.35] 230 [70] 49 [15] 14 ~ 115°FDB [-10 ~ 46°CDB] 5 ~ 75°FDB [-15 ~ 24°CDB]
36,000
45,000
54,000
66,000
26,600
30,500
36,600
65,000
24,000
26,000
32,400
57,000
Refer to page 154
22.1
32.5
35.0
46.0
25
40
40
50
37-13/32 [950] 37-13/32 [950] 41-11/32 [1,050] 41-11/32 [1,050]
13 [330]
13 [330]
13+1 [330+25] 13+1 [330+25]
31-11/32 [796] 41-17/64 [1,048] 52-11/16 [1,338] 52-11/16 [1,338]
139 [63]
189 [86]
271 [123]
302 [137]
2,287/2,382
2,118/2,542
3,885
4,879
54
56
51
58
56
58
54
59
A: 1/2 [12.7]
A: 1/2 [12.7]
B,C,D: 3/8 [9.52] B,C,D,E: 3/8 [9.52]
5/8 [15.88]
3/4 [19.05]
1/4 [6.35]
1/4 [6.35]
3/8 [9.52]
3/8 [9.52]
230 [70]
262 [80]
492 [150]
492 [150]
49 [15]
49 [15]
164 [50]
164 [50]
14 ~ 115°FDB 14 ~ 115°FDB 23 ~ 115°FDB 23 ~ 115°FDB
[-10 ~ 46°CDB] [-10 ~ 46°CDB] [-5 ~ 46°CDB] *5 [-5 ~ 46°CDB] *5
5 ~ 75°FDB
5 ~ 75°FDB
-4 ~ 70°FDB
-4 ~ 70°FDB
[-15 ~ 24°CDB] [-15 ~ 24°CDB] [-20 ~ 21°CDB] [-20 ~ 21°CDB]
Branch Box
Type
Branch Box
Model Name Connectible Number of Indoor Units
Power Supply
Input Running Current
Dimensions
Weight
kW A W In. [mm] D In. [mm] H In. [mm] lbs [kg]
Piping Connection (Flare)
Branch Gas In. [mm]
(indoor side)* Liquid In. [mm]
Main
Gas In. [mm]
(outdoor side)* Liquid In. [mm]
PAC-MKA32BC Maximum 3
1-phase, 60Hz, 208/230V 0.003 0.05
17-23/32 [450] 11-1/32 [280] 6-11/16 [170]
15 [6.7]
3/8 [9.52] × 3
1/4 [6.35] × 3 5/8 [15.88] 3/8 [9.52]
PAC-MKA52BC Maximum 5
1-phase, 60Hz, 208/230V 0.003 0.05
17-23/32 [450] 11-1/32 [280] 6-11/16 [170]
16 [7.4]
3/8 [9.52] × 4 1/2 [12.7] × 1
1/4 [6.35] × 5 5/8 [15.88] 3/8 [9.52]
*The piping connection size differs according to the type and capacity of indoor units. Match the piping connection size for indoor and branch box. If the piping connection size of branch box does not match the piping connection size of indoor units, use optional different-diameter (deformed) joints to the branch box side. (Connect deformed joint directly to the branch box side.)
Multi-Zone Nv-Models 113
MPH Model
Hyper-Heating INVERTER® Performance
Standard rated heating capacity is maintained even when the outside-air temperature drops to 5° F. Maintains high capacity output even when outside-air temperature is low.
N A X M M X 20A122 A A
Hyper Heating
N A X M PH20A122 A A
Our conventional 22,000 BTUH
model was not able
to maintain standard rated
Falls 12,500 BTUH
heating capacity,
making it hard to provide warming in case of low
Capacity decreased due to low outdoor-air temperature
outside-air
With outside
With outside
temperature of 47° F
temperature of 5° F
(standard rated heating capacity)
22,000 BTUH
Maintained
Provides standard rating (47° F) level heating capacity even with outside-air temperature of 5° F
With outside
With outside
temperature of 47° F temperature of 5° F
(standard rated heating capacity)
Can Operate At Outside-Air Temperature Of 13° F
Incorporated key parts resistant to cold of up to 13° F after rigorous selection. Printed circuit board is coated on both sides to protect it in harsh environments.
Base Pan Heater Built-In
Drain water freezes after operation in extreme low temperatures
Hyper heating with base heater installed as standard prevents ice build up
Without base heater
114 Multi-Zone Nv-Models
With base heater
Hyper-heating Multi-zone Outdoor Units
Type
Up to 2 indoor units
Up to 3 indoor units
Up to 4 indoor units
Up to 5 indoor units
Up to 8 indoor units
Outdoor Unit
NAXMPH20A122AA NAXMPH24A122AA NAXMPH30A122AA NAXMPH36A122AA NAXMPH42A122AA NAXMPH48A122AA
Branch Box Required
Source
Power Supply
Outdoor (Phase, Hz, V)
Recommended Breaker Size
Capacity
Rated *1
BTU/H
Cooling
SEER
EER
Rated *1
BTU/H
Heating Capacity Max at 17F *2 BTU/H Max at 5F *3 BTU/H
HSPF
MCA
A
Recommended breaker/fuse size
A
W
In. [mm]
Out- Dimensions
D
In. [mm]
door
H
In. [mm]
Unit
Weight
lbs [kg]
Air volume (Cooling/Heating) CFM
Sound Level
Cooling Heating
dB [A] dB [A]
Piping
Diameter
Gas
Liquid
Max. Length
Height
In. [mm]
In. [mm] ft [m] ft [m]
Guaranteed
Cooling
F [C]
Operation Range
Heating
F [C]
No R410A 1-phase, 60Hz, 208/230V
40 18,000
22,000 22,000 22,000
29.5 40 37-13/32 [950] 13 [330] 41-17/64 [1,048] 187 [85] 2,118/2,542 54 58
3/8 [9.52]
1/4 (6.35) 164 [50] 49 [15] 14 ~ 115°FDB [-10 ~ 46°CDB] -13 ~ 75°FDB [-25 ~ 24°CDB]
No R410A 1-phase, 60Hz, 208/230V
40 22,000
25,000 25,000 25,000
30.5
40
37-13/32 [950] 13 [330]
41-17/64 [1,048] 189 [86]
2,188/2,542 54 58
A: 1/2 [12.7] B,C: 3/8 [9.52]
1/4 (6.35) 230 [70] 49 [15] 14 ~ 115°FDB [-10 ~ 46°CDB] -13 ~ 75°FDB [-25 ~ 24°CDB]
No R410A 1-phase, 60Hz, 208/230V
40 28,400
Yes R410A 1-phase, 60Hz, 208/230V
50 36,000
Refer to page 154
28,600
45,000
28,600
45,000
28,600
45,000
Refer to page 154
30.5
42
50
45
41-11/32 [1,050] 13 [330]
41-17/64 [1,048] 189 [86]
2,224/2,542 54 58
A: 1/2 [12.7] B,C: 3/8 [9.52]
1/4 (6.35) 230 [70] 49 [15] 14 ~ 115°FDB [-10 ~ 46°CDB]
-13 ~ 75°FDB [-25 ~ 24°CDB]
41-11/32 [1,050] 13+1 [330+25] 52-11/16 [1,338]
278 [126] 3,885 49 53
5/8 [15.88]
3/8 [9.52] 492 [150] 164 [50] 23 ~ 115°FDB [-5 ~ 46°CDB] *5 -13 ~ 70°FDB [-25 ~ 21°CDB]
Yes R410A 1-phase, 60Hz, 208/230V
42,000
48,000 48,000 48,000
42 45 41-11/32 [1,050] 13+1 [330+25] 52-11/16 [1,338] 278 [126] 3,885 50 54
5/8 [15.88]
3/8 [9.52] 492 [150] 164 [50] 23 ~ 115°FDB [-5 ~ 46°CDB] *5 -13 ~ 70°FDB [-25 ~ 21°CDB]
Yes R410A 1-phase, 60Hz, 208/230V
48,000
54,000 54,000 54,000
42 45 41-11/32 [1,050] 13+1 [330+25] 52-11/16 [1,338] 278 [126] 3,885 51 54
5/8 [15.88]
3/8 [9.52] 492 [150] 164 [50] 23 ~ 115°FDB [-5 ~ 46°CDB] *5 -13 ~ 70°FDB [-25 ~ 21°CDB]
NOTE: Test conditions are based on AHRI 210/240. *1 Rating Conditions (Cooling) - Indoor: 80° FDB, 67° FWB, Outdoor: 95° FDB, (75° FWB)
(Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 47° FDB, 43° FWB *2 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 17° FDB, 15° FWB *3 Rating Conditions (Heating) - Indoor: 70° FDB, 60° FWB, Outdoor: 5° FDB, 5° FWB *5 °F DB - 115°F DB when optional wind baffles are installed
Multi-Zone Nv-Models 115
Indoor Unit Compatibility Table
MMX Model *1
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit NAXMMX20A122AA NAXMMX24A122AA NAXMMX30A122AA NAXMMX36A122AA NAXMMX42A122AA NAXMMX48A122AA NAXMMX60A122AA
116
Indoor Unit
NAXWPH06A112A*
·
·
NAXWPH09A112A*
·
·
NAXWPH12A112A*
·
·
NAXWPH15A112A*
·
·
NAXWPH18A112A*
·
NAXWST06A112A*
·
·
Wall
NAXWST09A112A*
·
·
Mounted
NAXWST12A112A*
·
·
NAXWST15A112A*
·
·
NAXWST18A112A*
·
NAXWST24A112A*
MSZ-EF09NAW(S)(B)
·
·
MSZ-EF12NAW(S)(B)
·
·
MSZ-EF15NAW(S)(B)
·
·
MSZ-EF18NAW(S)(B)
·
NAXFKS09A112A*
·
·
Nv-Series
Floor
NAXFKS12A112A*
·
·
Standing
NAXFKS15A112A*
·
·
NAXFKS18A112A*
·
EZ FIT®
NAXUKS09A112A*
·
·
Recessed Ceiling
NAXUKS12A112A*
·
·
Cassette
NAXUKS18A112A*
·
·
NAXAMT12A112A*
·*2
·*2
NAXAMT18A112A*
·*2
Multi-position Air Handler
NAXAMT24A112A*
NAXAMT30A112A*
NAXAMT36A112A*
NAXCKS09A112A*
·
·
Four-way Cassette
NAXCKS12A112A*
·
·
NAXCKS15A112A*
·
NAXDKS09A112A*
·
·
Horizontal-
NAXDKS12A112A*
·
·
ducted
NAXDKS15A112A*
·
·
NAXDKS18A112A*
·
PLA-A12EA7
PLA-A18EA7
·
Four-way Cassette
PLA-A24EA7 PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
PCA-A24KA7
P-Series
Ceiling Suspended
PCA-A30KA7 PCA-A36KA7
PCA-A42KA7
PEAD-A12AA7
·*3
·*3
PEAD-A18AA7
·
Horizontalducted
PEAD-A24AA7 PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
Branch Box
3 port 5 port
PAC-MKA32BC PAC-MKA52BC
Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. A minimum of two indoor units must be connected to all MX outdoor units. *2 Only one AMT Model can be connected. *3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. *4 Single unit can be connected.
Multi-Zone Nv-Models
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·*2
·*2
·*2
·*3, 4
·*3, 4
·*2
·*2
·*2
·*3, 4
·*3, 4
·*2
·*2
·*2
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·*6
·*7
·
·
·
·*6
·*7
·
·
·
·*6
·*7
·
·
·
·*6
·*7
·*5
·*5
·
·
·
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·
·
·
·*3
·*3
·*3
·*6
·*7
·*3
·*3
·*3
·*6
·*7
·
·
·*3
·*6
·*7
·*6
·*7
·*6
·*7
·
·
·
·
*5 When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectable indoor units is decreased as follows: 3 for NAXMPH36A142BA, 4 for NAXMPH42A152BA, and 6 NAXMMX48A182BA, NAXMPH48A182BA, and NAXMMX60A182BA. *6 Maximum of 3 Horizontal-ducted indoor units (PEAD or DKS) can be connected. *7 Maximum of 2 Horizontal-ducted indoor units (PEAD or DKS) can be connected. For more information, please refer to the Service Manual, Application Note 1039 and the full compatibility chart on AmericanStandard.MyLinkDrive.com.
MPH Model *1
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit NAXMPH20A122AA NAXMPH24A122AA NAXMPH30A122AA NAXMPH36A122AA NAXMPH42A122AA NAXMPH48A122AA
Indoor Unit
NAXWPH06A112A*
·
·
NAXWPH09A112A*
·
·
NAXWPH12A112A*
·
·
NAXWPH15A112A*
·
·
NAXWPH18A112A*
·
NAXWST06A112A*
·
·
Wall
NAXWST09A112A*
·
·
Mounted
NAXWST12A112A*
·
·
NAXWST15A112A*
·
·
NAXWST18A112A*
·
NAXWST24A112A*
MSZ-EF09NAW(S)(B)
·
·
MSZ-EF12NAW(S)(B)
·
·
MSZ-EF15NAW(S)(B)
·
·
MSZ-EF18NAW(S)(B)
·
NAXFKS09A112A*
·
·
Nv-Series
Floor
NAXFKS12A112A*
·
·
Standing
NAXFKS15A112A*
·
·
NAXFKS18A112A*
·
EZ FIT®
NAXUKS09A112A*
·
·
Recessed Ceiling
NAXUKS12A112A*
·
·
Cassette
NAXUKS18A112A*
·
·
NAXAMT12A112A*
·*2
·*2
NAXAMT18A112A*
·*2
Multi-position Air Handler
NAXAMT24A112A*
NAXAMT30A112A*
NAXAMT36A112A*
NAXCKS09A112A*
·
·
Four-way Cassette
NAXCKS12A112A*
·
·
NAXCKS15A112A*
·
NAXDKS09A112A*
·
·
Horizontal-
NAXDKS12A112A*
·
·
ducted
NAXDKS15A112A*
·
·
NAXDKS18A112A*
·
PLA-A12EA7
PLA-A18EA7
·
Four-way Cassette
PLA-A24EA7 PLA-A30EA7
PLA-A36EA7
PLA-A42EA7
PCA-A24KA7
P-Series
Ceiling Suspended
PCA-A30KA7 PCA-A36KA7
PCA-A42KA7
PEAD-A12AA7
·*3
·*3
PEAD-A18AA7
·
Horizontalducted
PEAD-A24AA7 PEAD-A30AA7
PEAD-A36AA7
PEAD-A42AA7
Branch Box
3 port 5 port
PAC-MKA32BC PAC-MKA52BC
Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. A minimum of two indoor units must be connected to all MX outdoor units. *2 Only one AMT Model can be connected. *3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. *4 Single unit can be connected. *5 When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectable indoor units is decreased as follows: 3 for NAXMPH36A142BA, 4 for NAXMPH42A152BA, and 6 NAXMMX48A182BA, NAXMPH48A182BA, and NAXMMX60A182BA.
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·*2
·*3, 4
·*3, 4
·*3, 4
·*2
·*3, 4
·*3, 4
·*3, 4
·*2
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·*3, 4
·
·
·
·
·
·
·
·
·
·
·
·
·
·*6
·*6
·*6
·
·*6
·*6
·*6
·
·*6
·*6
·*6
·
·*6
·*6
·*6
·*5
·*5
·*5
·
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·*5
·
·*3
·*6
·*6
·*6
·*3
·*6
·*6
·*6
·
·*6
·*6
·*6
·*6
·*6
·*6
·*6
·*6
·*6
·
·
·
·
*6 Maximum of 3 Horizontal-ducted indoor units (PEAD or DKS) can be connected. *7 Maximum of 2 Horizontal-ducted indoor units (PEAD or DKS) can be connected. For more information, please refer to the Service Manual, Application Note 1039 and the full compatibility chart on AmericanStandard.MyLinkDrive.com.
Multi-Zone Nv-Models
117
Conditions
Conditions for Specifications
Temperature conditions are based on AHRI 210/240.
Cooling Heating
Indoor Outdoor Indoor Outdoor
D.B. 80º F (27º C), W.B. 67º F (19º C) D.B. 95º F (35º C), W.B. 75º F (24º C) D.B. 70º F (21º C), W.B. 60º F (16º C) D.B. 17º F (-8º C), W.B. 15º F (-9º C)
Refrigerant piping length: 16 ft. The figures for total input are based on the following voltages.
Nv Series P Series MX Model
Series
Indoor unit -
Outdoor unit 208 / 230V · Single phase · 60Hz
Sound pressure level · The sound pressure measurement is conducted in an anechoic chamber. · The actual sound level depends on the distance from the unit and the acoustic environment.
How to Read a Model Name
1) M-Series MSZ-EF12NAW
M
M or S: M-Series
S= Wall-mounted, F= Compact floor-standing, E= Compact ceiling-concealed, S
L= 4- or 1-way cassette, U= Outdoor unit
Z
Z= Inverter heat pump, H= Fixed-speed heat pump, Y= Cooling only
E
Series
F
Generation
12 Rated cooling capacity (KBTU/H base)
N
208 / 230V · Single phase · 60Hz
A
A= R410A with new A control
W
HZ= Hyper Heating model, H= Anti -freeze heater equipped model/base heater,
S= Silver indoor unit, W= White indoor unit, B= Black indoor unit
2) P-Series PUZ-A18NKA
P
P Series
U
K= Wall-mounted, S= Floor-standing, L= 4 -way cassette, E= Ceiling-concealed, C= Ceiling-suspended, U= Outdoor unit
Z
Z= For heating and cooling, Y= Cooling only
A
A=Standard HA=Hyper heating
18 Rated cooling capacity (KBTU/H base)
N
208 / 230V · Single phase · 60Hz
K
Generation
A
A= A control
7
7= Generation
3) MXZ-C Model MXZ-4C36NAHZ
M
M Series
X
Multi-system outdoor unit (heat pump)
Z
Inverter heat pump
4
Maximum number of connectable indoor units
C
Generation
36 Rated cooling capacity (KBTU/H base)
N
208 / 230V · Single phase · 60Hz
A
A= R410A with new A control
HZ HZ= Hyper Heating model
Conditions 119
Piping Installation
Nv-Series
Single type
Series
Class < Outdoor unit >
Maximum Piping Length (ft) Total length (A)
NAXSPH
06/09/12
65
15/18
100
NA(X/Y)SST
09/12/15
65
18/24
100
NAXSMT
09/12/15/18
65
24
100
NAXSPF
09/12
65
15/18
100
NAXSKS/NAXSKH
09/12/15
65
18
100
24/30/36
100
Maximum Height Difference (ft) Outdoor unit - Indoor unit (H)
40 50 40 50 40 50 40 50 40 50 100
Maximum Number of Bends Total number 10 10 10 10 10 10 10 10 10 10 10
P-Series
Single type
Series PUY
PUZ
PUZ-HA PUZ-HA
Class < Outdoor unit>
12/18 24/30/36/42
12/18 24/30/36/42
24 30/36/42
Maximum Piping Length (ft) Total length (A) 165 225 100 165 165 245
Maximum Height Difference (ft) Outdoor unit - Indoor unit (H)
100
100 100 100
Maximum Number of Bends Total number 15 15 15 15 15 15
120 Conditions
MX Model
NAXMMX20A122AA
Maximum Piping Length
Indoor
b
units
Outdoor unit - Indoor unit (a,b)
82 ft.
Total length (a+b)
164 ft.
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b)
25
Total number (a+b)
50
a
Max. height difference
Outdoor unit
49 ft.
49 ft.
33 ft.
NAXMPH20A122AA
Maximum Piping Length
Indoor
b
units
Outdoor unit - Indoor unit (a,b)
82 ft.
Total length (a+b)
164 ft.
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b)
25
Total number (a+b)
50
a
Max. height difference
Outdoor unit
49 ft.
49 ft.
49 ft.
NAXMMX24A132AA, NAXMMX30A132AA NAXMPH24A132AA, NAXMPH30A132AA
Maximum Piping Length
Indoor
c
units
Outdoor unit - Indoor unit (a,b,c)
82 ft.
Total length (a+b+c)
230 ft.
Maximum Number of Bends
b
Outdoor unit - Indoor unit (a,b,c)
25
Total number (a+b+c)
70
a
Max. height difference
Outdoor unit
49 ft.
49 ft.
49 ft.
Conditions 121
MX Model
NAXMMX36A142AA
Maximum Piping Length
Indoor units
d
Outdoor unit - Indoor unit (a,b,c,d)
82 ft.
Total length (a+b+c+d)
230 ft.
c
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d)
25
Total number (a+b+c+d)
70
b
a
Max. height difference
Outdoor unit
49 ft.
49 ft.
49 ft.
NAXMMX42A152AA
Maximum Piping Length
Indoor units
e
Outdoor unit - Indoor unit (a,b,c,d,e)
82 ft.
Total length (a+b+c+d+e)
262 ft.
d
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d,e)
25
c
Total number (a+b+c+d+e)
80
b
a
Max. height difference
Outdoor unit
49 ft.
49 ft.
49 ft.
122 Conditions
NAXMPH36A142AA, NAXMPH42A152AA, NAXMPH48A182AA, NAXMMX48A182AA, NAXMMX60A182AA
c1
D
b1
B
h2
H
h1
a1 a2 a3 a4
a5
CCC
h3
C
A Outdoor unit B Branch box C Indoor unit D
L
b2
B
I
a6 a7 a8
CC
C
Permissible length
(one-way)
Total piping length Farthest piping length (L) *1 Piping length between outdoor unit and branch boxes
Farthest piping length after branch box (l) Total piping length between branch boxes and indoor units
In indoor/outdoor section (H) *2 Permissible height difference In branch box/indoor unit section (h1) (one-way) In each branch unit (h2)
In each indoor unit (h3)
Number of bends
c1 + b1 + b2 + a1 + a2 + a3 + a4 + a5 + a6 + a7 + a8 150 m (492 ft.) c1 + b2 + a8 80 m (262 ft.) c1 + b1 + b2 55 m (180 ft.) b2 30 m (98 ft.) a8 25 m (82 ft.) a1 + a2 + a3 + a4 + a5 + a6 + a7 + a8 95 m (311 ft.) H 50 m (164 ft.) (In case of outdoor unit is set higher than indoor unit) H 40 m (131 ft.) (In case of outdoor unit is set lower than indoor unit) h1 + h2 15 m (49 ft.) h2 15 m (49 ft.) h3 12 m (39 ft.) | c1 + b1 + a1 |, | c1 + b1 + a2 |, | c1 + b1 + a3 |, | c1 + b1 + a4 |, | c1 + b1 + a5 |, | c1 + b2 + a6 |, | c1 + b2 + a7 |, | c1 + b2 + a8 | 15
*1 The
-
tent noise during normal system operation in very quiet environments. Please be aware of this important information when installing and locating the indoor unit within the
conditioned space.
*2 Branch box should be placed within the level between the outdoor unit and indoor units.
Conditions 123
Explanation of Terminology
Maximum Piping Length
This is the maximum allowable length of the refrigerant piping. The amount of refrigerant pipe used cannot be longer than the length specified. · Total Length
The maximum allowable combined length of all the refrigerant piping between the outdoor unit and indoor unit(s). · Outdoor Unit - Indoor Unit The maximum allowable length of the refrigerant piping between the outdoor unit and indoor units installed when multiple units are connected to a single outdoor unit. This distance limitation refers to the maximum length between the outdoor unit and the farthest indoor unit. · Pipe Length Difference From Distribution Pipe The maximum allowable difference in refrigerant piping length from the distribution pipe to the farthest indoor unit and from the distribution pipe to the closest indoor unit when multiple indoor units are connected to a single outdoor unit using a distribution pipe. · Indoor Unit - Distribution Pipe The maximum allowable length of the refrigerant piping between indoor units and the distribution pipe when multiple indoor units are connected to a single outdoor unit.
Maximum Height Difference
This is the maximum allowable height difference. It is necessary to install the air conditioning system so that the height distance is no more than the difference specified. (Specified differences may vary if the outdoor unit is installed higher or lower than the indoor units). · Outdoor Unit - Indoor Unit
The maximum allowable difference in height between the outdoor unit and indoor units when installed (when multiple indoor units are connected to a single outdoor unit, this distance limitation refers to the maximum height difference between the outdoor unit and an indoor unit). · Indoor Unit - Indoor Unit The maximum allowable difference between the heights of indoor units when multiple indoor units are connected to a single outdoor unit.
Maximum Number Of Bends
This is the maximum allowable number of bends in the refrigerant piping. The total number of bends in the refrigerant piping used cannot exceed the number specified. · Total Number
The maximum allowable number of bends for all refrigerant piping between the outdoor unit and indoor units. · Outdoor Unit - Indoor Unit The maximum allowable number of bends between the outdoor unit and each indoor unit when multiple indoor units are connected to a single outdoor unit.
124 Conditions
Appendix
3 Important Points to Remember When Installing the Outdoor Unit
Wind and snow can significantly reduce capacity. Be sure to check the information below and install the outdoor unit correctly.
1 Installation Location
Be aware of the prevailing wind direction in winter and install the outdoor unit where it is as sheltered as possible.
Units are easily affected by wind and unit may not be able to run at full capacity
Less influence of wind and unit runs at full capacity
2 Measures for Drainage of Water
Case 1: Unit is installed close to passage (walkway)
Do not install the unit close to passage as drainage water from the unit may freeze and cause a slipping hazard.
Correct installation
Wrong installation
Wrong installation
Note
Install at a sufficient height from the ground to prevent problems caused by frozen drainage water. Install in a location where frozen drainage water will not be a hazard. Install in an upright position to allow proper drainage from the drainage outlet.
Drainage water splashes on pedestrians.
Unit may freeze and become damaged because water will not be drained from the drain hole.
Frozen drainage water may cause a slipping hazard.
Case 2: Multiple units are installed
Do not install units on top of one another as it may cause frozen drainage water on the bottom unit.
Correct installation
Note
Place units side by side.
Wrong installation
Bottom unit may freeze.
Appendix 127
3 Measures for Snow
Do not install the unit on the ground
To avoid the adverse effects of snow and frozen drainage water, install the unit on a stand to ensure a sufficient height from the ground.
Correct installation
Note
Install at a position/height to prevent the unit being buried in snow*1 and the adverse effects of frozen drainage water.*2 Install so as to avoid the effects of snow or snowdrift. Install so as to avoid the damage from falling snow or icicles.
*1 Install at a height above the highest snowfall depth. *2 Even for correct installations, dripping drainage water may
form an icicle which needs to be cleared away regularly to prevent a blocked drainage outlet.
Wrong installation
Wrong installation
Unit may become buried in snow due to heavy snowfall, snow sliding off the roof or snowdrift.
Unit may be damaged due to snowfall or icicles.
Use a stand to add sufficient height to protect the unit heat exchanger from snow and prevent icicles forming during defrost operation.
Correct installation
Minimum height (h) should be higher than the highest snowfall depth (h0)
+7.8 in.
Air intake snow hood (side panel)
h
Air exhaust snow hood
Air intake snow hood (rear)
h0
Wrong installation
Unit may become covered in snow if the stand height is insufficient.
Stand height h
Without hood
Snowfall height h0 Stand is too low.
Install snow protection hood as necessary
Correct installation
Note
Install the snow protection hood or other cover in snowy regions.
Recommended accessories (drain socket & centralized drain pan, stand, snow protection hood, base heater)
Drain socket, Centralized drain pan
Stand
Snowy region Countermeasures
for snow Not used
Needed
Cold region Countermeasures
for freezing Not used
Needed
Remarks
Prevents freezing
1. Install so as to prevent the unit being buried
Clearance to prevent snow accumulating.
in snow (at a height greater than the highest
snowfall depth). Be sure that the stand does
not obstruct drainage. 2. Install so as to prevent damage to the unit
< Correct >
due to frozen drainage water (icicles).
Snow protection hood
Needed
*When the installation
--
position is subject to
snowfall.
1. Prevents heat exchanger from being covered in snow. 2. Prevents snow accumulating inside the air duct.
Base heater
Outdoor units equipped with a heater for cold regions are those with an"H"
--
Needed
in the model name. For the cold-climate zone, use of a unit with a heater is strongly recommended. Even for the moderate-climate zone use of a unit with
a heater is recommended for regions subject to high humidity in winter.
CAUTION About disposal of drainage water
When the unit is installed in cold or snowy regions :
Drainage water may freeze in the drain socket/hose and prevent the fan from rotating.
Do not attach a drain socket packaged as an accessory to the unit.
In the case that fitting a drain socket is absolutely necessary, steps must be taken so that the drainage water does not freeze. For more information, please consult Mitsubishi Electric Trane HVAC US or one of its dealers/resellers.
Arrangement for snow protection hood
Separately sold parts are available for some models. Please consult Mitsubishi Electric Trane HVAC US or one of its dealers/resellers at the time of purchase for details.
128 Appendix
System Control
Versatile system controls can be achieved by using optional parts, relay circuits, control panels, etc.
Indoor Unit Outdoor Unit
Nv Series Indoor Unit Nv Series and MX Series Outdoor
System Examples DKS, CKS, AMT SKS and MX Series Outdoor
P Series Indoor Unit P Series Outdoor
TAR-40MAAU Control
MAC-334IF-E Indoor unit
Outdoor unit
AAR-40MAAU
Indoor unit
AAR-40MAAU Outdoor unit
Details
· Wired remote controller can be connected to indoor unit
Standard equipment (for indoor units compatible with wired remote controllers)
Major Optional Parts Required
· MAC-334IF-E (Interface) · AAR-40MAAU (Wired remote controller)
· AAR-40MAAU (Wired remote controller)
System Group Control
Indoor unit
Indoor unit MAC-334IF-E
Indoor unit
Indoor unit MAC-334IF-E
Outdoor unit
Outdoor unit
AAR-40MAAU
Outdoor unit
Outdoor unit
AAR-40MAAU
Indoor unit
Indoor unit
Outdoor unit
AAR-40MAAU Outdoor unit
Details
· One remote controller can control plural air conditioners with the same settings simultaneously. · One remote controller can control up to 16 refrigerant systems. (When connected to a MX unit, MAC-334IF-E is counted as one system.) · Up to two remote controller can be connected.
Major Optional Parts Required
· MAC-334IF-E (Interface) · AAR-40MAAU (Wired remote controller)
· AAR-40MAAU (Wired remote controller)
M-NET Connections
Outdoor unit
Outdoor unit
Indoor unit
MAC-334IF-E ME remote controller (PAR-F27MEA)
City Multi indoor unit
MELANS system controller (AE-200A etc)
PAC-SC51KUA Power supply unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
AAR-40MAAU
AAR-40MAAU
City Multi indoor unit
PAC-SC51KUA Power supply kit
Indoor unit
AAR-40MAAU PAC-YT53CRAU
Indoor unit AAR-40MAAU
MAC-334IF-E
MELANS system controller (AE-200A etc)
PAC-SC51KUA Power supply unit
MELANS system controller (AE-200A etc)
Outdoor unit
Outdoor unit
M-NET adapter PAC-SF83MA-E
Details
· Group of air conditioners can be controlled by MELANS system controller (M-NET). Note: When connecting to M-NET, the reduction control for the power failure automatic recovery does not operate and it will take 3 minutes to restart.
Major Optional Parts Required
· MAC-334IF-E (M-NET Interface) · MELANS System controller · PAC-SC51KUA (power supply unit)
· PAC-SJ95MA-E/PAC-SJ96MA-E (M-NET converter)
· MELANS System controller · PAC-SC51KUA (power supply unit)
Appendix 129
For Nv-Series Indoor Units
System Examples
Connection Details
Control Details
Major Optional Parts Required
1
Remote On/Off Operation
· Air conditioner can be started/ stopped remotely.
( 1 and 2 can be used in
combination)
MAC-334IF-E
Indoor unit Outdoor unit
Switch
Remote control section (to be purchased locally)
Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.
On/Off operation is possible from a remote location.
· MAC-334IF-E (Interface) · Parts for circuit such as relay
box, lead wire, etc. (to be purchased locally)
2
Remote Display of Operation Status
· The On/Off status of air conditioners can be confirmed remotely.
( 1 and 2 can be used in
combination)
MAC-334IF-E
Power supply
Indoor unit Outdoor unit
Resistance LED
Remote monitor section (to be purchased locally)
Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.
The operation status (On/Off) or error signals can be monitored from a remote location.
· MAC-334IF-E (Interface) · Parts for circuit to be
purchased locally (DC power source needed) · External power source (12V DC) is required when using MAC-334IF-E.
For P-Series and CKS, DKS and AMT Indoor Units
A
2-remote Controller Control
With two remote controllers, control can be performed locally
and remotely from two locations.
B
Operation Control by Level Signal
Air conditioner can be started/ stopped remotely. In addition,
On/Off operation by local remote
controller can be prohibited/permitted.
C
Operation Control by Pulse Signal
D
Remote Display of Operating Status
Operating status can be displayed at a remote location.
E Timer Operation
Allows On/Off operation with timer *For control by an external
timer, refer to B Operation Control by Level Signal.
System Examples
Wired remote controller
Wireless remote controller
Details
Major Optional Parts Required
AAR-40MAAU
* Set "Main" and "Sub" remote controllers.
(Example of 1 : 1 system)
PAR-FL32MA
AAR-40MAAU
* When using wired and wireless remote controllers
(Example of Simultaneous Twin)
· Up to two remote controllers can be connected to one group.
· Both wired and wireless remote controllers can be used in combination.
· Wired Remote Controller AAR-40MAAU
· Wireless Remote Controller PAR-FL32MA
· Wireless Remote Controller Kit for PCA PAR-SL93B-E
Relay box (to be purchased) locally)
Adapter for remote On/Off
Remote control panel
Wired remote controller
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
Adapter for remote On/Off
Remote control panel
PAR-FL32MA
(Example of 1 : 1 system x 2)
· Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.
· Timer control is possible with an external timer.
· Adapter for remote On/Off PAC-SE55RA-E
· Relay box (to be purchased locally) · Remote control panel (to be
purchased locally)
Relay box (to be purchased) locally)
Connector cable for remote display
Relay box (to be purchased locally)
Connector cable for remote display
· The pulse signal can be turned On/Off. · Operation/emergency signal can be
received at a remote location.
Remote control panel
Wired remote controller
(Example of 1 : 1 system x 2)
Remote control panel
PAR-FL32MA
(Example of 1 : 1 system x 2)
· Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E)
· Relay box (to be purchased locally) · Remote control panel (to be
purchased locally)
Remote operation adapter/ Connector cable for remote display + Relay box
Remote operation adapter/ Connector cable for remote display +
· Operation/emergency signal can be
Relay box
received at a remote location (when
channeled through the PAC-SF40RM-E
no-voltage signal, when channeled
through the PAC-SA88HA-E DC 12V
signal).
Remote display panel
AAR-40MAAU (Example of 1 : 1 system)
Remote display panel
PAR-FL32MA
(Example of Simultaneous Twin)
· Remote display panel (to be purchased locally)
· Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E)
· Relay box (to be purchased locally) · Remote operation adapter
PAC-SF40RM-E
*Unable to use with wireless remote controller
AAR-40MAAU (Example of 1 : 1 system)
· Weekly Timer: On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)
· On/Off Timer: On/Off can be set once each within 72 hr in intervals of 5-minute units.
· Auto-off Timer: Operation will be switched off after a certain time elapse. Set time can be changed from 30 min. to 4 hr. at 10 min. intervals.
*Simple Timer and Auto-off Timer cannot be used at the same time.
Standard functions of AAR-40MAAU
130 Appendix
Other Optional Parts
Part Name
Deodorizing Filter
Captures small foul-smelling substances in the air.
Description
Deodorising filter
Air cleaning Filter
Removes fine dust particles from the air by means of static electricity.
Silver-ionized Air Purifier Filter
Captures the bacteria, pollen and other allergens in the air and neutralizes them.
Air cleaning filter
Silver-ionized Air Purifier Filter
Oil Mist Filter Element
Filter element (12 pieces) that blocks the oil mist for ceiling-suspended models used in professional kitchens.
Filter frame Filter element
High-efficiency Filter Element
Element for high-efficiency filter. Removes fine dust particles from the air.
Oil mist filter
Plug (for directing airflow)
High-efficiency filter element *For 4-way cassette units (PLA)
Shutter Plate
Plate for blocking an air outlet of the 4-way cassette (PLA) indoor unit.
Shutter Plate
Part Name
MAC-334IF-E System Control Interface
Interface for connecting with the PAR-40MAAU remote controller and PACYT53CRAU, and to relay operation signals.
Interface to connect with M-NET controllers.
kumo cloud® Wireless Interface 2
Interface enabling users to control air conditioners and check operating status via devices such as personal computers, tablets and smart phones.
CN24 Relay Kit
This product is an adaptor which inputs the incoming signals from an open/close switch to the air conditioner and outputs the on/off signals from the air conditioner to the back-up heater.
Deluxe MA Wired Controller
Advanced deluxe remote controller with full dot liquid-crystal display and backlight. Equipped with convenient functions like
Simple MA Wired Controller
Remote controller with liquid-crystal display, and backlight function for operation in dark location.
Description
Indoor unit
MAC-334 System Control Interface
Indoor unit
MAC-334IF-E
Indoor unit
Wireless Interface 2
Indoor unit
Smartphone Switch
Relay
Multi-functional Casement
Casement for fresh-air intake and attaching the high-efficiency filter element (optional).
Indoor unit body
Multi-functional casement
Space Panel
Decorative cover for the installation when the ceiling height is low.
Space Panel
Panel
Drain Pump
Pumps drain water to a point higher than that where the unit is installed.
*for ceiling-suspended units
Drain pump
Remote Controller Terminal Block Kit for PKA
The terminal block is used as a relay to wire an indoor unit and to two remote controllers or to wire a remote controller and multiple indoor units in order to perform group control.
Wireless Remote Controller Signal Sender
Handheld unit for sending operation signals to the indoor unit.
Handheld unit
Wireless Remote Controller Signal Receiver
Receives operation signals from the wireless remote controller handheld unit.
Signal receiver
132 Appendix
Part Name
Wireless Remote Controller Kit (Sender & Receiver)
Remote controller handheld unit (signal sender) and receiver (signal receiver) for ceiling suspended units.
Description
Signal receiver
Signal sender
Part Name
Air Protection Guide/ Wind Baffle
Protects the outdoor unit from the wind.
Description
Control Holder
Holder for storing the remote controller.
Control holder
Remote Sensor
Sensor to detect the room temperature at remote positions.
PAC-715AD Remote On/Off Adapter
Connector for receiving signals from the local system to control the on/off function.
PAC-USSEN001-FM-1 Remote on/off adapter
Drain Socket
A set of caps to cover unnecessary holes at
the bottom of the outdoor unit, and a
socket to guide drain water to the local
Cap
drain pipe.
Socket
Centralized Drain Pan
Catches drain water generated by the outdoor unit.
Outdoor unit Centralized drain pan
Base (local construction)
M-NET Converter
Used to connect P Series A-control models to M-NET controllers.
Group remote controller
Power supply unit for transmit cable
M-NET Converter
Remote Operation Adapter
Adapter to display the operation status and control on/off function from a distance.
Remote operation adapter
Control/Service Tool
Monitoring tool to display operation and self-diagnosis data.
PAC-725AD Connector Plug for Remote Display
Connector used to display the operation status and control on/off function from a distance.
Connector cable for remote display
Air Discharge Guide
Changes the direction of air being exhausted from the outdoor unit.
Control/service tool
Distribution Pipe
Branch pipe for P Series simultaneous multi-system use, or to connect two branch boxes for MX.
Joint Pipe
Part for connecting refrigerant pipes of different diameters.
Indoor unit
Indoor unit
Distribution pipe
Outdoor unit
*P Series with 2 indoor units
Indoor unit
Joint pipe
Onsite pipe
Insulator
Outdoor unit
Branch Box Outer Cover
Casement for branch boxes.
Complete view Branch box outer cover
Appendix 133
NAXWPH06B112AA NAXWPH09B112AA NAXWPH12B112AA NAXWPH15B112AA NAXWPH18B112AA MSZ-EF09NA(B/S/W) MSZ-EF12NA(B/S/W) MSZ-EF15NA(B/S/W) MSZ-EF18NA(B/S/W)
Optional Parts List for Indoor [Nv-Series]
NAXWPH
Wall Mount
MSZ-EF
Condensate
Disconnect Switch Filter Lineset
Soft Dry Cloth
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit Sauermann Condensate Pump (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White
Electro Static Anti-allergy Enzyme Filter
Platinum Deodorizing Filter 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) Soft Dry Cloth
X87-721
X85-003
C13-192
C21-014
C13-103 SS610E
T18-016
SI30-230 TAZ-MS303 TAZ-MS303W MAC-2320FT-E MAC-2330FT-E MAC-3000FT-E MLS141212T-100 MLS141212T-15 MLS143812T-15 MLS141212T-30 MLS143812T-30 MLS141212T-50 MLS143812T-50 MLS141212T-65 MLS143812T-65 MAC-1001CL-E
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
134 Appendix
NAXWST06A112AA NAXWST09A112AA NAXWST12A112AA NAXWST15A112AA NAXWST18A112AA NAXWST24A112AA NAXWST30A112AA NAXWST36A112AA
Wall Mount NAXWST
Condensate
Controller Holder Disconnect Switch
Filter
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit Sauermann Condensate Pump Remote Controller Holder (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Anti-allergy Enzyme Filter Electro Static Anti-allergy Enzyme Filter 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)
X87-721
X87-835
X85-003
C13-192
C21-014
C13-103 SS610E
T18-016
SI30-230 U01A01083 TAZ-MS303 TAZ-MS303W MAC-408FT-E MAC-2310FT-E MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MLS143812T-15 MPLS385812T-15 MLS141212T-30 MLS143812T-30 MPLS385812T-30 MLS141212T-50 MLS143812T-50 MPLS385812T-50 MLS141212T-65 MLS143812T-65 MPLS385812T-65
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 135
NAXWMT09A112AA NAXWMT12A112AA NAXWMT15A112AA NAXWMT18A112AA NAXWMT24A112AA NAXWMT09A111AA NAXWMT12A111AA NAXWEL09A112AA NAXWEL12A112AA NAXWEL18A112AA NAXWEL24A112AA
Optional Parts List for Indoor [Nv-Series]
Wall Mount NAXWMT
NAXWEL
Condensate
Controller Holder Disconnect Switch
Filter
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit Sauermann Condensate Pump Remote Controller Holder (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Anti-allergy Enzyme Filter 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)
X87-721
X87-835
X85-003
C13-192
C21-014
C13-103 SS610E
T18-016
SI30-230 U01A01083 TAZ-MS303 TAZ-MS303W MAC-408FT-E MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MLS143812T-15 MPLS385812T-15 MLS141212T-30 MLS143812T-30 MPLS385812T-30 MLS141212T-50 MLS143812T-50 MPLS385812T-50 MLS141212T-65 MLS143812T-65 MPLS385812T-65
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
·
·
·
·
·
·
·
··
·
·
·
·
·
·
·
·
·
··
·
·
·
·
·
·
·
·
·
··
·
·
·
·
·
·
·
·
·
··
·
·
136 Appendix
NAYWST09A112AA NAYWST12A112AA NAYWST15A112AA NAYWST18A112AA NAYWST24A112AA NAYWST30A112AA NAYWST36A112AA
Wall Mount NAYWST
Condensate
Controller Holder Disconnect Switch
Filter
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit Sauermann Condensate Pump Remote Controller Holder (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Anti-allergy Enzyme Filter Electro Static Anti-allergy Enzyme Filter 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)
X87-721
X87-835
X85-003
C13-192
C21-014
C13-103 SS610E
T18-016
SI30-230 U01A01083 TAZ-MS303 TAZ-MS303W MAC-408FT-E MAC-2310FT-E MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MLS143812T-15 MPLS385812T-15 MLS141212T-30 MLS143812T-30 MPLS385812T-30 MLS141212T-50 MLS143812T-50 MPLS385812T-50 MLS141212T-65 MLS143812T-65 MPLS385812T-65
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 137
NAXFKS09A112AA NAXFKS12A112AA NAXFKS15A112AA NAXFKS18A112AA NAXUKS09A112AA NAXUKS12A112AA NAXUKS18A112AA
Optional Parts List for Indoor [Nv-Series]
Floor-mount Recessed NAXFKS
One-way Cassette NAXUKS
Condensate
Disconnect Switch Filter
Floor Mount Air Guide Grille
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Sauermann Condensate Pump (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Anti-allergy Enzyme Filter Floor Mount Air Guide Grille 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation)
X87-721
X85-003
C13-192
C21-014
C13-103 SS610E SI30-230 TAZ-MS303 TAZ-MS303W MAC-408FT-E MAC-760FD-E ALP-444W MLS141212T-100 MLS141212T-15 MLS143812T-15 MLS141212T-30 MLS143812T-30 MLS141212T-50 MLS143812T-50 MLS141212T-65 MLS143812T-65
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
138 Appendix
NAXCKS09A112AA NAXCKS12A112AA NAXCKS15A112AA NAXCKS18A112AA NAXDKS09A112AA NAXDKS12A112AA NAXDKS15A112AA NAXDKS18A112AA NAXAMT12A112AA NAXAMT18A112AA NAXAMT24A112AA NAXAMT30A112AA NAXAMT36A112AA
Four-way Cassette NAXCKS
Ducted NAXDKS
Residential Multi-position AHU NAXAMT
Bottom Return Plate
Condensate
Control Wire Disconnect Switch
Downflow Kit Electric Heat Lockout
Electric Kit Heats Filter Box Grille
i-see Sensor® Panel
Lineset
Terminal Block
Converts low-profile ducted unit from rear to bottom
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Alarm Extension Cable--6.5 Ft. Blue Diamond MultiTank -- collection tank for use with multiple pumps Blue Diamond Sensor Extension Cable -- 15 Ft. Sauermann Condensate Pump 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White
Downflow Kit
Electric Heat Lockout 10kW Electric Heater 3kW Electric Heater
5kW Electric Heater
8kW Electric Heater
Filter Box with MERV 8 Filter
Grille 3D i-see Sensor® Corner Panel Grille with 3D i-see Sensor® 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) Separate Terminal Power Block
BRP1 BRP2 BRP3
X87-721
X87-835
X85-003
C13-192
C21-014
C13-103 SI30-230
CW2042S2-100
CW2042S2-500 TAZ-MS303 TAZ-MS303W DFK-M DFK-S ETC-211000-MIT EH10-SVZ-M EH03-SVZ-S EH05-SVZ-M EH05-SVZ-S EH08-SVZ-M EH08-SVZ-S FBL1-1 FBL1-2 FBL1-3 ALP-18FAU PAC-SF1ME-E ALP-18FAEU MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MLS143812T-15 MPLS385812T-15 MLS141212T-30 MLS143812T-30 MPLS385812T-30 MLS141212T-50 MLS143812T-50 MPLS385812T-50 MLS141212T-65 MLS143812T-65 MPLS385812T-65 SPTB1
·
·
·
·
·
·
·
·
·
·
·
· ·····
···
·
·
·
·
·
·
·
· ··
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
·
·
·
·
· ·····
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
··
···
·····
··
···
··
···
··
··
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
···
·
·
·
·
·
···
·
·
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
·
·
···
·····
Appendix 139
PKA-A12HA7 PKA-A18HA7 PKA-A24KA7 PKA-A30KA7 PKA-A36KA7 PCA-A24KA7 PCA-A30KA7 PCA-A36KA7 PCA-A42KA7
Optional Parts List for Indoor [P-Series]
Wall Mount PKA
Ceiling-suspended PCA
Condensate
Disconnect Switch Drain Pump Filter
i-see Sensor® Panel
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Sensor Extension Cable -- 15 Ft. Drain Pan Level Sensor/Control Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit Sauermann Condensate Pump (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Drain Pump Kit
65% Medium Efficiency Filter (MERV 8)
High Efficiency (MERV 8) Filter Element i-see Sensor® 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)
X87-721
X87-835
X85-003
C13-103 SS610E
T18-016
SI30-230 TAZ-MS303 TAZ-MS303W PAC-SH84DM-E PAC-SH89KF-E PAC-SH90KF-E PAC-SE81KF-E PAC-SH91MK-E MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MPLS385812T-15 MLS141212T-30 MPLS385812T-30 MLS141212T-50 MPLS385812T-50 MLS141212T-65 MPLS385812T-65
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
140 Appendix
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7 PVA-A12AA7 PVA-A18AA7 PVA-A24AA7 PVA-A30AA7 PVA-A42AA7
Four-way Cassette PLA
Residential Multi-position AHU PVA
Casement Condensate
Control Wire Disconnect Switch
Downflow Kit Electric Heat Lockout
Electric Kit Heats
Filter i-see Sensor® Panel
Lineset
Shutter Plate Space Panel Terminal Block
Multi-function Casement Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H Blue Diamond Sensor Extension Cable -- 15 Ft. 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White Condensate Management Kit for downflow installation Electric Heat Lockout
10kW Electric Heater
15kW Electric Heater 17kW Electric Heater
3kW Electric Heater
5kW Electric Heater
5kW Electric Heater Module-Medium Cabinet
8kW Electric Heater
High Efficiency Filter Element Grille with 3D i-see Sensor® 10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation) Drain Pan Architectural Surround for Ceiling Recessed Units Space Panel Separate Terminal Power Block
PAC-SJ41TM-E
X87-721
X87-835
X85-003
C13-103
CW2042S2-100
CW2042S2-500 TAZ-MS303 TAZ-MS303W CMA-1 ETC-211000-MIT EH10-MPA-LB EH10-MPA-MB EH15-MPAS-LB EH17-MPAS-LB EH03-MPA-MB EH03-MPA-SB EH05-MPA-MB EH05-MPA-SB EH05-MPA-M EH08-MPA-MB EH08-MPA-SB PAC-SH59KF-E PLP-41EAEU MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MPLS385812T-15 MLS141212T-30 MPLS385812T-30 MLS141212T-50 MPLS385812T-50 MLS141212T-65 MPLS385812T-65 PAC-SJ37SP-E PLFY-ITP1 PAC-SJ38AS-E SPTB1
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 141
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 PEAD-A42AA7
Optional Parts List for Indoor [P-Series]
Ducted PEAD
Condensate Control Wire Disconnect Switch
Filter Box
Lineset
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor Blue Diamond Sensor Extension Cable -- 15 Ft. 20/2PR, 1PR shielded + 1PR plenum wire for Airzone, 100 ft reel 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel (30A/600V/UL) [fits 2" X 4" utility box] - Black (30A/600V/UL) [fits 2" X 4" utility box] - White
Filter Box with MERV 13 Filter
10' x 3/8" x 10' x 5/8" Lineset (Twin-Tube Insulation) 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation) 100' x 3/8" x 100' x 5/8" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation) 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) 15' x 3/8" x 15' x 5/8" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) 30' x 3/8" x 30' x 5/8" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) 50' x 3/8" x 50' x 5/8" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) 65' x 3/8" x 65' x 5/8" Lineset (Twin-Tube Insulation)
X87-721
X87-835
C13-103
CW2042S2-100
CW2042S2-500 TAZ-MS303 TAZ-MS303W FBM2-2-A FBM2-3-A FBM2-4-A MPLS385812T-10 MLS141212T-100 MPLS385812T-100 MLS141212T-15 MLS143812T-15 MPLS385812T-15 MLS141212T-30 MLS143812T-30 MPLS385812T-30 MLS141212T-50 MLS143812T-50 MPLS385812T-50 MLS141212T-65 MLS143812T-65 MPLS385812T-65
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
142 Appendix
Optional Parts List for Outdoor [Nv-Series]
NAXSPH
NAXSPB
NAXSPH06B112AA NAXSPH09B112AA NAXSPH12B112AA NAXSPH15B112AA NAXSPH18B112AA NAXSPB06B112AA NAXSPB09B112AA NAXSPB12B112AA NAXSPB15B112AA NAXSPB18B112AA
Air Outlet Guide Control/Service Tool
Drain Socket
Air Outlet Guide M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection)
Drain Socket
Hail Guards
Hail Guard
Mini-Split Wire Mounting Pad Optional Defrost Heater
Stand
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Base Heater Optional Defrost Heater 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish Outdoor Unit Stand -- 12" High
MAC-881SG M21EC0397
M21EC1397
MAC-811DS MAC-871DS HG-A7 HG-B4 S144-250 S144-50 S164-250 S164-50 ULTRILITE1 DSD-400P MAC-642BH-U1 MAC-640BH-U QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
NAXSST
NAXSMT
Air Outlet Guide
Control/Service Tool Controller Holder
Drain Socket
Air Outlet Guide
M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Remote Controller Holder
Drain Socket
Hail Guards
Hail Guard
Mini-Split Wire
Mounting Pad Optional Defrost Heater
Power Supplies And Auxiliary Components
Stand
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Base Heater Optional Defrost Heater M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish Outdoor Unit Stand -- 12" High
MAC-881SG MAC-886SG-E M21EC0397
M21EC1397
U01A01083 MAC-811DS MAC-871DS HG-A7 HG-B4 S144-250 S144-50 S164-250 S164-50 ULTRILITE1 DSD-400P MAC-642BH-U1 MAC-640BH-U
CW162S-250
QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M
·
·
·
···
·
·
·
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
·····
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
·
·
·
·
·
·
·
···
·
NAXSST09A112AB NAXSST12A112AB NAXSST15A112AB NAXSST18A112AA NAXSST24A112AA NAXSST30A112AA NAXSST36A112AA NAXSMT09A112AB NAXSMT12A112AB NAXSMT15A112AB NAXSMT18A112AB NAXSMT24A112AA
144 Appendix
NAYSST09A112AB NAYSST12A112AB NAYSST15A112AB NAYSST18A112AA NAYSST24A112AA NAYSST30A112AA NAYSST36A112AA NAXSPF09A112AA NAXSPF12A112AA NAXSPF15A112AA NAXSPF18A112AA
NAYSST
NAXSPF
Air Outlet Guide Control/Service Tool
Drain Socket
Air Outlet Guide
M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection)
Drain Socket
Hail Guards Mini-Split Wire Mounting Pad
Stand
Hail Guard
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish Outdoor Unit Stand -- 12" High
MAC-881SG MAC-886SG-E M21EC0397
M21EC1397
MAC-811DS MAC-871DS HG-A7 HG-B4 S144-250 S144-50 S164-250 S164-50 ULTRILITE1 DSD-400P QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
NAXSEL
NAXSMT
NAXSEL09A112AB NAXSEL12A112AB NAXSEL18A112AB NAXSEL24A112AA NAXSMT09A111AA NAXSMT12A111AA
Air Outlet Guide Air Outlet Guide
Control/Service Tool Drain Socket
M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Drain Socket
Hail Guards
Hail Guard
Mini-Split Wire Mounting Pad Optional Defrost Heater
Stand
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Base Heater Optional Defrost Heater 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish Outdoor Unit Stand -- 12" High
MAC-881SG MAC-886SG-E M21EC0397
M21EC1397
MAC-871DS HG-A7 HG-B4 S144-250 S144-50 S164-250 S164-50 ULTRILITE1 DSD-400P MAC-642BH-U1 MAC-640BH-U QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 145
NAXMMX20A122A* NAXMMX24A132A* NAXMMX30A132A* NAXMMX36A142A* NAXMMX42A152A* NAXMMX48A182B* NAXMMX60A182B* NAXMPH20A122A* NAXMPH24A132A* NAXMPH30A132A* NAXMPH36A142B* NAXMPH42A152B* NAXMPH48A182B*
Optional Parts List for Outdoor [Nv-Series]
NAXMMX
NAXMPH
Air Outlet Guide
Ball Valve
Branch Box Centralized Drain Pan Control/Service Tool Distribution pipe for
Branch Box Drain Socket
Hail Guards
Mini-Split Wire
Mounting Pad Optional Defrost Heater
Port Adapter Power Supplies and Auxiliary Components Power Supplies And Auxiliary Components
Stand
Wind Baffle
Air Outlet Guide
PAC-ADG856AA-E PAC-SJ07SG-E
Air Outlet Guide (1 Piece)
PAC-ADG096AA-E
Refrigeration Ball Valve - 1/2"
BV12FFSI2
Refrigeration Ball Valve - 1/4"
BV14FFSI2
Refrigeration Ball Valve - 3/8"
BV38FFSI2
Refrigeration Ball Valve - 5/8"
BV58FFSI2
Branch Box
TAC-MKA32BC TAC-MKA52BC
Branch Box Enclosure
BBE-1
Drain Pan
PAC-SH97DP-E
M- & P-Series Maintenance Tool Cable Set
M21EC0397
Maintenance Tool Interface
PAC-USCMS-MN-1
USB/UART Conversion Cable (Required for all laptop connection)
M21EC1397
Brazed Connection
MSDD-50BR-E
Flare Connection
MSDD-50AR-E
M-NET Converter
PAC-IF01MNT-E
MAC-811DS
Drain Socket
PAC-SG60DS-E
PAC-SG61DS-E
HG-A1
Hail Guard
HG-A2 HG-A8
HG-A9
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll
S144-250
14 Gauge, 4 wire MiniSplit Cable--50 ft. roll
S144-50
16 Gauge, 4 wire MiniSplit Cable--250 ft. roll
S164-250
16 Gauge, 4 wire MiniSplit Cable--50 ft. roll
S164-50
Condensing Unit Mounting Pad: 16" x 36" x 3"
ULTRILITE1
Condensing Unit Mounting Pad: 24" x 42" x 3"
ULTRILITE2
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic
DSD-400P
Base Heater
PAC-646BH-E
Optional Defrost Heater
PAC-645BH-E PAC-SJ20BH-E
Adaptor: 1/2" x 3/8"
MAC-A455JP-E
Adaptor: 1/2" x 5/8"
MAC-A456JP-E
Adaptor: 3/8" x 1/2"
MAC-A454JP-E
Adaptor: 3/8" x 5/8"
PAC-SG76RJ-E
M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated)
CW162S-1000 CW162S-250
18" Dual Fan Stand
QSMS1802M
18" Single Fan Stand
QSMS1801M
24" Dual Fan Stand
QSMS2402M
24" Single Fan Stand
QSMS2401M
Condenser Wall Bracket
QSWB2000M-1
Condenser Wall Bracket -Stainless Steel Finish
QSWBSS
Outdoor Unit Stand -- 12" High
QSMS1201M QSMS1202M
Front Wind Baffle
WB-PA3
·
·
·
·
·
·
· ······
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
· ·····
·
·
···
·
·
···
·
·
···
·
·
·
···
·
·
···
·
·
···
·
·
···
·
·
···
·
·
···
·
·
·
·
···
·
·
·
·
·
·
·
···
·
·
·
···
·
·
·
·
·
···
·
·
···
·
·
···
·
·
···
·
·
·
·
·
· ····
·
·
·
··
·
·
·
·
·
·
· ······
·
·
·
·
·
·
·
·
·
·
·
·
·
· ······
·
·
·
·
·
·
· ······
·
·
·
·
·
·
· ······
·
·
·
·
·
·
· ······
·
·
·
···
·
·
·
···
·
·
···
·
·
·
·
···
·
·
·
···
·
·
·
·
···
·
·
·
·
·
·
· ······
·
·
·
·
·
·
· ······
·
·
·
·
···
·
·
·
···
·
·
···
146 Appendix
NAXSKS09A112AA NAXSKS12A112AA NAXSKS15A112AA NAXSKS18A112AA NAXSKS24A112AA NAXSKS30A112AA NAXSKS36A112AA NAXSKH09A112AA NAXSKH12A112AA NAXSKH15A112AA NAXSKH18A112AA NAXSKH24A112AA NAXSKH30A112AA NAXSKH36A112AA
NAXSKS
NAXSKH
Air Outlet Guide
Air Outlet Guide Air Outlet Guide (1 Piece)
Centralized Drain Pan Drain Pan
Control/Service Tool Drain Socket
M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Drain Socket
Hail Guards
Hail Guard
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll
16 Gauge, 4 wire MiniSplit Cable--50 ft. roll
Mounting Pad Optional Defrost Heater
Port Adapter
Stand
Condensing Unit Mounting Pad: 16" x 36" x 3" Condensing Unit Mounting Pad: 24" x 42" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Base Heater Adaptor: 3/8" x 1/2" 18" Dual Fan Stand 18" Single Fan Stand 24" Dual Fan Stand 24" Single Fan Stand Condenser Wall Bracket
Outdoor Unit Stand -- 12" High
MAC-886SG-E PAC-ADG096AA-E PAC-SG59SG-E PAC-SG64DS-E PAC-SH97DP-E M21EC0397
M21EC1397
PAC-SH71DS-E HG-A2 HG-A6 HG-B4 S144-250 SW144-250 S144-50 SW144-50 S164-250 SW164-250 S164-50 SW164-50 ULTRILITE1 ULTRILITE2 DSD-400P MAC-642BH-U1 MAC-A454JP-E QSMS1802M QSMS1801M QSMS2402M QSMS2401M QSWB2000M-1 QSMS1201M QSMS1202M
····
·
··
·
·
··
· · · · · · · ·······
·······
··
···
··
·
···
· · · · · · · ····
··
· · · · · · · ····
· · · · · · · ····
··
· · · · · · · ····
· · · · · · · ····
··
· · · · · · · ····
· · · · · · · ····
··
· · · · · · ····
· · · · · · · ····
···
·······
····
·
·
·
··
· · · · · · · ·····
··
· · · · · · · ·····
· · · · · · · ····
· · · · · · · ·····
··
Appendix 147
PUY-A12NKA7(-BS) PUY-A18NKA7(-BS) PUY-A24NHA7(-BS) PUY-A30NHA7(-BS) PUY-A36NKA7(-BS) PUY-A42NKA7(-BS)
Optional Parts List for Outdoor [P-Series]
PUY
Air Outlet Guide
Air Outlet Guide Air Outlet Guide (1 Piece)
Centralized Drain Pan Control/Service Tool
Distribution pipe
Centralized Drain Pan Drain Pan Control/Service Tool M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Twinning Distribution Pipe (50:50)
Drain Socket
Drain Socket
Hail Guards
Hail Guard
M-NET Converter M-NET Converter
Mini-Split Wire Mounting Pad
Stand
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Condensing Unit Mounting Pad: 24" x 42" x 3" 18" Dual Fan Stand 18" Single Fan Stand 24" Dual Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish
Outdoor Unit Stand -- 12" High
Front Wind Baffle
Wind Baffle
Rear Wind Baffle
Side Advanced Wind Baffle
PAC-SJ07SG-E PAC-ADG096AA-E PAC-SG59SG-E PAC-SG63DP-E PAC-SG64DP-E PAC-SK52ST M21EC0397
M21EC1397
MSDD-50TR-E PAC-SG61DS-E PAC-SJ08DS-E HG-A5 HG-A6 PAC-SJ85MA-E PAC-SJ95MA-E PAC-SJ96MA-E S144-250 S144-50 S164-250 S164-50 ULTRILITE1 ULTRILITE2 QSMS1802M QSMS1801M QSMS2402M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M QSMS1202M WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
148 Appendix
PUZ-A12NKA7(-BS) PUZ-A18NKA7(-BS) PUZ-A24NHA7(-BS) PUZ-A30NHA7(-BS) PUZ-A36NKA7(-BS) PUZ-A42NKA7(-BS) PUZ-HA24NHA1 PUZ-HA30NKA PUZ-HA36NKA PUZ-HA42NKA1
PUZ
Air Outlet Guide
Air Outlet Guide Air Outlet Guide (1 Piece)
Centralized Drain Pan
Centralized Drain Pan Drain Pan
Control/Service Tool Distribution pipe
Control/Service Tool
M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Twinning Distribution Pipe (50:50)
Drain Socket
Drain Socket
Hail Guards
Hail Guard
M-NET Converter M-NET Converter
Mini-Split Wire Mounting Pad Optional Defrost Heater
Stand
14 Gauge, 4 wire MiniSplit Cable--250 ft. roll 14 Gauge, 4 wire MiniSplit Cable--50 ft. roll 16 Gauge, 4 wire MiniSplit Cable--250 ft. roll 16 Gauge, 4 wire MiniSplit Cable--50 ft. roll Condensing Unit Mounting Pad: 16" x 36" x 3" Condensing Unit Mounting Pad: 24" x 42" x 3" Optional Defrost Heater 18" Dual Fan Stand 18" Single Fan Stand 24" Dual Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket -Stainless Steel Finish
Outdoor Unit Stand -- 12" High
Front Wind Baffle
Wind Baffle
Rear Wind Baffle
Side Advanced Wind Baffle
PAC-SJ07SG-E PAC-ADG096AA-E PAC-SG59SG-E PAC-SG63DP-E PAC-SG64DP-E PAC-SH97DP-E PAC-SK52ST M21EC0397
M21EC1397
MSDD-50TR-E PAC-SG61DS-E PAC-SJ08DS-E HG-A2 HG-A5 HG-A6 PAC-SJ85MA-E PAC-SJ95MA-E PAC-SJ96MA-E S144-250 S144-50 S164-250 S164-50 ULTRILITE1 ULTRILITE2 PAC-SJ20BH-E QSMS1802M QSMS1801M QSMS2402M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M QSMS1202M WB-PA3 WB-PA4 WB-PA5 WB-RE4 WB-RE5 WB-RE6 WB-SD4 WB-SD5 WB-SD6
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 149
NAXWPH06B112AA NAXWPH09B112AA NAXWPH12B112AA NAXWPH15B112AA NAXWPH18B112AA MSZ-EF09NA(B/S/W) MSZ-EF12NA(B/S/W) MSZ-EF15NA(B/S/W) MSZ-EF18NA(B/S/W)
Optional Parts List for Controllers
NAXWPH
Wall Mount
MSZ-EF
BACnet® and Modbus Interface
CN24 Relay Kit
IT Extender
kumo station® for kumo cloud®
Control Interface Lockdown bracket for remote controller
System Control Interface
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Remote Sensor
Wired Remote Sensor Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
Wireless Remote Controller kumo touchTM RedLINKTM Wireless Controller
PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB MAC-334IF-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 M21EAA307 PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Wall Mount NAXWST
NAXWST06A112AA NAXWST09A112AA NAXWST12A112AA NAXWST15A112AA NAXWST18A112AA NAXWST24A112AA NAXWST30A112AA NAXWST36A112AA
BACnet® and Modbus Interface
IT Extender
kumo station® for kumo cloud®
Control Interface
Lockdown bracket for remote controller System Control Interface
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Remote Sensor
Wired Remote Sensor Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
Wireless Remote Controller kumo touchTM RedLINKTM Wireless Controller
PAC-UKPRC001-CN-1 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB MAC-334IF-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 M21EAA307 PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
150 Appendix
Wall Mount NAXWMT
NAXWEL
NAXWMT09A112AA NAXWMT12A112AA NAXWMT15A112AA NAXWMT18A112AA NAXWMT24A112AA NAXWMT09A111AA NAXWMT12A111AA NAXWEL09A112AA NAXWEL12A112AA NAXWEL18A112AA NAXWEL24A112AA
BACnet® and Modbus Interface
IT Extender
kumo station® for kumo cloud®
Control Interface
Lockdown bracket for remote controller System Control Interface
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Remote Sensor
Wired Remote Sensor Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
Wireless Remote Controller kumo touchTM RedLINKTM Wireless Controller
PAC-UKPRC001-CN-1 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB MAC-334IF-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 M21EAA307 PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
··
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
·
·
·
·
·
·
·
····
Wall Mount NAYWST
NAYWST09A112AA NAYWST12A112AA NAYWST15A112AA NAYWST18A112AA NAYWST24A112AA NAYWST30A112AA NAYWST36A112AA
BACnet® and Modbus Interface
IT Extender
kumo station® for kumo cloud®
Control Interface
Lockdown bracket for remote controller System Control Interface
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Remote Sensor
Wired Remote Sensor Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
Wireless Remote Controller kumo touchTM RedLINKTM Wireless Controller
PAC-UKPRC001-CN-1 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB MAC-334IF-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 M21EAA307 PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Floor-mount Recessed NAXFKS
One-way Cassette NAXUKS
NAXFKS09A112AA NAXFKS12A112AA NAXFKS15A112AA NAXFKS18A112AA NAXUKS09A112AA NAXUKS12A112AA NAXUKS18A112AA
BACnet® and Modbus Interface
CN24 Relay Kit
IT Extender
kumo station® for kumo cloud®
Control Interface Lockdown bracket for remote controller
System Control Interface
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Flush Mount Temperature Sensor
Remote Sensor
Wired Remote Sensor
Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
Wireless Remote Controller kumo touchTM RedLINKTM Wireless Controller
PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB MAC-334IF-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN001-FM-1 M21EAA307 PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 151
Optional Parts List for Controllers
Four-way Cassette NAXCKS
Ducted NAXDKS
Residential Multi-position AHU NAXAMT
NAXCKS09A112AA NAXCKS12A112AA NAXCKS15A112AA NAXCKS18A112AA NAXDKS09A112AA NAXDKS12A112AA NAXDKS15A112AA NAXDKS18A112AA NAXAMT12A112AA NAXAMT18A112AA NAXAMT24A112AA NAXAMT30A112AA NAXAMT36A112AA
3-Pin Connector
BACnet® and Modbus Interface
CN24 Relay Kit
Connector and wire for Operation status/error using CN51
Connector cable for remote display
Control Interface
IT Extender kumo station® for kumo cloud®
Lockdown bracket for remote controller
Remote Operation Adapter
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Flush Mount Temperature Sensor
Remote Sensor
Remote Temperature Sensor surface mount
Wireless temperature and humitity sensor for kumo cloud®
Airzone ZBS Wired Blueface Principal Controller White
Airzone ZBS Wired Lite Controller White
Airzone ZBS Wired Think Controller White
Airzone ZBS Wireless Lite Controller White Wired Remote Controller
Airzone ZBS Wireless Think Controller White
Deluxe Wired MA Remote Controller
Simple MA Remote Controller
Touch MA Controller
kumo touchTM RedLINKTM Wireless Controller
Wireless MA Receiver
Wireless Remote Controller Wireless MA Remote Controller
Wireless Receiver
Wireless Remote Contoller
PAC-715AD PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-725AD PAC-SA88HA-EP PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB PAC-SF40RM-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN001-FM-1 PAC-SE41TS-E PAC-USWHS003-TH-1 AZZBSBLUEFACECB AZZBSLITECB AZZBSTHINKCB AZZBSLITERB AZZBSTHINKRB AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2 PAR-SR32MA-E PAR-FL32MA-E PAR-WSC009FA-E PAR-SL100A-E
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
· ·····
·
·
·
· ·····
·
·
·
· ·····
·
·
·
· ·····
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
·
·
·
·
· ·····
·
·
·
· ·····
·
·
·
·
·
·
·
·
Wall Mount PKA
Ceiling-suspended PCA
PKA-A12HA7 PKA-A18HA7 PKA-A24KA7 PKA-A30KA7 PKA-A36KA7 PCA-A24KA7 PCA-A30KA7 PCA-A36KA7 PCA-A42KA7
3-Pin Connector
BACnet® and Modbus Interface
CN24 Relay Kit
IT Extender
Control Interface
kumo station® for kumo cloud® Lockdown bracket for remote controller
Remote Operation Adapter
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Flush Mount Temperature Sensor
Remote Sensor
Remote Temperature Sensor surface mount
Wireless temperature and humitity sensor for kumo cloud®
Deluxe Wired MA Remote Controller
Wired Remote Controller Simple MA Remote Controller
Touch MA Controller
kumo touchTM RedLINKTM Wireless Controller
Wireless MA Receiver
Wireless Remote Controller Wireless MA Remote Controller
Wireless Receiver Kit
Wireless Receiver Kit with i-See sensorTM
PAC-715AD PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB PAC-SF40RM-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN001-FM-1 PAC-SE41TS-E PAC-USWHS003-TH-1 AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2 PAR-SR32MA-E PAR-FL32MA-E PAR-SL93B-E PAR-SA92MW-E
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
152 Appendix
Four-way Cassette PLA
Residential Multi-position AHU PVA
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7 PVA-A12AA7 PVA-A18AA7 PVA-A24AA7 PVA-A30AA7 PVA-A42AA7
3-Pin Connector
BACnet® and Modbus Interface
CN24 Relay Kit
Connector cable for remote display
IT Extender
Control Interface kumo station® for kumo cloud®
Lockdown bracket for remote controller
Remote Operation Adapter
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Flush Mount Temperature Sensor
Remote Sensor
Remote Temperature Sensor surface mount
Wireless temperature and humitity sensor for kumo cloud®
Airzone ZBS Wired Blueface Principal Controller White
Airzone ZBS Wired Lite Controller White
Airzone ZBS Wired Think Controller White
Airzone ZBS Wireless Lite Controller White Wired Remote Controller
Airzone ZBS Wireless Think Controller White
Deluxe Wired MA Remote Controller
Simple MA Remote Controller
Touch MA Controller
kumo touchTM RedLINKTM Wireless Controller
Wireless MA Receiver
Wireless Remote Controller Wireless MA Remote Controller
Wireless Remote Contoller
Wireless Signal Receiver Panel
PAC-715AD PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-SA88HA-EP PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB PAC-SF40RM-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN001-FM-1 PAC-SE41TS-E PAC-USWHS003-TH-1 AZZBSBLUEFACECB AZZBSLITECB AZZBSTHINKCB AZZBSLITERB AZZBSTHINKRB AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2 PAR-SR32MA-E PAR-FL32MA-E PAR-SL100A-E PAR-SR4LU-E
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Ducted PEAD
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 PEAD-A42AA7
3-Pin Connector
BACnet® and Modbus Interface
CN24 Relay Kit
Connector cable for remote display
IT Extender
Control Interface kumo station® for kumo cloud®
Lockdown bracket for remote controller
Remote Operation Adapter
Thermostat Interface
USNAP Adapter
Wireless Interface for kumo cloud®
Flush Mount Temperature Sensor
Remote Sensor
Remote Temperature Sensor surface mount
Wireless temperature and humitity sensor for kumo cloud®
Airzone ZBS Wired Blueface Principal Controller White
Airzone ZBS Wired Lite Controller White
Airzone ZBS Wired Think Controller White
Airzone ZBS Wireless Lite Controller White Wired Remote Controller
Airzone ZBS Wireless Think Controller White
Deluxe Wired MA Remote Controller
Simple MA Remote Controller
Touch MA Controller
kumo touchTM RedLINKTM Wireless Controller
Wireless Remote Controller Wireless MA Receiver
Wireless MA Remote Controller
PAC-715AD PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 PAC-SA88HA-EP PAC-WHS01IE-E TAC-WHS01HC-E RCMKP1CB PAC-SF40RM-E PAC-US444CN-1 PAC-WHS01UP-E PAC-USWHS002-WF-2 PAC-USSEN001-FM-1 PAC-SE41TS-E PAC-USWHS003-TH-1 AZZBSBLUEFACECB AZZBSLITECB AZZBSTHINKCB AZZBSLITERB AZZBSTHINKRB AAR-40MAAU PAC-YT53CRAU-J PAR-CT01MAU-SB MHK2 PAR-SR32MA-E PAR-FL32MA-E
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Appendix 153
Additional Nv-Series Information
Port Adapters Parts Numbers
Model Name MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E PAC-SG76RJ-E
ADP5834 PAC-493PI
Diameter A 3/8" 1/2" 1/2" 3/8" 5/8" 1/4"
Diameter B 1/2" 3/8" 5/8" 5/8" 3/4" 3/8"
Multi-zone Efficiency Ratings
Model NAXMMX20A122A* NAXMMX24A132A* NAXMMX30A132A* NAXMMX36A142A* NAXMMX42A152A* NAXMMX48A182A* NAXMMX60A182A* NAXMPH20A122A* NAXMPH24A132A* NAXMPH30A132A* NAXMPH36A142A* NAXMPH42A152A* NAXMMX48A182A*
Configuration Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted Ducted Mixed
Non-Ducted
SEER 16.00 18.00 20.00 16.00 18.00 20.00 16.20 17.60 19.00 16.00 17.60 19.20 15.20 17.45 19.70 16.00 18.00 20.00 17.00 18.20 19.50 15.00 16.00 17.00 15.50 17.25 19.00 16.00 17.00 18.00 17.50 18.70 20.00 17.00 18.50 20.00 16.00 18.00 20.00
154 Appendix
EER 10.00 11.35 12.70 11.20 12.40 13.60 9.60 10.10 10.60 8.70 9.05 9.40 9.00 9.10 9.20 10.00 11.10 12.20 10.00 11.20 12.50 11.00 12.25 13.50 10.00 11.75 13.50 10.30 11.40 12.50 12.50 13.20 14.00 10.80 12.20 13.40 10.00 11.10 12.20
Diameter A = Female
HSPF 9.30 9.65 10.00 9.20 9.50 9.80 9.60 10.10 10.60 9.80 10.40 11.00 9.10 9.70 10.30 10.10 10.80 11.50 10.70 10.70 10.70 9.50 9.65 9.80 9.00 9.50 10.00 9.80 10.40 11.00 11.00 11.10 11.30 10.60 10.80 11.00 10.10 10.80 11.50
Diameter B = Male
Nv-Series Air Outlet Coverage Range*
Model NAXWPH06B112A*, NAXWPH09B112A*
NAXWPH12B112A* NAXWPH15B112A* NAXWPH18B112A* NAXWST06/09/12A112A*, NAYWST06/09/12A112A* NAXWST15A112A*, NAYWST15A112A* NAXWST18A112A*, NAYWST18A112A* NAXWST24A112A*, NAYWST24A112A* NAXWST30/36A112A*, NAYWST30/36A112A* NAXFKS09A112A*, NAXFKS12A112A* NAXFKS15A112A* NAXFKS18A112A* NAXCKS09A112A* NAXCKS12A112A* NAXCKS15A112A* NAXCKS18A112A* MSZ-EF09NA(B/S/W) MSZ-EF12NA(B/S/W) MSZ-EF15NA(B/S/W) MSZ-EF18NA(B/S/W) NAXWMT09A112A*, NAXWMT12A112A* NAXWMT15A112A* NAXWMT18A112A* NAXWMT24A112A* NAXWMT09A111A* NAXWMT12A111A* NAXWEL09A112A* NAXWEL12A112A* NAXWEL18A112A* NAXWEL24A112A* NAXUKS09A112A* NAXUKS12A112A* NAXUKS18A112A*
Mode HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL HEAT COOL
Function DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET DRY WET
Airflow (CFM) 437 328 454 364 514 376 514 376 406 286 463 385 646 581 738 661 848 763 417 354 470 366 470 417 300 270 336 302 405 365 475 429 420 319 448 319 448 313 466 334 406 286 463 385 625 562 702 632 406 364 406 364 406 286 406 286 625 562 702 632 311 325 332 350 403 417
Coverage (FT) 29.8 22.5 31.0 24.8 34.9 25.6 34.9 25.6 29.5 21.0 33.5 28.0 44.0 39.7 36.9 33.2 45.0 40.7 29.6 25.3 33.3 26.2 33.3 29.7 15.1 13.7 16.9 15.2 20.3 18.3 23.7 21.4 29.2 22.3 31.1 22.3 31.1 21.9 32.3 23.4 29.5 21.0 33.5 28.0 42.6 38.4 47.7 43.1 29.5 26.5 29.5 26.5 29.5 21.0 29.5 21.0 42.6 38.4 47.7 43.1 20.7 21.7 22.1 23.3 26.7 27.6
Appendix 155
Maximum Heating Capacity (Nv-Series)
Indoor Unit
NAXWPH06B112AA NAXWPH09B112AA NAXWPH12B112AA NAXWPH15B112AA NAXWPH18B112AA NAXWPH06B112AA NAXWPH09B112AA NAXWPH12B112AA NAXWPH15B112AA NAXWPH18B112AA NAXWST09A112AA NAXWST12A112AA NAXWST15A112AA NAXWST18A112AA NAXWST24A112AA NAXWST30A112AA NAXWST36A112AA NAXWMT09A112AA NAXWMT12A112AA NAXWMT15A112AA NAXWMT18A112AA NAXWMT24A112AA NAXWMT09A111AA NAXWMT12A111AA NAXWEL09A112AA NAXWEL12A112AA NAXWEL18A112AA NAXWEL24A112AA NAXFKS09A112AA NAXFKS12A112AA NAXFKS15A112AA NAXFKS18A112AA NAXUKS09A112AA NAXUKS12A112AA NAXUKS18A112AA
Outdoor Unit
NAXSPH06B112AA NAXSPH09B112AA NAXSPH12B112AA NAXSPH15B112AA NAXSPH18B112AA NAXSPB06B112AA NAXSPB09B112AA NAXSPB12B112AA NAXSPB15B112AA NAXSPB18B112AA NAXSST09A112AB NAXSST12A112AB NAXSST15A112AB NAXSST18A112AA NAXSST24A112AA NAXSST30A112AA NAXSST36A112AA NAXSMT09A112AB NAXSMT12A112AB NAXSMT15A112AB NAXSMT18A112AB NAXSMT24A112AA NAXSMT09A111AA NAXSMT12A111AA NAXSEL09A112AB NAXSEL12A112AB NAXSEL18A112AB NAXSEL24A112AA NAXSPF09A112AA NAXSPF12A112AA NAXSPF15A112AA NAXSPF18A112AA NAXSKS09A112AA NAXSKS12A112AA NAXSKS18A112AA
50º F 14,445 18,554 21,714 24,544 30,619 14,445 18,554 21,714 24,544 30,619 10,900 14,400 18,000 21,600 27,600 32,600 35,200 10,900 12,200 18,000 18,000 26,000 10,900 12,200 10,900 12,200 18,000 26,000 11,000 13,000 18,000 21,000 12,000 15,400 20,000
41º F 13,703 17,631 20,524 23,637 29,587 13,703 17,631 20,524 23,637 29,587 10,900 14,400 17,100 21,600 27,600 28,030 29,560 10,570 12,200 15,300 18,000 24,440 10,570 12,200 10,570 12,200 18,000 24,440 11,000 13,000 18,000 21,000 10,620 13,630 17,700
32º F 12,962 16,707 19,333 22,730 28,556 12,962 16,707 19,333 22,730 28,556 10,900 14,110 16,920 21,600 27,600 25,420 27,450 9,480 11,220 14,940 18,000 22,360 9,480 11,220 9,480 11,220 18,000 22,360 11,000 13,000 18,000 21,000 9,230 11,850 15,390
Outdoor Temperature Degrees
23º F
14º F
5º F
12,149
11,037
9,924
15,068
13,304
11,540
18,143
16,464
14,482
21,823
19,988
18,089
27,524
25,129
22,211
12,149
11,037
9,924
15,068
13,304
11,540
18,143
16,464
14,482
21,823
19,988
18,089
27,524
25,129
22,211
10,460
9,480
8,170
12,960
11,660
9,790
16,920
16,200
13,680
19,440
17,060
14,900
26,220
23,460
19,320
22,820
19,880
--
25,340
22,880
--
8,500
7,300
5,990
10,120
9,020
7,440
14,400
13,680
12,240
16,560
14,580
12,780
20,020
17,680
15,600
8,500
7,300
5,990
10,120
9,020
7,440
8,500
7,300
5,990
10,120
9,020
7,440
16,560
14,580
12,780
20,020
17,680
15,600
11,000
11,000
11,000
13,000
13,000
13,000
18,000
18,000
18,000
21,000
21,000
21,000
7,840
6,450
5,090
10,060
8,280
6,540
13,060
10,760
8,490
-4º F -- -- -- -- -- -- -- -- -- -- 6,860 7,920 11,160 12,520 15,450 -- -- 4,680 5,850 10,620 10,980 13,260 4,680 5,850 -- -- -- -- 9,130 10,790 14,940 18,480 3,770 4,840 6,290
-5º F 8,700 9,600 12,301 16,001 19,001 8,700 9,600 12,301 16,001 19,001
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
-13º F 7,721 8,048 10,556 14,330 16,433 7,721 8,048 10,556 14,330 16,433
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7,260 8,450 13,860 15,960 -- -- --
156 Appendix
Indoor Unit
NAXUKS09A112AA NAXUKS12A112AA NAXUKS18A112AA NAXCKS09A112AA NAXCKS12A112AA NAXCKS15A112AA NAXCKS18A112AA NAXCKS09A112AA NAXCKS12A112AA NAXCKS15A112AA NAXCKS18A112AA NAXDKS09A112AA NAXDKS12A112AA NAXDKS15A112AA NAXDKS18A112AA NAXDKS09A112AA NAXDKS12A112AA NAXDKS15A112AA NAXDKS18A112AA PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 NAXAMT12A112AA NAXAMT18A112AA
Outdoor Unit
NAXSKH09A112AA NAXSKH12A112AA NAXSKH18A112AA NAXSKS09A112AA NAXSKS12A112AA NAXSKS15A112AA NAXSKS18A112AA NAXSKH09A112AA NAXSKH12A112AA NAXSKH15A112AA NAXSKH18A112AA NAXSKS09A112AA NAXSKS12A112AA NAXSKS15A112AA NAXSKS18A112AA NAXSKH09A112AA NAXSKH12A112AA NAXSKH15A112AA NAXSKH18A112AA NAXSKS09A112AA NAXSKS12A112AA NAXSKS15A112AA NAXSKS18A112AA NAXSKS24A112AA NAXSKS30A112AA NAXSKS36A112AA NAXSKH09A112AA NAXSKH12A112AA NAXSKH15A112AA NAXSKH18A112AA NAXSKH24A112AA NAXSKH30A112AA NAXSKH36A112AA NAXSKS12A112AA NAXSKS18A112AA
50º F 12,000 15,000 18,600 11,000 13,000 18,000 19,700 11,000 13,800 16,400 18,800 12,000 15,000 18,000 21,600 12,500 15,000 15,000 21,600 12,000 15,000 18,000 21,600 25,000 30,000 33,500 12,000 15,000 18,000 21,600 25,000 32,000 37,000 15,000 21,600
41º F 12,000 15,000 18,600 9,730 11,510 15,930 17,440 11,000 13,800 16,400 18,800 10,620 13,280 15,930 19,120 12,500 15,000 15,000 21,600 10,620 13,280 15,930 19,120 22,130 26,560 29,660 12,000 15,000 18,000 21,600 25,000 32,000 37,000 13,280 19,120
32º F 12,000 15,000 18,600 8,460 10,000 13,850 15,150 11,000 13,800 16,400 18,800 9,230 11,540 13,850 16,620 12,500 15,000 15,000 21,600 9,230 11,540 13,850 16,620 19,230 23,080 25,770 12,000 15,000 18,000 21,600 25,000 32,000 37,000 11,540 16,620
Outdoor Temperature Degrees
23º F
14º F
5º F
12,000
12,000
12,000
15,000
15,000
15,000
18,600
18,600
18,600
7,180
5,920
4,670
8,490
6,990
5,520
11,760
9,680
7,640
12,870
10,600
8,370
11,000
11,000
11,000
13,800
13,800
13,800
16,400
16,400
16,400
18,800
18,800
18,800
7,840
6,450
5,090
9,800
8,070
6,370
11,760
9,680
7,640
14,110
11,620
9,170
12,500
12,500
12,500
15,000
15,000
15,000
15,000
15,000
15,000
21,600
21,600
21,600
7,840
6,450
5,090
9,800
8,070
6,370
11,760
9,680
7,640
14,110
11,620
9,170
16,330
13,450
--
19,600
16,140
--
21,890
18,030
--
12,000
12,000
12,000
15,000
15,000
15,000
18,000
18,000
18,000
21,600
21,600
21,600
25,000
25,000
25,000
32,000
32,000
32,000
37,000
37,000
37,000
9,800
8,070
6,370
14,110
11,620
9,170
-4º F 8,640 10,800 13,392 3,460 4,080 5,660 6,190 7,920 9,936 11,808 13,536 3,770 4,710 5,660 6,790 9,000 10,800 10,800 15,552 3,770 4,710 5,660 6,790 -- -- -- 8,640 10,800 12,960 15,552 -- -- -- 4,710 6,790
-5º F -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 22,250 28,480 32,930 -- --
-13º F 5,160 6,450 7,998
-- -- -- -- 4,730 5,934 7,052 8,084 -- -- -- -- 5,375 6,450 6,450 9,288 -- -- -- -- -- -- -- 5,160 6,450 7,740 9,288 20,000 25,600 29,600 -- --
Appendix 157
Maximum Heating Capacity (Nv-Series)
Indoor Unit NAXAMT24A112AA NAXAMT30A112AA NAXAMT36A112AA NAXAMT12A112AA NAXAMT18A112AA NAXAMT24A112AA NAXAMT30A112AA NAXAMT36A112AA
Outdoor Unit NAXSKS24A112AA NAXSKS30A112AA NAXSKS36A112AA NAXSKH12A112AA NAXSKH18A112AA NAXSKH24A112AA NAXSKH30A112AA NAXSKH36A112AA
50º F 25,000 30,000 33,500 15,000 21,600 23,000 32,000 37,000
41º F 22,130 26,560 29,660 15,000 21,600 23,000 32,000 37,000
32º F 19,230 23,080 25,770 15,000 21,600 23,000 32,000 37,000
Outdoor Temperature Degrees
23º F
14º F
5º F
16,330
13,450
--
19,600
16,140
--
21,890
18,030
--
15,000
15,000
15,000
21,600
21,600
21,600
23,000
23,000
23,000
32,000
32,000
32,000
37,000
37,000
37,000
-4º F -- -- -- 10,800 15,552 -- -- --
-5º F -- -- -- -- -- 20,470 28,480 32,930
-13º F -- -- --
6,450 9,288 18,400 25,600 29,600
Maximum Heating Capacity (MX)
Indoor Unit
NAXMMX20A122A* NAXMMX24A132A* NAXMMX30A132A* NAXMMX36A142A* NAXMMX42A152A* NAXMMX48A182B* NAXMMX60A182B* NAXMPH20A122A* NAXMPH24A132A* NAXMPH30A132A* NAXMPH36A142B* NAXMPH42A152B* NAXMPH48A182B*
50º F 22,000 25,000 28,600 36,000 45,000 48,000 60,000 22,000 25,000 28,600 36,000 42,000 48,000
41º F 22,000 25,000 28,600 36,000 45,000 48,000 60,000 22,000 25,000 28,600 36,000 42,000 48,000
32º F 18,920 24,000 28,020 33,480 41,850 48,000 60,000 22,000 25,000 28,600 36,000 42,000 48,000
Outdoor Temperature Degrees
23º F
14º F
15,840
12,980
20,750
17,250
24,310
20,300
29,160
24,120
36,450
30,150
39,840
32,160
51,000
40,800
22,000
22,000
25,000
25,000
28,600
28,600
36,000
36,000
42,000
42,000
48,000
48,000
5º F 9,900 13,250 15,730 18,720 23,400 28,800 36,000 22,000 25,000 28,600 36,000 42,000 48,000
-4º F -- -- -- -- -- 25,440 31,200 21,120 23,750 26,880 30,960 36,120 41,280
-13º F -- -- -- -- -- -- --
20,460 22,500 25,160 26,640 31,080 35,520
158 Appendix
Additional P-Series Information
Outlet Air Speed and Coverage Range*
Model
Airflow (CFM)
Air Speed (ft/sec)
Coverage Range (ft)
PCA-A24KA7
670
10.2
32
PCA-A30KA7
705
10.5
33
PCA-A36KA7
990
11.8
41
PCA-A42KA7
1,025
12.1
42
PKA-A12HA7
425
20.0
35
PKA-A18HA7
425
20.0
35
PKA-A24KA7
775
19.7
47
PKA-A30KA7
775
19.7
47
PKA-A36KA7
920
22.3
53
PLA-A12EA7
530
7.8
13
PLA-A18EA7
600
8.8
14
PLA-A24EA7
810
11.9
19
PLA-A30EA7
880
12.9
21
PLA-A36EA7
1,200
17.6
28
PLA-A42EA7
1,200
17.6
28
*Air coverage represents the distance with 0.8 ft/sec air speed when blowing out horizontally from the unit operating at the high fan speed. This is a general guideline; actual coverage depends on size and layout of the room.
Appendix 159
Correction Factors
160 SAppepceifnicdaixtions
Length (ft)
Appendix 161
Correction Factors
Cooling Piping Correction Factors: PUZ
Length (ft)
162 Appendix
Cooling Correction Factors: PUZ-HA Heating Correction Factors: PUZ-HA
Appendix 163
External Dimensions: Nv-Series
NAXWPH06B112AA, NAXWPH12B112AA, NAXWPH18B112AA,
INDOOR UNIT
NAXWPH09B112AA, NAXWPH15B112AA, NAXWPH18B112AA
MSZ-EF09NA(W)(B)(S) MSZ-EF12NA(W)(B)(S) MSZ-EF15NA(W)(B)(S) MSZ-EF18NA(W)(B)(S)
INDOOR UNIT
Unit : inch
12
NAXWST06A112AA NA(X/Y)WST09A112A* NA(X/Y)WST12A112A* NA(X/Y)WST15A112A*
INDOOR UNIT
NAXWST18A112AA NAYWST18A112AA
INDOOR UNIT
36-5/16 35-13/16 1/4
12
2-1/16
27-15/16
6-5/16
2-9/16
2-9/16 3-11/16
3-15/16 1/4
Air in
Installation plate Piping
Air out
2-9/16 4-1/2 5-3/4
2-9/16
Drain hose
2-13/16
2-1/16
2-1/2
164 Appendix
Nv-Series
NA(X/Y)WST24A112A* INDOOR UNIT
NA(X/Y)WST(30/36)A112A* INDOOR UNIT
45-1/2
Unit : inch
14-3/8 2-1/2 2-15/16
2-15/16
46-1/16 33-11/16
11-5/8
Air in
1/4 Installation plate Piping
9-1/2
2-5/8
Air out
5-7/8
Drain hose
NAXWMT09A112A* NAXWMT09A111A* NAXWMT12A112A* NAXWMT12A111A* NAXWMT15A112A*
NAXWEL09A112A* NAXWEL12A112A*
INDOOR UNIT
NAXWMT18A112A* NAXWEL18A112A* NAXWMT24A112A* NAXWEL24A112A*
INDOOR UNIT
36-5/16
35-13/16 1/4
12
2-1/16
27-15/16
6-5/16
2-9/16
2-9/16 3-11/16
3-15/16 1/4
Air in
Installation plate Piping
Air out
2-9/16 4-1/2 5-3/4
2-9/16
Drain hose
2-13/16
2-1/16
2-1/2
Appendix 165
Nv-Series
NAXAMT12A112A* NAXAMT18A112A*
Top view ø26 Knockout Hole
ø26 Knockout Hole for electrical heat wiring
Unit:mm(in.)
Note: Electrical entrance for AMT located on both left and right side of the cabinet. See right or Left side view for knockout locations.
NAXAMT24A112A* NAXAMT30A112A* MVZN-AA1X2AAMA7T3M6VAZ1-1A21A8*AA7
INDOOR UNIT
2-ø4.6 Burring Holes for electric heat installation
1 Refrigerant piping
MVZ-A24AA7flareMcoVnneZct-ioAn(g3as0) AA7 2 Refrigerant piping flare connection(liquid)
Secondary drain pipe
(Emergency ø19.05(3/4)
3d/r4avT"iinFoeiPnpwgT)
Primary drain pipe ø(ø2G16r9aK.0vn5itoy(3cd/4kro)a3iun/t)4H"FoPlTe (In(Hdoorirzo/ nOtuatldleofot)r unit connection)
2-ø4.6 Burring Holes for electric heat installation
MVZ-A36AA7
B(Duct)
C Air outlet
Front Note 1.Keep thevsieewrvice space for maintenance at the front.
ø26 Knockout Hole (Remote controller transmission)
Top
Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT
13.2(9/16) 24(15/16)
1 Refrigerant piping flare connection(gas)
2 Refrigerant piping ø26 Knockout Hole flare connection(liquid)
(Indoor / Outdoor unit connection)
ø26 Knockout7H7o.8le(3-1/8) (Indoor / Outdoor unit connection) (Remote controller6tr6an(2sm-5is/s8io)n)
70(2-13/16)
55(2-3/16)
S(øE1em9co.e0nr5gd(ea3nr/y4cy)d3rS(daE/re4ianm"cinFpoeiPninrpgTgde)eanrycydrdarianinpinipge) Primary draøin1p9i.p0e5(3/4) 3/4"FPT (Gravity drain) ø19.05(3/4) 3/4"FPT (Horizontal left)
B(Duct) C
Air outlet
8(3/8)
28.8(1-3/16) 76(3)
Secondary drain pipe (TReermmointeal(øcEbo1lnmo9tcr.eo0krl5lge(er3nt/r4ca)yn3sdm/r4ai"siFsniPionnTg)) Terminal(Hbloorcikzontal Right) (Indoor / Outdoor unit connection) Control bPorximary drain pipe P43ri(m1-a3r/y4(ø)dG1rar9ai.nv0i5pty(ip3de/4ra)in3)/4"FPT (Gravity dCraoinnt)rol box ø19.05(3(/R4)e3m/4o"vFePBTlower Panel)
55(2-3/16)
Fvrieownt
117.4 (4-5/8)
548(21-5/8)
402(15-7/8) (Duct)
Top ø26 Knockout Hole
(øRt2rea6mn(RKs(oenmIctnmeooidoscncotskenooiooencrunoct/trn)toiOHtorlolonuelll)teredrotroarnsumniistsion)
Bottom
Unit : inch/cm
525.5(20-3/4) 8(3/8) F E
Left side view
Unit:mm(in.) Model
Nominal Filter Size
43(1-3/4) 92(3-5/8)
G
Secondary drain pipe
H
(Emergency draining)
ø19.05(3/4) 3/4"FPT
Duct Connection
55B(2vo-i3tet/o1w6m)
8(3/8) 30(1-3/16)
Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT (Horizontal Right)
Primary drain pipe (Gravity drain) D ø19.05(3/4) 3/4"FPT
Right side view
12
18 24
508 x 406.4 x 25.4
376 x 402
(2L0evftxiesw1id6e x 1)
(14-13/16 x 15-7/8)
Air inlet A
3 Air filter
30 36
508 x 508 x 25.4
477 x 402
(20 x 20 x 1)
(18-13/16 x 15-7/8)
Bottom view
50.8(2)
Bottom
Right side view
470(18-9/16)
Model 12 18 24 30 36
A
B
C
D
E
432
376
281
224
1,010.8
(17M)odel (14-A13/16)B (11C-1/8)D (8E-7/8) F (3G9-13/1H6)
MVZ-A12AA7
MM5VV3ZZ4--AA1284AAAA77
432 376 281 224 1275 680 823 735.5
(4177)7(14-13/16) (1318-1/28).6(8-7/8) (502-16/46) .(526-13/16) (32-17/,116)13.(829)
M(2VZ1-A) 30AA(7185-3143/164)77 (13852-.16 /82)66.5 (113078-1/27)37 95(34.35 -7/879)2
MVZ-A36AA7 (21) (18-13/16) (15-1/8) (10-1/2) (54-1/4) (29-1/16) (37-9/16) (31-3/16)
F
G
H
J
Gas Pipe Liquid pipe
Model
3 Nominal Filter Size Duct Connection
J 680 36.8(1-1/82)23 (2J6-13/11G6a)s pipe(322 -L7iq/u1id6p)ipe
735.5 (29)
MMMVVVZZZ---AAA112(1284AAA43AAA-637770/165)08(X204X0ø61ø.64X91X1.225)5.27.4
(3/8)
ø 6.35
(1/(124)-1337/61X6X40125(-17//48))
360
(14-3/167) 37
ø12.7 (1/2)
ø6.35 (1/4)
953.5
(184(-623/1196-) 1/1ø61(5)5/.88)8 (37-9ø(9/31./5862) )
792
MVZ-A30AA7
MVZ-A36A4A671
50(82X05X0280XXø215)1.45.88(18-1437/71X6X401ø25-97/.85)2
(5/8)
(3/8)
(31-3/16) (18-3/16)
NAXUKS09A112AA, NAXUKS12A112AA, NAXUKS18A112AA INDOOR UNIT
13 2
MFZ-KJ09N INDOOR
MUZ-FH15N MUZ-FH18N MUZ-GL18N MUZ-GL24N MUZ-HM24 MUFZ-KJ15 OUTDOOR
16-7 Air in
6-7/8
34-5/8
17-25/32
166 Appendix
Nv-Series
NAXFKS09A112A* NAXFKS12A112A* NAXFKS15A112A* NAXFKS18A112A*
INDOOR UNIT
NAXSPH06B112A* NAXSPB06B112A* NAXSPH09B112A* NAXSPB09B112A* NAXSPH12B112A* NAXSPB12B112A*
NAXSST09A112A* NAXSST12A112A* NAXSST15A112A* NAYSST(09/12/15)A112A * NAYSST(12/15)A112A*
Unit : inch
NAXSMT09A111A* NAXSMT12A111A* NAXSEL09A112A* NAXSEL12A112A* NAXSEL18A112A*
NAXSMT09A112A* NAXSMT12A112A* NAXSMT15A112A* NAXSMT18A112A* OUTDOOR UNIT
NAXSPF09A112A* NAXSPF12A112A*
REQUIRED SPACE
*1 4 in. (100 mm) or more when front and sides of the unit are clear
4
in. or
(m1o0r0emm)
clear *1
4 in. o(1r0m0omrem)
(MUZ-FH06/09/12NA) (MUZ-FH06/09/12NAH)
2 x hole 3/8 x 13/16
8 ino.r(m20o0rem*m2 )
14
in. or
m(3o5r0e
mm)
*2 When any 2 sides of left, right and rear of the unit are clear
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8
NAXSP(H/B)(15/18)B112A* NAXSST18A112AA NAXSMT24A112AA NAXSPF15A112AA
NAXSPB18A112AA NAXSEL24A112AA NAXSST18A112AA NAXSPF18A112AA
OUTDOOR UNIT
13 2
16-7/16 Air in
Air in
6-7/8
Air out 19-11/16
33-1/16 4-5/16
14-3/16 Clear *1
REQUIRED SPACE
*1 20 in. (500 mm) or more when front and sides of the unit are clear
Drain hole 1-5/8 1-9/16
4 or
mino. r(e100
mm)
4 oinr.m(1o0r0e mm)
2 x hole 13/32 x 13/16 3-3/16
20orinm. (o5r0e0*2mm)
o1r 4mino.re(350 mm)
*2 When any 2 sides of left, right and rear of the unit are clear
Service panel
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4
34-5/8
17-25/32
35 44
6-1/2 3-29/32
7-11/16
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2
NA(X/Y)WST(30/36)A112A*
OUTDOOR UNIT
REQUIRED SPACE
4 in. or more
Open as a rule 20 inch or more if the back, both sides and top are open
Open as a rule 20 inch or more if the front and both sides are open
4 inch or more / 8 inch or more if there are obstacles to both sides
14 in. or more
Appendix 167
Nv-Series
NAXCKS09A112AA, NAXCKS12A112AA, NAXCKS15A112AA, NAXCKS18A112AA INDOOR UNIT
Unit : inch/cm
19/32~1-15/32(15~37) 19/32~1-15/32(15~37)
4-21/32(118)
13-3/16(335) 22-7/16(570)
22-11/16~24-13/32(576~620) Ceiling hole 16-17/32(420)
Suspension bolt pitch
Fresh air intake
20-7/8(530) Suspension bolt pitch
Detail drawing of fresh air intake
3-15/16( 100)
3- 1/8( 2.8) Burring hole
1(25)
2-7/8( 73.4) Cut out hole
120
22-7/16(570)
120
1-7/32(31) 3-7/16(87)
Ceiling surface
2-1/4(57) 2-7/32(56)
7-27/32(199) 13-27/32(352)
13-3/16(335)
) 7 322~-11/156~214-1( 3/232(5376/~6520)1 Ce- ilin1g h~ole 2 3 / 9 1
)7 3 ~ 5 1(2 3/5 1-1 ~ 2 3/9 1
Refrigerant 21/32(17) pipe (gas) Refrigerant pipe (liquid)
7-15/16(202)
9-1/16(230)
Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M10 or W3/8
Wiring entry
7-5/32(182)
7-19/32(193) 8-3/16(208) 9-1/4(235)
1-7/8(48)
Terminal block
Grille
Ceiling surface
25-19/32(650) 11-27/32(301) Air outlet hole
2-5/32(55) 1-3/8(35)
25-19/32(650)
11-27/32(301) Air outlet hole
Brand label
V/M V/M
Grille Drain hole
Auto vane
14-27/32(377) Air intake hole
V/M V/M
1-3/8(35)
14-27/32(377) Air intake hole
2-5/32(55)
Air intake grille Vane motor
Models 09 12 15
Refrigerent pipe (liquid)
1/4 inch ( 6.35mm) flared connection
1/4 inch ( 6.35mm) flared connection
1/4 inch ( 6.35mm) flared connection
Refrigerent pipe (gas)
3/8 inch ( 9.52mm) flared connection
3/8 inch ( 9.52mm) flared connection
1/2 inch ( 12.7mm) flared connection
2-19/32(66)
25/32(20)
(27+05)
4-3/4(121) 3-21/32(93) 1-1/2~2-9/32(38~58) Suspension bolt lower edge
+3/16 0
1-1/16
NAXDKS09A112AA, NAXDKS12A112AA, NAXDKS15A112AA, NAXDKS18A112AA INDOOR UNIT
159(6-9/32)
345(13-19/32)
15(19/32) 2XE-ø2.9(1/8)
Drain pipe(O.D.ø32(1-1/4)) (Emergency draining)
Suspension bolt hole 4-14X30(9/16X1-3/16) Slot
20(13/16) 12(1/2)
L-ø2.9(1/8)
37(1-15/32) 100(3-15/16) 157.5 (6-7/32) 37(1-15/32)
88(3-15/32)
100(3-15/16)XJ=K 100(3-15/16)
H
A N B (Suspension bolt pitch)
C M
D (Duct) 100(3-15/16)X(E-1)=F 100(3-15/16)
Air
Air
outlet
inlet
88(3-15/32)
57(2-1/4)
25(1)
20(13/16) 12(1/2)
20(13/16) 30(1-3/16) 57(2-1/4)
49 (1-15/16)
10(13/32)
625(Suspension bolt pitch) (24-5/8)
Drain pipe(O.D.ø32(1-1/4))
23(29/32) 10(13/32)
700(27-9/16) 677(26-21/32)
Control box
102(4-1/32) 170(6-23/32) 200(7-7/8)
90 (3-9/16)
23(29/32)
Air filter
Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line)
Knockout hole ø27(1-3/32) (Remote controller transmission line)
23(29/32) 25(1)
150(Duct) (5-29/32) 100 (3-15/16)
2X2-ø2.9(1/8)
116
70
(4-19/32)
(2-25/32)
270(10-21/32)
1 Refrigerant piping
2 Refrigerant piping
flare connection (gas) flare connection (liquid)
Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Drain pipe(O.D.ø32(1-1/4)) (Spontaneous draining)
50(1-31/32) Note2
G50(1-31/32)
(73707-19/3A2)ccess
175±5(6-29/32±7/32) door (Actual length)
(1-31/32 5~05~-2195/302)
(17-2435/302) (17M4-25o30r/e32th)a(1n13-1030/16)
Required space for service and maintenance
Less than 300 (11-13/16)
Drain hose (I.D.ø32(1-1/4)) <accessory>
Less than 550 (21-21/32)
More than 10 (13/32)
More than 20 (13/16)
Ceiling surface Access door Make the access door at the appointed position properly for service maintenance.
mm(in.)
Model 09 12 15
18
A BCD 700 752 798 660 (27-9/16) (29-5/8) (31-7/16) (26) 900 952 998 860 (35-7/16) (37-1/2) (39-5/16) (33-7/8) 1100 1152 1198 1060 (43-5/16) (45-3/8) (47-3/16) (41-3/4)
E F GH
7
600 800 660 (23-5/8) (31-1/2) (26)
9
800 1000 860 (31-1/2) (39-3/8) (33-7/8)
11
1000 1200 1060 (39-3/8) (47-1/4) (41-3/4)
J K L M N 1 Gas pipe
5
500 (19-11/16)
16
839 790 (33-1/16) (31-1/8)
ø9.52(3/8)
7
700 (27-9/16)
20
1039 990 (40-29/32) (39)
9
900 (35-7/16)
24
1239 1190 (48-25/32) (46-7/8)
ø12.7(1/2)
2 Liquid pipe ø6.35(1/4)
Note1.Use M10 screw for the suspension bolt (field supply).
1. Us2e.KMe1e0pstchrewseforvritcheesspuascpeenfosirotnhebomlta(fiinetlednsaunpcpelya).t the bottom.
2. 3.
4.
TKINnheA34ciesa..XpTISStcsnhDhtEEheehKciaZZseaauSr--ntcssnKK1iheenii8DDntard)Aalv,01ericin1tt98ctha1ied,Nnite21neudsAAn2lscepi4NcttmiafnaoiAdmscsotreeu4tudoNascsfedmlotAlelfesroioXtdslhtrshd,DhreuaSeeehKsvlmfEaseiSmelvZtod1hea4e-v,5ariKrenfAe4v(aDtfmete1nihfe11anseo2l52an.dvANanfseasic.AArnuetf4hsmpilae.tpmeotlradytoh()ierdsela,uefwibtpllt,ohsepwtuilrctyhoch(imtwscihouhi.tanphhspsta3lhiysdefewa3u.ninftsahi.tn)N,stA.hXenDKinSst(a0l9l /t1h2e)A112A
models
have
2
fans.
filter (field supply) at suction side.
168 Appendix
Nv-Series
4 OUTLINES AND DIMENSIONS
NAXSKS09A112A*
NAXSKS12A112A*
OUTDOOR UNIT
SUZ-KA09NA(H)2.MNXAXSSUKZS-K1A5A121N1A2A(H*)2.MX SUZ-KA15NA(H)2.MX
4 NAOXUSKTSL18INA1E1S2A*ANNDAXDSIKMH0E9NA1S1I2OA*NS
Unit : inch
UnitS: iUncZh-(mKmANN)1AA8XXNSSAKK(HSS)23240.TAAH111122SAAU**Z-KANN2AA4XXNSSAKK(HHH)112.52TAAH1111S22AAUZ** -KA30NOA(UHT)2D.TOHORSUUZN-KITA36NA(H)2.TH
NAXSKS36A112A* NAXSKH18A112A*
Unit: inch
REQUIRED SPACE
*1 4 in. (100 mm) or more when front and sides of the unit are clear
4
in. or
(m1o0r0emm)
4 in. o(1r0m0omrem)
(KA09/12/15NA) (KA09/12/15NAH)
holes
8 ino.r(m20o0rem*m2)
14
in. or
m(3o5r0e
mm)
*2 When any 2 sides of left, right and rear of the unit are clear
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (09/12)
Ø 1/2 (15)
clear *1 13
2
34-5/8
16-7/16 Air in
Air in
6-7/8
Air out 19-11/16
33-1/16 4-5/16
14-3/16 Clear *1
REQUIRED SPACE
*1 20 in. (500 mm) or more when front and sides of the unit are clear
Drain hole 1-5/8 1-9/16
4 or
mino. r(e100
mm)
4 oinr.m(1o0r0e mm)
2-holes 13/32 13/16 3-3/16
20orinm. (o5r0e0*2mm)
o1r 4mionr.e(350 mm)
*2 When any 2 sides of left, right and rear of the unit are clear
Service panel
Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 (KA18) Refrigerant pipe (flared) Ø 3/8 (KA24/30/36)
17-25/32
35 44
6-1/2 3-29/32
NTAXXSSKKHH2244AA111122AA** OUTDOOR UNIT
Unit: mm<in>
7-11/16
Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2 (KA18) Refrigerant pipe (flared) Ø 5/8 (KA24/30/36)
NATXXSSKKHH3300AA111122AA**,, NNTAXXSSKKHH3366AA111122AA** OUTDOOR UNIT
Unit : inch
Unit: mm<in>
OCH699
4
OCH688
4
* *
*1 *1
Appendix 169
External Dimensions: P-Series
PLA-A12EA7 PLA-A18EA7 PLA-A24EA7 PLA-A30EA7 PLA-A36EA7 PLA-A42EA7
INDOOR UNIT
1-7/16(37)
(89) 3-1/2
OPTIONAL PART:SIGNAL RECEIVER
20(508) (AIR INTAKE HOLE)
PLA-A.EA7*:12/18/24/30/36/42
MODELS
A REFRIGERANT PIPE6.35 REFRIGERANT PIPE12.7 9-1/2 FLARED CONNECTION 1/4F FLARED CONNECTION 1/2F (241)
B 10-3/16 (258)
CD
E
3(76)
3(76.5)
10-7/16(265) OR MORE
F 137-13/16(3500) OR LESS
REFRIGERANT PIPE9.52 REFRIGERANT PIPE15.88 11-1/16 11-3/4 FLARED CONNECTION 3/8F FLARED CONNECTION 5/8F (281) (298)
3-1/8
12(305) 177-3/16(4500)
(79.5)
OR MORE OR LESS
CORNER POCKET VANE MOTOR
AIR INTAKE GRILLE
20(508) (AIR INTAKE HOLE)
37-3/8(950) 20-7/8(530) (AIR OUTLET HOLE)
1-7/16 3-1/2
(89)
GRILLE
CEILING REMOTE CONTROLLER WIRE ENTRY
DRAIN HOLE
(20-45) 13/16 TO 1-3/4 REMOTE CONTROLLER WIRE ENTRY
(37)
(AIR OUTLET HOLE) 20-7/8(530) 37-3/8(950)
COMPANY NAME BRANCH DUCT HOLE
AUTO VANE
I-SEE SENSOR CORNER PANEL
SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER
EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)
(20-45) 13/16 TO 1-3/4
(CEILING HOLE) 33-7/8 TO 35-13/16(860-910)
31-5/16 (795)
(145) 5-11/16
(SUSPENSION BOLT PITCH)
(20-45) 13/16 TO 1-3/4
FRESH AIR INTAKE HOLE
(20) 13/16
(145) 5-11/16
17-11/16(450)
70°
REMOTE
CONTROLLER
TERMINAL BLOCK
33-1/16(840)
BRANCH DUCT HOLE
INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK
(SUSPENSION BOLT PITCH)
(660+040)
26
+1-9/16 0
BRANCH DUCT HOLE
33-7/8 TO 35-13/16(860-910) (CEILING HOLE)
(133) 5-1/4
(20) 13/16
D C
3-1/8(79.5)
(20-45) 13/16 TO 1-3/4
{ 5-7/8({ 150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT)
{ 6-7/8({ 175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT)
(193) 7-5/8
(222) 8-3/4
SUSPENSION BOLT M10 OR W3/8
1 2
(60) 2-3/8
BRANCH DUCT HOLE 33-1/16(840)
MAIN UNIT 24-3/4(628)
1/4(6) 5-11/16(145)
(145) 5-11/16
DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET)
(190) 7-1/2
A B
(170) 6-11/16 (140) 5-1/2
1-9/16 (40)
+3/16 0
11/16
(17+05)
4-1/8 (105)
(50-70) 1-15/16 TO 2-3/4
2-5/16 (58)
THE BOTTOM OF I-SEE SENSOR SUSPENSION BOLT LOWER EDGE
INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY
GRILLE
CEILING
PKA-A24KA7 PKA-A30KA7 PKA-A36KA7 INDOOR UNIT
PKA-A12HA7 PKA-A18HA7 INDOOR UNIT
15-3/16(387)
7-1/2(192)
Top side
Unit : inch/cm
7-3/4(197)
11-5/8(295)
2-1/8 (55)
23-9/16(599)
Front side
Mount board Right side
27-1/16(688) 35-3/8(898)
6-1/16(155)
9-13/16(249)
Knock out hole for right piping
A 3/16(5)
PCA-A24KA7 PCA-A30KA7 INDOOR UNIT
2-9/16(65.2)
5-17/32(140.3)
16-11/16(423.7)
Top side
17(431.7)
Front side
7/16(11)
14-3/8(365)
2-29/32(74)
33-21/32(855) 46-1/16(1170)
9-1/2(241)
1/16(2)
50-3/8(1280) 46-3/16(1173)
1/16(2)
2(51) 3/8(10) 3/16(5)
9/16 14 9-5/16(236)
3-5/16(84) 3-7/16(88) 7-11/16(195)
9-1/16(230)
Right side Mount board
C
11-5/8(295) Operation lamp
3/16(5) Knockout hole for right piping
DEFROST/STAND BY lamp Receiver
Air intake
Air outlet
47-3/16(1198)
7-3/16(182)
3-3/8(85)
10(254) 18-3/4(476) 26-3/4(680)
2-1/4(57)
In case of wireless remote controller and i-see Sensor (Optional Parts)
7-1/16(180) 7-7/8(200) 9-3/16(233) 9-11/16(246)
liquid 3/8(9.52)
gas 5/8(15.88) When drain socket is installed
Drainage
In case of wireless remote controller and i-see Sensor (Optional Parts)
Emergency operation switch <Cooling>
Emergency operation switch <Heating>
i-see Sensor
Receiver DEFROST/STAND BY lamp
Operation lamp
NOTES.
1.Use M10 or W3/8 screw for anchor bolt.
2.Please be sure when installing the drain pump (option parts),
refrigerant pipe will be only upward.
170 Appendix
P-Series
PCA-A36KA7 PCA-A42KA7 INDOOR UNIT
Unit : inch/cm
PEAD-A09AA7 PEAD-A12AA7 PEAD-A15AA7 PEAD-A18AA7 PEAD-A24AA7 PEAD-A30AA7 PEAD-A36AA7 PEAD-A42AA7
INDOOR UNIT
1/16(2)
63(1600) 58-3/4(1493)
Air outlet
59-3/4(1518)
1/16(2)
2(51) 3/8(10) 3/16(5)
9-5/16(236)
3-5/16(84) 3-7/16(88) 7-11/16(195)
9-1/16(230)
9/16 14
7-3/16 182
3-3/8 85
2-1/4 57
In case of wireless remote controller and i-see Sensor (Optional Parts)
7-1/16(180) 7-7/8(200) 9-3/16(233) 9-11/16(246)
liquid 3/8(9.52) gas 5/8(15.88) When drain socket is installed Drainage
In case of wireless remote controller and i-see Sensor (Optional Parts)
Emergency operation switch <Cooling>
Emergency operation switch <Heating>
10(254) 18-3/4(476) 26-3/4(680)
Air intake
Receiver DEFROST/STAND BY lamp Operation lamp
Outlet air side view
40(1-5/8) 200(7-7/8)
Opposite piping side view
Drain pipe(O.D ø32(1-1/4))
(Emergency drain) Bottom
15(5/8)
Top 2XE-ø2.9(1/8)
Top view
378(14-15/16) 120°
(4ø-11255/16)
120° 135 (5-3/8)
153(6-1/16)
Fresh air intake ø100(3-15/16) knock out hole Note 4
3-ø2.9(1/8) mount hole
18(3/4)
Inlet air side view 210(8-5/16)
Air outlet
Air inlet
Air filter
A B(Suspension bolt pitch)
C G
D(Duct) 100(3-15/16)X(E-1)=F 100(3-15/16)
58(2-5/16) J±3(J±1/8)
H±3(H±1/8) 40(1-5/8)
10(7/16)
23(15/16) 21(7/8)
20(13/16) 30(1-3/16)
57(2-1/4)
(Suspension bolt pitch) 643(25-3/8)
Model
A
PEAD-A12,18AA7
900 (35-7/16)
PEAD-A24,30AA7
1100 (43-5/16)
PEAD-A36,42AA7
1400 (55-1/8)
B 954 (37-9/16)
1154 (45-7/16)
1454 (57-1/4)
1000 (39-3/8)
1200 (47-1/4)
1500 (59-1/16)
DE
860 (33-7/8)
9
1060 (41-3/4)
11
1360 (53-9/16)
14
CF 800 (31-1/2)
1000 (39-3/8)
1300 (51-3/16)
Unit:mm(in.)
G 858 (33-13/16)
1058 (41-11/16)
1358 (53-1/2)
H 72 (2-7/8)
78 (3-1/8)
Unit:mm(in.)
Model
J 1 Gas pipe 2 Liquid pipe
PEAD-A12,18AA7
62 (2-1/2)
ø12.7 (1/2)
ø6.35 (1/4)
PEAD-A24,30AA7 66 (2-5/8)
PEAD-A36,42AA7
ø15.88 (5/8)
ø9.52 (3/8)
PVA-A12AA7 PVA-A18AA7 PVA-A24AA7 PVA-A30AA7 PVA-A36AA7 PVA-A42AA7
INDOOR UNIT
70(2-13/16) 55(2-3/16)
G H
2-ø4.6 Burring Holes for electric heat installation 1 Refrigerant piping brazing connection(gas) 2 Refrigerant piping brazing connection(liquid) S(Eemcoenrgdeanrycydrdarianinpinipge) ø19.05(3/4) 3/4"FPT Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT (Horizontal left)
43(1-3/4) 92(3-5/8) Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT 55(2-3/16)
B(Duct) C
Air outlet
8(3/8)
8(3/8) 30(1-3/16)
28.8(1-3/16) 76(3)
(TReremmiontael bcloonctkroller transmission) Terminal block (Indoor / Outdoor unit connection) Control box 43(1-3/4) P(Grirmavairtyy ddrraaiinn)pipe ø19.05(3/4) 3/4"FPT
Secondary drain pipe (Emergency draining) ø19.05(3/4) 3/4"FPT (Horizontal Right) Primary drain pipe (Gravity drain) ø19.05(3/4) 3/4"FPT D
3 Air filter Bvoitetowm
Air inlet A
525.5(20-3/4) 8(3/8) F E
55(2-3/16)
13.2(9/16) 24(15/16)
Fvrieownt Top
117.4 (4-5/8)
ø26 Knockout Hole (Remote controller transmission)
548(21-5/8) 402(15-7/8) (Duct)
Bottom
Right side view
470(18-9/16) 50.8(2)
J
36.8(1-1/2)
Model
PVA-A30AA4
PVA-A36AA4 PVA-A42AA4
3 Nominal Filter size Duct Connection
508X508X25.4 (20X20X1)
477X402 (18-13/16X15-7/8)
508X609.6X25.4 (20X24X1)
579X402 (22-13/16X15-7/8)
Model
PVA-A30AA4
PVA-A36AA4 PVA-A42AA4
A
B
C
D
E
F
G
H
J
1 Gas pipe
534
477 382.6 266.5 1378 737 953.5 792
461
(21) (18-13/16) (15-1/8) (10-1/2) (54-1/4) (29-1/16) (37-9/16) (31-3/16) (18-3/16)
635
579 484.6 317.5 1511 798.5 1053 853.5 563
(25) (22-13/16) (19-1/8) (12-1/2) (59-1/2) (31-7/16) (41-1/2) (33-5/8) (22-3/16)
Ø15.88 (5/8)
2 Liquid pipe
Ø9.52 (3/8)
Appendix 171
P-Series
PUZ-A12NKA7 PUZ-A12NKA7-BS PUZ-A18NKA7 PUZ-A18NKA7-BS PUY-A12NKA7 PUY-A12NKA7-BS PUY-A18NKA7 PUY-A18NKA7-BS OUTDOOR UNIT
48<1-29/32>
404.5<15-15/16>
Air intake Installation bolt pitch
500<19-11/16>
drain hole ø 42
2-U Shaped notched holes
(Foundation Bolt M10<W 3/8>)
32.5<1-9/32> 300<11-13/16> 330<13>
360<14-3/16>
Air intake
Air discharge 22.3 <29/32> Handle for moving
40 <1-19/32>
2-10×21 oval hole
(Foundation Bolt M10
<W 3/8>)
22 <7/8>
23.2 <15/16> LTeerftm..in. aPlocwoenrnseucptipolny wiring Right ... Indoor/Outdoor wiring
Earth terminal Service panel
492 <19-3/8>
154.5 <6-3/32> 310 <12-7/32>
809 <31-7/8>
2- ø 22.2<7/8> 1/2 conduit hole
62 <2-15/32>
164.5<6-1/2> 99.5<3-15/16>
Service port
630 <24-13/16> 320<12-5/8> 8.5 <11/32>
35 ° 43 °
Service panel for charge plug Connection for liquid pipe FLARE ø6.35 (1/4F)
Connection for gas pipe FLARE ø12.7 (1/2F) 185.5 <7-5/16>
PUZ-A24NHA7 PUZ-A30NHA7 PUY-A24NHA7 PUY-A30NHA7
PUZ-A24NHA7-BS PUZ-A30NHA7-BS PUY-A24NHA7-BS PUY-A30NHA7-BS
Unit : inch/cm
PUZ-HA24NHA1
OUTDOOR UNIT
175 <6-7/8> Side Air Intake
Rear Air Intake
600<23-5/8> Installation Feet
2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175<6-7/8>
19 <3/4> 370<14-9/16> 417 <1-1/32>
330 <13>
28<1-3/32>
25 <31/32>
Air Discharge
70 <2-3/4> 57<2-1/4>
61<2-13/32> 40<19/32> 0 53<2-3/32>
41 <1-5/8>
2-12×36 oval holes (Foundation Bolt M10<W3/8>)
Handle Side Air Intake for moving
950 <37-13/32> 322<12-11/16> Earth terminal
LTeerftm..in. aPloCwoenrnseucptpiolynswiring Reight ... Indoor/Outdoor wiring
Service panel Handle for moving
1 2
*1 431<16-31/32> *1 447<17-5/8>
669<26-11/32>
943 <37-1/8> 473 <18-5/8> 23 <29/32>
Front piping cover Rear piping cover
PUZ-A36NKA7 PUZ-A36NKA7-BS PUZ-HA30NHA5 PUZ-A42NKA7 PUZ-A42NKA7-BS PUZ-HA36NHA5 PUY-A36NKA7 PUY-A36NKA7-BS PUZ-HA30NKA PUY-A42NKA7 PUY-A42NKA7-BS PUZ-HA36NKA
PUZ-HA42NKA OUTDOOR UNIT
Side Air Intake
Side Air Intake
Rear Air Intake
225 <8-27/32>
600 <23-5/8> Installation Feet
19 <3/4>
225 <8-27/32>
2-U Shaped notched holes (Foundation Bolt M10<W3/8>)
370 <14-9/16> 417 <16-13/32>
330 <13>
25 <31/32>
Air Discharge
70 <2-3/4>
2-12×36 Oval holes (Foundation Bolt M10<W3/8>)
60 <2-3/8>
362 <14-1/4>
1050 <41-11/32> Earth terminal
40<1-9/16>
56 <2-7/32> 0
53 <2-3/32> 42 <1-21/32>
( ) RLTeeigfrtmh.t.i.n..Pa. lIoncwdoeonronsre/uOcptuipotlndyowoirriwngiring
28 <1-3/32>
*1 442 <17-2/5> *1 450 <17-23/32>
1063 <41-7/8>
Hmaonvdinleg for
1338 <52-11/16> 632 <24-7/8>
Service panel Handle for moving
21
Air intake
369 <14-17/32> 26 <1-1/32>
Front piping cover Rear piping cover
172 Appendix
External Dimensions: MX Model
NAXMMX20A122AA OUTDOOR UNIT
Unit : inch/cm
NAXMMX24A132AA, NAXMMX30A132AA, NAXMMX36A142AA OUTDOOR UNIT
11/16"
15-19/32"
15/32" 23/32" 14-3/16" (Bolt Pitch)
21/32" 1-11/32"
6-21/32" 2-9/16" 8-5/32"
19-11/16" 12-3/8" Air Inlet
6-23/32"
Air Inlet 3-ø(1-5/16") Drain hole
11/16"
Air Outlet
4-(13/32"×13/16") Oval Hole (Foundation Bolt M8)
33-1/16"
1-3/16"
7-7/8"
1-1/32"
13"
1/2"
9-7/16" 27-15/16"
14-3/16"
11-25/32"
2-19/32"
Connecting wire hole
LIQ
Unit B
GAS
LIQ
Unit A
GAS
LIQ 1/4"(ø6.35)FLARE GAS 3/8"(ø9.52)FLARE
NAXMMX42A152AA, NAXMPH20A122AA, NAXMPH24A132AA, NAXMPH30A132AA OUTDOOR UNIT
NAXMMX48A182BA, NAXMMX60A182BA, NAXMPH36A142BA, NAXMPH42A152BA, NAXMPH48A182BA OUTDOOR UNIT
370 <14-9/16> 19 <3/4> 417 <16-13/32>
225 <8-27/32>
Rear Air Intake
600 <23-5/8> Installation Feet
225 <8-27/32>
2-U Shaped notched holes (Foundation Bolt M10<W3/8>)
Side Air Intake
Handle for moving
25 <1>
330 <13>
362 <14-1/4>
70 <2-3/4>
Air Discharge
1050 <41-11/32> Ground for the power supply ("GR"marking position)
42 <1-21/32>
60.5 <2-3/8> 2-12×36 Oval holes (Foundation Bolt M10<W3/8>)
28 <1-3/32>
56 <2-7/32> 39.5 <1-9/16> 0 53 <2-3/32>
Terminal connection From left to right
Fpoowr tehresupply
Fbprooawrntechrhesbuopxply
For the transmission line
Fcoonr tcroolncentration
Ground for the transmission line Ground for concentration control
1338 <52-11/16> 632 <24-7/8>
Ground for the branch box power supply Service panel Handle for moving
Air intake
1067 <42>
426 <16-25/32> 485 <19-3/32>
369 <14-17/32> 26 <1-1/32>
1 2
Front piping cover Rear piping cover
Appendix 173
MX Model
TAC-MKA32BC Branch Box
SUSPENSION BOLT PITCH 320 (12-19/32)
TAC-MKA52BC Branch Box
SUSPENSION BOLT PITCH 320 (12-19/32)
Unit : inch/cm
402 (15-13/16) SUSPENSION BOLT PITCH 24 (1)
402 (15-13/16) SUSPENSION BOLT PITCH 24 (1)
170 (6-11/16) 65
(2-9/16)
TB3B TB3D TB3A TB3C TB3E
TB5 TB2B
TB3B TB3A TB3C
TB5 TB2B
47 (1-27/32)
450 (17-23/32) 209 (8-7/32)
CAP
TO INDOOR UNIT
90 (3-17/32)
72 (2-27/32)
C
B
A
C
B
A
CAP
25
25
25
(1)
(1)
(1)
70
70
(2-3/4) (2-3/4)
12 (1/2)
96 (3-25/32)
280 (11-1/32)
83
87
70
(3-9/32) (3-7/16) (2-3/4)
40 (1-17/32) 5-ELECTRIC WIRE INLET
112 (4-3/8)
TO OUTDOOR UNIT SERVICE PANEL (for LEV, THERMISTOR)
CONTROL COVER CONDUIT PLATE
TERMINAL BLOCK TO M-NET UNIT
TERMINAL BLOCK TO INDOOR UNIT
TERMINAL BLOCK TO OUTDOOR UNIT
SUSPENSION BOLT : W3/8(M10)
REFRIGERANT PIPE FLARED CONNECTION ABC
LIQUID PIPE 1/4F 1/4F 1/4F GAS PIPE 3/8F 3/8F 3/8F
Unit: inch TO OUTDOOR UNIT 3/8F 5/8F
170 (6-11/16) 65
(2-9/16)
47 (1-27/32)
12 (1/2)
450 (17-23/32)
67 (2-9/16)
TO INDOOR UNIT
90 (3-17/32)
72 (2-27/32)
E E DD C C B B AA
25
25
25
25
25
(1)
(1)
(1)
(1)
(1)
70
70
70
70
(2-3/4) (2-3/4) (2-3/4) (2-3/4)
96 (3-25/32)
83 (3-9/32)
280 (11-1/32)
87
70
(3-7/16) (2-3/4)
40 (1-17/32) 5-ELECTRIC WIRE INLET
112 (4-3/8)
TO OUTDOOR UNIT SERVICE PANEL (for LEV, THERMISTOR)
CONTROL COVER CONDUIT PLATE
SUSPENSION BOLT : W3/8(M10)
REFRIGERANT PIPE FLARED CONNECTION A B CD E
LIQUID PIPE 1/4F 1/4F 1/4F 1/4F 1/4F GAS PIPE 3/8F 3/8F 3/8F 3/8F 1/2F
Unit: inch TO OUTDOOR UNIT 3/8F
5/8F
TERMINAL BLOCK TO M-NET UNIT
TERMINAL BLOCK TO INDOOR UNIT
TERMINAL BLOCK TO OUTDOOR UNIT
174 Appendix
americanstandardair.com
© 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Mitsubishi Electric, Lossnay, and the three-diamond logo are trademarks of Mitsubishi Electric Corporation. CITY MULTI, kumo cloud, kumo station and H2i are registered trademarks of Mitsubishi Electric US, Inc. Trane and American Standard are registered trademarks of Trane Technologies plc. All other product names mentioned herein are trademarks or registered trademarks of their respective owners. Use of the AHRI Certified® mark indicates a manufacturer's participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org.
Specifications shown in this brochure are subject to change without notice. See complete warranty for terms, conditions and limitations. A copy is available from Mitsubishi Electric Trane HVAC US LLC.
Printed in the USA
AS_RS_1060_5-21
Adobe InDesign 16.2 (Macintosh) Adobe PDF Library 15.0