Installation Guide for FIMER models including: PVS-10-12.5-15-TL, String Solar Inverter, Solar Inverter, String Inverter, Inverter
PVS-10/12.5/15-TL | Fimer Spa
27 ott 2021 — This Quick Installation Guide is related to the following inverter models: Inverter model. Input MPPTs. DC switch. DC SPD. DC connection.
Inverters - Rheem
File Info : application/pdf, 8 Pages, 5.59MB
DocumentDocumentSolar Inverter PVS-10/12.5/15-TL Quick Installation Guide In addition to what is explained in this quick installation guide, the safety and installation information provided in the product manual must be read and followed. The technical documentation for the product is available at the website. The device must be used in the manner described in the manual. If this is not the case the safety devices guaranteed by the inverter might be ineffective. APPLY HERE THE COMMUNICATION IDENTIFICATION LABEL 1. Inverter models and components This Quick Installation Guide is related to the following inverter models: Inverter model Input MPPTs DC switch DC SPD PVS-10-TL-SX PVS-12.5-TL-SX 2 PVS-15-TL-SX PVS-10-TL-SY PVS-12.5-TL-SY 2 PVS-15-TL-SY Yes Type 2 Yes Type 1+2 The -SX inverter models can be equipped with the following options: DC connection 4 input strings AC SPD Type 2 4 input strings Type 2 AC connection AC quick fit connector AC quick fit connector Option ;APD inverter model suffix ;AFD inverter model suffix ;DISPLAY inverter model suffix Description · Inverter equipped with PID recovery functionality · Inverter equipped with Arc Fault Detection functionality · Inverter equipped with display on the front cover E READ THE MANUAL For the inverter with ";APD", ";AFD" and ";DISPLAY" suffixes refer to the manual for settings and safety related information D NOTE The inverter model should be chosen by a specialized technician who has a good knowledge of the installation conditions, the devices that will be installed externally, and whether it will eventually be integrated into an existing system. 1.1 Main inverter components Inverter external view 01 Inverter 02 Heatsink 03 Synoptic (LED icons) 04 Protective earth (PE) external connection point 05 Mounting bracket 07 DC disconnect switch 08 Signals connection box 09 AC quick fit connector 10 USB connector for accessories board 11 Ethernet 1/2 connectors 12 Digital input and RS485 connector 13 Quick fit input connectors 14 Wi-Fi antenna connector 15 Smart button 16 Anti-condensation valve 17 AC output connector 18 Side bracket screws 19 Padlock hole 20 Digital input and RS485 cable gland (M20) 21 Ethernet 1/2 cable gland (M25) 23 AC cable gland 25 Handles (optional) 26 Display 25 01 18 04 19 05 26 16 03 08 08 18 20 19 21 07 09 02 23 09 14 15 17 12 10 11 13 E READ THE MANUAL See the manual for details on the connection of the communication and control signals. 2 2. Labels and Symbols The labels on the inverter show the conformity marking, main technical data and identification of the equipment and manufacturer. D NOTE The below labels are intended as an example only. Regulatory and identification Label A Certification marks Made in Italy A B Inverter model SOLAR INVERTER MODEL: PVS-XX-TL-YY DIN V VDE V 0126-1-1 PROTECTIVE CLASS: I C Main technical data B D IP protection rating Vdc max C Vdc Operating Range Vdc MPP CH1 Vdc MPP CH2 Idc max CH1 Idc max CH2 Isc max (CH1/CH2) Vacr fr Sr Smax Pacr (cos= 1) Pacr (cos= ± 0.9) Adj cos Iac nom Iac max E Operating temperature range F Discharge time G Inverter Part Number Serial Number · Inverter access point SSID: FIMER-YYWWSSSSSS H · "Host Name": http://FIMERYYWWSSSSSS.local · It is required to register the inverter in Aurora Vision. D IP65 -XX to +XX °C -XX to +XX °F EI Production date: WWYY where: WW (week) YY (year) F XX minutes J Manufacturer PN: PPPPPPPPPPP WO:XXXXXXXXXXXX G SO: SXXXXXXXX SN:YYWWSSSSSS I QXX wk: WWYY H J Fimer S.p.A. Via Tortona, 25 I 20144 Milano (MI) Communication identification label L WLAN (Wi-Fi) and ETH1/ETH2 (Ethernet) MAC addresses Product Key. To be used: · as wireless access point password · to access to the Web UI as M username and password in case of lost credentials · to commission inverter using FIMER "Installer for Solar Inverters" APP. WLAN MAC: XX:XX:XX:XX:XX:XX ETH1 MAC: XX:XX:XX:XX:XX:XX ETH2 MAC: XX:XX:XX:XX:XX:XX Remove and apply 1. on the Quick Installation Guide L QR Code: To be used to commission H N inverter, using FIMER "Installer M for Solar Inverters" app, for N claiming process. SN Inverter: YYWWSSSSSS PK: 0000-0000-0000-0000 A ATTENTION The labels placed on the equipment absolutely MUST NOT be removed, damaged, dirtied, hidden, etc. In the manual and/or in some cases on the equipment, the danger or caution areas are indicated with signs, labels, symbols, icons. Simbol Descriprion Always refer to instruction manual General warning - Important safety information Dangerous voltage Hot surfaces Protection rating of equipment ,3;; Temperature range Without insulation transformer 3. Lifting and transporting Transportation and relocation The transportation of the device, in particular via land transportation, must be made with adequate means and ways to protect the parts from violent impacts, humidity, vibrations, etc. A ATTENTION If the package is stored correctly, it can withstand a maximum load of 5 stacked pallet (2 units each pallet). Lifting The means used for lifting must be suitable to bear the weight of the equipment. Weight of the equipment Model All models Weight 29.6 Kg / 65lb Unpacking and inspection The packaging components must be removed and disposed according to the applicable regulations of the country where the device is installed. Upon opening the packaging, check the integrity of the equipment and verify that all the components are present. If you notice defects or deterioration, stop the operations and call the carrier, as well as inform FIMER Service immediately. Please keep the packaging in the event it has to be returned; the use of inadequate packaging will void the warranty. Always store the Quick Installation Guide, all the supplied accessories in a safe place. 4. Installation planning General recommendation on installation position · Refer to Technical data table to check the required environmental conditions (protection rating, temperature, humidity, altitude, etc.). · The installation location shall be easily accessible. · Installation of the unit in a location exposed to direct sunlight is NOT acceptable. (Add awning in case of direct sunlight installation). · Final installation of the device must not compromise access to any disconnection devices that may be located externally. · Do not install in small closed rooms where air cannot circulate freely. · Always ensure that the flow of air around the inverter is not blocked so as to prevent overheating. · Do not install in locations where flammable substances or gases may be present (minimum distance 3 m). · Do not install on wooden walls or other flammable supports. · Install on a wall or strong structure suitable to bear the weight. · Do not install in rooms where people live or where the prolonged presence of people or animals is expected, because of the high noise that the inverter produces during operation. The level of the sound emission is heavily influenced by where the appliance is installed (for example: the type of surface around the inverter, the general properties of the room, etc.) and the quality of the electricity supply. · All installations over 6561 ft (2,000 meters) must be valued taking in consideration the derating reported in the datasheet. Tilting admittance The unit can be installed in vertical with a maximum inclination as indicated in the figures below. 5° MAX 5° MAX Direct and alternating current, respectively Positive and negative pole of the input voltage (DC) Obligation to use protective clothing and/or personal protective equipment Point of connection of the protective ground Risk of electric shock.The discharge time (quantified in the figure by the number XX) of the stored energy after de- ;;PLQXWHV energizing of the Inverter from both DC side and AC side. 3 Distances · Maintenance operations from FIMER service could entails removing the front cover. Always observe the required installation safety distances in order to allow routine check and maintenance operations. · Provide a sufficient working space in front of the inverter that allows to removing the front cover (FIMER service only) and to allow wiring connections. · Install at a height which takes into consideration the weight of the unit and in a position which is suitable for servicing, unless suitable means will be provided to carry out these mentioned operations. · If possible, install at eye-level so to allow to easily check the: - synoptic (03). - display (26). Only in inverter model with ;DISPLAY suffix. · Do not install any object (e.g. AC or DC cables) that could be damaged by overheating from outgoing hot air flow coming from top side. In case of this kind of installation needs, please evaluate the installation of a proper air deflector. Always respect the minimum distances required. · Respect the minimum distances from surrounding objects that could prevent the inverter installation and restrict or block the air flow: A = 70cm (27") B = 50cm (20") C = 20cm (8") D = 20cm (8") E = 50cm (20") B A C D E A ATTENTION Please check the manual for some particular scenarios that may vary the minimum clearance distances. Installation of multiple units · In case of installation of multiple units in the same place, position the inverter side by side paying attention to keep the minimum clearance distance G of 30cm/12" (measured from the outer edge of units). 5. Supplied Component list Component Q.ty Vertical mounting bracket (05) 1 AC quick fit connector (09) + locking clip 1 + 1 Two-hole gasket (6mm Ø) for M20 Digital input and RS485 1 + 1 cable gland (20) and cap Three-hole gasket (6mm Ø) for M25 Ethernet 1/2 cable gland (21) and caps 1 + 2 Three-hole gasket (7mm Ø) for M25 Ethernet 1/2 cable gland (21) and caps 1 + 2 M6 screw + M6 serrated lock washers to clamp the earth cable on the Protective Earth (PE) external connection point (04) Eyelet cable lug (16mm2 wire) for Protective earth (PE) external connection point (04) 1 + 2 1 Digital input and RS485 counterpart (12) 1 Wireless antenna (14) 1 M5 screws (with washers) for mechanically securing the 2 inverter to the bracket (18) South Africa network standard label 1 G G Technical documentation 1 If the space available does not allow this arrangement, position the inverters in a staggered arrangement so that heat dissipation is not affected by other inverters below. Respect the following minimum clearance distances H of 100cm/39" and I of 30cm/12". H I I H H 6. Assembly instructions Bracket installation The mounting bracket can be used to install the inverter on a vertical support. · Position the mounting bracket (05) perfectly level on the support and use it as drilling template. D NOTE It is the installer's responsibility to choose an appropriate number and distribution of attachment points. The choice must be based on the type of support (wall, frame or other support), the type of anchors to be used, and their ability to support 4 times the inverter's weight (4x29.6Kg/65lbs=118.4Kg/260lbs for all models). Depending on the type of anchor chosen, drill the required holes (4 minimum) to mount the bracket. Put at least 2 screws in the upper side and at least 2 in the lower side. · Attach the bracket (05) to the support. A ATTENTION Please check the product manual for "Wireless signal environmental checks", "Installations at high altitudes" and "Installations with a high level of humidity". D NOTE The final installation of the inverter must not compromise the access to any disconnection devices located outside. D NOTE Refer to the warranty conditions to evaluate the possible exclusions related to an improper installation. 4 Assembly the Inverter to the bracket A ATTENTION It is recommended to use the handles (that have to be ordered separately) to handle and safety install the inverter. A ATTENTION Risk of injury due to the heavy weight of the equipment. Always consider the center of gravity of the enclosures while lifting. · Lift the inverter up to the bracket (05) (using the handles (25) or M8 eyebolts) and insert the two sides anchor points (placed on sides of the wall bracket) into the two slots on the inverter. Check that the anchor points has been correctly inserted in the slots before releasing the inverter. · Remove the handles (25) or eyebolts and tighten the supplied 05 two side bracket screws (18) (Tightening torques 25 3.5 Nm) to avoid the tilting of the bottom part of the inverter. · A padlock can be installed to lock the inverter to the bracket so that it cannot be disassembled by outsiders. 7.2 Characteristics and sizing of the line cable The AC cables must be connected to the AC output connector (17) using the specific AC quick fit connector (09) supplied. AC conductor cable Cable diameter range · 11...19 mm or 19...26mm based on the type of seals installed Conductor section cross · 6mm2...16mm2 (with plastic collar ferrule) accepted by the AC quick fit connector. Conductor material copper 7.3 Protection switch under load (AC switch) and differential protection To protect the AC connection line of the inverter, it is recommended to install a protection device against overcurrent and earth leakages with the following features: Load protection breaker Type Voltage/current rating Magnetic protection Number of poles Differential protection type Differential sensitivity PVS-10-TL PVS-12.5-TL PVS-15-TL Automatic circuit breaker with thermalmagnetic protection 400Vac 400Vac 400Vac min25A (*) min32A (*) min32A (*) Magnetic curve B/C 3W (3 phases without neutral wire) or 4W (3 phases with neutral wire). A/AC 300 mA (*): please consider thermal and other derating when selecting the current rating of the protection equipment for your application. 7.4 Connection on the Protective earth (PE) cable 18 · Remove the protective cover from the connector of the wireless antenna located on the bottom side of the inverter. Install the wireless antenna by screwing it into the specific connector (14). A ATTENTION For connection to the network in South Africa: according to NRS097-2-1 requirements, at the end of installation it is mandatory to apply the label (supplied with the inverter) near to regulatory label. · Strip the cable. · Install the supplied M6 cable lug on the earth cable. · Install the earth wire on the Protective earth (PE) external connection point (04) following the installation sequence (Tightening torque 4 Nm): - Serrated washer - Earth cable - Serrated washer - M6 screw 7.5 AC output cables connection A ATTENTION Before carrying out any operation, check that any external AC switch downstream to the inverter (grid side) is in OFF position applying LOTO procedure on it. 7. AC grid output connection 7.1 Characteristics and sizing of the protective grounding cable A ATTENTION Any failure of the inverter when it is not connected to earth through the appropriate connection point is not covered by the warranty. The connection of the AC cable must be made on the AC output connector (17), located on the bottom side of the inverter, using the AC quick fit connector (09). · Unscrew the AC cable gland (23) installed on the AC quick fit connector (09). 1191--2169m mmm mmm The earth connection can be made: · On the Protective Earth (PE) external connection point (04). B WARNING The cross section of the protective earthing conductor must have same cross section as the phases cables and its minimum must be 10 mm2 (Copper wire). · On both Protective Earth (PE) external connection point (04) and on the AC quick fit connector (09) using cables having same cross section as the phases cables. A ATTENTION Installation of a second protective earth cable is also required by regulations in force in certain countries of installation. 1191--2169m · Remove the internal screw terminal block. Press the 2 retain clips and pull out the screw terminal block. A ATTENTION On the connector cable gland 2 gasket are installed that can be used in combination to accept a 11...26mm diameter cable. - Cable diameter 11...19mm. Default configuration (both gasket installed). - Cable diameter 19...26mm. Remove the reducing clamping range gasket. 5 X · Pass the AC cable Y through the AC cable gland (23). · Strip the AC cable and wires X 12...16 mm 0.47...0.63 " Y 75...80 mm 2.95...3.15 " · Secure the AC quick fit connector. Install and screw the holding clip. · Install ferrule with plastic collar on the wires. · Install the wires (based on the AC connection type) respecting the connections as indicated on the screw terminal block (L1=R ; L2=S ; L3=T): A.Five-cores cable (L1, L2, L3, N and PE). B.Four-cores cable (L1, L2, L3 and N). C.Four-cores cable (L1, L2, L3 and PE). D.Three-cores cable (L1, L2, L3). L3 L2 L1 N PE T SR M4 1.5Nm A ATTENTION The AC quick fit connector must not be subject to tensile forces (examples: do not connect weights to the AC cable, do not leave excess cable windings hanging, etc). 8. Input connection (DC) For the strings connections it is necessary to use the DC input quick fit connectors (13), located on the bottom side of the inverter. 13 A ATTENTION In case of a wrong phase sequence the inverter will not connect to the grid and it will provide an error state. · Re-install the screw terminal block inside the AC quick fit connector. A ATTENTION Push the screw terminal block till a double "click" will be heared. · Tighten the cable gland ring (7.5Nm). A ATTENTION Make sure the cable glands are properly sealed to ensure to keep IP65 protection degree. The input connectors are divided into 2 groups (one group for each input MPPT). For each MPPT 2 pairs of quick fit connectors are available. Respect the Maximum DC input power for each MPPT as follow: MPPT IN1 IN2 PVS-10-TL 17A / 7.8kW 17A / 7.8kW PVS-12.5-TL 18A / 8.3kW 18A / 8.3kW PVS-15-TL 22A / 10kW 22A / 10kW 8.1 Preliminary operations to the connection of the PV generator 7.5.1 Connection of AC quick fit connector to the inverter · Pull out the protective cap from the AC output connector (17). · Connect the AC quick fit connector (09) to the AC output connector (17). A ATTENTION Push the connector till a double "click" will be heared. · Checking the correct polarity of the strings · Checking of leakage to ground of the photovoltaic generator · Checking of strings voltage · Installation of quick-fit connectors 8.2 Connection of the input strings B WARNING When the photovoltaic panels are exposed to sunlight they provide continuous DC voltage to the inverter. To avoid risks of electrical shock, all wiring operations must be carried out with the DC disconnect switches (internal (07) and external to the inverter) and external AC disconnect switches OFF. · Connect all the strings required by the system by pushing the quick fit connectors in the right position. A ATTENTION Using coupling parts that are not compliant with the quick fit connector models on the inverter could cause serious damage to the unit and lead to invalidation of the warranty. 6 A ATTENTION Refer to document "String inverters - Product manual appendix" available at www.fimer.com to find out the manufacturer and model of quick fit connector used on the inverter. Click Click A ATTENTION Check that protective caps are installed on unused connectors. This is necessary for the inverter seal and to avoid any damage to the unused connectors which may be used at a later time. A ATTENTION The quick fit connectors must be properly installed. After the installation make sure the connectors are correctly locked through the clips. · Login or Sign-In to Aurora vision account. · Tap on "Commissioning wizard". A QR code scanner will be opened. · Scan the QR code on the Communication identification label WLAN MAC: XX:XX:XX:XX:XX:XX and connect to inverter network. ETH1 MAC: XX:XX:XX:XX:XX:XX D NOTE The name of the Wi-Fi ETH2 MAC: XX:XX:XX:XX:XX:XX network created by the inverter will be: FIMER-YYWWSSSSSS (10 Remove and apply 1. digit Inverter SN). on the Quick Installation Guide D NOTE After this step wait 10 SN Inverter: YYWWSSSSSS seconds to allow the Wi-Fi connection PK: 0000-0000-0000-0000 Once connected, the commissioning wizard will start. 10.1 COMMISSIONING WIZARD 10.1.1 Network configuration. · Choose the connection type (ethernet or wireless) and set the related parameters. D NOTE This step can be skipped and performed later (via WebUI). 9. Instruments The synoptic (03) allows to view inverter status conditions to be analyzed in greater depth by consulting the manual. POWER Solid when the inverter is working correctly. Flashes when checking the grid or if there is insufficient sunlight. WLAN Indicates the status of the Wi-Fi or Ethernet communication lines. · Once network parameters were setted, tap on "Next". 10.1.2 Date and Time. · Set the Date, Time and Time zone (The inverter will propose these fields if connected to internet). · Once date and time were setted, tap on "Next". ALARM The inverter has detected an anomaly. The anomaly is shown on the "EVENTS" section of the internal webserver. GFI Ground fault on the DC side of the PV generator. The error is shown on the "EVENTS" section of the internal webserver. D NOTE The icons, in various combinations, can indicate multiple conditions other than the original single condition; see the various descriptions on the product manual. 10. Commissioning 10.1.3 Inverter configuration. Country standard · Set the grid standard of the country in which the inverter is installed. Some Country standards have different grid voltage that should be setted during this step. The inverter can be commissioned in a simple and intuitive way through the Installer for solar inverters APP for mobile devices. D NOTE The commissioning can be done also via WebUI. Once powered, the inverter will create a Wi-Fi network (SSID: FIMER-YYWWSSSSSS). Connect to this Wi-Fi and use the Product Key as password (digit also the dash "-" characters) and open an internet browser. Enter the IP 192.168.117.1 and the commissiong page will be showed. Subsequently is possible to access the WebUI use the admin password 0010. For complete description refer to product manual at www.fimer.com · Supply the inverter with DC input voltage from the photovoltaic generator and via AC grid voltage. A ATTENTION The inverter configuration can be also performed with only one supply source (DC or AC). A ATTENTION With DC supply, make sure that the irradiation is stable and adequate for the inverter commissioning procedure to be completed. · Open the " Installer for solar inverters" APP. · Confirm the settings by clicking "Save". The configuration wizard is complete and the inverter will reboot. · If the outcome of the preliminary checks on the grid parallel is positive, the inverter connects to the grid and starts to export power to the grid. The "Power" LED remains fixed on while the "Alarm" and "GFI" LEDs are off. D NOTE To address any problems that may occur during the initial stages of operation of the system and to ensure the inverter remains fully functional, you are advised to check for any firmware updates in the download area of the website www.fimer.com or at https://registration.solar.fimer.com (instructions for registering on the website and updating the firmware are given in the product manual). 7 11. Features and Technical Data Input side Absolute maximum DC input voltage (Vmax,abs) Start-up DC input voltage (Vstart) Operating DC input voltage range (Vdcmin...Vdcmax) Rated DC input voltage (Vdcr) Rated DC input power (Pdcr) Number of independent MPPT Recommended maximum PV array power (PPV, max) Maximum DC input power for each MPPT (PMPPT,max) MPPT DC voltage range (VMPPTmin ... VMPPTmax) at Pacr Maximum DC input current (Idcmax) for each MPPT Maximum input short circuit current for each MPPT Maximum return current (AC side vs DC side) Number of DC inputs pairs for each MPPT DC connection type Type of PV panels that can be connected according to IEC 61730 Input protection Reverse polarity protection Input over voltage protection for each MPPT Photovoltaic array isolation control Residual current monitoring Unit (leakage current protection) DC switch rating for each MPPT (version with DC switch) String Fuse Input current monitoring Output side AC Grid connection type Earthing system Rated AC power (Pacr @cosf=1 ) Maximum AC output power (Pacmax @cosf=1) Maximum apparent power (Smax) Rated apparent power (Sr) Maximum reactive power (Qmax) Nominal power factor and adjustable range Rated AC grid voltage (Vac,r) Rated Output Current (Iac nom) Maximum AC output current (Iac,max) Contributory fault current Rated output frequency (fr) Output frequency range (fmin...fmax) Max DC Current Injection (% of Iac,max) Maximum AC cable AC connection type Output protection Anti-islanding Protection Maximum external AC overcurrent protection Output overvoltage protection Operating performance Maximum Efficiency (max) Weighted Efficiency (EURO) Environmental Operating ambient temperature range Storage temperature Relative Humidity Sound pressure level, typical Maximum operating altitude Environmental pollution degree classification for external environments Environmental class Physical Inverter typology Environmental Protection Rating Cooling System Dimension (H x W x D) Weight Overvoltage rating as per IEC 62109-1 Safety Safety class Insulation Level Marking PVS-10-TL PVS-12.5-TL PVS-15-TL 10200 W 14500 Wp 7800W 17A 1100 V 250...500V (default 360V) 200...1000 V 620V 12760 W 15300 W 2 18125 Wp 21750 Wp 8300W 10000W 460-850V 18A 22A 30 A Negligible in normal operating conditions (6) 2 PV quick fit connector (3) Class A Yes, from current limited source SPD Type 2 / Type 1+2 (optional) Yes, according to IEC 62109-2 or according to local regulation Yes, according to IEC 62109-2 Rating DC-PV1. 50A@600Vdc, 40A@800Vdc, 30A@1000Vdc Fuseless String level 10000 W 10000 W 10000 VA 10000 VA 6000 VAR 14.5 A 16 A Three phase (3W+PE or 4W+PE) TN-S, TN-C, TN-CS, TT 12500 W 15000 W 12500 W 15000 W 12500 VA 15000 VA 12500 VA 15000 VA 7500 VAR 9000 VAR > 0.995; 0...1 inductive / capacitive 380V, 400V (1) 18.1 A 21.7 A 20 A 23 A Iac,max x 1,15 50 Hz / 60 Hz 47...53 Hz / 57...63 Hz (2) < 0.5%*Iac,max 16 mm2 copper AC quick fit connector 25 A According to local standard 32 A 32 A SPD Type 2 98.4% 98.1% 98.5% 98.2% 98.5% 98.2% -25...+60°C (-13...140 °F) with derating above 45 °C (113 °F) -40°C...+85°C / -40°F...185°F 4...100 % with condensation 40 dB(A) @ 1m 45 dB(A) @ 1m 45 dB(A) @ 1m 4000 m (13123 ft) with output power [Pout ] linear derating above 2000m (6561 ft) (5) 3 Outdoor Grid connected, Double stage, Transformerless IP65 Natural H = 568.2 mm / 22.37" (644mm / 25.35" with AC quick fit connector) ; W = 473.6 mm / 18,64" ; D = 207 mm / 8,15" 29.6 Kg / 65lb II (DC input) III (AC output) I Transformerless CE (4) ,RCM 1. The AC voltage range may vary depending on specific country grid standards. 2. The Frequency range may vary depending on specific country grid standards. 3. Please refer to the document "String inverters Product manual appendix" available at www. fimer.com for information on the quick-fit connector brand and model used in the inverter. 4. Hereby, FIMER S.p.A. declares that the radio equipments (radio module combined with the inverter) are in compliance with the Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.fimer.com 5. @ 4000m (45° C ambient temperature), the output power (Pout) is reduced by 15%. 6. In the event of a fault, limited by the external protection envisaged on the AC circuit. Features not specifically mentioned in this data sheet are not included in the product. For more information please contact your local FIMER representative or visit: fimer.com FIMER_PVS-10_12.5_15-TL_Quick Installation Guide_EN_RevB 27-10-2021 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. FIMER does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of FIMER. Copyright© 2021 FIMER. All rights reserved. 8