Owner's Manual for HANNA Instruments models including: pH502, pH502421-2, pH502 pH Digital Controllers, pH502 pH, Digital Controllers, Controllers

pH Digital Controllers 16

เครื่องวัดและควบคุมค่ากรดด่าง pH Controller รุ่น pH502421-2


File Info : application/pdf, 1 Pages, 6.79MB

PDF preview unavailable. Download the PDF instead.

Catalog-pH502421-2
Specifications
Range Resolution Accuracy (@25°C/77°F) Input Impedance pH Calibration Temperature Compensation
Outputs
Set Point Relay
Alarm Relay
Power Supply Power Consumption Over Current Protection Environment Dimensions Weight
Ordering Information

pH502
000 to 1400 pH; -99 to 120°C 001 pH; 01°C
±002 pH; ±05°C
1012 Ohm automatic, one, two or three point, at pH 401, 701, 1001
automatic (with Pt100 probe) or manual from -99 to 120°C
digital: RS485 bi-directional opto-isolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC 1 or 2 contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load) or 1 or 2 Solid State Relay (SSR), 1A, 250 VAC (resistive and inductive load), fuse protected (2A, 250V fast fuse) one contact output SPDT, 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (5A, 250V fuse) 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz 15 VA
400 mA 250V fast fuse
0 to 50°C (32 to 122°F); RH max 95% non-condensing panel cutout:140 x 140 mm, instrument: 144 x 144 x 170 mm 16 kg (35 lb) Each pH 502 model is supplied complete with mounting brackets and instructions Choose your configuration pH502421-1 Dual setpoint with SSR relay, on/off and PID controls,
analog output, 115V pH502421-2 Dual setpoint with SSR relay, on/off and PID controls,
analog output, 230V
Line ID: @neonics

       Tel: 098-479-5684  061-8268939 E-mail: sale@neonics.co.th  sale@tools.in.th

pH502
pH Digital Controllers
with Matching Pin and PID Control
· CAL CheckTM · Alerts users of calibration status
· ATC · Automatic temperature compensation
· 3 Point Calibration · Up to three point calibration

16

Process Instrumentation

The pH502 series of controllers offer many features to increase the level of control available in your plant These instruments can be configured to utilize P, PI, PID controlling With this feature, the pH502 takes the place of three instruments that only allow one configuration each The pH502 line includes models that incorporate control through analog output to drive any compatible device, such as an electrovalve or pump The solid state relay is available to ensure maximum life of the switching device Each model has a differential input for a grounding bar to extend electrode life
Fail Safe Alarm System protects against power interruption or line failure 1, 2 or 3 point automatic calibration and manual or Automatic Temperature Compensation complete the features of this controller

controllers

16.31

