User Manual for SHOWVEN models including: BT01, BT02, Sparkular BT01, Cold Spark Fountain Machine, Sparkular BT01 Cold Spark Fountain Machine

喷花机使用说明书英文版(压缩版)

Co2 Special Effects, Co2 Systems, Cold Spark Machine, Co2 Tank / Co2 Cylinder Information

SPARKULAR USER MANUAL

1. Production Overview BT01 is a revolutionary special effect system. It uses a newly designed delivery control system for a fountain style sparks


File Info : application/pdf, 20 Pages, 412.93KB

CryoFX-showven-sparkular bt01-min
SPARKULAR USER MANUAL
V1.1
Showven Technologies Co.,Ltd.

SPARKULAR USER MANUAL
Safety
Warnings and Cautions
These are designed to alert your attention to hazards and important information that assists you in carrying out your activities on this machine safely and efficiently. Examples and descriptions of safety statements have been provided as follows:
WARNING: A WARNING ALERTS YOU TO HARMFUL OR POTENTIALLY LETHAL ACTIVITIES. A DESCRIPTION OF THE HAZARD IS GIVEN AND THE CONSEQUENCES OF IGNORING THEM.
Eye Protection
THE EYE PROTECTION WARNING ICON IS SHOWN TO INDICATE THAT YOU MUST BE PROTECT YOUR EYES WHEN CLOSE TO THE MACHINE DURING MACHINE OPERATION.
Injury Voltages
WARNING: DANGEROUS VOLTAGES ARE PRESENT IN THIS MACHINE AND CONTROLLER WHEN ELECTRICAL POWER IS APPLIED. THERE IS A DANGER OF INJURY FROM ELECTRIC SHOCK. UNDER NO CIRCUMSTANCES ARE YOU TO ATTEMPT TO OPEN THE MACHINE AND CONTROLLER OR ATTMPT TO REMOVE OR ADJUST ANY COMPONENTS FITTED WITHIN THE MACHINE AND CONTROLLER. ONLY FULL TRAINED SERVICE ENGINEERS ARE QUALIFIED TO OPEN THE MACHINE AND CONTROLLER.
Caution Against Liquids
WARNING: USE CAUTION SO THAT ANY LIQUIDS DO NOT WET THE MACHINE. KEEP THE MACHINE AND CONTROLLER DRYAND NOT USE ON RAINY OR SNOWY DAYS UNLESS COVERED.
Warning
PLEASE PREVENT ANYTHING FROM ENTERING THE FOUNTAIN NOZZLE. IF THIS HAPPENS PLEASE CLEAR OBSTRUCTIONS BEFORE CONTINUING OPERATION. PLEASE PREVENT MACHINE FROM DROPING WHEN INSTALLING "DAMAGE CAN OCCUR". NEVER TOUCH THE NOZZLE OF SPARKULAR, DANGER OF GETTING BURNT. NEVER TOUCH THE SPARKS WHICH SHOOTING OUT FROM THE NOZZLE. COVER THE NOZZLE OF SPARKULAR IS PROHIBITED. MAKE SURE LID OF FEEDBING HOPPER IS CLOSED WHEN USE SPARKULAR FOR BETTER HEAT DISSIPATION, BLOCK THE AIR INTAKE AND OUTLET IS PROHIBITED.
1

Safe Distance
KEEP AUDIENCE AND FLAMMABLE MATERIALS AT A MINIMUM SAFETY DISTANCE OF 10 FEETS. ENSURE THAT CHILDREN, ANIMALS AND UNAUTHORIZED PERSONS CAN'T ACCESS TO SPARKULAR. MAKE SURE SPARKS SHOOT OUT FROM SPARKULAR CAN NOT TOUCH ANY OBJECTS IN THE AIR.
In Case of Emergency
IF THE MACHINE NEEDS TO BE STOPPED QUICKLY DUE TO AN EMERGENCY, PRESS THE "PAUSE" / "STOP" KEY ON THE CONTROLLER TO STOP THE MACHINE AND SWITCH THE MACHINE POWER SWITCH ON THE PANEL OF THE MACHINE TO THE "OFF" POSITION. IF NECESSARY CALL FOR MEDICAL ASSISTANCE AS REQUIRED.
Clear Material
PLEASE INSPECT FOUNTAIN NOZZEL OF SPARKULAR MACHINE BEFORE USE AND CONFIRM WHETHER THERE ARE ACCUMULATED GRANULES. PLEASE CLEAN OUT EXCESS BY INVERTING THE UNIT TO CLEAN OUT PORT. EACH TIME BEFORE AND AFTER THE SHOW PLEASE RUNNING CLEAR MATERIAL ON HOST CONTROLLER OR DMX CONSOLE. BEFORE DELIVERY THE MACHINE OR NOT USE THE MACHINE IN A LONG TIME, PLEASE POURING THE HC8200 OUT FROM HOPPER, AND STORE THE REMAINING HC8200 IN A DRY SEALED BOTTLE FOR NEXT TIME USE.
Power Supply Requirement
PLEASE SELECT QUALIFIED POWER CONNECTOR ACCORDING TO THE REQUIRMENT OF SPARKULAR. IF NECESSARY PLEASE CONTACT SHOWVEN DIRECTLY FOR SUGGESTION. PLEASE NOTE: ONE POWER SUPPLY CABLE CAN SUPPORT A MAXIMUM OF 6 SPARKULAR (BT01) / 3 SPARKULAR (BT02). EACH MACHINE CAN BE CONNECTED INDIVIDUALLY OR WITH THE POWER-CON SERIES CABLES SUPPLIED.
Difference
PLEASE NOTE: THE VOTAGE OF MODEL BT01 AND BT02 IS DIFFERENT. BT01: AC 200V~240V BT02: AC 100V~120V
2

1. Production Overview

1) Description

BT01 is a revolutionary special effect system. It uses a newly designed delivery control system for a fountain style sparks special effect, it can be controlled easily with DMX communication and compatible with other stage effects equipment.

Model Dimension Weight Input
Work Power Work Temp. Casing Fountain Height Lifetime Interface type

BT01/BT02 200×218×305mm 8.5kg AC 220V 50/60Hz (BT01) AC 110V 50/60Hz (BT02) 500W -10¥ ~ 50¥ Anti-flaming ABS 1.5m ~ 5m adjustable >3 years DMX in/out, AC power in/out

2) Instructions

The Sparkular system has two main components: Sparkular BT01/BT02 and Host Controller ZK6200/ZK6300. BT01/BT02 with series built-in safety features that is readable on the Sparkular and host controller. Please note the read out function is not applicable for other DMX console. Below descriptions will help to learn the operation and function of SPARKULAR systems.

3) Characteristics

A)

Safe, no gunpowder, no smoke and pyro smell

B)

Up to 10-20min effects time after fill up

C)

Standard DMX 512 control

D)

Adjustable height from 1.5-5m.

E)

Easy set up and tear down

F)

Indoor / outdoor usage

G)

Flexible for rehearsal

H)

Environmental friendly

I )

Patented and Originality technology

4) Operation Panel:

3

a) LCD display: Shows operation menu and status of the machine.
b) LED Displaying Area: READY: Flash means machine is preparing, LED keeps on means ready to operate DMX: Flash means DMX signal is connected, light OFF means there is no DMX signal FAULT: Light ON when error occurs HEAT: Light ON when system is heating up
c) Control Button Area MENU: switch through setup menu DOWN: parameter down UP: parameter up ENTER: confirm and save parameters
d) Interface and Plugging Area POWER IN: power in POWER OUT: power out DMX IN: DMX Communication Signal Input DMX OUT: DMX Communication Signal Output
e) Radio Frequency Identification Area RFID card comes together with HC8200, it is a safety design, allow machines to identify the parameter and types of consumable it adding to the hopper of machine. It is obligatory to swiping the card before adding the consumable HC8200 to the hopper of machine. Note: Please note that the card enables the unit for 10-20 minutes of operation (which is the amount of time each bag of HC8200 last). The RFID card is disposable and it is disabled after it has been swiped.
5) Interface
a) Main Interface i) Displays DMX Address ii) Display inner core temperature of machine iii) Display error information when error occurs
4

Error Information
Error Information E0 System IC E1 Motor Protect E2 Temp. Sensor E3 P Temp. Over E4 Time Remain E5 K Temp. Over E6 Heating Failure E7 Tip Over

Explanation Systematic error Over current protection of the motor Temperature sensor is not connected or damaged The equipment stops due to the over-temperature of the chassis Activated time for the machine is not enough, please swip RFID card The equipment stops due to over-temperature of the inner core Heating fail, problem on heating PCB of mainboard Tilt sensor activated when machine slant more than 45 degree.

b) Setting Menu Press "MENU" switch through setup menu.

Option

Range

Explanation

Set DMX Address

1-512

Set DMX Address.

Fountain Height

1-10

10 gears of fountain height, manually adjust the height of sparks.

Manual Heat

On/Off

Auto preheat function switch after turn on machine. If it is ON, machine will heating up automatically after turn on. If it is OFF, operator need to start heating up on HOST CONTROLLER or DMX console.

Manual Fountain

On/Off

Start firing manually, only for test.

DMX address setup for SPARKULAR:
Sparkular No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
DMX Address 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35
Note: DMX address must set according to above rules. If use together with HOST CONTROLLER ZK6200/6300, each unit of SPARKULAR must use different DMX address, otherwise it may leads to signal interference.

5

c) Advanced Interface
Press "MENU" for 3 seconds, operator can enter the Advanced Interface. Press "MENU" switch to different options, and press "MENU" for 3 seconds, return to the main interface.

Option

Range

Explanation

Set Temperature

Range

Setup SPARKULAR inner core temperature

Wireless Control

On/Off

Wireless On/Off, for wireless version only

LCD Backlight

On/Off

LCD Backlight On/Off

Density@ Height 1

30-50

Adjusts the sparks density of Height gear 1*

Density@ Height 2

30-50

Adjusts the sparks density of Height gear 2*

Density@ Height 3

30-50

Adjusts the sparks density of Height gear 3*

Density@ Height 4

30-60

Adjusts the sparks density of Height gear 4*

Density@ Height 5

30-70

Adjusts the sparks density of Height gear 5*

Density@ Height 6

40-100

Adjusts the sparks density of Height gear 6*

Density@ Height 7

40-100

Adjusts the sparks density of Height gear 7*

Density@ Height 8

40-100

Adjusts the sparks density of Height gear 8*

Density@ Height 9

40-100

Adjusts the sparks density of Height gear 9*

Density@ Height 9 Mode Selection Default Parameter Motor Protect Power Selection

40-100 Factory Mode User Mode
On/Off 220/110Vac

Adjusts the sparks density of Height gear 10*
Factory mode is for engineer only. When in Factory mode machine can't controlled by DMX console/host controller Press ENTER in this interface, all parameter of machine restore to default value.
Motor protect function, default setting is Off
Select input power supply voltage. Default setting for BT01 is 220VAC. BT02 is 110VAC.

*For better performance of SPARKULAR, please don't change the default value of density without permission from SHOWVEN.

6

6) DMX Channel Mode: The system occupies two channels.

First Channel 0-15 16-39 40-63 64-87 88-111 112-135 136-159 160-183 184-207 208-231 232-255 Second Channel 60-80 20-40 0-10 240-255

Function Fountain Off Fountain Height 1 Fountain Height 2 Fountain Height 3 Fountain Height 4 Fountain Height 5 Fountain Height 6 Fountain Height 7 Fountain Height 8 Fountain Height 9 Fountain Height 10 Function Clear Material EMERGENCY STOP Pre-heat Off Pre-heat On

7

2.Host Controller

1) Description
1. ZK6200/ZK6300 Host Controller is an intelligent system specially designed for the multi-effects and remote control of Sparkular series machine, so as to create the simulation and demonstration of sparks effects. The audio trigger and timing code trigger can be used to control the synchronous with music. LAN ports can be used to extend the communication among multi host controllers.

Model Dimension Weight Input Work Power Work Temp. Ports
Support max. Battery Lifetime

ZK6200 390 x 300 x 110mm 3.5kg AC 110V-240V, 50/60Hz 15W -10¥~50¥ 2 CAN communication ports, 1 USB port, 2 media ports(trigger by music), 2 MIDI ports(trigger by music), 2 DMX512 output ports, Ethernet. 200m communication cable 3350mAH >3 years

2) Host Controller Introduction ­ Standard or Pro Version
a) Standard DMX512 signal output b) Support 18 units Sparkular at the same time (ZK6300 54 units). c) Five standard dynamic effect modes: Synchronization, Center to Ends, Ends to Center, Left to right, Right To Left,
Special Effects and one user-definable special effect mode (together with SPARKULAREdit 200 software from SHOWVEN), supports 8 files and each file supports 36000 lines at maximum (special effects last for 30 minutes) d) There are multiple optional trigger sources. Hand, Music or Midi Inputs. e) Support simulation function and LED display. f) Monitoring function: Host controller with RDMX function, can feedback status information such as Temp., error message etc. of each machine. g) Emergency stop function: Pause or Stop Button.

8

3) Controller Operation Panel
a) Cable Connection Area:
AC Input: AC Power Input. CAN: CAN Communication Input/Output Ports. Tape In: Audio Signal Input Port of Main Channel Aux: Audio Signal Socket of Side Channel. Music: Displaying the Electrical Level of Audio Signal. MIDI In: Time Synchronous Signal Input of MIDI thru output. DMX 512: DMX Signal port LAN: Network's Cascade Socket among Multi-Chassis, so as to link the remote control feature. Download: SparkularEdit200 software Port
b) Manual Operation Area
No.1 to No.18 is Sparkular number. Firing / Stop of each unit of Sparkular by press related key of 1 to18. The Sparkular can be operated after the Pre-Heat warm up for 5 minutes. The indicator light will switch from flash green to always-on when heating up was ready. When firing is activated the indicator light will change to Red. Press "FIRING" to shoot/stop the SPARKULAR machine.
c) Mode Selection Area
There are five standard dynamic modes and one special effects mode which can be initiated by pressing the keys. These activate a pre-programmed page of functions that are displayed on each selection.
9

d) LCD Area
F1: Main Menu F2: File Selection Menu F3: Configuration Menu F4: About Menu
e) Edit/Control Area
Parameters can be programmed through number keys or up/down keys. Test: For test/demonstration of edit effects. When press the Test, Sparkular file will be operated and LED will display the
effect, but communication won't be output. This is also for factory testing. Pause: Device can be forced to stop once any abnormality happens. Pre-heat also shuts off. Forward: Under the special effect mode, the operating time can be put forward. Rewind: Under the special effect mode, the operating time can be put backward. Clear Material: Clear material of SPARKULAR before and after each show, to clean the remaining consumable in the
heating chamber, avoid blocking of the SPARKULAR. Pre-heat: Press "Pre-heat" to heating up the SPARKULAR. It takes around 5min. For long time not use the machine,
suggest to turn off the "Pre-heat" function and allow SPARKULAR to return to normal temperature. Firing: Activate/stop SPARKULAR programming. Left and right keys can make the cursor move on the different parameters. Parameters can be edited through up/down keys and number keys and it will be saved automatically. The confirm key can also be initiated to save.
4) Interface
a)Main Menu
MODE: Effect Mode GROUP: Total Quantity of Devices. Battery logo shows battery capacity and when it decrease to one grid, please charge it.
10

Option FILE NO. FIRING HEIGHT FIRING DURATION TRIGER DELAY REPEAT PERIOD REPEAT COUNTS

Scope 1-8 1-10 0.1-30.0s 0.1-30.0s 0.1-50.0s 1-5

Illustration File number Fountain Height gear. "." button can change height10 directly. Duration of the Fountain Trigger delay between two machines Time to start of next sequence/period Repeated times

Note: Only "Pause or Stop, Forward", "Rewind" button are available when "Firing" button lighting. Please note the setting for "repeat counts"to avoid mutli repeat of effects. Monitor: The working status of SPARKULAR will show on the LCD screen of host controller. Normal ly it shows the core temperature of SPARKULAR, when there are error information it will also show in this area.

b) Error Information Please refer to the error information of the machine.

c) File Select: F2 F2 displays the parameters list of 8 preset files.

d) Configuration MenuF3

11

Option

Range

Description

SPARKULAR Start No. 1-18

Select range

SPARKULAR End No. 1-18

Select range

Trigger Source

HAND,AUDIO,MIDI Trigger Sources options under special effect mode

Audio Level Audio Filter Delay Mode Selection LANGUAGE

1,2,3,4
10-100ms User Mode Factory Mode ENGLISH/CHINESE

REPEAT TIME MODE

Repeat period Repeat Delay

DMX IN
DMX Address LAN

On/Off 1-512

Voltage classes1-4 after choosing Audio Trigger Mode
Time toThe filtering time of trigger signals after choosing Audio Trigger Mode start of next sequence/period
Factory Mode only used for the factory test
Language switch
Repeat period: Cycle timing start when first machines start to work. (chasing effects can realize with this mode) Repeat delay: Cycle timing start when the first firing cycle terminate On: DMX in activated, when there is DMX in signal, host controller will be locked, and DMX signal will transfer to SPARKULAR. OFF: DMX in disabled. When use DMX IN function of Host controller, the DMX address of host controller.
Reserve for future use. Default value is OFF.

5) The Use of the Special Effect Mode:
Special effects are edit on SparkularEdit200 software with computer, effects file can download to host controller with USB cable. For more information please refer to SparkularEdit200 manual. Trigger Source HAND: When Trigger Source select HAND, press Firing to activate programming. AUDIO: Audio Trigger interfered easily, and it can be triggered only one time, it activated when audio signal appears. There are audio signal light on the Music window, and Audio Level 1-4 corresponding to bottom to top. When Audio Level is 1 and Audio Filter Delay is 50ms, when audio signal appear, first light of Music is on and lasts for 50ms, and the file was activated. In order to prevent the mistake trigger, before use AUDIO trigger function, please set Trigger Source at HAND, connect audio signal to normal audio signal source, and select AUDIO. According to the level of audio signal select proper Audio Level, Audio Filter Delay. MIDI: When Trigger Source is set as MIDI, the operation of the device can be started and stopped synchronously by MIDI Time Code (MTC).
No matter which mode the Trigger Source selected, the operation of the device can be started and stopped synchronously by SparkularEdit200 connected computer.

12

3. System Configuration and Connection
1) System Configuration
Host Controller

Standard DMX Communication Cable

1 AC Input

2

3

2) System Connection
a) Controller and Sparkular

4 Sparkular

Standard DMX Communication Cable

3PIN Power Supply Cable

5

6

Host Controller (ZK6200)

DMX Communication Cable

Sparkular

b) Sparkular Power Supply Cable
Maximum of 6 units (BT01) / 3 units (BT02) Sparkular in series with one main power supply cable.

Sparkular

Power Supply Cable

c) Power Link Cable Connection between Sparkular

13

Sparkular

Power Link Cable

Sparkular

d) Communication Cable Connection between Sparkular

Sparkular

DMX Communication Cable

Sparkular

4. System Prepare and Start

1) Fill the Sparkular consumable HC8200 to Sparkular
Please fill in Sparkular Granules HC8200 into the hopper. Maximum volume for the hopper is 200g. There are three types of HC8200 for SPARKULAR.

Model

HC8200 SMALL

HC8200 MEDIUM

HC8200 LARGE

Effect height

1.5-3m

1.5-3.5m

2-5m

a) Open HC8200 pouch

SMALL
b) Fill SPARKULAR hopper

MEDIUM

LARGE

Open the hopper lid

Funnel and Nozzel plug (not standard configuration, can order from SHOWVEN)

Filling the hopper

Close the lid of hopper

Warning: Please fill SPARKULAR by following above process. After adding the consumable, please do remember to close the lid.

14

2) Turn On Host Controller
Switch on host controller as below.
3) Turn On Sparkular
Switch on Sparkular,
4) Parameters setup
Programming SPARKULAR effects according to this manual.
5) Activate Sparkular machine
Swip an RFID card after filling each bag of HC8200. Read the card as show below. SPARKULAR shows time remain if read successfully. SPARKULAR report E4 when remaining time is less than 10 minutes.
6) Firing
Activate programming effects by press "FIRING" on the host controller.
7) Turn Off
After show, please power off Sparkular and host controller. Allow SPARKULAR to cool down before packing. Never touch the nozzle of SPARKULAR. DANGER OF BURN!
15

8) Clear Material
Please running Clear Material both before and after each show. Before delivery or not use machine in a long time, please pouring the HC8200 out of hopper, and store the remaining HC8200 in a dry sealed bottle for next time use.

Tools

To empty Granular material

Warning: Please follow this process to clear material when necessary.

16

Warranty Instructions
·Sincere thanks for your choosing SPARKULAR, you will receive quality service from us. ·The product warranty period is one year. If there are any quality problems within 7 days after ship
ping out from our factory, we can exchange a brand new same model machine for you. ·We will offer free of charge maintenance service for machines which with hardware malfunction
(except for the instrument damage caused by human factors)in warranty period. Please don't repair machine without factory permission.

®Below situations NOT included in warranty service: 1. Damage caused by improper transportation, usage, management, and maintenance, or damage
caused by human factors; 2. Disassemble, modify or repair products without Showven's permission; 3. Damage caused by external reasons (lightning strike, power supply etc); 4. Damage caused by improper installation or use; For product damage not included in warranty range, we can provide paid service. ®Invoice and warranty card are necessary when applying for maintenance service from SHOWVEN.
Warranty Card

Product Name: Purchase Date:
Tel:
Address:
Problem Feedback
Actual Problem: Maintenance Detail: Service Engineer:

Serial No. Service Date:

17

Showven Technologies Co., Ltd
Add: Building B1, Changsha E Center No.18, Xiangtai Road, Liuyang Economic Development Zone, Changsha City, 410300, Hunan Province, P.R.China. Tel: +86-731-83833068 Web: www.showven.cn E-mail: info@showven.cn



References

Adobe Illustrator CC (Windows) 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)