Instruction Manual for pdq models including: 6300D Dummy Device, 6300D, Dummy Device
PDQ 6300/6400 Exit Device ation
File Info : application/pdf, 1 Pages, 462.54KB
DocumentDocument6300D EXIT INSTALLATION INSTRUCTION DUMMY DEVICE Phone: 833-2-PDQTEC | www.pdqlocks.com 40" To Finished Floor 1. PREPARE DOOR Prepare door and frame according to template. 2. SIZE DEVICE Standard lengths are for 36" or 48" door. Device must be cut for other lengths. Mark length with tape length equals device size minus desired door size (for 30" door = cut 6" off 36" device) ensuring a square cut. Maximum cut off length: With Without Dogging Dogging 36" Device 6" 8" 48" Device 12" 14" 3. INSTALL DEVICE Install device with 2 screws. Device can be surface mounted to the door, optional sex nuts are available. Mounting Options: Reinforced Steel or Aluminum Door Surface Mount: Drill/Tap push side for 1/4-20 Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood Screw All Others Use optional Sex Bolts. Drill push side with 9/32" drill bit. Drill pull side with 3/8" drill bit. 4. INSTALL END CAP Slide end cap into rail. Ensure rail is level. Mark the centers of the slots. Remove end cap then drill holes using the chart from Step 3. Reinstall end cap and fasten with screws. 1 639410 Rev0 3/10/22