Instruction Manual for pdq models including: 6300D Dummy Device, 6300D, Dummy Device

Visio-639410 R0 - 6300 Dummy Instruction.vsdx

Tim.White

PDQ 6300D Installation Instructions

PDQ 6300/6400 Exit Device ation


File Info : application/pdf, 1 Pages, 462.54KB

PDF preview unavailable. Download the PDF instead.

6300D - Dummy Device Installation Instruction
6300D EXIT INSTALLATION INSTRUCTION
DUMMY DEVICE

Phone: 833-2-PDQTEC | www.pdqlocks.com

40" To Finished Floor

1. PREPARE DOOR
 Prepare door and frame according to
template.

2. SIZE DEVICE
 Standard lengths are for 36" or 48" door. Device must be cut for other lengths.
 Mark length with tape ­ length equals device size minus desired door size (for 30" door = cut 6" off 36" device) ensuring a square cut.

Maximum cut off length:

With Without

Dogging Dogging

36" Device 6"

8"

48" Device 12"

14"

3. INSTALL DEVICE
 Install device with 2 screws.
 Device can be surface mounted to the door, optional sex nuts are available.

Mounting Options:

Reinforced Steel or Aluminum Door

Surface

Mount:

Drill/Tap

push

side for

1/4-20

Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood Screw

All Others

Use optional Sex Bolts. Drill push side with

9/32" drill bit. Drill pull side with 3/8" drill bit.

4. INSTALL END CAP
 Slide end cap into rail. Ensure rail is level. Mark the centers of the slots.
 Remove end cap then drill holes using the chart from Step 3.
 Reinstall end cap and fasten with screws.
1

639410 Rev0 ­ 3/10/22

