Platinum-Electric-Low-Clearance-Ceiling-Recess-Instructions-EN
Version 2.2 AU/UK/US
WARNING
Joists, beams and rafters shall not be cut or notched to install the heater.

PLATINUM SMART-HEATTM ELECTRIC HEATERS BY BROMIC
LOW CLEARANCE (LC) CEILING RECESS INSTALLATION INSTRUCTIONS
FOR MODELS 3400W & 2300W

WARNING
Instructions below are suitable for ceiling surfaces 1030mm (0.39"-1.2") thick. For ceiling surfaces thicker than 30mm (1.2"), contact Bromic for alternative installation options.
WARNING
The heater shall, under no circumstance, be covered with insulating material or similar material.
WARNING
It is important that regular maintenance is carried out on the heater to maintain appearance. Inspect and clean more frequently in adverse conditions such as coastal environments.

WARNING
This heater MUST be permanently installed by an authorised/licenced person. Do not perform maintenance, or carry out installation or assembly procedure while electrical power is switched on. Wait 2 hours after switching off the heater before handling.

WARNING
In ceiling recess installation, the heater must be completely protected against water contact from above.

1x M6x10

8x M3x6

8x M4x8

1x

IP COVER

CEILING RECESS

1x

BOX

VENT COVER

2x

BLACK

HARDWARE

VENT COVER

4x

TRIMS

TRIM ASSEMBLY
(STANDARD) 1x
OR

TERMINAL BOX
1x

VENT COVER

2x

WHITE

1x

1000mm (39.3") - 3400W 800mm (31.5") - 2300W

N2 WAGO CONNECTOR

TRIM ASSEMBLY (MARINE)
1x
8mm (5/16") 20mm ( 13/16")

HEATER NOT INCLUDED

2 PERSON INSTALLATION
bromic.com

TOOLS REQUIRED
IMPORTANT
READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION
ABOUT THIS MANUAL. KEEP INSTRUCTIONS WITH APPLIANCE FOR FUTURE REFERENCE.
1

This manual contains important information about the installation, operation, and maintenance of the Low Clearance Ceiling Recess Kit for the Platinum Smart-Heat
Electric Heaters. Please pay close attention to the important safety informaiton shown throughout this instruction manual.
Any safety information will be accompanied by the following safety alert symbols:
DANGER, WARNING, IMPORTANT
· Read this manual carefully before installing or servicing this product.
· Imporper installation, operation, or maintenance can result in death, severe injury, or property damage.
· This appliance is intended for fixed installation with voltage as specified on the power rating label.
· Installation MUST be carried out by a licensed and authorised technician in accordance with local electrical codes.
· The Platinum Smart-HeatTM Electric Heater is intended for domestic and commercial use, unless otherwise specified.
· The marine grade versions of the LC Ceiling Recess Kit shall be installed for land and coastal environment application ONLY.
· The IPX5 marine grade version of the LC Ceiling Recess Kit shall NOT be installed on marine craft.

SAVE THESE INSTRUCTIONS

SPECIFICATIONS

Model

Part No.

US/EU AU

Total Ouput - Kit + Heater
Power connection required (volts/amps)

LC Ceiling Recess Kit

BH3623009 2623009

BH3623008 2623008

2300W

3400W

208V - A.C 60HZ - 11.1A

220-240 - A.C -
50/60Hz - 9.6A

208V - A.C 60Hz - 16.3A

220-240 - A.C. 50/60Hz - 14.2A

LC Ceiling Recess Kit Marine

BH3623011 2623011

BH3623010 2623010

2300W

3400W

208V - A.C 60HZ - 11.1A

220-240 - A.C. 50/60Hz - 9.6A

208V - A.C 60Hz - 16.3A

220-240 - A.C. 50/60Hz - 14.2A

Overall Dimensions (L x W x H)
Weight
Finish

1039 x 261 x 175 mm (40.9 x 10.3 x 6.9 ")
11kg (24.3lb)

1475 x 261 x 175 mm (40.9 x 10.3 x 6.9 ")
14kg (31lb)

Brushed Stainless Steel 304

1039 x 261 x 175 mm (40.9 x 10.3 x 6.9 ")
11kg (24.3lb)

1475 x 261 x 175 mm (40.9 x 10.3 x 6.9 ")
14kg (31lb)

Brushed Stainless Steel 316

Approval

ETL: Intertek 5001799, CB/CE-LVD: Intertek 200802166SHA-001/002, SAA: Intertek 200802166SHA-001 PATENT PENDING

Head Office: 10 Phiney Place, Ingleburn, NSW 2565 Australia Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas) Fax: +61 2 9748 4289
Email: info@bromic.com Web: www.bromic.com Note: Bromic Pty Ltd reserves the right to make changes to specifications, parts, components and equipment without prior notification.
This installation, operation and service manual may not be reproduced in any form without prior written consent from Bromic Pty Ltd.

bromic.com

2

ISOMETRIC VIEW DEPICTING LOW CLEARANCE RECESS KIT INSTALLATION SETUP OPTIONS
The example depicts the recess kit fixed on the length sides only. The installer is responsible for ensuring product is installed in a structurally sound configuration.

CEILING JOIST
CEILING CUTOUT & CLEARANCE ZONES

MINIMUM 240mm (9.4") GAP BETWEEN JOISTS
CLEARANCE ZONE

Minimum - 180mm (7.1") (From glass surface)

200mm (7.9")

995mm (39.2") - [2300W] 1430 (56.3") - [3400W]

TERMINAL BOX END CLEARANCE

CEILING CUTOUT LENGTH

ROOM CLEARANCE AND OVERALL DIMENSIONS

SIDE VIEW

CEILING

1039mm (40.9") - [2300W] 1475 (58.1") - [3400W]

500mm

TRIM LENGTH

(19.7")

MINIMUM WALL

CLEARANCE FROM TRIM

238mm (9.4") CUTOUT WIDTH
FRONT VIEW

175mm (6.9") MAX
PRODUCT HEIGHT

500mm (19.7") MINIMUM WALL CLEARANCE FROM TRIM

261mm (10.3") TRIM WIDTH

2400mm (94") ABOVE FINISH FLOOR (AFF)
MINIMUM CLEARANCE

2400mm (94") ABOVE FINISH FLOOR (AFF)
MINIMUM CLEARANCE

FLOOR

FLOOR

WARNING
Minimum vertical ceiling space clearance between the ceiling recess box and ceiling surface must be 180mm (7.1").
Minimum clearance measured from the terminal box end to the nearest surface must be 200mm (7.9").
Minimum clearance from the ceiling cutout and the nearest wall must be 500mm (19.7").
Minimum distance between heaters measured from edge of ceiling cut out must be 500mm (19.7").
Minimum distance between the heater surface and finished floor is 2400mm (94").

Standard Versions
Ensure that the heating unit is not directly exposed to rain or water contact. For the longest product life and to maintain product appearance, mount the heater under cover and protect from rain and weather.
Marine Versions
In a salt-air environment, such as near an ocean, corrosion occurs more quickly than normal. Stainless 316 has been used in the Marine configuration. Salt spray should be cleaned from the heater and recess kit immediately - while the heater and recess kit should undergo cleaning fortnightly to ensure maximum longevity. Use a qualified technician to check yearly for corroded areas and remove from service when heater safety is compromised.

bromic.com

3

INSTRUCTIONS START HERE
1. Prepare ceiling cut-out with the dimensions :
3400W - 1430mm x 240mm (56.3" X 9.45") 2300W - 1000mm x 240mm (39.4" X 9.45")
Heater must be installed with heater surface at least 2400mm (94") above the finished floor (AFF), with minimum clearance measured from the terminal box end to the nearest surface being 200mm (7.9"). Minimum heater to heater distance measured from edge of heater must be 500mm (19.7"). Refer to the install dimensions on page 3.
2. Fasten the ceiling recess box into c eiling with 6x (minimum) appropriate fasteners (not supplied) along the long edge.
NOTE: The fastening screws must be inserted into a strong material that can easily support the weight of the assembly. Your installation may require re-enforcing before the frame can be safely installed.
IMPORTANT It is the installers responsibility to ensure that the installation site is structurally suitable for the mass of the heater installation being 18.5kg (41 lb) [2300W] or 24kg (53 lb) [3400W].
MINIMUM 12 FASTENERS TO BE USED FOR TIMBER MEMBERS.
3. Assemble 2x vent covers together using the vent cover trims and 4x M3x6mm screws. The colour of the vent covers are to match the heater.

2330400W0W -

1-0104030mmmm(3(95.64."3)")

20mm (13/16")

(9.45") 240mm

4. Install the assembled vent covers to the end of trim assembly using 4x M4x8mm screws.

5. Remove the 2x M6x14mm and 2x M4x8mm screws on the rear bracket of the heater. Remove the swivel bracket on the heater rear. Loosen the M16 cable gland using a 20mm (13/16") spanner and install the removed cable gland onto the IP cover.
ENSURE THE CABLE GLAND NUT IS REINSTALLED ON THE INNER SURFACE OF THE IP COVER.
NOTE: During this process the strain relief device has been removed - Care must be taken to not apply significant load to the cable as this could stress the internal cable crimps and permanently damage the heater.

bromic.com

4

CEILING RECESS INSTALLATION INSTRUCTIONS CONTINUED ...

6. Carefully remove the 4x M5x10mm screws at the rear of the heater and align the heater trim assembly with the mounting holes.
The cable is fed through the opening in the centre of the trim assembly.

20mm (13/16")

NOTE: REAR HEATER BRACKET IS NOT TO BE REMOVED.

7. Re-install the 4x M5x10mm screws to attach the heater to the trim assembly.
8. Feed the heater cable through the IP cover and cable gland . Attach the IP bracket to the heater using the M6x10mm screw. When in location, ensure the M16 cable gland is fastened using a 20mm (13/16") spanner.

bromic.com

5

9. Remove the lid of the terminal box by removing the 4x M4x8mm screws and set aside for reassembly.
10. Cut down the heater cable no shorter than 1000mm (39.3") for the 3400W unit, or 800mm (31.5") for the 2300W unit measured from the cable gland.

1000mm (39.3") - 3400W 800mm (31.5") - 2300W

11. Feed the heater cable through the lower M16 cable gland located on the terminal box. Ensure a that the cable gland is tightened.

12. Feed the mains (and control cables if applicable) through the terminal box cut-out in the heater box.
Refer to the wiring diagram diagrams on the next page

For installs using a Bromic Dimmer (sold separately) OR On/Off Controller (sold separately), please refer to the electrical diagram on page 11.

For installs using a manual wall switch (not supplied), please refer to the electrical diagram on page 12.

Comprehensive electrical diagrams can be found on page 14.

bromic.com

6

CEILING RECESS INSTALLATION INSTRUCTIONS CONTINUED ...
13.Once all connections have been made, use the supplied 4x M4x8mm screws to close the terminal box.
MIN 2 PEOPLE REQUIRED FOR FOLLOWING STEPS.
MAX SAFE LIFTING 16 kg (26.5 lbs) PER PERSON.
14. Bring the heater and terminal box up onto stable work platform closer to the terminal box cut-out end.
IMPORTANT ENSURE THE FRONT GLASS OF THE HEATER IS PROTECTED BEFORE PLACING ON TOP.
14. Before installing the terminal box - retrieve the thermal cut-off switch cable. Plug it into thermal cut-off switch receptacle at the rear of the terminal box.
WARNING Heater will not function unless the thermal cut-off switch plug is inserted into receptacle on rear of terminal box.
15. Fasten the terminal box into the ceiling recess box using 4x M4x8mm screws.

bromic.com

7

CEILING RECESS INSTALLATION INSTRUCTIONS CONTINUED ...

16. Attach the trim assembly to the ceiling recess box by hooking on one side of the mounting tab features to 2x M5x12mm hex flange bolts.
Ensure heater cable placement is on the inside of the mounting hooks.
Mounting tab feature
IMPORTANT Ensure heater cable placement is on the inside of the mounting hooks.

8mm (5/16")

17. Rotate the trim assembly and attach the other side of the mounting tabs to the other 2x M5x12mm hex flange bolts.

WARNING
The heater supply cable MUST completely rest on the support structure. The supply cable MUST NOT be touching the rear surface of the heater.
18. Raise up the heater trim assembly so it is flush with the ceiling. Tighten the 4x M5x12mm hex flange bolts using a 8mm (5/16") spanner to secure the heater in place. Check heater alignment is flush with the ceiling before tightening the screws.
bromic.com

4x
8

ELECTRICAL INSTALLATION

1. Check product label for correct voltage and

WARNING

wattage to ensure sure power source conforms to the heaters requirements.

This heater MUST be permanently installed by an authorised/ licenced person. Do not perform maintenance, or carry out

2. The power cable must positioned away from & protected from the enclosure of the heater.
3. Make all connections in accordance with local

installation or assembly procedure while electrical power is switched on. To disconnect heater, turn off power to heater circuit at main disconnect panel .

electrical code regulations. For outdoor installation,

WARNING

all connections must be made in accordance with

local electrical code regulations for outdoor wiring.

ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from electrical supply before installing or

Only use wiring components approved for outdoor servicing this heater. Read and follow installation clearance

use with minimum IPX5 rating.

requirements outlined in this manual. The appliance MUST be connected to a properly grounded electrical source.

For wiring instructions using Bromic Platinum Smart-Heat Electric Wireless Dimmer BH3130011-1 or ON/OFF Control BH3130010-1 refer to instructions provided with controller.

IMPORTANT: Electronic dimmer controls generate heat during operation. For Bromic heaters installed Bromic SmartHeat Electric Wireless Dimmer BH3130011-1 or ON/OFF Control BH3130010-1 it is essential to ensure dimmers are mounted in a clean, dry and well ventilated position with clearance on all sides. It must be ensured the dimmers are not installed in a confined space, close to other heat generating appliances or in the case of a multi-dimmer installation, not too close together. Dimmers must remain cool at all times. Please consult Bromic dimmer installation instructions for further details or for further questions please contact Bromic technical support services.

SERVICING

WARNING
ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from electrical supply before servicing this heater.
WARNING
Servicing and maitenance MUST be carried out by an authorised and licenced service person only. Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
WARNING
If the supply cord is damaged, it must be replaced by Bromic, a service agent of Bromic or similarly qualified persons in order to avoid a hazard. Contact Bromic for further information on replacement of the supply cord.
TROUBLESHOOTING

MAINTENANCE
Ensure that the heating unit is not directly exposed to rain or water contact. For longest product life, and to maintain product appearance, mount heater under cover and protect from rain and weather whenever possible.
The exterior housing of the heater should be cleaned fortnightly. To clean the appliance; ensure heater is off, and has been off for at least 2 hours after operation, before wiping off any dirt/dust with a soft damp cloth.
Salt in the air can cause rusting of metal, especially in coastal environment. Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product's appearance.

SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION

No heat Not enough heat Too much heat

1. Improper Connection 2. Self resetting thermal switch not plugged in 3. Non-self resetting thermal switch has triggered.
1. Heater too small for application 2. Heater mounted too high or too far 3. Incorrect voltage connected to heater.
1. Heater too large for application 2. Heater mounted too low or too close 3. Incorrect voltage connected to heater

1. Check connection to power supply 2. Check self resetting thermal switch is plugged in (see step 14). 3. Reset Non-self resetting thermal switch located inside terminal box (see electrical diagram).
1. Add additional heater(s) 2. Decrease mounting height or distance. 3. Check correct supply voltage and current is provided
1. Replace with smaller heater 2. Increase mounting height or distance 3. Check correct supply voltage is provided.

Non-self resetting thermal switch
In the event that the temperatures exceed safe operating limits, the non-self resetting thermal switch will trigger. This may be due to the fan being damaged or the heater is operating at a high ambient temperature. To reset the switch, push down on the reset button at the middle of the switch. THE LOCATION IS SHOWN ON PAGE 10,
bromic.com

WARNING
Ensure circuit is not live before attempting to
reset the safety switch.
9

QUICK GUIDE FOR ACCESSING TERMINAL BOX

1

2

3

4x
4

5
Non-self resetting thermal switch

Relay Transformer

REFER TO WIRING DIAGRAMS ON PAGE 14. IF THE PRODUCT IS STILL NOT WORKING CONTACT BROMIC FOR ADDITIONAL TECHNICAL SUPPORT.

bromic.com

10

WIRING DIAGRAM FOR LOW CLEARANCE CEILING RECESS KIT (FOR USE WITH DIMMER OR ON/OFF)
BELOW IS A SIMPLIFIED DIAGRAM OF THE TERMINAL BOX. ALL CONNECTIONS ADJUSTED BY THE INSTALLER ARE DISPLAYED. ITEMS NOT DISPLAYED SHALL NOT BE MODIFIED.
HEATER CABLE

Non-self resetting thermal switch
TOP VIEW OF TERMINAL BOX
WARNING
AC Single Phase Heater must be permanently
installed and hard wired by an authorised/licensed
person. This product is designed for use
with both 220-240V & 208V Platinum Electric Heaters.

S2

N2
S1

L
N

To Dimmer Power (Load) Output OR ON/OFF Power (Load) Output

WIRES DENOTED BY DASHED LINES ARE

To Dimmer Power Supply Input OR ON/OFF Power Supply Input
SUPPLY

SUPPLIED BY

THE INSTALLER.

BROWN LIVE/ACTIVE

BLUE NEUTRAL

GREEN/YELLOW EARTH

OR HOT LEG 1

HOT LEG 2

OR

PHASE A

PHASE B

OR

PHASE B

PHASE C

NOTES:

OR

PHASE C

PHASE A

· For wiring instructions using Bromic SmartHeat Electric Wireless Dimmer BH3130011-1 or

ON/OFF Controller BH3130010-1 refer to the instructions provided with the controller.

· Connecting to a 3-phase power system can only be done for 208V versions of the

Platinum Electric Heater.

bromic.com

11

WIRING DIAGRAM FOR LOW CLEARANCE CEILING RECESS KIT (FOR USE WITH WALL SWITCH)

BELOW IS A SIMPLIFIED DIAGRAM OF THE TERMINAL BOX. ALL CONNECTIONS ADJUSTED BY THE INSTALLER ARE DISPLAYED. ITEMS NOT DISPLAYED SHALL NOT BE MODIFIED.

HEATER CABLE

Non-self resetting thermal switch
TOP VIEW OF TERMINAL BOX
WARNING
AC Single Phase Heater must be permanently installed and hard wired by an authorised/licensed
person. This product is designed for use
with both 220-240V & 208V Platinum Electric Heaters.

S2

S1

L

N

WALL SWITCH SUPPLIED BY CUSTOMER

WIRES DENOTED

BY DASHED

LINES ARE SUPPLIED BY THE INSTALLER.

BROWN

LIVE/ACTIVE

OR HOT LEG 1

OR

PHASE A

OR

PHASE B

OR

PHASE C

BLUE NEUTRAL HOT LEG 2 PHASE B PHASE C PHASE A

GREEN/YELLOW EARTH

NOTES: · The ceiling recess kit is designed for the Platinum Electric SII 2300W & 3400W units only.

· Connecting to a 3-phase power system can only be done for 208V versions of the Platinum

Electric Heater.

bromic.com

12

WIRING DIAGRAM FOR LOW CLEARANCE CEILING RECESS KIT (FOR USE WITH 2 HEATERS ON/OFF OR DIMMER)
BELOW IS A SIMPLIFIED DIAGRAM OF THE TERMINAL BOX. ALL CONNECTIONS ADJUSTED BY THE INSTALLER ARE DISPLAYED. ITEMS NOT DISPLAYED SHALL NOT BE MODIFIED.

HEATER CABLE 1

HEATER CABLE 2

S2

N2
S1

L N

Output 1 ON/OFF Power (Load)

WIRES DENOTED BY DASHED LINES ARE SUPPLIED
BY THE INSTALLER.

S2

N2
S1

L N

Output 2 ON/OFF Power (Load)

Input ON/OFF Power Supply

JUNCTION BOX*

WARNING
AC Single Phase Heater must be permanently installed and hard wired by an authorised/licensed
person.

SUPPLY

This product is designed for use with both 220-240V & 208V Platinum Electric Heaters.

BROWN LIVE/ACTIVE OR HOT LEG 1 OR PHASE A OR PHASE B OR PHASE C

BLUE NEUTRAL HOT LEG 2 PHASE B PHASE C PHASE A

GREEN/ YELLOW EARTH

NOTES:

· For wiring instructions using Bromic SmartHeat Electric Wireless Dimmer BH3130011-1 or

ON/OFF Controller BH3130010-1 refer to the instructions provided with the controller.

· Connecting to a 3-phase power system can only be done for 208V versions of the

Platinum Electric Heater.

· *The junction box and connections inside must be suitable for the voltage and current

capacity of the heaters being installed.

bromic.com

13

ELECTRICAL DIAGRAM - FOR ON/OFF OR DIMMER

RELAY
(NO) L

Non-Self Resetting Thermal Switch (NC)
Self Resseting Thermal Switch
(NO)
+12V
240VAC/12VDC TRANSFORMER
L

-12V +12V
M
12V FAN
-12V
L

ON/OFF OR DIMMER

INPUT

OUTPUT

L N E E E N N L L S1

S2

12 34 5 6789

N2 N

L

HEATER

EARTH

N EARTH

L
AC SUPPLY 208V OR 220-240V

N EARTH

ELECTRICAL DIAGRAM - FOR WALL SWITCH

TERMINAL BOX GROUNDING POINT

RELAY
(NO) L

Non-Self Resetting Thermal Switch (NC)
Self Resseting Thermal Switch
(NO)
+12V
240VAC/12VDC TRANSFORMER
L

-12V +12V
M
12V FAN
-12V

S1

S2

L
WALL SWITCH (SUPPLIED BY CUSTOMER
L

N

HEATER

EARTH

L

N

L

N

AC SUPPLY 208V OR 220-240V

EARTH

bromic.com

EARTH
TERMINAL BOX GROUNDING POINT
14

