MPE Report

Report No.: STS2505072H02

Issued For

GODOX PHOTO EQUIPMENT CO.,LTD

1st to 4th Floor, Building 2/1st to 4th Floor, Building 4, Yaochuan Industrial Zone, Tangwei Community, Fuhai Street, Baoan District, Shenzhen, 518103 China

Product Information

Product Name: iFlash Camera Flash

Brand Name: Godox

Model Name: iT30Pro S

Series Model(s): iT30Pro N, iT30Pro O, iT30Pro F, iT30Pro C

FCC ID: 2ABYN148

Test Standards: FCC 47CFR §2.1093, 447498 D04 Interim General RF Exposure Guidance v01

Test Summary

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd.

Date of Receipt of Test Item: 13 May 2025

Date(s) of Performance of Tests: 13 May 2025 - 27 May 2025

Date of Issue: 27 May 2025

Test Result: Pass

Test Personnel

Testing Engineer: Aaron Bu

Technical Manager: Skylar Li

Authorized Signatory: Bovey Yang

General Information

General Description of the EUT

Product NameiFlash Camera Flash
Brand NameGodox
Model NameiT30Pro S
Series Model(s)iT30Pro N, iT30Pro O, iT30Pro F, iT30Pro C
Model DifferenceThe bottom hot shoe is different
Product DescriptionThe EUT is iFlash Camera Flash
Operation Frequency2412.99MHz - 2464.49MHz
Modulation TypeMSK
Antenna Gain5.46dBi
Antenna DesignationChip
Power RatingInput: DC5V 2A
AdapterN/A
BatteryLi-ion battery: 7.4V 900mAh
Hardware Version20241011E03
Software VersionV1.0

Test Factory

SHENZHEN STS TEST SERVICES CO., LTD

Address: 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao'an District, Shenzhen, Guang Dong, China

FCC test Firm Registration Number: 625569

IC test Firm Registration Number: 12108A

A2LA Certificate No.: 4338.01

FCC 47CFR §2.1093 REQUIREMENT

Test Standards

Follow the maximum permissible exposure (MPE) limits specified in 447498 D04 Interim General Radio Frequency Exposure Guidelines v01. The gain of the antenna used in the product was extracted from the supplied antenna data sheet and the maximum total power input to the antenna was also measured. Calculate the distance from the product to the MPE limit by the formula.

Limit

For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if:

(A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of Part 1.1307. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A);

(B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by:

Pth (mW) = (ERP20 cm (d/20 cm)2 for 0.5 cm ≤ d ≤ 20 cm)

Pth (mW) = (ERP20 cm for 20 cm < d ≤ 40 cm)

Where:

x = -log10(60 / ERP20 cm) and f is in GHz;

ERP20 cm (mW) = (2040f) for 0.3 GHz ≤ f < 1.5 GHz

ERP20 cm (mW) = (3060) for 1.5 GHz ≤ f ≤ 6 GHz

d = the separation distance (cm);

(C) Or using below table and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value).

RF Source frequency (MHz)Threshold ERP(watts)
0.3-1.341,920 R2.
1.34-303,450 R2/f2.
30-3003.83 R2.
300-1,5000.0128 R2f.
1,500-100,00019.2R2.

For multiple RF sources: Multiple RF sources are exempt if:

(A) The available maximum time-averaged power of each source is no more than 1 mW and there is a separation distance of two centimeters between any portion of a radiating structure operating and the nearest portion of any other radiating structure in the same device, except if the sum of multiple sources is less than 1 mW during the time-averaging period, in which case they may be treated as a single source (separation is not required). This exemption may not be used in conjunction with other exemption criteria other than those is paragraph (b)(3)(i)(A) of Part 1.1307. Medical implant devices may only use this exemption and that in paragraph (b)(3)(i)(A).

(B) In the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation.

Σai=1 (Pi / Pth,i) + Σbj=1 (ERPj / ERPth,j) + Σck=1 (Evaluatedk / Exposure Limitk) ≤ 1

Where:

a = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(B) of Part 1.1307 for Pth, including existing exempt transmitters and those being added.

b = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(C) of Part 1.1307 for Threshold ERP, including existing exempt transmitters and those being added.

c = number of existing fixed, mobile, or portable RF sources with known evaluation for the specified minimum distance including existing evaluated transmitters.

Pi = the available maximum time-averaged power or the ERP, whichever is greater, for fixed, mobile, or portable RF source i at a distance between 0.5 cm and 40 cm (inclusive).

Pth,i = the exemption threshold power (Pth) according to paragraph (b)(3)(i)(B) of this section for fixed, mobile, or portable RF source i.

ERPj = the ERP of fixed, mobile, or portable RF source j.

ERPth,j = exemption threshold ERP for fixed, mobile, or portable RF source j, at a distance of at least λ/2π according to the applicable formula of paragraph (b)(3)(i)(C) of Part 1.1307.

Evaluatedk = the maximum reported SAR or MPE of fixed, mobile, or portable RF source k either in the device or at the transmitter site from an existing evaluation at the location of exposure.

Exposure Limitk = either the general population/uncontrolled maximum permissible exposure (MPE) or specific absorption rate (SAR) limit for each fixed, mobile, or portable RF source k, as applicable from § 1.1310.

Test Result

Tune up

ModeDetectorPower (dBuV/m) @3mPower (dBm)Turn up Power
2.4GPK92.12-3.08-4±1dBm

Note: Power(dBm) = dBuV/m@3m -95.2

RF FunctionFrequency (GHz)Separation distance (cm)Tune Up Power (dBm)Tune Up Power (mW)Limit (mW)RatioResult
2.4G2.4379998780.5-30.5012.7550.182Pass

Note: 1. The Maximum power is less than the limit, complies with the exemption requirements.

Note: 2. ERP = EIRP - 2.15

※※※※※END OF THE REPORT※※※※※

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8450457 Microsoft Word 2013 Microsoft Word 2013

Related Documents

Preview Godox iT30Pro iFlash クリップオンフラッシュ取扱説明書
Godox iT30Pro iFlash クリップオンフラッシュの取扱説明書。製品の警告、機能、操作方法、技術仕様、保証情報などを解説します。
Preview Godox iT30Pro Flash Declaration of Conformity
Declaration of Conformity for the Godox iT30Pro camera flash, detailing hardware and software versions, operating frequencies, and compliance with EU directives and standards.
Preview Godox iT30Pro S Instruction Manual
Comprehensive instruction manual for the Godox iT30Pro S Camera Flash, detailing its features, operation, and safety precautions. Learn about TTL flash, 2.4G wireless, high-speed sync, and more.
Preview Godox iT30Pro S Instruction Manual
Comprehensive instruction manual for the Godox iT30Pro S iFlash Camera Flash, covering setup, features, operation, and safety precautions.
Preview Godox iT30Pro iFlash Camera Flash Instruction Manual
Comprehensive instruction manual for the Godox iT30Pro iFlash Camera Flash, covering setup, operation, features like TTL auto flash, wireless control, and troubleshooting.
Preview Godox iFlash Camera Flash Declaration of Conformity
Declaration of Conformity for the Godox iFlash Camera Flash, listing product models, applicable EU directives and standards, test lab, and manufacturer information.
Preview Godox V100 Lithium Round TTL Flash Dome User Manual
This user manual provides detailed instructions for the Godox V100 Lithium Round TTL Flash Dome, covering its features, operation, settings, and troubleshooting. It includes information on master/slave modes, wireless flash, TTL and manual flash modes, and compatibility with various camera models.
Preview Godox iT22 iFlash Camera Flash: User Manual and Specifications
Comprehensive user manual and technical specifications for the Godox iT22 iFlash Camera Flash, covering safety instructions, operation, features, troubleshooting, and warranty information.