User Guide for Elimko models including: E-48P Series, E-48P Series Universal Advanced Digital Controllers, Universal Advanced Digital Controllers, Advanced Digital Controllers, Digital Controllers, Controllers
16 nov 2023 — 0. 1. * Only one of the analog output and RS-485 options can be coded. For example, only one of the options (X) and (Y) can be coded as 1.
File Info : application/pdf, 2 Pages, 1.54MB
DocumentDocumentKY-48P-1123-1 4. WARNINGS Thermocouple / miliVolt 0-20 mA / 4-20 mA Resistance Thermometer 2-Wire Transmitter Volt 200.0 200.0 R1 R2 E l i m k o SET 48P E-48P Series Universal Advanced Digital Controllers Quick Start Guide Manufacturer / Technical Support Elimko Elektronik malat ve Kontrol Ltd. ti. 8. Cadde 21. Sokak No:16 Emek 06510 Ankara / TÜRKYE Telefon: + 90 312 212 64 50 Faks: + 90 312 212 41 43 www.elimko.com.tr · e-mail:elimko@elimko.com.tr 1. DESCRIPTION E-48P Series universal process controllers are industrial devices at 48x48 mm IEC/TR 60668 dimensions designed using new generation microcontrollers with on/off, PID and other control forms, where inputs and outputs can be easily programmed by the user. In E-48P Series controllers, the set value and measured value can be displayed from -1999 to 9999 on two 4-digit displays; general purpose inputs (T/C, R/T, mV, mA) can be programmed. 2. DIMENSIONS and PANEL CUT-OUT 44 mm 44 mm 48 mm 200.0 200.0 R1 R2 E l i m k o SET 48P 48 mm Elimko Kontrol Edilmitir 2 TP : E48 SKALA : GR : ÇIKI : SER NO : 21/14798 Elimko Tel: +90 3122126450 Fax: +90 3122124143 TÜRKYE 44 mm 44 mm -0.0 45 x 45 mm +0.5 10 mm min. 35 mm min. Panel Cut-Out and Minimum Spacing Relay and SSR Outputs Analog Inputs 3. CONNECTION DIAGRAM RL1 13 RL2 14 01 06 SSR2 02 SSR1 07 03 08 Operating voltage suitable for the device type shall be applied. 04 09 AO1 05 11 12 10 RS 485 1st and 2nd control outputs can be selected as either Relay (RL1, RL2) or SSR (SSR1, SSR2). Only one of analog output (AO1) and RS-485 can be selected. Analog output (AO1) mA or 0-10 V DC can be selected. Analog Input 06 06 07 07 08 08 09 09 10 10 06 06 07 07 08 08 09 09 10 10 06 07 08 09 V 10 E-48P controller is designed for panel mounting and should be used in an industrial environment. The package of E-48P controller conta ns; Controller, 2 p eces of mount ng clamps, User manual and Guarantee cert f cate. After open ng the package, please check the contents w th the above l st. If the del vered product s wrong type, any tem s m ss ng or there are v s ble defects, contact the vendor from wh ch you purchased the product. Before nstall ng and operat ng the controller, please read the user manual thoroughly. The nstallat on and conf gurat on of the controller must only be performed by a person qual f ed n nstrumentat on. Keep the un t away from flamable gases, that could cause explos on. Do not use alcohol or other solvents to clean the controller. Use a clean cloth soaked n water t ghtly squeezed to gently w pe the outer surface of the controller. It s not used n med cal appl cat ons. EU DIRECTIVE COMPLIANCE Low Voltage D rect ve EN 61010-1 EMC D rect ve EN 61326-1 K - Q TSE-ISO-EN 9000 TS EN ISO 9001 Quality Management System Certificate 5. TYPE CODING E-48P Series Universal Advanced Controller E-48P - W - X - Y - Z Relay Outputs None 0 1 relay (RL1) 1 2 relays (RL1, RL2) 2 Reserved 3 1 SSR (SSR1) 4 1 SSR (SSR1) + 1 relay (RL2) 5 Reserved 6 2 SSR (SSR1, SSR2) 7 Reserved 8 Analog Outputs * 0 None 1 0-20 / 4-20 mA (AO1) 2 0-10 V DC (AO1) Communication None 0 RS-485 ** 1 Operating Voltage 85-265 V AC / 85-375 V DC 0 20-60 V AC / 20-60 V DC 1 * Only one of the analog output and RS-485 options can be coded. For example, only one of the options (X) and (Y) can be coded as 1. ** When E-48P Series controllers are ordered with communication, the E-IB-11 USB-RS485 converter can be used for PC connection. There are various control and monitoring software provided by Elimko. 6. TECHNICAL SPECIFICATIONS Parameter Description Control Type On/Off, PID, Heat/Cool, Floating and Feedback Control of Valves Operating Voltage 20..60 V AC / 20..60 V DC or 85..265 V AC / 85..375 V DC Relays / SSR 2 pieces SPST - NO 250 V AC 5A relays or 24 V DC 25 mA (SSR) drives Dimensions (mm) 48 (Lenght) x 48 (Height) x 100 (Width) Panel Cut-Out (mm) 45 (Lenght) x 45 (Height) Analog Output 1 x 0..20 / 4..20 mA or 0..10 V DC optional Analog Input Universal (Note 1), Communication (RS-485) Available (RS-485) Digital Input None Valve Feedback None Transmitter Supply Available Weight 115 g Power Consumption Max. 7 W (10 VA) Operating Temperature - 10 °C ... 55 °C Storage Temperature - 25 °C ... 65 °C Memory Maks. 100.000 write Protection Class IP-65 Front Panel, IP-20 Rear Case Notes: (1) Universal Input : Thermocouple : B, E, J, K, L, N, R, S, T, U Resistance Thermometer : Pt-100 Current : 0-20 mA, 4-20 mA (Linear) Voltage : 0-50 mV, 0-1 V, 0.2- 1 V (Linear), 0-10 V DC, must be specified in the order. Resolution : 16 bit Accuracy : Thermocouple, Max. ±1.0 °C (Conversion and CJC error) Resistance Thermometer, Max. ±0.5 °C (Conversion and wire resistance compensation) Linear Input, Max. % 0.1 ALARM SETTINGS ACNF CONTROL SET SETTINGS SETP INPUT SETTINGS gcnf 7. PARAMETER TABLE Description INP1 Analog Input 1 Type DP Decimal Point SCLO Analog Input 1 Linear Scale Lower Value SCHI Analog Input 1 Linear Scale Upper Value UNIT Temperature Unit OFST Analog Input 1 Offset Value FLTR Analog Input 1 Filter SNBR Analog Input 1 Sensor Broken Behaviour ADRS Modbus Adress BAUD Modbus Baud Rate [4.8, 9.6, 19.2, 38.4 kbaud] PRTY Modbus Parity [None, ODD, Even] SPSR Control Set Point Source SPLL Control Set Point Lower Limit SPHL Control Set Point Upper Limit SPRR Control Set Point Ramping Rate S-1 1. Step Set Value T-1 1. Step Time S-2 2. Step Set Value T-2 2. Step Time S-3 3. Step Set Value T-3 3. Step Time A1TP Alarm 1 Type A1SP Alarm 1 Set Point A1HY Alarm 1 Hysteresis A1LT Alarm 1 Lock A2TP Alarm 2 Type A2SP Alarm 2 Set Point A2HY Alarm 2 Hysteresis A2LT Alarm 2 Lock Min Maks Unit Table 1 0 3 -199.9 999.9 EU -199.9 999.9 EU *C *F -100.0 100.0 EU 1 15 s LO HI 1 127 4.8 38.4 Table 2 -199.9 SPHL EU SPLL 999.9 EU OFF 60.0 EU/min SPLL SPHL EU OFF 999.9 min SPLL SPHL EU OFF 999.9 min SPLL SPHL EU OFF 999.9 min Table 3 -199.9 999.9 EU 0.0 999.9 EU DSB ENB Table 3 -199.9 999.9 EU 0.0 999.9 EU DSB ENB OUTPUTS OCNF CTYP CFRM CPRD MNPR TRTM DBND OLL OHL OMR PONC TRLL TRHL RL1D RL2D AO1D AO1R Control Type Control Form [DIR, REV] Control Period Manual Mode Selection Floating Control Valve Travel Time Dead Band Control Output Lower Limit Control Output Upper Limit Control Output Manual Reset PID Power On Behaviour Retransmission Scale Lower Value Retransmission Scale Upper Value Relay 1 Function Relay 2 Function Analog Output 1 Function Analog Output 1 Type AT PID PB-1 PB-2 ITH ITC DTH DTC HYS PID Auto Tune PID Parameter Type Proportional Band + Proportional Band Integral Time + Integral Time Derivative Time + Derivative Time Hysteresis SCOD DPRL APRL FCST Security Code Parameter Access Level Parameter Setting Level Factory Settings [OFF, LOAD, SAVE, DFLT] Table 4 DIR REV 1 250 s DSB ENB 10 2500 s 0.1 25.0 % 0.0 OHL % OLL 100.0 % OLL OHL % 0 4 -199.9 TRHL EU TRLL 999.9 EU Table 5 Table 5 Table 6 Table 7.1 ve Table 7.2 OFF ON STD ADV 0.1 999.9 EU 0.1 999.9 EU OFF 9999 s OFF 9999 s OFF 2500 s OFF 2500 s 0.0 999.9 EU 0 9999 0 9 0 9 PID SETTINGS tUNE SECURITY PRTC 8. ACCESSING PARAMETERS STEP 1: STEP 2: Security Code Configuration Entry Page Selection (Default: 10) and Entry STEP 3: Parameter Selection and Configuration Process Screen 199.8 200.0 Selected Page SCOD 0 PAGE GCNF Parameters . . . Adjustment Enter Return Menu Access 9. APPLICATION EXAMPLES 1) Input: Pt-100 Relay / Alarm1: 50 °C Low, Relay2 / Alarm2: 55 °C High AO1: 4-20 mA PID Control Output inp1 a1tp a1sp a2tp a2sp ctyp rl1D rl2D ao1D ao1r pt lo 50.0 hi 55.0 sco al-1 al-2 co-1 4-20 2) Input: TC Type J, Relay1: On-Off Control Output, Relay2 / Alarm2: 350 °C High inp1 a2tp a2sp ctyp rl1D rl2D j hi 350.0 sco Do-1 al-2 3) Input: TC Type K, Profile Control (Ramp up to 400°C in 10 minutes and wait for 60 minutes), Relay1: PID Control Output, AO1: Retransmission Output (4-20 mA, 0-1200 °C) inp1 spsr s-1 t-1 s-2 t-2 ctyp trll trhl rl1D rl2D ao1D ao1r k prfl 400 10.0 400 60.0 sco 0 1200 co-1 al-2 pvtr 4-20 Table 1. Input Type Options b Type B Thermocouple e Type E Thermocouple j Type J Thermocouple k Type K Thermocouple l Type L Thermocouple n Type N Thermocouple r Type R Thermocouple s Type S Thermocouple t Type T Thermocouple u Type U Thermocouple pt Pt-100 0-20 0-20 mA 4-20 4-20 mA 0-50 0-50 mV 0.0-1 0-1 V 0.2-1 0.2-1 V 0-10 0-10 V (*) 2-10 2-10 V (*) (*) Custom specified volt input Table 2. Control Set Options int Internal adjustment with keys prfl With Profile Control Table 3. Alarm Options off Off lo Low Alarm hi High Alarm loD Low Deviation hiD High Deviation lob Band Alarm (In) hib Band Alarm (Out) Table 4. Control Type Options off No Control sco Single (Heat) Dco Double (Heat/Cool) bnD Floating Control of Valve Tablo 5. Relay Output Options co-1 PID + (Heating) co-2 PID - (Cooling) Do-1 On-Off + (Heating) Do-2 On-Off - (Cooling) al-1 Alarm 1 al-2 Alarm 2 al-3 Alarm 3 al-4 Alarm 4 Table 6. Analog Output Options co-1 PID + (Heating) co-2 PID - (Cooling) pvtr Process Value sptr Control Set Value Table 7.1. Analog Output Range 0-20 0-20 mA 20-0 20-0 mA 4-20 4-20 mA 20-4 20-4 mA Table 7.2. Analog Output Range 0-10 0-10 V 10-0 10-0 V 2-10 2-10 V 10-2 10-2 V For detailed information, you can access the comprehensive user manual of the device under the heading "User Manuals" at www.elimko.com.tr. You can also use the QR Code on the front for this. Elimko Elektronik malat ve Kontrol Ticaret Ltd. ti. Ankara Sanayi Odasi 2. Organize Sanayi Bölgesi Alci OSB Mahallesi 2001. Cad. No:14 Temelli 06909 Ankara / TURKYE Tel: +90 312 212 64 50 (Pbx) · Fax: +90 312 212 41 43 · E-mail: elimko@elimko.com.tr · www.elimko.com.tr