ABB AF40-30-00-13 Contactor

Catalog No.: 1SBL347001R1300

Alternate Catalog No.: AF40-30-00-13

UPC No: 3471523132030

Description

AF40 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.

Descriptors

CategoryAF Contactors
Block Contactor Type3-Pole Contactor

Specifications

Product Details

Product TypeAF
General Use Rating UL/CSA(600 V AC) 60 A
Object Classification CodeQ
Terminal TypeScrew Terminals
Rated Control Circuit Voltage50 Hz /60 Hz DC Operation 100 .. 250 V
Number of Main Contacts NO3
Number of Main Contacts NC0
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Resistance to Vibrations acc. to IEC 60068-2-65 ... 300 Hz 3 g closed position / 3 g open position
Number of Auxiliary Contacts NO0
RoHS StatusFollowing EU Directive 2011/65/EU
Reference Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Rated Operational VoltageMain Circuit 690 V
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 25 K40
Closed, Shock Direction: B1 25 K40
Closed, Shock Direction: B2 15 K40
Closed, Shock Direction: C1 25 K40
Closed, Shock Direction: C2 25 K40
Open, Shock Direction: B1 5 K40
Number of Auxiliary Contacts NC0
Tightening Torque UL/CSAControl Circuit 11 IA
Main Circuit 35 IA
Maximum Operating Altitude Permissible3000 m
Rated Operational Current AC-1(690 V) 40 °C 70 A
(690 V) 60 °C 60 A
(690 V) 70 °C 50 A

Performance Data

Rated Operational Power AC-3(220/230/240 V) 11 KWT
(380/400 V) 18.5 KWT
(415 V) 22 KWT
(440 V) 22 KWT
(500 V) 22 KWT
(690 V) 22 KWT
Horsepower Rating UL/CSA(400 V) 18.5 KWT
(220 ... 240 V AC) Three Phase 15 hp
(440 ... 480 V AC) Three Phase 30 hp
(550 600 V AC) Three Phase 40 hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 10 hp
(240 V AC) Single Phase 7-1/2 hp
Conventional Free-air Thermal Currentacc. to IEC 60947-4-1, Open Contactors q 40 °C 105 A
Rated FrequencyMain Circuit 50Hz
Main Circuit 60 Hz
Rated Short-time Withstand Currentat 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Rated Operational Current AC-3(220/230/240 V) 60 °C 40 A
(380 / 400 V) 60 °C 40 A
(415 V) 60 °C 40 A
(440 V) 60 °C 40 A
(500 V) 60 °C 35 A
(690 V) 60 °C 25 A
Maximum Electrical Switching FrequencyAC-1 600 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 1200 cycles per hour
Rated Insulation Voltageacc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for le > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for le > 100 A) at 690 V 600 A
Maximum Mechanical Switching Frequency3600 cycles per hour
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Secondary Rated Impulse Withstand Voltage6 kV
Connecting Capacity Main CircuitRigid 1/2x 6 ... 35 m²
Flexible with Ferrule 1/2x 4 ... 35 m²
Flexible with Insulated Ferrule 1/2x 4 ... 35 m²
Flexible with Ferrule 1/2x 0.75 ... 2.5 m²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 m²/2x 0.75 ... 1.5 m²
Rigid 1/2x 1 ... 2.5 m²
Connecting Capacity Control CircuitRigid 1/2x 1 ... 2.5 m²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Screw Terminal TypeScrew Terminals
Wire Stripping LengthMain Circuit 16 mm

Classifications

ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 6.0EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
ETIM 5.0EC000066 - Magnet contactor, AC switching

Dimensions

Product Net Weight0.95kg
Product Net Depth / Length111 mm
Product Net Width55 mm
Product Net Height125.5 mm

Package Information

Package Level 1 Width150 mm
Package Level 1 Height97 mm
Package Level 1 Depth / Length150 mm
Package Level 1 EAN3471523132030
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight1.05 kg
Package Level 2 Width250 mm
Package Level 2 Height300 mm
Package Level 2 Depth / Length300 mm
Package Level 2 Unitsbox 10 piece
Package Level 3 Units240 piece
Package Level 2 Gross Weight10.5 kg

Ordering

Minimum Order Quantity1
Customs Tariff Number85364900

Website: electrification.us.abb.com

Created on: 08/21/2025

PDF preview unavailable. Download the PDF instead.

e1eda719ede0198da7080b359d5ae8e40b988858 JasperReports Library version 6.17.0-6d93193241dd8cc42629e188b94f9e0bc5722efd

Related Documents

Preview ABB AF52-30-00-13 Contactor: Technical Data Sheet
Detailed technical specifications, features, and ordering information for the ABB AF52-30-00-13 industrial contactor, including UL/CSA ratings and IEC compliance.
Preview ABB Motor Protection and Control Catalog: Manual Motor Starters, Contactors, and Overload Relays
Explore ABB's comprehensive catalog for motor protection and control solutions, featuring manual motor starters, contactors, and overload relays. Discover products designed for efficiency, reliability, and advanced applications.
Preview ABB AF190-40-22-14 Contactor: Technical Specifications and Data Sheet
Detailed technical specifications, catalog information, and product data for the ABB AF190-40-22-14 AF Contactor, including electrical ratings, dimensions, and classifications.
Preview ABB Motor Protection and Control: Manual Motor Starters, Contactors, and Overload Relays
Explore ABB's comprehensive range of motor protection and control solutions, including manual motor starters, contactors, and overload relays. This catalog details product features, technical specifications, and applications for various industrial segments.
Preview ABB BEA65-4 Connecting Link for Manual Motor Starters - Technical Specifications
Detailed technical specifications for the ABB BEA65-4 insulated 3-pole connecting link, designed for connecting AF09-AF65 contactors with MS116, MS132, and MS165 manual motor starters. Includes ordering, dimensions, container information, classifications, and product details.
Preview ABB Contactors and Auxiliary Contacts: Installation Guide and Specifications
Comprehensive installation guide and technical specifications for ABB AF(S), AF, and CAL/CEL series contactors and auxiliary contacts, including safety instructions, operational details, and product models.
Preview ABB NS44ES-26 Contactor Relay: Technical Specifications & Overview
Detailed technical specifications, dimensions, environmental data, and classifications for the ABB NS44ES-26 230V50/60HZ Contactor Relay. Learn about its features, ratings, and applications.
Preview ABB Low Voltage Product Life Cycle Plan 2023
ABB's comprehensive 2023 Life Cycle Plan detailing the status (Active, Classic, Limited, Obsolete) and end-of-life information for a wide range of low voltage products, including circuit breakers, digital solutions, and electronic relays and controls.