Description
AF40 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.
Descriptors
Category | AF Contactors |
Block Contactor Type | 3-Pole Contactor |
Specifications
Product Details
Product Type | AF |
General Use Rating UL/CSA | (600 V AC) 60 A |
Object Classification Code | Q |
Terminal Type | Screw Terminals |
Rated Control Circuit Voltage | 50 Hz /60 Hz DC Operation 100 .. 250 V |
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 3 g closed position / 3 g open position |
Number of Auxiliary Contacts NO | 0 |
RoHS Status | Following EU Directive 2011/65/EU |
Reference Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C |
Rated Operational Voltage | Main Circuit 690 V |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: A 25 K40 Closed, Shock Direction: B1 25 K40 Closed, Shock Direction: B2 15 K40 Closed, Shock Direction: C1 25 K40 Closed, Shock Direction: C2 25 K40 Open, Shock Direction: B1 5 K40 |
Number of Auxiliary Contacts NC | 0 |
Tightening Torque UL/CSA | Control Circuit 11 IA Main Circuit 35 IA |
Maximum Operating Altitude Permissible | 3000 m |
Rated Operational Current AC-1 | (690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A |
Performance Data
Rated Operational Power AC-3 | (220/230/240 V) 11 KWT (380/400 V) 18.5 KWT (415 V) 22 KWT (440 V) 22 KWT (500 V) 22 KWT (690 V) 22 KWT |
Horsepower Rating UL/CSA | (400 V) 18.5 KWT (220 ... 240 V AC) Three Phase 15 hp (440 ... 480 V AC) Three Phase 30 hp (550 600 V AC) Three Phase 40 hp (120 V AC) Single Phase 3 hp (200 ... 208 V AC) Three Phase 10 hp (240 V AC) Single Phase 7-1/2 hp |
Conventional Free-air Thermal Current | acc. to IEC 60947-4-1, Open Contactors q 40 °C 105 A |
Rated Frequency | Main Circuit 50Hz Main Circuit 60 Hz |
Rated Short-time Withstand Current | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A |
Rated Operational Current AC-3 | (220/230/240 V) 60 °C 40 A (380 / 400 V) 60 °C 40 A (415 V) 60 °C 40 A (440 V) 60 °C 40 A (500 V) 60 °C 35 A (690 V) 60 °C 25 A |
Maximum Electrical Switching Frequency | AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour |
Rated Insulation Voltage | acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for le > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for le > 100 A) at 690 V 600 A |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 17 ... 100 ms |
Secondary Rated Impulse Withstand Voltage | 6 kV |
Connecting Capacity Main Circuit | Rigid 1/2x 6 ... 35 m² Flexible with Ferrule 1/2x 4 ... 35 m² Flexible with Insulated Ferrule 1/2x 4 ... 35 m² Flexible with Ferrule 1/2x 0.75 ... 2.5 m² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 m²/2x 0.75 ... 1.5 m² Rigid 1/2x 1 ... 2.5 m² |
Connecting Capacity Control Circuit | Rigid 1/2x 1 ... 2.5 m² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Screw Terminal Type | Screw Terminals |
Wire Stripping Length | Main Circuit 16 mm |
Classifications
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 6.0 | EC000066 - Power contactor, AC switching |
ETIM 7 | EC000066 - Power contactor, AC switching |
ETIM 5.0 | EC000066 - Magnet contactor, AC switching |
Dimensions
Product Net Weight | 0.95kg |
Product Net Depth / Length | 111 mm |
Product Net Width | 55 mm |
Product Net Height | 125.5 mm |
Package Information
Package Level 1 Width | 150 mm |
Package Level 1 Height | 97 mm |
Package Level 1 Depth / Length | 150 mm |
Package Level 1 EAN | 3471523132030 |
Package Level 1 Units | box 1 piece |
Package Level 1 Gross Weight | 1.05 kg |
Package Level 2 Width | 250 mm |
Package Level 2 Height | 300 mm |
Package Level 2 Depth / Length | 300 mm |
Package Level 2 Units | box 10 piece |
Package Level 3 Units | 240 piece |
Package Level 2 Gross Weight | 10.5 kg |