GREE MULTI R32
SUBMITTAL DATA
MUL36HP230V1R32AO
36000 BTU/H Multi-Zone Heat Pump System
Job Information
[Enter Job Name]
[Enter Purchaser]
[Enter Submitted To]
[Enter Unit Designation]
[Enter Location]
[Enter Engineer]
[Enter For]
[Enter Date]
[Enter Schedule No.]
Product Image
Image of a GREE outdoor unit, model MUL36HP230V1R32AO, showing its front panel with the GREE logo and fan grille.
General Features
- AHRI Certificate: 215218916 (Non-Ducted), 215218921 (Ducted), 215218926 (Mixed)
- High Efficiency DC Inverter Technology
- Compact and Quiet Design
- Auto Restart on Power Outages
- Multi-point Diagnostics
- Wi-Fi Included (Factory Installed)
- Low Ambient Cooling down to -22°F (Range -22°F to 118°F)
- Low Ambient Heating down to -22°F (Range -22°F to 75°F)
- Coil (Indoor and Outdoor) Copper Tube / Aluminum Fin
- Blue Colored Fin - 500 Hrs Salt Spray Tested
Multi-Zone Compatibility Chart
Wall Mount Options
System Model no. | MUL18HP230V1R32AO | MUL24HP230V1R32AO | MUL30HP230V1R32AO | MUL36HP230V1R32AO | MUL42HP230V1R32AO | MUL48HP230V1R32AO |
---|---|---|---|---|---|---|
LIVO | ||||||
LIV05HP230V1R32AH | • | • | • | • | • | • |
LIV07HP230V1R32AH | • | • | • | • | • | • |
LIV09HP230V1R32AH | • | • | • | • | • | • |
LIV12HP230V1R32AH | • | • | • | • | • | • |
LIV18HP230V1R32AH | • | • | • | • | • | • |
LIV24HP230V1R32AH | • | • | • | • | • | • |
LIV30HP230V1R32AH | • | • | • | • | • | • |
LIV36HP230V1R32AH | • | • | • | • | • | • |
VIREO | ||||||
VIR09HP230V1R32AH | • | • | • | • | • | • |
VIR12HP230V1R32AH | • | • | • | • | • | • |
VIR18HP230V1R32AH | • | • | • | • | • | • |
VIR24HP230V1R32AH | • | • | • | • | • | • |
ENVO | ||||||
ENV09HP230V1R32AH | • | • | • | • | • | • |
ENV12HP230V1R32AH | • | • | • | • | • | • |
ENV18HP230V1R32AH | • | • | • | • | • | • |
ENV24HP230V1R32AH | • | • | • | • | • | • |
SAPPHIRE | ||||||
SAP09HP230V1R32AH | • | • | • | • | • | • |
SAP12HP230V1R32AH | • | • | • | • | • | • |
SAP18HP230V1R32AH | • | • | • | • | • | • |
SAP24HP230V1R32AH | • | • | • | • | • | • |
Additional Indoor Unit Options
System Model no. | MUL18HP230V1R32AO | MUL24HP230V1R32AO | MUL30HP230V1R32AO | MUL36HP230V1R32AO | MUL42HP230V1R32AO | MUL48HP230V1R32AO |
---|---|---|---|---|---|---|
ONE WAY CASSETTE | ||||||
OWC09HP230V1R32AH | • | • | • | • | • | • |
OWC12HP230V1R32AH | • | • | • | • | • | • |
OWC18HP230V1R32AH | • | • | • | • | • | • |
OWC20HP230V1R32AH | • | • | • | • | • | • |
CEILING CASSETTE | ||||||
CAS09HP230V1R32AH | • | • | • | • | • | • |
CAS12HP230V1R32AH | • | • | • | • | • | • |
CAS18HP230V1R32AH | • | • | • | • | • | • |
CAS24HP230V1R32AH | • | • | • | • | • | • |
SLIM DUCT | ||||||
DUC09HP230V1R32AH | • | • | • | • | • | • |
DUC12HP230V1R32AH | • | • | • | • | • | • |
DUC18HP230V1R32AH | • | • | • | • | • | • |
DUC24HP230V1R32AH | • | • | • | • | • | • |
FLOOR/CEILING | ||||||
FLR09HP230V1R32AH | • | • | • | • | • | • |
FLR12HP230V1R32AH | • | • | • | • | • | • |
FLR18HP230V1R32AH | • | • | • | • | • | • |
FLR24HP230V1R32AH | • | • | • | • | • | • |
MINI-CONSOLE | ||||||
CON09HP230V1R32AH | • | • | • | • | • | • |
CON12HP230V1R32AH | • | • | • | • | • | • |
CON18HP230V1R32AH | • | • | • | • | • | • |
NOTE: R32 Indoor units are only compatible with R32 Outdoor units. Keep in mind, line set is always sized by the indoor unit valve diameter.
Specifications, Features & Function Summary
System Type
Outdoor Model | MUL36HP230V1R32A0 | Number of Zones | 2-4 |
---|---|---|---|
Port A (in) | 1/4 - 3/8 | Port B (in) | 1/4 - 3/8 |
Port Size (Liquid - Gas) | Port C (in) | 1/4 - 3/8 | |
Port D (in) | 1/4 - 3/8 | ||
Port E (in) |
System Performance (Non-Ducted Indoor Units)
Min - Max Btu/h | Rated Capacity Btu/h | |
---|---|---|
Cooling Capacity @95°F | 8,870 - 40,900 | 36,000 |
Heating Capacity @47°F | 8,870 - 51,180 | 36,000 |
Heating Capacity @17°F | 36,000 | |
SEER2 | 21 | |
EER2 | 12.0 | |
HSPF2 | 10.0 | |
COP @5°F | 2.10 |
System Performance (Ducted Indoor Units)
Min - Max Btu/h | Rated Capacity Btu/h | |
---|---|---|
Cooling Capacity @95°F | 8,870 - 40,900 | 36,000 |
Heating Capacity @47°F | 8,870 - 51,180 | 36,000 |
Heating Capacity @17°F | 36,000 | |
SEER2 | 18.0 | |
EER2 | 11.7 | |
HSPF2 | 8.1 | |
COP @5°F | 1.90 |
System Performance (Mixed Ducted and Non-Ducted Indoor Units)
Min - Max Btu/h | Rated Capacity Btu/h | |
---|---|---|
Cooling Capacity @95°F | 8,870 - 40,900 | 36,000 |
Heating Capacity @47°F | 8,870 - 51,180 | 36,000 |
Heating Capacity @17°F | 36,000 | |
SEER2 | 19.0 | |
EER2 | 11.8 | |
HSPF2 | 9.0 | |
COP @5°F | 1.84 |
Outdoor Unit: MUL36HP230V1R32AO
Cooling Temperature Range | -22-118 °F | Heating Temperature Range | -22-75 °F |
---|---|---|---|
Refrigerant Type | R32 | ||
Compressor Type | GREE G-20 / Double Cylinder / 1-STAGE INVERTER | ||
Sound Pressure Level | 59 dB(A) | Pre-Charge Length | 131 ft |
External Dimensions (W x H x D) | 40-10/64 x 32-33/64 x 16-52/64 in | Pipe Length (Min - Max) | 10-263 ft |
Package Dimension (W x H x D) | 43-1/32 x 34-27/32 x 19-9/16 in | Pipe Length to furthest Indoor Unit | 82 ft |
Net Weight | 173.1 lbs | Max. Pipe Elevation | 82 ft |
Gross Weight | 188.5 lbs |
Refrigerant Piping
Refrigerant Charge - R32 | 95.256 oz |
---|---|
Compressor Type | GREE G-20 / Double Cylinder / 1- STAGE INVERTER |
Additional Charge | 0.2 oz/ft |
Electrical
Power Supply | 208-230V/1Ph/ 60Hz |
---|---|
Voltage Range (Min - Max) | 187-253 VAC |
Rated Current - Cooling | 21.7 A |
Rated Current - Heating | 22.6 A |
MOCP | 35 A |
MCA | 30 A |
Main Power Wire Size | Per Local Code AWG |
Interconnecting Wire Size | 14/4 AWG |
Features & Functions Summary
Inverter Type | G20 |
---|---|
Ultra Low Frequency Torque Control | Yes |
Compressor Type - Inverter | Yes |
Basepan With Electric Heater | High Efficiency Rotary |
Indoor & Outdoor Fin Coating (Blue Fin) | Yes |
Intelligent Defrosting | Yes |
Intelligent Preheating | Yes |
Low Voltage Startup | Yes |
Memory/Power Failure Recovery | Yes |
Self Diagnosis | Yes |
Allowable Combinations Capacities
Outdoor Unit & Possible Indoor Unit Combinations with AHRI Certified Performance
*You may substitute the 9K unit with a 5K or 7K High Wall unit, find complete capacity information in the extended ratings chart.
MODEL NUMBER | POSSIBLE COMBINATIONS* | COOLING CAPACITY (Btu/h) | HEATING CAPACITY (Btu/h) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ZONE1 | ZONE2 | ZONE3 | ZONE4 | ZONE5 | ZONE1 | ZONE2 | ZONE3 | ZONE4 | ZONE5 | ||
MUL36HP230V1R32AO | 7K+7K+7K | 7,000 | 7,000 | 7,000 | 8,000 | 8,000 | 8,000 | ||||
MUL36HP230V1R32AO | 5K+7K+7K | 5,000 | 7,000 | 7,000 | 6,000 | 8,000 | 8,000 | ||||
MUL36HP230V1R32AO | 5K+5K+5K+5K | 5,000 | 5,000 | 5,000 | 5,000 | 6,000 | 6,000 | 6,000 | 6,000 | ||
MUL36HP230V1R32AO | 7K+7K+7K+7K | 7,000 | 7,000 | 7,000 | 7,000 | 8,000 | 8,000 | 8,000 | 8,000 | ||
MUL36HP230V1R32AO | 5K+5K+5K+7K | 5,000 | 5,000 | 5,000 | 7,000 | 6,000 | 6,000 | 6,000 | 8,000 | ||
MUL36HP230V1R32AO | 5K+5K+7K+7K | 5,000 | 5,000 | 7,000 | 7,000 | 6,000 | 6,000 | 8,000 | 8,000 | ||
MUL36HP230V1R32AO | 5K+7K+7K+7K | 5,000 | 7,000 | 7,000 | 7,000 | 6,000 | 8,000 | 8,000 | 8,000 | ||
MUL36HP230V1R32AO | 9K+9K | 9,000 | 9,000 | 9,000 | 9,000 | ||||||
MUL36HP230V1R32AO | 9K+12K | 9,000 | 12,000 | 9,000 | 12,000 | ||||||
MUL36HP230V1R32AO | 9K+18K | 9,000 | 18,000 | 9,000 | 18,000 | ||||||
MUL36HP230V1R32AO | 9K+24K | 9,000 | 24,000 | 9,000 | 24,000 | ||||||
MUL36HP230V1R32AO | 12K+12K | 12,000 | 12,000 | 12,000 | 12,000 | ||||||
MUL36HP230V1R32AO | 12K+18K | 12,000 | 18,000 | 12,000 | 18,000 | ||||||
MUL36HP230V1R32AO | 12K+24K | 12,000 | 24,000 | 12,000 | 24,000 | ||||||
MUL36HP230V1R32AO | 18K+18K | 18,000 | 18,000 | 18,000 | 18,000 | ||||||
MUL36HP230V1R32AO | 18K+24K | 15,429 | 20,571 | 15,429 | 20,571 | ||||||
MUL36HP230V1R32AO | 21K+24K | 16,800 | 19,200 | 16,800 | 19,200 | ||||||
MUL36HP230V1R32AO | 24K+24K | 18,000 | 18,000 | 18,000 | 18,000 | ||||||
MUL36HP230V1R32AO | 9K+9K+9K | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | ||||
MUL36HP230V1R32AO | 9K+9K+12K | 9,000 | 9,000 | 12,000 | 9,000 | 9,000 | 12,000 | ||||
MUL36HP230V1R32AO | 9K+9K+18K | 9,000 | 9,000 | 18,000 | 9,000 | 9,000 | 18,000 | ||||
MUL36HP230V1R32AO | 9K+9K+24K | 7,714 | 7,714 | 20,571 | 7,714 | 7,714 | 20,571 | ||||
MUL36HP230V1R32AO | 9K+12K+12K | 9,000 | 12,000 | 12,000 | 9,000 | 12,000 | 12,000 | ||||
MUL36HP230V1R32AO | 9K+12K+18K | 8,308 | 11,077 | 16,615 | 8,308 | 11,077 | 16,615 | ||||
MUL36HP230V1R32AO | 9K+12K+24K | 7,200 | 9,600 | 19,200 | 7,200 | 9,600 | 19,200 | ||||
MUL36HP230V1R32AO | 9K+18K+18K | 7,200 | 14,400 | 14,400 | 7,200 | 14,400 | 14,400 | ||||
MUL36HP230V1R32AO | 9K+18K+24K | 6,353 | 12,706 | 16,941 | 6,353 | 12,706 | 16,941 | ||||
MUL36HP230V1R32AO | 9K+21K+24K | 6,000 | 14,000 | 16,000 | 6,000 | 14,000 | 16,000 | ||||
MUL36HP230V1R32AO | 12K+12K+12K | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | ||||
MUL36HP230V1R32AO | 12K+12K+18K | 10,286 | 10,286 | 15,429 | 10,286 | 10,286 | 15,429 | ||||
MUL36HP230V1R32AO | 12K+12K+24K | 9,000 | 9,000 | 18,000 | 9,000 | 9,000 | 18,000 | ||||
MUL36HP230V1R32AO | 12K+18K+18K | 9,000 | 13,500 | 13,500 | 9,000 | 13,500 | 13,500 | ||||
MUL36HP230V1R32AO | 12K+18K+24K | 8,000 | 12,000 | 16,000 | 8,000 | 12,000 | 16,000 | ||||
MUL36HP230V1R32AO | 18K+18K+18K | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | ||||
MUL36HP230V1R32AO | 9K+9K+9K+9K | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | ||
MUL36HP230V1R32AO | 9K+9K+9K+12K | 8,308 | 8,308 | 8,308 | 11,077 | 8,308 | 8,308 | 8,308 | 11,077 | ||
MUL36HP230V1R32AO | 9K+9K+9K+18K | 7,200 | 7,200 | 7,200 | 14,400 | 7,200 | 7,200 | 7,200 | 14,400 | ||
MUL36HP230V1R32AO | 9K+9K+9K+24K | 6,353 | 6,353 | 6,353 | 16,941 | 6,353 | 6,353 | 6,353 | 16,941 | ||
MUL36HP230V1R32AO | 9K+9K+12K+12K | 7,714 | 7,714 | 10,286 | 10,286 | 7,714 | 7,714 | 10,286 | 10,286 | ||
MUL36HP230V1R32AO | 9K+9K+12K+18K | 6,750 | 6,750 | 9,000 | 13,500 | 6,750 | 6,750 | 9,000 | 13,500 | ||
MUL36HP230V1R32AO | 9K+9K+12K+24K | 6,000 | 6,000 | 8,000 | 16,000 | 6,000 | 6,000 | 8,000 | 16,000 | ||
MUL36HP230V1R32AO | 9K+9K+18K+18K | 6,000 | 6,000 | 12,000 | 12,000 | 6,000 | 6,000 | 12,000 | 12,000 | ||
MUL36HP230V1R32AO | 9K+12K+12K+12K | 7,200 | 9,600 | 9,600 | 9,600 | 7,200 | 9,600 | 9,600 | 9,600 | ||
MUL36HP230V1R32AO | 9K+12K+12K+18K | 6,353 | 8,471 | 8,471 | 12,706 | 6,353 | 8,471 | 8,471 | 12,706 | ||
MUL36HP230V1R32AO | 12K+12K+12K+12K | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | 9,000 | ||
MUL36HP230V1R32AO | 12K+12K+12K+18K | 8,000 | 8,000 | 8,000 | 12,000 | 8,000 | 8,000 | 8,000 | 12,000 |
Dimensions
Outdoor Unit
Unit: inch
Model: MUL36HP230V1R32AO
Diagram showing the dimensions of the GREE MUL36HP230V1R32AO outdoor unit. Front view shows width (37 1/8 inches), height (32 33/64 inches), and depth (16 13/16 inches). Side view shows width (40 5/32 inches), height (32 33/64 inches), and depth (14 17/32 inches). Top view shows width (40 5/32 inches) and depth (15 19/32 inches). A separate view shows a depth of 25 inches.
Clearances
Outdoor Unit Minimum Clearance
Diagram illustrating minimum installation clearances for the GREE outdoor unit. Space to the obstruction at least 12 inches (top). Space to the wall at least 6 inches (back, with a note that it can be reduced to 3 inches if the bottom is free of obstructions). Space to the obstruction at least 6 inches (sides). Space to the obstruction at least 24 inches (front).