User Manual for GENMAX models including: GM2800iA Portable Inverter Generator, GM2800iA, Portable Inverter Generator, Inverter Generator, Generator
Genmax GM3500iAED 3500W Dual Fuel Inverter Generator: User Review & Specs With the basic documentation and an
R USER MANUAL FOR MODELS: GM2800iA/GM2800iAE Portable Inverter Generator 2500 Running Watts | 2800 Peak Watts GM3500iA/GM3500iAE/GM3500iAED Portable Inverter Generator 3200(GAS.)/2800(LPG) Running Watts | 3500(GAS.)/3100(LPG) Peak Watts CHONGQING DINKING POWER MACHINERY CO., LTD GM2800iA GM2800iAE GM3500iA GM3500iAE GM3500iAED (Gal) 2500 2800 1.58 2500 2800 1.58 3200 3500 1.58 3200 3200(GAS.) 2800(LPG) 3500 1.58 3500(GAS.) 3100(LPG) 1.58 4500 4500 4850 4850 4850 A5RTC 145 A5RTC 145 A5RTC 145 A5RTC 145 A5RTC 145 64×45 64×45 64×45 64×45 64×45 (Gal) 0.12 0.12 0.12 0.12 0.12 10W30 10W30 10W30 10W30 10W30 2 LIMITED WARRANTY 1. Email: warrantiessmallengines@gmail.com Phone: 866-960-2920 WARRANTY CARD Name: ___________________________________________ Model Number: _____________________________________ Street Address: ___________________________________ Serial Number:______________________________________ City, State, ZIP:____________________________________ Date Purchased: ____________________________________ Country: __________________________________________ Purchased From:____________________________________ Phone Number: ___________________________________ R E-Mail: ___________________________________________ 3 17 LIMITED WARRANTY 17 Warranty Card 18 18 18 19 19 19 20 21 22 22 22 23 11 11 SCHEMATICS 24 11 11 11 11 GENMAX 11 12 12 13 14 14 14 15 16 16 16 4 Connection of the product to a building's electrical system is not applicable. 5 6 SAFETY LABELS AND DECALS 6 6 Three-prong Plug (1) 7 BASIC INVERTER FEATURES 7 3 Fuel Cap: Open the fuel tank cap and fill with proper amount of gasoline. 8 10 9 4 2 GM2800iA/GM3500iA USB Duplex: 5V DC that come in 1 amps and 2.1 amps. 120-Volt, 30-Amp Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps. Multifunctional LED Digital Display Meter: Red light (LOW OIL) means that the amount of oil is too low, red light (OVERLOAD) means that the machine overload, green light (POWER) means normal operation. LED Digital Display shows time, voltage, power, frequency and oil level; Time: scrolling display of single running time and accumulated running time; voltage: scrolling display of 120V and 240V. Efficiency Mode Switch: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel. Parallel Connectors: To increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets is only used to the communication between the inverters, they cannot used for AC power output. The special paralleling cords shall be purchase separately, and they shall be approved by certification body. AC Protector: If the inverter is overload, the AC protector will trip to block current. 10 CO Alarm : Flashing red light: dangerous levels of carbon monoxide gas have built up leave immediately until area has aired out. Move generator to well-ventilated area before operation. Flashing yellow light: carbon monoxide sensor malfunction. Sensor needs service. 9 4 11 2 9 10 GM2800iAE/GM3500iAE/GM3500iAED USB Duplex: 5V DC that come in 1 amps and 2.1 amps. One Push Start: Press this button, the engine can start and stop. Press this button for 3-5 seconds until the green light is on, and then press the ON/OFF button on the remote control key until the light is off. At this time, the remote control matches successfully. Multifunctional LED Digital Display Meter: Red light (LOW OIL) means that the amount of oil is too low, red light (OVERLOAD) means that the machine overload, green light (POWER) means normal operation. LED Digital Display shows time, voltage, power, frequency and oil level; Time: scrolling display of single running time and accumulated running time; voltage: scrolling display of 120V and 240V. Efficiency Mode Switch: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel. Parallel Connectors: To increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets is only used to the communication between the inverters, they cannot used for AC power output. The special paralleling cords shall be purchase separately, and they shall be approved by certification body. AC Protector: If the inverter is overload, the AC protector will trip to block current. 10 CO Alarm : Flashing red light: dangerous levels of carbon monoxide gas have built up leave immediately until area has aired out. Move generator to well-ventilated area before operation. Flashing yellow light: carbon monoxide sensor malfunction. Sensor needs service. 11 120-Volt, 30-Amp Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps. 10 GENMAX Carbon Monoxide Specification CO DETECT technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Sensor detects unsafe elevated levels of CO gas, it automatically shuts off the engine. CO Sensor is not a substitute for an indoor carbon monoxide alarm or for safe operation. DO NOT allow engine exhaust fumes to enter a confined area through windows, doors, vents or other openings. Generators must ALWAYS be used outdoors, far away from occupied buildings with engine exhaust pointed away from people and buildings. Meets the requirements of ANSI/PGMA G300-2018. 11 GENMAX GENMAX GENMAX 12 Loosen the knob on the right exterior cover and remove the right exterior cover (see Figure 1). 13 14 10 10 10 10 Recoil Starter 1. Remove all the loads out of the output; 2. Turn the fuel switch to "ON"; 3. Turn the engine switch to "ON"; 4. Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling out from the inverter. Pull the Recoil Handle out from Inverter (see Figure 6). Tip: When pulling the hand starter, hold the generator carrying handle firmly, to prevent the generator from overturning. Figure 6 Electric Starting 1. Remove all the loads out of the output. 2. Turn the fuel switch to "ON". 3. Press "START UP" to START the generator. Remote Start 1. Remove all the loads out of the output. 2. Turn the fuel switch to "ON". 3. Press "ON" on the remote control for 1 second and the generator runs normally. Remote Control Pairing 1. Press the "START" button for 5 seconds, release it when the "START/MATCH" indicator lights up. 2. Press "ON"/"OFF" on the remote control until the indicator lights off. 3. Press "ON" on the remote control for 1 second, when the generator starts, the function is paired successfully. Tip: The remote control supplied with the generator has been paired successfully. Dual Fuel 1. Using fuel oil: Turn the oil/gas switch to GAS., and then start and run the generator according to normal start-up steps; 2. Use gas: turn the oil and gas conversion switch to gas, open the gas cylinder, press the thickening valve button on the secondary pressure reducing valve, and start the generator according to the normal start-up steps. Procedure For Connecting Gas Pipes 1. Connect the pressure reducing valve assembly to the gas tank and tighten it; 2. Connect the dedicated gas hose to the generator; 3. Switch the oil/gas switch to gas gear; 4. Open the gas valve on the fuel tank and start the generator according to the normal start-up steps. 15 1. Remove all the loads out of the output. 3. Turn off the fuel (or gas) switch. 2. Press "START UP" to stop the generator. To stop the engine in an emergency, please directly press "START UP" to stop the generator. (see Figure 7). Figure 7 16 17 Figure 8. Figure 8 Figure 8. 18 (see Figure 9). Figure 9 (see Figure 11). Figure 10 Figure 11 19 (see Figure 12). Figure 12 Figure 13 (see Figure 14) Figure 14 (see Figure 13). 20 3. Unscrew the bolts and remove the left exterior cover plate (see Figure 15). Figure 15 (see Figure 16). Figure 16 21 (see Figure 17). Figure 17 22 23 GM2800iA/GM3500iA 24 GM2800iAE/GM3500iAE 25 GM3500iAED 26 R CHONGQING DINKING POWER MACHINERY CO.,LTD. CAOJIE DEVELOPMENT AREA, INDUSTRIAL PARK, HECHUAN, CHONGQING, CHINA 27 6800.J05.GEM.02.00 V1Corel PDF Engine Version 18.1.0.661 CorelDRAW X8