Instruction Manual for AGROWtEK models including: SXL-D-RX1 Drain Control System with Outlet Relay, SXL-D-RX1, Drain Control System with Outlet Relay, Control System with Outlet Relay, Outlet Relay

Hydrobuilder


File Info : application/pdf, 1 Pages, 541.72KB

PDF preview unavailable. Download the PDF instead.

IM SXLDR
AGROWtEK
Technology to Help You Grow

SXL-D-RX1
Drain Control System with Outlet Relay

Drain Control | High - Low Sensing

Electronic optical "liquid level control system" includes two liquid

sensors for high and low drain control of water with a RX1 outlet

relay. Simply install the sensors and wire the kit according to the

instructions below. The system automatically drains the tank by

turning the outlet. No other control system is required.

Made in

How It Works

USA

The high-level sensor turns on the outlet to operate until liquid drains below the low-level sensor.

Installation

1. Mark the tank wall at the desired high and low points. 2. Thick Wall: Drill 7/16" holes and tap with a 1/4 NPT tap. Thread sensor in hole.
Thin Wall (3/16" & under): Drill a 17/32" hole, place o-ring on sensor & nut inside tank. 3. Tighten sensor and check for leaks. Use teflon tape for tapped holes. 4. Make electrical connections according to the diagrams below.
Wiring Diagram

WARNING: DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.

DRAIN

NOTES:

AGROWtEK
Technology to Help You Grow
RX1

1. Check sensor type marking through hex head.
2. Use o-ring & nut in thin, flat-wall tanks. Locate o-ring between sensor hex head and outside tank wall.
3. Customer must provide two-conductor wire cable (minimum 22AWG) to connect valve to sensors.

Relay Outlet © Agrowtek Inc. | www.agrowtek.com
MADE IN U.S.A.
+ -
24Vdc

SXL-1 Wet-ON Marking: "Wet"
V+ GND OUT
V+ GND OUT
SXL-1X Wet-ON Latch Marking: "xWet"

High Level Sensor Turn ON (Open)
Low Level Sensor Turn OFF (Close)

Sensor/LED Status

Status High Sensor Low Sensor

Empty Sensor OFF, LED OFF Sensor OFF, LED Flash/10sec

Mid-Level Sensor OFF, LED Flash/10sec Sensor ON, LED ON

High Sensor ON, LED ON Sensor ON, LED ON

Draining Sensor ON, LED ON FlashOFF/10sec Sensor ON, LED ON

Specifications

Kits

Voltage Input: Output Current: Current Consumption: Mounting Thread: Hex Size: Body Material: Temperature Range: Wire Gauge:

5-24Vdc Max 1A (sourcing) 20mA per sensor 1/4" NPT 3/4" (19mm) Polysulphone -20 to 80°C (non-freezing) 26 - 16 AWG

SXL-D-RX1
120V Outlet Relay Drain Mode Optical Level Sensors

See SXL and RX1 manuals or contact Agrowtek Inc. for warranty terms and conditions.

Individual Sensors
SXL - 1
1: Low Drain Sensor 1B: High Drain Sensor

© Agrowtek Inc. | www.agrowtek.com | Technology to Help You GrowTM



References