Installation Guide for DINSTAR models including: SBC300 Session Border Controller, SBC300, Session Border Controller, Border Controller, Controller

DINSTAR SBC Quick Installation Guide

DINSTAR

DINSTAR SBC Quick Installation Guide

il y a 2 jours — 100-240VAC 50-60HZ. SBC3000. Power Indicator for MFU. Running Indicator for MFU. Screws. Network port for service. Power Indicator for MCU.

100-240VAC 50-60HZ. SBC3000. Power Indicator for MFU. Running Indicator for MFU. Screws. Network port for service. Power Indicator for MCU.


File Info : application/pdf, 12 Pages, 1.27MB

PDF preview unavailable. Download the PDF instead.

DINSTAR SBC Quick Installation Guide
Quick Installation Guide
SBC300 SBC1000 SBC3000
Thanks for Choosing Dinstar's Session Border Controller!
Please read this guide carefully before installing the gateway. If you need any technical support, please contact us. Tel: +86 755 61919966 Email: support@dinstar.com Website: www.dinstar.com

1 SBC Series Technical Specifications

SPEC Network Port

Model

for Service

SBC300

4

SBC1000

4

SBC3000

4

Network Port for Management
1
1
0

Max Concurrent
50
500 2,000

Max Registration
1,000 5,000
10,000

2 SBC Series Technical Specifications

Indicator

Definition

Status

Description

PWR RUN

Power Indicator

On

The device is switched on

Off

The power is switched off or there is no power supply

Blinking slowly The device is running properly Running Indicator

On/Off

The device goes wrong

ALM Alarm Indicator

Off

The system is working properly

On

The system is down

Network

Blinking quickly The device is properly connected to network

Link Indicator GE

Off

The device is not connected to network or network connection is improper

Network Speed Indicator

On

Work at 1,000Mbps

Off

Network speed lower than 1,000Mbps

3 Indicators and Ports
SBC300

PWR RUN ALM SIM TF

0 E1/T1

TF Console

1

GE Link Speed
3 2 1 0 Admin

Power Indicator Running Indicator
Alarm Indicator SIM Card Indicator
TF Card Indicator

TF Card

E1/T1

Slot

In-use Indicator Network Link Indicator

USB Interface Console Port

Network Speed Indicator

DC12V

GE

0

1

2

3

Admin

RST

Power Jack Network port for service Network port for Reset Button Management

SBC1000

PWR RUN ALM SIM

Console

0 E1/T1
1

GE Link Speed
3 2 1 0 Admin

Power Indicator Running Indicator
Alarm Indicator SIM Card Indicator

Console Port

E1/T1

Network Link Indicator

USB Interface

In-use Indicator Network Speed Indicator

SBC1000
Cooling Fan

OFF

POWER0

OFF

POWER1

ON 100-240VAC50-60HZ

ON 100-240VAC50-60HZ

E1/T1

GE

0

1

0

1

2

3

Admin SIM

RST

Power Switch Power Jack

E1/T1 Ports

Network port Network port for SIM card Reset Grounding for service Management Slot Button Lug

SBC3000

MFU PWR RUN
MFU PWR RUN

Mediaprocessor GE2 GE3

MFU PWR RUN
MFU PWR RUN

Mediaprocessor Mediaprocessor

MCU
MCU PWR RUN

Mediaprocessor GE0 GE1 CONSOLE RST

SBC3000

Screws Power Indicator for MFU Running Indicator for MFU

Network port for service

Power Indicator for MCU Running Indicator for MCU

Network port for service
USB Interface

Reset Button Console Port Network port for
Management

POWER0 POWER1

100-240VAC50-60HZ

100-240VAC50-60HZ

Grounding Lug Power Power Switch Jack

Cooling Fan

Screws

4 Attentions before Installing
The SBC1000/SBC3000 mounting cabinets should be 19 inches in width and 550 mm or more in depth (Dinstar provides the required brackets for installation); To guarantee device works normally and to lengthen the service life of the device, the humidity of the equipment room where device is installed should be maintained at 10%-90% (non-condensing), and temperature should be 0~45;
It's suggested that personnel who has experience or who has received related training be responsible for installing and maintaining device; Power supply of SBC300 should be 12V DC, and power supply of SBC1000/SBC3000 should be 100~240V AC; It's advised to adopt uninterruptible power supply (UPS); Please wear ESD wrist strap when installing device; Please do not hot plug cables; Ensure the equipment room is well-ventilated and clean.

5 Installation Instruction

Connection Diagram for SBC300 Connect to the network
GE

DC12V

0

1

2

3

Admin

RST

Network port for service

Network port for Management 192.168.11.XXX

Connect to the power supply
GE

DC12V

0

1

2

3

Admin

PC 192.168.11.XXX
RST

DC 12V

Connection Diagram for SBC1000 Connect to the network

POWER0 OFF

OFF

POWER1

ON 100-240VAC50-60HZ

ON 100-240VAC50-60HZ

E1/T1

0

1

GE

0

1

2

3

Admin SIM

RST

Network port for service

Network port for Management 192.168.11.1

PC 192.168.11.XXX

Connect with power input and grounding lug

POWER0 OFF

OFF

POWER1

ON 100-240VAC50-60HZ

ON 100-240VAC50-60HZ

E1/T1

GE

0

1

0

1

2

3

Admin SIM

RST

AC 100-240V

AC 100-240V

Grounding Cable Grounding Lug

Connection Diagram for SBC3000 Connect to the network

MFU PWR RUN
MFU PWR RUN

Mediaprocessor GE2 GE3

MFU PWR RUN
MFU PWR RUN

Mediaprocessor Mediaprocessor

MCU
MCU PWR RUN

Mediaprocessor GE0 GE1 CONSOLE RST

SBC3000

Network port for service

Network port for Management 192.168.11.1
PC 192.168.11.XXX

Connect with power input and grounding lug

100-240VAC50-60HZ

100-240VAC50-60HZ

POWER0 POWER1

Grounding Cable Grounding Lug

AC 100-240V

AC 100-240V

6 Modify PC's IP Address
To log in the Web Management System of the SBC, you need to modify the lP address of PC first to make it at the same network segment with the SBC. Connect PC with the SBC, and then add an lP address of 192.168.11.XXX on the PC. 1 On the PC, click `Network (or Ethernet)  Properties'.
2 Double-click `Internet Protocol Version 4 (TCP/IPv4)'.
3 Select `Use the following IP address', and then enter an available IP address `192.168.11.XXX' .

7 Log in Web Management System
Connect the computer to the GE1 port of SBC3000 (or the Admin port of SBC300/SBC1000), then open the browser, enter the IP address (https:// 192.168.11.1) in the browser, press enter, and the login GUI will be displayed.

Model SBC300 SBC1000 SBC3000

Network port for Management Admin Admin GE1

IP Address 192.168.11.1 192.168.11.1 192.168.11.1

Enter username and password in the displayed login GUI. The default username is admin, while the default password is admin@123#.

8 Modify IP Address of Network Port for Service
After logging in the SBC, user needs to modify the lP address of the network port for service. After that, please restart the device for the configurations to take effect. Note: The GE1 port of SBC3000 also can be used as a network port for service, but the Admin port of SBC300/SBC1000 is only used for local management and maintenance.

9 Configure Access Network
On the 'Service - Access Network' page, users can configure the Access Network to use SBC for proxy registration The signaling and media interfaces are the same as the corresponding network port for service. The local SIP listening port is 5090(customizable), and other configuration items keep the default.

10 Configure Access SIP Trunk
On the 'Service - Access Network' page, users can configure the Access SIP Trunk to connect SBC with service provider or third-party SIP line provider. The signaling and media interfaces are the same as the corresponding network port for service. The local SIP listening port is 5070 (customizable), and the Remote IP: Port is the server IP and port provided by the Service Provider.
11 Configure Call Routing
(1) Configure Call Routing(Core SIP Trunk Access SIP Trunk) On 'Service - Routing Profile ­ Call Routing' page, add an outbound route, select Core SIP Trunk as the source and Access SIP Trunk as the destination, and keep the other configuration items as default. Set the priority (the smaller the number, the higher the priority) and the description:

Select Core SIP Trunk as the source:
Select Access SIP Trunk as the destination:
(2) Configure Call Routing(Access SIP Trunk  Core SIP Trunk) On 'Service - Routing Profile ­ Call Routing' page, add an inbound route, select Access SIP Trunk as the source and Core SIP Trunk as the destination, and keep the other configuration items as default. Set the priority (the smaller the number, the higher the priority) and the description:
Select Access SIP Trunk as the source:

Select Core SIP Trunk as the destination:
Note: Based on the above steps, users can configure the call routing in the direction of Access Network  Core SIP Trunk or Core SIP Trunk  Access Network.
12 Trouble Shooting
(1) Unable to access the device WEB GUI.  First, check whether the access network port is the Network Port for management, the Network Port for service is not allowed to access the Web GUI by default;  To access the WEB GUI of SBC, you need to use HTTPS method, default port 443;  Using Ping to check whether the network works normally. If the network is not accessible, you need to check whether the IP address of the device is correct and whether the indicator of the network port is normal.
(2) Why the extension fails to register through the access network?  First, check the basic configuration of the SBC, such as whether the network port, SIP listening port and Call Routing are correct;  Then check that the Server IP and port of the end device are the same as the IP and port of the SBC Access Network;  Capture the network packets (on the Maintenance page), and check whether the SBC has received the registered packets and whether they have been successfully forwarded to the Core SIP Trunk.
(3) Why the call through SBC is failed?  First, check whether the Access Network registration is successful and whether the status of the Access SIP Trunk and Core SIP Trunk is True;  Checking that Call Routing is configured correctly;  Capture the network packets (on the Maintenance page), and check that the SBC has received the Call Request message;  Log in to SSH command line to capture call logs and provide them to technical support.
(4) Forget the management port IP address of the device.  If other service ports can access the device, you can try to use the IP access of the service ports;  Prepare an RS232 Console cable and a computer with a COM interface, then connect the device's Console port to access the device Command line interface, enter the command "show int" in ROS# mode to get the IP address of the device.
13 Tips for security settings
To protect the system service security, please configure the security rules according to the specific service requirements. For example: IP anti-attack policy, SIP anti-attack policy, system security, access control, black and white list, IP address whitelist, etc. If you have any questions about the configuration and parameters, please contact technical support.



References

Corel PDF Engine Version 17.4.0.887