User Guide for Healthcare models including: Omnipod 5, Omnipod

Omnipod 5

instructions during First Time Setup to enter your initial settings into the Omnipod ... The Bluetooth word mark and logos are registered trademarks owned.


File Info : application/pdf, 9 Pages, 6.57MB

PDF preview unavailable. Download the PDF instead.

Omnipod-5 Settings Transfer Guide US English
WELCOME TO THE
Omnipod® 5
AUTOMATED INSULIN DELIVERY SYSTEM
Settings Transfer Guide

FOR CURRENT
Omnipod DASH®
USERS

Settings
Many of the settings in your Omnipod DASH System are similar to those in the Omnipod 5. But, it is important to remember that because Omnipod 5 is an automated insulin delivery system, it works differently than the Omnipod DASH System. Because of this, it is very important to consider your current settings and discuss them with your healthcare provider before getting started. Find your current settings using the instructions below. Write your current settings on the table provided on page 5.
Basal Settings

1. From the Home screen tap Menu icon

2. Tap Basal Programs

3. Tap EDIT to view the basal program. If you have an active Pod, you will need to tap SUSPEND INSULIN to view the active basal program. Review Program Name/Tag. Tap NEXT.

4. Review and write down Basal segments, rates and total basal amount found on this screen. Scroll down to include all segments for the entire 24 hour day. Tap CANCEL. If you suspended insulin, you must tap RESUME INSULIN to restart your basal delivery.

Basal Settings ­ Max Basal and Temp Basal

1. From the Home screen tap Menu icon

2. Tap on Basal & Temp Basal

3. Review and write down the Max Basal Rate.
Write down if your Temp Basal is ON or OFF.

For current Omnipod DASH users|3

Settings (cont'd)
Write your current settings on the table provided on the next page.
Bolus Settings

1. From the Home screen tap Menu icon

2. Tap Settings to expand list. Tap Bolus.

3. Tap on each Bolus setting. For example, tap on Target BG & Correct Above.

4. Review and write down your Target BG & Correct Above values

5. Review and write down your Insulin to Carb Ratio

6. Continue to review and write down your Correction Factor, Reverse Correction, Duration of Insulin Action, Maximum Bolus and Extended Bolus settings

For current Omnipod DASH users|4

First, you must confirm your initial settings with your healthcare provider. Next, use the step by step instructions during First Time Setup to enter your initial settings into the Omnipod 5 App. Follow up with your healthcare provider after starting Omnipod 5 as some settings may need to be adjusted.

Current settings:

INITIAL PUMP SETTINGS BASAL SETTINGS

Max Basal Rate = ________ U/hr
Temp Basal (circle one) ON or OFF

Basal Rates 12:00 am - _________ = _________ U/hr _________ - _________ = _________ U/hr _________ - _________ = _________ U/hr _________ - _________ = _________ U/hr

BOLUS SETTINGS

Target Glucose (select one Target Glucose for each segment) 12:00 am - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL

Correct Above _________ mg/dL _________ mg/dL _________ mg/dL _________ mg/dL

(Target Glucose is the ideal glucose value desired. Correct Above is the glucose value above which a correction bolus is desired.)

Insulin to Carb Ratio 12:00 am - _________ = _________ g/unit _________ - _________ = _________ g/unit _________ - _________ = _________ g/unit _________ - _________ = _________ g/unit

Correction Factor 12:00 am - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit

Duration of Insulin Action ________ hrs

Max Bolus = ________ units

Extended Bolus (circle one)ON or OFF

For current Omnipod DASH users|5

FOR CURRENT
Omnipod System
USERS

Settings
Many of the settings in your Omnipod System are similar to those in Omnipod 5. But, it is important to remember that because Omnipod 5 is an automated insulin delivery system, it works differently than the Omnipod System. Because of this, it is very important to consider your current settings and discuss them with your healthcare provider before getting started. Find your current settings using the instructions below. Write your current settings on the table provided on the next page.

Basal Settings
3:00p 5/15
Bolus More actions Temp basal My records Settings Suspend

3:00p 5/15
Basal Programs Presets System setup Vibration

3:00p 5/15
Basal programs: basal 1 basal 2 Weekend [add new]

Basal 1: Segment
12:00a - 8:00a 8:00a - 3:00p 3:00p - 12:00a

3:00p 5/15
U/hr 0.60 0.80 0.75

Status

Select

1. On home screen select Settings

Back

Select

2. Select Basal Programs

Back Enable Select
3. Select the basal program to review. On the next screen, select View.

Daily basal: 17.15 U

Back

Graph

4. You will first see the graph, press List to view and write down your basal segments as shown

Bolus Settings
3:00p 5/15
Bolus More actions Temp basal My records Settings Suspend

Status

Select

1. On home screen select Settings

3:00p 5/15
Basal Programs Presets System setup Vibration

Back

Select

2. Select System setup

3:00p 5/15
Date/time Bolus/basal/calcs Alerts/reminders BG meter PDM options Diagnostics

Back

Select

3. Select Bolus/basal/calcs

3:00p 5/15
Bolus calc: On Ratios/factors/targets Temp basal: Off Extended: Off Bolus increment: 0.10U Max bolus: 10.00U Max basal: 3.00U/hr

Back

Select

4. Review and write down Temp Basal, Extended, Max Bolus and Max Basal settings. Then select Ratios/factors/ targets.

3:00p 5/15
Review all settings Target BG Min BG for calcs:
70 mg/dL IC ratio Correction factor Reverse correction: On Insulin action: 4.0hr

Back

Select

5. Select Review all Settings. Review and write down Target BG, IC Ratio, Correction Factor, Reverse Correction and Insulin Action.

For current Omnipod System users|7

First, you must confirm your initial settings with your healthcare provider. Next, use the step by step instructions during First Time Setup to enter your initial settings into the Omnipod 5 App. Follow up with your healthcare provider after starting Omnipod 5 as some settings may need to be adjusted.

Current settings:

INITIAL PUMP SETTINGS BASAL SETTINGS

Max Basal Rate = ________ U/hr
Temp Basal (circle one) ON or OFF

Basal Rates 12:00 am - _________ = _________ U/hr _________ - _________ = _________ U/hr _________ - _________ = _________ U/hr _________ - _________ = _________ U/hr

BOLUS SETTINGS

Target Glucose (select one Target Glucose for each segment) 12:00 am - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL _________ - _________ =  110  120  130  140  150 mg/dL

Correct Above _________ mg/dL _________ mg/dL _________ mg/dL _________ mg/dL

(Target Glucose is the ideal glucose value desired. Correct Above is the glucose value above which a correction bolus is desired.)

Insulin to Carb Ratio 12:00 am - _________ = _________ g/unit _________ - _________ = _________ g/unit _________ - _________ = _________ g/unit _________ - _________ = _________ g/unit

Correction Factor 12:00 am - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit _________ - _________ = _________ mg/dL/unit

Duration of Insulin Action ________ hrs

Max Bolus = ________ units

Extended Bolus (circle one)ON or OFF

For current Omnipod System users|8

Customer Care: 800-591-3455 Insulet Corporation, 100 Nagog Park, Acton, MA 01720
The Omnipod 5 Automated Insulin Delivery System is indicated for use by individuals with Type 1 diabetes mellitus in persons 2 years of age and older. The Omnipod 5 System is intended for single patient, home use and requires a prescription. The Omnipod 5 System is compatible with the following U-100 insulins: NovoLog®, Humalog®, and Admelog®. Refer to the Omnipod® 5 Automated Insulin Delivery System User Guide and www.omnipod.com/safety for complete safety information including indications, contraindications, warnings, cautions, and instructions. Warning: DO NOT start to use the Omnipod 5 System or change settings without adequate training and guidance from a healthcare provider. Initiating and adjusting settings incorrectly can result in over-delivery or under-delivery of insulin, which could lead to hypoglycemia or hyperglycemia. Refer to the Omnipod® and Omnipod DASH® Insulin Management System User Guides for complete safety information including indications, contraindications, warnings, cautions, and instructions. Medical Disclaimer: This handout is for information only and is not a substitute for medical advice and/or services from a healthcare provider. This handout may not be relied upon in any way in connection with your personal health care related decisions and treatment. All such decisions and treatment should be discussed with a healthcare provider who is familiar with your individual needs ©2022 Insulet Corporation. Omnipod, the Omnipod logo, DASH, the DASH logo, Simplify Life, the Omnipod 5 logo, are trademarks or registered trademarks of Insulet Corporation. All rights reserved. The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Insulet Corporation is under license. All other trademarks are the property of their respective owners. The use of third party trademarks does not constitute an endorsement or imply a relationship or other affiliation. INS-OHS-09-2022-00028 v1.0



References

Adobe PDF Library 15.0 Adobe InDesign 16.1 (Macintosh)