User Manual for Lindab models including: CCA, Circular Perforated Diffuser, CCA Circular Perforated Diffuser

Perforated diffuser - circular CCA

17 ago 2022 — Comdif CCA is a circular perforated displacement diffuser for freestanding installation. Behind the perforated front.

PDF preview unavailable. Download the PDF instead.

CCA GLOBAL ?t=1970237187
lindab | we simplify construction

Perforated diffuser - circular

CCA

Dimension

H

Description
Comdif CCA is a circular perforated displacement diffuser for freestanding installation. Behind the perforated front plate, CCA is equipped with individually adjustable nozzles, making it possible to alter the geometry of the near zone. The diffuser can be turned and has a circular duct connection (MF measure), so the diffuser can be connected at the top or bottom. The diffuser is suitable for the supply of large volumes of moderately cooled air.
· The diffuser is suitable for the supply of large volumes of air.
· The geometry of the near zone can be adjusted using adjustable nozzles.
· Plinths can be supplied as accessories.
Maintenance
The front plate can be removed from the diffuser, making it possible to clean the nozzles. The visible parts of the diffuser can be wiped with a damp cloth.

ØA

ØD

Size
1207 1607 2010 2510 3115 4020 5020 6320

ØA [mm] 250 300 360 400 520 630 730 830

Accessories

ØD [mm] 125 160 200 250 315 400 500 630

Can be supplied with plinth.

H [mm] 710 710 970 970 1490 2010 2010 2010

Weight [kg] 5,.00 7,.50 13,.0 18,.0 35,.0 58,.0 78,.0 106

Ordering example

Product Type Size

CCA

Order - accessories

Plinth:

CCAZ - 2 - size

aaaa

Materials and finish

Diffuser: Nozzles: Front plate: Standard finish: Standard colour:

Galvanised steel Black plastic 1 mm galvanised steel Powder-coated RAL 9003 or RAL 9010 - white

The diffuser is available in other colours. Please contact Lindab's sales department for further information.

Lindab reserves the right to make changes without prior notice

1

2022-08-17

lindab | we simplify construction
Perforated diffuser - circular

Technical data

pt [Pa] CCA 150

1207 1607 2010 2510 3115 4020 5020

100

70

6320

50

30 20 15 10
7 5
3 2
30 40 50 70 100 150 200 300

150 200 300 500 700 1000

0.5

1

2

1

2

34

60

55

50

45

40

35

30

25

20

LWA dB(A)

500 700 1000

qV [l/s] 2000 3000

2000 3000 5000

qV [m3/h] 10000

a0.2 [m]

3 45

7

10

b0.2 [m]

5

7

10

15 20

Recommended maximum volume flow.

The near zone is given at an under-temperature of -3 K to a maximum terminal velocity of 0.20 m/s.

Conversion to other terminal velocities - see table 1, correction of the near zone for -3 K and -6 K respectively.

Nearzone
Oval diffusion

CCA
h
v
vmax
Circular diffusion (factory setting)

Sound effect level
Sound effect level LW [dB] = LWA + Kok

Size
1207 1607 2010 2510 3115 4020 5020 6320

Centre frequency Hz

63 125 250 500 1K 2K 4K 8K

8

-1

1

1

-9 -17 -28 -40

10 -1

1

1

-8 -17 -29 -33

10 -1

3

0

-9 -17 -27 -40

7

-1

3

0

-7 -18 -28 -41

13

2

3

-1 -8 -17 -29 -27

13

2

3

-1 -7 -16 -28 -43

7

3

2

0

-6 -16 -19 -17

7

3

2

0

-8 -16 -20 -17

Sound attenuation

Sound attenuation L [dB] including end reflection.

Size
1207 1607 2010 2510 3115 4020 5020 6320

Centre frequency Hz 63 125 250 500 1K 2K 4K 8K

19 14 5

3

2

1

2

1

16 12 4

1

2

1

2

2

12 8

4

2

3

2

2

2

12 8

5

2

1

1

1

1

11 8

3

2

1

1

2

2

9

6

1

1

1

1

1

1

6

4

1

1

1

1

1

1

5

3

1

1

0

0

0

1

b0,2 a0,2

a0,2
a0,2 2

Table 1 Correction of the near zone (a0.2, b0.2)

Undertemperature
Ti - Tr
-K3
-6K

Maximum velocity
m/s 0.,20 0.,25 0.,30 0.,35 0.,40 0.,20 0.,25 0.,30 0.,35 0.,40

Mean velocity
m/s 0.,10 0.,12 0.,15 0.,17 0.,20 0.,10 0.,12 0.,15 0.,17 0.,20

Correction factor
1.,00 0.,80 0.,70 0.,60 0.,50 1.,20 1.,00 0.,80 0.,70 0.,60

2

Lindab reserves the right to make changes without prior notice

2022-08-17


Adobe PDF Library 15.0 Adobe InDesign 15.1 (Windows)