User Manual for MEAN WELL models including: LPF-40 Series 40W Constant Voltage Constant Current LED Driver, LPF-40 Series, 40W Constant Voltage Constant Current LED Driver, Constant Voltage Constant Current LED Driver, Voltage Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver, Driver
LPF-40-15 MEAN WELL USA Inc. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 6 Pages, 526.66KB
DocumentDocument40W Constant Voltage + Constant Current LED Driver LPF-40 series User's Manual IP67 Downloaded from Arrow.com. File Name:LPF-40-SPEC 2024-02-19 40W Constant Voltage + Constant Current LED Driver LPF-40 series SPECIFICATION MODEL LPF-40-12 LPF-40-15 LPF-40-20 LPF-40-24 LPF-40-30 OUTPUT DC VOLTAGE 12V 15V 20V 24V CONSTANT CURRENT REGION Note.2 7.2 ~12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V RATED CURRENT 3.34A 2.67A 2A 1.67A RATED POWER Note.5 40.08W 40.08W 40W 40.08W RIPPLE & NOISE (max.) Note.3 150mVp-p 150mVp-p 150mVp-p 150mVp-p VOLTAGE TOLERANCE Note.4 ±4.0% ±4.0% ±4.0% ±4.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±2.0% ±1.5% ±1.0% ±0.5% SETUP, RISE TIME Note.6 1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC 30V 18 ~ 30V 1.34A 40.2W 200mVp-p ±4.0% ±0.5% ±0.5% VOLTAGE RANGE 90 ~ 305VAC 127 ~ 431VDC Note.5 (Please refer to "STATIC CHARACTERISTIC" section) FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) LPF-40-36 36V 21.6 ~ 36V 1.12A 40.32W 250mVp-p ±4.0% ±0.5% ±0.5% LPF-40-42 42V 25.2 ~ 42V 0.96A 40.32W 250mVp-p ±4.0% ±0.5% ±0.5% LPF-40-48 48V 28.8 ~ 48V 0.84A 40.32W 250mVp-p ±4.0% ±0.5% ±0.5% LPF-40-54 54V 32.4 ~ 54V 0.76A 41.04W 350mVp-p ±4.0% ±0.5% ±0.5% TOTAL HARMONIC DISTORTION THD< 20%(@load60%/115VC,230VAC; @load75%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) INPUT EFFICIENCY (Typ.) 84% 85% 86% 87% 88% 88% 88.5% 90% 90% AC CURRENT 0.6A / 115VAC 0.3A / 230VAC 0.25A/277VAC INRUSH CURRENT(Typ.) COLD START 50A(twidth=210s measured at 50% Ipeak) at 230VAC; Per NEMA 410 MAX. No. of PSUs on 16A CIRCUIT BREAKER 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.75mA / 240VAC OVER CURRENT 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE Hiccup mode, recovers automatically after fault condition is removed 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 35V 34 ~ 40V Shut down and latch off o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover 41 ~ 49V 46 ~ 54V 54 ~ 63V 59 ~ 66V WORKING TEMP. MAX. CASE TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT Tcase=-40 ~ +80 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) Tcase=+80 20 ~ 95% RH non-condensing -40 ~ +80, 10 ~ 95% RH ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS Note.8 UL8750, CSA C22.2 No. 250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,EAC TP TC 004, IP67, J61347-1, J61347-2-13,GB19510.1,GB19510.14 approved ; design refer to UL60950-1 SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION Note.8 I/P-O/P:3.75KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load60%) ; BS EN/EN61000-3-3, GB/T 17743 , GB17625.1,EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020 MTBF OTHERS DIMENSION 3597.9K hrs min. Telcordia SR-332 (Bellcore) ; 438.9Khrs min. MIL-HDBK-217F (25) 162.5*43*32mm (L*W*H) NOTE PACKING 0.44Kg; 32pcs/15.08Kg/0.93CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. Please refer to "DRIVING METHODS OF LED MODULE". 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. De-rating may be needed under low input voltages. Please refer to "STATIC CHARACTERISTIC" sections for details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains. 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less. 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com 11. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:LPF-40-SPEC 2024-02-19 Downloaded from Arrow.com. 40W Constant Voltage + Constant Current LED Driver LPF-40 series BLOCK DIAGRAM EMI FILTER I/P & RECTIFIERS PFC CIRCUIT POWER SWITCHING O.L.P. PWM & PFC CONTROL fosc : 100KHz RECTIFIERS +V & FILTER -V O.L.P. DETECTION CIRCUIT O.V.P. DRIVING METHODS OF LED MODULE This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. 100 Vo(%) 60 (min.) (A) Constant Voltage area (B) Constant Current area (C) Hiccup Protection 50 100 Io(%) Typical output current normalized by rated current (%) In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Downloaded from Arrow.com. File Name:LPF-40-SPEC 2024-02-19 40W Constant Voltage + Constant Current LED Driver OUTPUT LOAD vs TEMPERATURE LPF-40 series LOAD (%) 100 80 60 40 20 -40 -30 0 15 30 40 50 60 AMBIENT TEMPERATURE,Ta () 70 (HORIZONTAL) LOAD (%) 100 80 60 40 20 -40 -30 -15 0 15 30 50 60 80 (HORIZONTAL) Tcase () LOAD (%) STATIC CHARACTERISTIC 100 90 80 70 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage. PF POWER FACTOR (PF) CHARACTERISTIC Tcase at 70 Constant Current Mode 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (40W) LOAD 115VAC 230VAC 277VAC TOTAL HARMONIC DISTORTION (THD) 48V Model, Tcase at 70 30 25 20 15 115VAC 10 230VAC 277VAC 5 0 50% 60% 70% 80% 90% 100% LOAD EFFICIENCY(%) EFFICIENCY vs LOAD LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications. 48V Model, Tcase at 70 93 92 91 90 89 88 87 86 85 84 83 82 277VAC 81 80 230VAC 79 78 115VAC 77 76 75 74 73 72 71 70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD THD Downloaded from Arrow.com. File Name:LPF-40-SPEC 2024-02-19 40W Constant Voltage + Constant Current LED Driver LIFE TIME LPF-40 series LIFETIME(Kh) 120 100 80 60 40 20 0 20 30 40 50 60 70 80 Tcase ( ) Downloaded from Arrow.com. File Name:LPF-40-SPEC 2024-02-19 40W Constant Voltage + Constant Current LED Driver MECHANICAL SPECIFICATION LPF-40 series CASE NO.: LPF-60B Unit:mm AC/N(Blue) AC/L(Brown) 300±20 SJOW 17AWG×2C & H05RN-F 2×1.0mm2 162.5 3.5 3.6 3.6 tc 60 3.5 tc : Max. Case Temperature 300±20 SJOW 17AWG×2C & 05RN-F 2×1.0mm2 +V(Red) -V(Black) 3.5 43 13 3.5 32 Recommend Mounting Direction INSTALLATION MANUAL Please refer to:http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:LPF-40-SPEC 2024-02-19