Installation Guide for Altronix models including: NetWay4EBTWP3, NetWay4EBTWPX3, NetWay4EBTX3, NetWay4EBTPL3, NetWay4EBTX3 4 Port Hardened 360W 802.3bt 4PPoE Switches, NetWay4EBTX3, 4 Port Hardened 360W 802.3bt 4PPoE Switches, 360W 802.3bt 4PPoE Switches, 4PPoE Switches, Switches

IINetWay4EBT3 Series L11X

Installation Guide NetWay4EBT3 Series

3 days ago — 115VAC, 60Hz, 3.5A or 230VAC, 50/60Hz, 2A. Power Output: • Four (4) 10/100/1000 Mbps Ethernet ports rated at. 90W each (360W total power). • IEEE 802.3af ...


File Info : application/pdf, 12 Pages, 1.30MB

PDF preview unavailable. Download the PDF instead.

Altronix-NETWAY4EBTWP3-Power-Supply-Installation-Instruction ?srsltid=AfmBOopdS5jnf3S5Xz6n-7dCv3yrGEhrOnbj2GOAejMOWxaXyV7d2tX
Fiber Solution

Embedded
TM

NetWay4EBT3 Series
4-port Hardened 360W 802.3bt 4PPoE Switches

Models Include:

NetWay4EBTWP3
- 4-port Hardened 802.3bt 4PPoE Switch and Power Supply/Charger
- NEMA4/4X, IP66 rated Outdoor enclosure.
NetWay4EBTWPX3
- 4-port Hardened 802.3bt 4PPoE Switch and Power Supply/Charger
- NEMA4/4X, IP66 rated Outdoor enclosure. - Accommodates up to four (4)
12VDC/4AH batteries.

NetWay4EBTX3
- 4-port Hardened 802.3bt 4PPoE Switch and Power Supply/Charger
- NEMA1 rated Indoor enclosure.
NetWay4EBTPL3
- 4-port Hardened 802.3bt 4PPoE Switch and Power Supply/Charger
- Backplane version.

Installation Guide

DOC#: NetWay4EBT3 Rev. 020924

More than just power.TM

Installing Company: ________________ Service Rep. Name: ___________________________________ Address: ______________________________________________ Phone #: ___________________

Overview:
Altronix NetWay4EBT3 Series Hardened 802.3bt 4PPoE Switches are equipped with one (1) 1Gb SFP port and four (4) POE IEEE802.3af/3at/3bt PoE ports rated at 90W each, with a 360W total power. Embedded LINQ Technology enables monitoring, control, and reporting from anywhere over the network. For unmanaged switches, refer to NetWay4E1BT3 Series.

Features:

Agency Listings:

LINQ Technology:

· CE European Conformity.

· Remote network management allows for camera/

Input: · 115VAC, 60Hz, 3.5A or 230VAC, 50/60Hz, 2A.
Power Output: · Four (4) 10/100/1000 Mbps Ethernet ports rated at
90W each (360W total power). · IEEE 802.3af, 802.3at, 802.3bt compliant.
SFP Ports: · One (1) Gigabit SFP port.
Ethernet Ports: · Four (4) 10/100/1000 Mbps ports. · Connectivity: RJ45, auto-crossover. · Wire type: 4-pair CAT5e or higher structured cable. · Speed: 10/100/1000 Mbps, half/full duplex,
auto negotiation.
Battery Backup · 48VDC charging circuit charges
sealed lead acid* or gel type* batteries. · Automatic switch over to stand-by battery
when AC fails.

device reset and diagnostic monitoring. · Provides local and/or remote access to critical
information via LAN/WAN. · Email and Windows Dashboard Alert notifications
report real-time events. · Event log tracks history.
Mechanical:
NetWay4EBTPL3: · Dimensions (H x W x D approx.):
10.75" x 8.875" x 2.375" (273.1mm x 225.4mm x 60.3mm). NetWay4EBTWPX3: · NEMA4/4X, IP66 Rated enclosure for outdoor use. · Accommodates sealed lead acid or gel type 12VDC batteries. · Dimensions (H x W x D approx.): 17.53" x 15.3" x 6.67" (445.3mm x 388.6mm x 169.4mm). NetWay4EBTWP3: · NEMA4/4X, IP66 Rated enclosure for outdoor use.

Indicators (LED):

· Dimensions (H x W x D approx.):

· Individual PoE On LEDs for each port.

13.31" x 11.31" x 5.59"

· Individual IP Link status, 10/100 Base-T/active

(338.1mm x 287.3mm x 142mm).

LEDs for each port.

NetWay4EBTX3:

· ALOS LED indicates fiber connection for SFP port. · NEMA1 Rated enclosure for indoor use

· Heartbeat LED indicates proper operation of the unit. · Dimensions (H x W x D approx.):

VLAN:

13.5" x 13" x 3.25" (342.9mm x 330.2mm x 83mm).

· Multiple management VLAN assignment.

· 802.1Q Tagged VLAN.

· Up to 10 VLAN groups. ID Range 2-4095.

*CAUTION: When using lead acid or gel type batteries, enclosure must be properly ventilated. Battery operational temperature should be derated 10-15ºC lower than manufacture's rated high temperature.

Recommended Altronix SFP Modules:
Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates. P1MM For use with Multi-Mode Fiber for distances up to 550m. P1SM10 For use with Single-Mode Fiber for distances up to 10km. P1AB2K For use with Single Strand Single-Mode Fiber for distances up to 2km. P1GCE For use with CAT5e or better for distances up to 100m.

- 2 -

Netway4EBT3 Series Installation Guide

Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. All units should be installed by a trained service personnel.
Installation: NetWay4EBTPL3: 1. Mount backplane in the desired location/enclosure with hardware supplied.
NetWay4EBTWP3/NetWay4EBTWPX3: 1. Remove backplane from enclosure prior to drilling. Do not discard hardware.
Note: Make sure that hardware will not interfere with components of the circuit board. 2. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings
to be used are 0.5". Follow manufacturer's specifications for the appropriate size opening. Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. To facilitate wire entry utilize weather-tight NEMA rated connectors (supplied), bushings, and cable. 3. Clean out the inside of enclosure before remounting circuit boards/backplane. 4. Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pg. 9, 10): Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom
hole of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible with mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 4, pg. 8). Pole Mount: Refer to Fig. 5 - 9 pg. 8. 5. Mount backplane in enclosure with hardware.
NetWay4EBTX3: 1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two (2) upper screws; level and secure. Mark the position of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure's upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 11). Secure enclosure to earth ground.
Power Connection: 1. Secure cabinet to earth ground. Connect AC power from overcurrent protective device circuit breaker
(20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on power supply board (Fig. 3, pg. 7). Use 14AWG or larger for all power connections (Battery, DC output, AC input). Connect ground lug to earth or green branch wire (12AWG min.). Keep power-limited wiring separate from non power-limited wiring by utilizing separate knockouts/ inlets. Minimum 0.25" spacing must be provided. CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
Input/Data Connections: 1. Connect structured cables from port marked [Port 1] to [Port 4] on NetWay unit to PoE compliant
cameras/edge devices (Fig. 1, pg. 4). 2. Insert SFP module into port marked [SFP], then connect cable to the SFP module on NetWay4EBTB to
the corresponding input of an SFP switch (Fig. 1, pg. 4).
Battery Backup: 1. Connect four (4) 12V batteries or two (2) 24V batteres wired in series to terminals marked [BAT ­ BAT +]
(Fig. 1, pg. 4), carefully observing polarity. When use of stand-by batteries is desired, they must be
lead acid or gel type. If batteries are housed in a weather-proof enclosure (NetWay4EBTWP3, NetWay4EBTWPX3),
it must be properly ventilated. Use Altronix Vent2 kit. Note: When batteries are not used, a loss of AC will result in the loss of output voltage. For outdoor battery backup, battery enclosure must have sufficient ventilation. Battery operational temperature should be derated 10-15ºC lower than manufacture's rated high temperature.
Security: Please ensure that the cover is secured with:
Key lock and screws for NetWay4EBTX3, Security Bolt for NetWay4EBTWP3 and NetWay4EBTWPX3.

Netway4EBT3 Series Installation Guide

- 3 -

Parameter Number of Ports Input Power Requirements
Environmental Conditions
Weights (approx.)

Technical Specifications:
Description Four (4) 10/100/1000 Mbps Ethernet ports rated at 90W each. IEEE 802.3af, 802.3at, 802.3bt compliant. One (1) Gigabit SFP Port.

115VAC, 60Hz, 3.5A or 230VAC, 50/60Hz, 2A.

Operating Ambient Temperature:

360W:

­ 30ºC to 70ºC (­ 22ºF to 158ºF)

240W:

­ 30ºC to 75ºC (­ 22ºF to 167ºF)

Storage Temperature: ­ 30ºC to 85ºC (­ 22ºF to 185ºF)

Relative Humidity: 85%, +/­ 5%

Operating Altitude: ­ 304.8 to 2,000m

Model

Product Weight

NetWay4EBTWP3 NetWay4EBTWPX3
NetWay4EBTX3 NetWay4EBTPL3

10.5 lb. (4.76 kg) 15 lb. (6.8 kg)
6.65 lb. (3.02 kg) 2.6 lb. (1.18 kg)

Shipping Weight
11.9 lb. (5.4 kg) 17.5 lb. (7.9kg) 7.55 lb. (3.42kg) 4.0 lb. (1.81kg)

Typical Applications:
Fig. 1

BAT ­ BAT + OUT ­ OUT +

PWR
Input: 48V-56VDC
+­

To 48V Stand-by Batteries

Fig. 1a
Master Reset

SFP1 ALOS
SFP Port Altronix Corp. Brooklyn, NY US www.altronix.com
Master Reset
Netway4EBTB

LG N

5A 250VA

USB Port for Configuring

Cable Guide
Separate Inlets

Fiber to Switch

115/230VAC Input

IP Device
(802.3af / 802.3at / 802.3bt)

IP Device
(802.3af / 802.3at / 802.3bt)

IP Device
(802.3af / 802.3at / 802.3bt)

IP Device
(802.3af / 802.3at / 802.3bt)

- 4 -

Netway4EBT3 Series Installation Guide

Configuring Units for Network Connection

­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­

Please be sure to visit altronix.com for latest firmware and installation instructions

­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­

Factory Default Settings

· IP Address:

192.168.168.168

· User Name:

admin

· Password:

admin

1. Set the static IP address for the laptop to be used for programming to the same network IP address as the Netway4EBTB. The default address of the Netway4EBTB is 192.168.168.168, I.E. 192.168.168.200.
2. Connect one end of the network cable to the network jack on the Netway4EBTB and the other to the network connection of the laptop.
3. Open a browser on the computer and enter "192.168.168.168" into the address bar. A dialog box Authentication Required will appear requesting both user name and password. Enter the default values here. Click on the button labeled Log In.
4. The status page of the Netway4EBTB will appear. Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the Netway4EBTB module will be found along with the Network Settings and Email Settings.

Network Settings:
In the IP Address Method field select [STATIC] or [DHCP], then follow the appropriate steps.

Static:
A. IP Address: Enter the IP address assigned to the Netway4EBTB by the network administrator. B. Subnet Mask: Enter the Subnet of the network. C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
Gateway configuration is required to properly receive emails from the device. D. HTTP Port: Enter the HTTP port number assigned to the Netway4EBTB module by the network administrator
to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections. E. HTTPS Port: Enter the HTTPS port number assigned to the Netway4EBTB module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access. F. Click the button labeled Submit Network Settings. A dialog box will display "New network settings will take effect after the server is rebooted". Click OK.

DHCP: A. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings. A dialog box will display "New network settings will take effect after the server is rebooted". Click OK. Next, click on the button labeled Reboot Server. After rebooting the Netway4EBTB will be set in the DHCP mode. The IP address will be assigned by the router when the Netway4EBTB is connected to the network. It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator). B. Subnet Mask: When operating in DHCP, the router will assign the subnet mask values. C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used. D. HTTP Port: Enter the HTTP port number assigned to the Netway4EBTB module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.

Secure Network Setup (HTTPS):

In order to setup HTTPS for a Secure Network Connection, a Valid Certificate and Key must be used. Certificates and Key should be in a ".PEM" format. Self Certifications should only be used for testing purposes as no actual authentication is being performed. In a Self-Certified mode, the connection will still state

that it is unsecure. How to upload Certificate and Key to setup HTTPS:

Netway4EBT3 Series Installation Guide

- 5 -

1. Open Tab Labeled "Security" 2. Select Tab Labeled "Email/SSL" 3. Scroll to bottom under "SSL Settings" 4. Click "Select Certificate" 5. Browse and select valid Certificate to upload from server 6. Click "Select Key" 7. Browse and select valid Key to upload from server 8. Click "Submit Files" Once the Certificate and Key is uploaded successfully you can proceed with setting up HTTPS in Network Settings. A. HTTPS Port: Enter the HTTPS port number assigned to the NetWay Spectrum module by the network
administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access. B. Click the button labeled Submit Network Settings. A dialog box will display "New network settings will take effect after the server is rebooted". Click OK.
VLans
VLans (Virtual Local Area Networks) are a subnetwork that allow for the grouping together of devices for improved network traffic as well as providing higher security by allowing greater control over which devices have access to each other. It is important to plan how you will setup your devices for each vLan.
Configuring vLan on the Altronix Netway4EBT3 Series Switch:
1. Ensure Laptop or PC being used to program the vLan settings is on a port that will be assigned to your first vLan configuration. By default the management portion of the software is assigned to vLan-1, CAUTION: Changing VID=1, the industry standard VLAN HOST address to any other VID address should be done with caution and performed only locally, since the change will drop the original HOST connection. Local access then facilitates a physical reconnection to respective port. Note: Only this vLan network allows access to IP management.
2. In Network Section click on VLan Tab. 3. Click Add vLan. 4. Enter a name for the vLan. 5. Enter a vLan ID, i.e. 10, 20, etc. Ensure this vLan ID is associated with a vLan setup on the main switch
and that your Laptop or PC being used for programming is on this same ID. Note: vLan ID could be any value 2-4094. 6. Assign vLan QOS (Quality of Service) priority. 0 = Lowest and 7 = Highest 7. Pick a Trunk port (Tagged Ports). Trunk ports are typically the main connection for network traffic for each group. They are usually connected to a network switch, WAPs, etc. 8. Pick the Access port(s) (Untagged Ports) associated with the vLan. Access Ports are typically used for Cameras, etc. If programming locally, ensure your laptop or PC is connected to one of these ports. 9. Save Configuration. 10. Repeat steps 2 - 9 to add another vLan. If unit is accidently programmed incorrectly and you cannot get into the Netway4EBT3 series programming, physically moving ports of your PC connected to the main switch to a correct port (when being programmed remotely), or, as a last resort, completing a factory reset locally and reprogramming the unit. 11. Advanced Port Settings: Unknown VID Packet Forwarding Configuration: On ingress unknown VID, Foward to a fixed set of ports. By default no forwarding is set. Configuration on Ingress Untagged Traffic: Trunk Port action for ingress UNTAGGED packets. By default do not drop packets. Keep Tag on Egress: Select if you want ACCESS Port to keep the vLan tag when sending egress packets. By default tags are stripped. Preferred VLAN Forwarding: For ACCESS Ports that belong to more than one VLan. Select preferred vLan to forward UNTAGGED ingress packets. By default preferred vLan is the last vLan created.

- 6 -

Netway4EBT3 Series Installation Guide

Fig. 2
Example vLan ID 20 for ports 3-4

Typical VLan Setup:

Example

vLan ID 10

OR

for ports 1-2

PWR

PASS THRU to next Switch (i.e. VLan ID 0 and/or 20)

Master Reset

Netway4EBTB

SFP1

ALOS

SFP Port

Trunk (i.e. VLan ID 10 and 20)

Fiber from Host Switch

Any Ethernet port can be used for VLan Pass Thru

Factory Reset Option:
1. Power the unit down. Allow approximately 30 seconds for the unit to power down completely.
2. Depress Master Reset button on Netway4EBTB while reapplying power to the unit (Fig. 1a, pg. 4, Fig. 3 pg. 7). Continue holding the button until the LEDs on board go through the start up cycle, then release the button.
3. The unit returns to the original factory settings.

Master Reset

Master Reset

Altronix Corp. Brooklyn, NY US
Netway4EBT www.altronix.com

Fig. 3

Netway4EBT3 Series Installation Guide

- 7 -

Wall Mount Installation:
1- Place unit at desired location and secure with mounting screws (not included) (Fig. 4, pg. 8). Fig. 4

Pole Mounting Using Optional Pole Mount Kit PMK1 (NetWay4EBTWP3) or PMK2 (NetWay4EBTWPX3):
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 and PMK2 outdoor pole mount kits are designed to simplify the installation of Altronix outdoor rated power supplies and accessories housed in models WP1, WP2, WP3 and WP4 NEMA rated enclosures. PMK1 and PMK2 can be mounted on 2" to 8" (50.8mm to 203.2mm) diameter round or 5" (127mm) square poles. Brackets are designed for use with the Wormgear Quick Release Straps (two included). 1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 5, pg. 8). 2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open
end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16" hex socket driver (Fig. 6, pg. 8 and Fig. 8, pg. 8).

Fig. 6

Fig. 6

Fig. 7

3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (Fig. 7, pg. 8).
4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 8, pg. 8).
5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (Fig. 6, pg. 8).
6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16" hex socket driver (Fig. 6, pg. 8).
7. Clip excess straps.

Fig. 8

Fig. 9 2" to 8"(50.8mm to 203.2mm) diameter round pole

Fig. 9a 5" (127mm) square pole

- 8 -

Netway4EBT3 Series Installation Guide

NetWay4EBTWP3 Mechanical Drawing and Dimensions (H x W x D approx.):
13.31" x 11.31" x 5.59" (338.1mm x 287.3mm x 142mm)

FRONT VIEW

RIGHT SIDE VIEW

11.31" (287.3mm)

3.96" (100.6mm)

1.61" (40.9mm)

12.75" (323.9mm)

13.31" (338.1mm)

13.50" (342.9mm) 12.00" (304.8mm)
10.25" (260.4mm) 5.59" (142mm)

FRONT VIEW COVER REMOVED
10.75" (273.1mm) 10.00" (254mm) 8.25" (209.6mm)

END VIEW
STAINLESS STEEL PIANO HINGE

10-32 X 0.375" (9.5mm) BRASS INSERT (X4)

PADLOCK LATCH ATTACHED WITH RIVETS (Ø 0.375" (9.5mm) PADLOCK EYE)

8.00" (203.2mm)

Ø 0.32 (8.1mm) MOUNTING HOLE TYP. 4 PLACES

10-32 X 0.25" (6.4mm) BRASS INSERT (X2)

Netway4EBT3 Series Installation Guide

- 9 -

NetWay4EBTWPX3 Mechanical Drawing and Dimensions (H x W x D approx.):
17.53" x 15.3" x 6.67" (445.3mm x 388.6mm x 169.4mm)

FRONT VIEW

RIGHT SIDE VIEW

15.3" (388.6mm)

1.67" (42.4mm)

5.00" (127mm)

17.36" (441 mm) 16.73" (425mm)

17.53" (445.3mm) 16.00" (406.4mm)

A

A

FRONT VIEW COVER REMOVED
14.54" (369.3mm) 14.00" (355.6mm) 12.23" (310.6mm)

316 STAINLESS STEEL PADLOCK LATCH ATTACHED WITH RIVETS. Ø 0.375 PADLOCK EYE
SECTION A-A
0.125" (3.2mm)

14.25" (362mm) 16.74" (425.2mm) 6.67" (169.4mm)
4.94" (125.5mm) 5.77" (146.6mm) 6.41" (162.8mm) 0.75" (19.1mm)

10-32 X 0.250 BRASS INSERT 4 PLCS.

MOUNTING PLATE
END VIEW
Ø 0.32" (8.1mm) WALL MOUNTING HOLE X 4
12.00" (304.8mm)

- 10 -

Netway4EBT3 Series Installation Guide

NetWay4EBTX3 Mechanical Drawing and Dimensions (H x W x D approx.):
13.5" x 13" x 3.25" (342.9mm x 330.2mm x 82.6mm)

1.40" (35.6mm)

4.85" (123.2mm)

4.85" (123.2mm)

1.40" (35.6mm)
1.20" (30.5mm)

3.25" (82.6mm)

1.20" (30.5mm)
1.40" (35.6mm)

0.75" (19.1mm)

12.5" (317.5mm) 11.0" (279.4mm)

0.75" (19.1mm)
0.9375" (23.8mm)

1.20" (30.5mm)
1.40" (35.6mm)

5.10" (129.5mm)

5.10" (129.5mm)

13.0" (330.2mm)

6.5625" (166.7mm)

5.10" (129.5mm)

3.25" (82.6mm)

0.9375" (23.8mm)

3.25" (82.6mm)

3.25" (82.6mm)

1.0" (25.4mm)
1.0" (25.4mm)

10.5" (266.7mm)

1.0" (25.4mm)

Netway4EBT3 Series Installation Guide

- 11 -

NetWay4EBTPL3 Mechanical Drawing and Dimensions (H x W x D approx.):
10.75" x 8.875" x 2.375" (273.1mm x 225.4mm x 60.3mm)
8.875" (225.4mm) 8.25" (209.5mm)
0.25" (6.4mm)

10.25" (260.3mm) 10.75" (273.1mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty

IINetway4EBT3 Series

L11X

MEMBER

- 12 -

Netway4EBT3 Series Installation Guide



References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Macintosh)