Jandy TruFit™ Bubbler with Pressure Check Technology
Owner's Manual
Model Number: JHCBUB
Section 1. Important Safety Instructions
? DANGER: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.
This underwater light must be installed by a licensed or certified electrician in accordance with the National Electrical Code® and applicable local codes and ordinances. In Canada, the Canadian Electrical Code and all applicable local codes and ordinances must be adhered to. Improper installation will create an electrical hazard, which could result in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Read and follow the specific instructions below.
⚠️ WARNING: Before installing this underwater lighted bubbler, read and follow all warning notices and instructions accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
Visit www.jandy.com for additional free copies of these instructions or call Zodiac Technical Support at 800.822.7933 (U.S.) or 888.647.4004 (Canada).
⚠️ WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
The Jandy® Pro Series Nicheless LED Lights are only available for 12-volt AC power. For supply connection, use only an isolating low voltage power supply with ungrounded output, evaluated and listed by a NRTL for swimming pool use.
ATTENTION INSTALLER: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
SAVE THESE INSTRUCTIONS
Section 2. Installing Jandy® TruFit™ Bubbler with Pressure Check Technology
The Bubbler Housing is pre-assembled for easy connection to a water supply line (1) and a conduit connection for the Jandy HydroCool Nicheless Pool Light cord to run through.
NOTE: Be sure to read the entire Owner's Manual completely and carefully to assure you understand the system before you start your installation.
NOTE: Do NOT use pipe dope for installation.
NOTE: Install plumbing before any electrical wiring.
2.1 Installation Preparations
The conduit for the low voltage supply cord (12Vac) can be run directly to a Junction Box where Light(s) connections and Low Voltage wires from the Transformer (sized correctly) are made. To reduce the risk of bad connections and unwanted voltage drops, all Power Cords on lights should run directly to the Low Voltage Transformer.
To ensure maximum safety, only use a transformer that can supply 12VAC and is listed or certified by a Nationally Recognized Testing Laboratory (NRTL) as compliant with UL 379, Standard for Power Units for Fountain, Swimming Pool, and Spa Luminaires.
The TruFit Bubbler is designed so that the lens of the tube is approximately 4"- 8" underwater, but can be deeper as long as the water supply can be increased. Keep in mind that the deeper the lens is underwater the less lighting effect will be above the water. Water flow should be adjusted to the desired plume while Jandy® HydroCool Nicheless Pool Light is set to the desired color mode. Use the table below to determine the approximate plume height.
1/2" NOZZLE PLUME HEIGHT
Water Depth | 2" | 4" | 6" | 8" | 10" | 12" |
---|---|---|---|---|---|---|
5 GPM | 9" | 6.5" | 4" | |||
10 GPM | 22.5" | 12" | 8" | 7" | 4.5" | 4" |
15 GPM | 59" | 28" | 16.5" | 10.5" | 8" | 7.5" |
20 GPM | 49" | 28" | 16" | 12.5" | 11.5" | |
25 GPM | 45.5" | 27.5" | 18" | 16" |
3/4" NOZZLE PLUME HEIGHT
Water Depth | 2" | 4" | 6" | 8" | 10" | 12" |
---|---|---|---|---|---|---|
10 GPM | 8" | 6" | 4.5" | |||
15 GPM | 15.5" | 10.5" | 7.5" | 6" | 5" | 4.5" |
20 GPM | 27" | 17" | 11" | 9" | 7.5" | 6.5" |
25 GPM | 41" | 26.5" | 16.5" | 12.5" | 11" | 8" |
30 GPM | 61" | 36" | 23" | 16.5" | 13" | 11" |
35 GPM | 49" | 34" | 22.5" | 17" | 14.5" | |
40 GPM | 64" | 49" | 30.5" | 22" | 17.5" | |
45 GPM | 61" | 39" | 27" | 21" | ||
50 GPM | 51" | 34.5" | 26.5" |
Figure 1. Package Contents
The TruFit™ Bubbler body comes with the Large Construction Cover pre-assembled and ready to pressure test.
Inside the TruFit Bubbler Body - a Small Construction Cover has already been installed. Do not remove this until the Bubbler Body is ready to have the light installed.
Figure 2. Bubbler Installation Guidelines
Diagram shows recommended lens depth to water line (2.5"-6" or 5-15 cm), minimum depth of 4" to the top of the light lens. It also indicates the recommended minimum distance from the wall or other bubblers (36" or 91 cm) to help avoid swirling and turbulence. The bubbler face must be completely snug and flush with the pool wall/surface without any protrusions. The diagram illustrates plaster, cement, and hydraulic cement layers.
Diagram shows a 12 VAC Transformer listed/certified for pool/spa equipment or Junction Box. It indicates a minimum distance of 48" (122 cm) from the pool edge to the transformer/junction box. It shows connections from Main Power and to the Pump Discharge/Manifold.
Figure 3. Large Construction Cap and Adjustable Sleeve
Diagram illustrates the Large Construction Cap and Adjustable Sleeve. Label A on the cap indicates where the lens surface will be glued if nothing is cut off of the sleeve. Label B indicates the level where the lens will be glued if all adjustment guides are cut off. The TruFit™ Bubbler has an adjustable sleeve that can easily be cut to fit the desired level. The large construction cap is designed to be a guide for showing the range of adjustability.
Figure 4. Bubbler Housing Installation Level
Diagram shows the bubbler housing installation level, indicating the placement relative to the water and power connections.
2.2 Installing the TruFit™ Bubbler Housing
- The TruFit Bubbler is designed to be installed during the gunite phase of pool building.
- Two conduits should be run to the Bubbler body: a. 1.5" PVC Pipe for water supply and b. 1" conduit for Pool Light Power Cord. NOTE: Do NOT use 90 degree fittings. Only 45 degree or sweep elbows are to be used.
- The 1.5" PVC pipe supplying the water to the Bubbler should have a gate valve or ball valve installed to adjust the water supply flow to create desired water/lighting effect.
- The conduit for the TruFit Bubbler power cord must run from the bubbler directly to a 12 VAC Transformer that is NRTL Listed/ Certified for swimming pool use.
- With the large construction cap on, install the Bubbler Housing onto the pipe so that the desired finished surface is above the lower indicator (B) and below the top of the cap (A). See figure 4.
- Important: After gunite, you need to "cove" around the TruFit Bubbler Housing. This is so that the Large Construction Cover can be removed and the adjustable sleeve can be installed and trimmed to be flush with the interior surface.
- Dig a cove around the top of the TruFit Bubbler Housing.
- Trim Adjustable Sleeve to be flush with the interior surface. NOTE: Threaded inserts on the adjustable sleeve are only used for vinyl/ fiberglass installations.
- Install the Small Construction Cover before plastering. This will ensure that the threads remain clean and that no debris falls into the Bubbler Housing.
- Backfill the "cove" area around the Bubbler Housing. After plastering, remove the Small Construction Cover.
- Install the Jandy® HydroCool Nicheless Pool Light.
2.3 Plumbing Multiple TruFit™ Bubblers
When installing multiple bubblers, it is advised that a looped manifold system be implemented to provide independent water flow control to each of the bubblers on the system. See Figure 1.
- Plumb an adjustable ball or gate valve to supply flow to the manifold assembly.
- If necessary, install reducer bushings to bring the supply lines to each bubbler down to the required 1.5" supply size.
- Plumb an adjustable ball or gate valve on each branch of the manifold.
- Use the individual ball valves to adjust the plume height on each of the bubblers to your preference.
Figure 5. Looped Manifold Plumbing
Diagram shows a looped manifold plumbing system for multiple bubblers, including a 3-way valve, water supply, pool return, manifold assembly, reducer bushings, ball valves, and LED bubblers connected via 1.5" PVC pipes.
2.4 LED Light Installation
The Jandy TruFit™ Bubbler with Pressure Check Technology is designed to be fitted with a Jandy® HydroCool Nicheless Pool Light. Once the pressure tests have been completed and the Small Construction Cover has been removed, you are ready to install the Jandy HydroCool Nicheless Light into the Bubbler Housing.
- Feed the power cable through the housing and conduit to the power source. Allow 18"-24" slack for service loop.
- Place the Light into the Bubbler and tighten into the threaded housing.
- See the Jandy HydroCool Nicheless light Owner's Manual for light installation instructions.
Section 3. Winterizing
The water level should be lowered to approximately 12 inches below the pool lights. Make certain that the water is drained out of the housing. Consult a Local Swimming Pool Professional for proper winterization. Minimum safeguard requires dropping the water level 2"-4" below the light. At NO TIME should there be water removed from the pool without checking ground water tables.
Section 4. Troubleshooting
Use the troubleshooting information in the following table for suggestions.
Symptom | Problem | Corrective Action |
---|---|---|
All lights fail to illuminate | Lights are not receiving power | Check 120VAC power supply into transformer. Check for 12VAC output at transformer. If 120 volts was used in the installation, damage may result and will not be covered under warranty. |
One or more lights are dim, blinking or not working | Poor connection or improper wire gauge | Separate each light and independently wire 12V to the single light only. Repeat this process on each light. If junction box is being used, check for proper connection of light cord. Verify that the correct wire gauge is being used between the transformer and junction box. |
Colored lights out of synch | Improper voltage supply or poor connection to the light | Verify that proper wire connections are being achieved for the lights that are out of synch. Reset all the lights to white by turning lights OFF for five (5) seconds, then turning ON. |