DSC Power 864 PC5020 Wiring Uplink's 5530M Cellular Communicators and Programming the Panel

⚠️ CAUTION:

ℹ️ NOTE:

For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

❗ IMPORTANT NOTE:

The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring the 5530M communicators to DSC Power864 PC5020

The diagram shows the wiring connections between the Uplink 5530M communicator and the DSC Power864 PC5020 alarm panel. The 5530M unit is depicted with its front view, showing an LED indicator and terminals labeled '+', '-', TIP, RING, DAT1, DAT2, IN1, IN2. The DSC Power864 PC5020 panel's terminal block is shown with labels such as AC, AUX+, BELL-, RED, BLK, YEL, GRN, PGM 1, 2, 3, 4, Zones 1 through 8 (each with a COM terminal), RING, TIP, R-1, T-1, and EGND. A 5600 Ohm resistor is illustrated connected across the Zone terminals, specifically between the terminal labeled 'Z1 COM' and the terminal labeled 'Z2'.

Wiring the 5530M with UDM to DSC Power864 PC5020 for remote upload/download

This section describes the wiring for the 5530M with UDM for remote upload/download functionality. The diagram illustrates the connection of the 5530M UDM unit to the DSC Power864 PC5020 panel. The 5530M UDM has terminals RT, D1, D2. The DSC Power864 PC5020 panel's terminal block is shown with labels including AC, AUX+, BELL-, RED, BLK, YEL, GRN, PGM 1-3, Zones 1-8, and RING, TIP, R-1, T-1, EGND.

Programming the DSC Power864 PC5020 Alarm Panel via the Keypad

LED indication on Keypad Keypad Entry Action Description
Ready: Steady Green *8 + Inst. Code To enter in Programming mode. (The default Installer code is 5555).
Armed: Steady Red
System: Blinking Yellow
301 To enter section "First phone number".
Ready: Steady Green
System: Blinking Yellow
123456*6*# Enter actual or non-existing number (any number will do, "123456" is an example) followed by *6* (F in hex).
Armed: Steady Red
System: Blinking Yellow
310 To enter section "System account code".
Ready: Steady Green
System: Blinking Yellow
1234*66 Enter 4-digit account number to receive the events from ("1234" is an example) and close it with *66 in hex.
Armed: Steady Red
System: Blinking Yellow
311 To enter section "Partition 1 account code".
Ready: Steady Green
System: Blinking Yellow
1234 Enter 4-digit account number to receive the events from ("1234" is an example).
Armed: Steady Red
System: Blinking Yellow
350 To enter section "Communicator Format Options".
Ready: Steady Green
System: Blinking Yellow
03# 03 is for Contact ID.
Armed: Steady Red
System: Blinking Yellow
351 Alarm/Restore Communicator Call Directions for partition 1.
Ready: Steady Green
System: Blinking Yellow
1,5# Toggle 1 to ON to enable Alarm/Restore reports. (if Zone 1 on the keypad is lit – then it's ON). Toggle 5 to OFF to disable Alternate Communicator.
Armed: Steady Red
System: Blinking Yellow
367 Open/Close Communicator Cell directions for partition 1 (if you have more partitions, repeat this and the next step for 368,369, 370 for partition 2,3,4).
Ready: Steady Green
System: Blinking Yellow
1,5# Toggle 1 to ON to enable Open/Close reports (if Zone 1 on the keypad is lit - then it's ON). Toggle 5 to OFF to disable Alternate Communicator.
Armed: Steady Red
System: Blinking Yellow
380 To enter section "First Communicator Options Code".
Ready: Steady Green
System: Blinking Yellow
1# Toggle 1 to ON to enable communications (options 3 and 4 must be OFF).
Armed: Steady Red
System: Blinking Yellow
381 To enter section "Second Communicator Options Code".
Ready: Steady Green
System: Blinking Yellow
7# Toggle 7 to OFF. The system automatically generates all reporting codes transmitted. To manually program the reporting codes in the menu 381, enable option 7 to ON and then set the desired reporting codes in menus 320 to 348.
Armed: Steady Red
System: Blinking Yellow
# Exit Programming mode.

Program Key-switch zone and output

LED indication on Keypad Keypad Entry Action Description
Ready: Steady Green *8 + Inst. Code To enter in Programming mode. (The default Installer code is 5555).
Armed: Steady Red
System: Blinking Yellow
202 To section "Partition Zone Assignment".
Ready: Steady Green
System: Blinking Yellow
1# Turn ON (the corresponding LED will be lit) only the zones that you intend to use – the rest must be OFF (LEDs are dim).
Armed: Steady Red
System: Blinking Yellow
001 To configure Zone 1.
Ready: Steady Green
System: Blinking Yellow
22# Enter 22 to program the zone type as "Momentary Keyswitch".
Armed: Steady Red
System: Blinking Yellow
013 To section "First System Option Code".
Ready: Steady Green
System: Blinking Yellow
1# 1 must be OFF to set the zones to end-of-line wiring configuration.
Armed: Steady Red
System: Blinking Yellow
009 To section "PGM1 and PGM2 Output Programming (Main Panel)".
Ready: Steady Green
System: Blinking Yellow
05# System Armed Status - output will activate/deactivate upon arm/disarm for selected partitions.
Armed: Steady Red
System: Blinking Yellow
# Exit Programming mode.

Programming the DSC Power864 PC5020 Alarm Panel via the Keypad for remote Upload/Download (UDL)

Display Keypad Entry Action Description
Ready: Steady Green *8 + Inst. Code To enter in Programming mode. (The default Installer code is 5555).
Armed: Steady Red
System: Blinking Yellow
401 To enter section "First Downloading Option Code".
Ready: Steady Green
System: Blinking Yellow
1,3,6# 1 and 3 must be disabled. 6 must be enabled.
Armed: Steady Red
System: Blinking Yellow
403 To enter section "Downloading Access Code".
Ready: Steady Green
System: Blinking Yellow
5020 Enter an Access code. (5020 is the default Access Code).
Armed: Steady Red
System: Blinking Yellow
404 To enter section "Panel Identification Code".
Ready: Steady Green
System: Blinking Yellow
5020 Enter a Panel Identification Code (5020 is the default Panel ID Code).
Armed: Steady Red
System: Blinking Yellow
405 To enter section "Answering Machine Double-call Timer".
Ready: Steady Green
System: Blinking Yellow
001 To disable double call.
Armed: Steady Red
System: Blinking Yellow
406 To enter section "Number of Rings to Answer On".
Ready: Steady Green
System: Blinking Yellow
001 Set the panel to answer on the first ring.
Armed: Steady Red
System: Blinking Yellow
# To Exit Programming Mode.

Keybus integration wiring of Uplink 5530M to DSC Power864 PC5020

This diagram details the Keybus integration wiring of the Uplink 5530M to the DSC Power864 PC5020. It shows the 5530M unit with terminals TIP, RING, DAT1, DAT2, IN1, IN2. The connections are made from the 5530M's DAT1 terminal to the YEL keypad terminal of the alarm panel, and from the 5530M's DAT2 terminal to the GRN keypad terminal of the alarm panel. The DSC Power864 PC5020 panel's terminal block is shown with labels including AC, AUX+, BELL-, RED, BLK, YEL, GRN, PGM 1-3, Zones 1-8, and RING, TIP, R-1, T-1, EGND, with specific emphasis on the YEL and GRN terminals for keypad connection.

Keybus integration instructions

NOTE 1: If the Arming/Disarming feature is enabled you can use the "Sync with Panel” feature from the Settings menu in the RControl mobile App. This way you will skip disabling and re-enabling the Arming/Disarming.

Switching from Keyswitch to Keybus

Device Configuration Notes

The device will apply the new configuration automatically.

NOTE 2: When switching the wiring of the device, make sure that the device is not powered on.

NOTE 3: When synchronizing or disabling and enabling the Arming/Disarming feature from the mobile application, make sure:

After enabling the Arming/Disarming feature, it may take up to 1 minute for the device to apply the new configuration.

Models: PC5020 DSC Power 864, PC5020, DSC Power 864, Power 864, 864

PDF preview unavailable. Download the PDF instead.

Uplink DSC PC5020 Power864 Wiring Programming Microsoft Word for Microsoft 365

Related Documents

Preview Uplink DSC Impassa (SCW9055, SCW9057) Wiring and Programming Guide
A guide to wiring and programming Uplink's 5530M Cellular Communicator and UDM with the DSC Impassa alarm panel for enhanced functionality and remote upload/download capabilities.
Preview Uplink Communicator Wiring and Programming Guide for Paradox SP4000
Detailed guide for wiring Uplink cellular communicators to the Paradox SP4000 alarm panel, covering installation steps and keypad programming for enhanced security system functionality.
Preview Uplink Cellular Communicator Wiring and Programming for Paradox Digiplex EVO HD
Comprehensive guide on wiring Uplink's cellular communicators to the Paradox Digiplex EVO HD alarm panel and programming the panel for optimal performance, including Contact ID reporting and keyswitch functions.