Amcor PLMB Series Portable Air Conditioner

Instruction Manual

Models: PLMB 9KE-410 / 12KE-410 / 15KE-410 (Plus Heater Versions)

Thank You

Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximise this product's performance.

For over 50 years Amcor has specialised in complete indoor environmental control, manufacturing and marketing; dehumidifiers, portable air conditioners, coolers, air purifiers, ionisers and aroma therapy scent diffusers. These world class products incorporate the latest technological developments.

Electric Connection

For your safety please read the following information.

Warning: This appliance must be earthed.

The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse. Should the fuse require replacement, it must be replaced with a fuse rated at 13 amp and approved to BS1362.

The plug contains a removable fuse cover that must be refitted when the fuse is replaced. In the event of the fuse cover being lost or damaged, the plug must not be used until a replacement cover has been obtained.

If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason, then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electric shock.

There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet.

Important

The wires in the mains lead on this appliance are coloured in accordance with the following code:

As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows:

The green and yellow wire must be connected to the terminal in the plug which is marked with the letter E or with the earth symbol ? or coloured green and yellow.

The blue wire must be connected to the terminal marked N or coloured black.

The brown wire must be connected to the terminal marked L or coloured red.

Diagram description: How to wire a 13 amp plug. It illustrates the connection points for the Green/Yellow wire to terminal E (Earth), the Blue wire to terminal N (Neutral), and the Brown wire to terminal L (Live). A cord clamp is also shown.

Safety Instructions

IMPORTANT

If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician.

WARNING

Safety Symbols and Meanings:

Parts

The air conditioner comprises the following parts:

Controls on the unit:

Display Indicators:

Installation

WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours.

This unit can easily be moved from one room to another. In doing so keep this in mind:

Important

The flexible exhaust hose can be extended from 660 to 2000 mm for mounting. This length has been designed especially according to the specifications of the air conditioner. Do not use an extension or exchange for a different hose as that may lead to malfunctioning. The exhaust air must flow freely; any blockage can lead to overheating of the air conditioner. Take care to prevent any sharp bow or bend in the exhaust.

Diagram description: Installation setup showing the air conditioner positioned near a window. A telescopic slide bar is fitted into the window opening, with the exhaust hose connected to it and extending outside. Dimensions indicate a 50 cm clearance required from obstacles.

Operation

ON/OFF

Press the ▶️ button to switch the unit on or off. A buzzer will beep, and the LCD will display 12:00 o'clock as default.

Setting the clock

Press the ⏰ button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press ⬆️ or ⬇️ to adjust the hour. Press ⏰ momentarily, the 2 right digits of the 4 digits will flash. Press ⬆️ or ⬇️ to adjust the minutes of the clock. Press the ⏰ button for 3 seconds again to activate the clock.

Setting the temperature

If you want to change the set temperature press ⬆️ or ⬇️ to set the temperature. The 2 digit display will indicate the set temperature.

Note: Reaching the set temperature depends on the room and outdoor climatic conditions.

Mode switch

Press the MODE button successively until the icon representing the desired mode is appearing (=> Cool ❄️ => Fan ? => Heat ? => etc). On the LCD-display you will see:

Each time the unit starts, it starts operating in cool mode with a set temperature of 22°C. The fan speed will be selected automatically. Heat mode is only available on EH models.

Fan speed

If you prefer a constant fan speed instead of the auto fan speed, press the FAN SPEED ? button successively; the fan icon on the LCD-display will rotate accordingly.

Switching LCD backlight ON/OFF

Heat

EH models feature a 1680 W electric heater that can heat a room on cooler days. With the mode switch select ?, set the desired temperature and the unit will heat until this temperature is reached. Fan speed is selected automatically. Do not place the unit near anything that could catch fire or be scorched. Do not obstruct the air outlet. The heat function will operate with or without the hose attached.

Timer

For all of the following TIMER programming, proceed firstly with these standard steps:

After 10 seconds the time display returns.

Programming the timer for ON - when the unit is OFF.

Diagram description: Timer example showing a circular time scale with segments indicating programmed ON and OFF times.

Programming the timer for OFF - when the unit is RUNNING.

Repeat OFF and ON

Programming the timer for repeat OFF and ON - when the unit is RUNNING.

Repeat ON and OFF

Programming the timer for repeat ON and OFF - when the unit is NOT RUNNING.

After a power failure, or after the unit has been unplugged, you will have to program the timer settings again.

Cancelling the timer function

In order to cancel the timer programming press the TIMER ⏱️ button momentarily, then it will return to the time display. The daily mode will be cancelled as well. The black segments in the circular time scale will disappear.

Air flow

On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed.

This way of directing the air flow is particularly convenient when using the remote control: a user friendly approach to your comfort.

In order to direct the air flow to a lower angle, raise the louvres housing by pulling it up only by the centre of its back rim.

Diagram description: Air outlet down, louvres closed. Air outlet up, louvres opened. Raising the louvres housing.

Sleep Mode

The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follow:

The set temperature will increase 1°C after 1 hour and a further 1°C after 2 hours.

Dehumidification

If the unit will be used mainly as a dehumidifier just let the warm air return in the room. Continuous drainage (see separate chapter) is then necessary and more efficient.

Air Filter

This air conditioner is equipped with two filter sets:

  1. A multi layer filter in the upper air inlet, to clean the circulated room air, which includes:
    • A screen filter, to remove dust particles.
    • An active carbon filter, to remove odours.
    • 3M Filtrete™ filter; to remove unhealthy particles from the air such as pollen, bacteria, animal dander and dust. Selected models have the 3M Filtrete™ filter as standard. However, if you require to add this to your model, or wish to purchase a replacement, call Amcor for details.
  2. A screen filter in the lower air inlet, to remove dust particles.

NOTE! The active carbon filter and the 3M Filtrete™ filter are delivered in a plastic packaging. Don't forget to install these filters. These filters take away unhealthy particles out of the room environment.

The filter holder on the rear of the unit can be opened. The active carbon filter and 3M Filtrete™ filter can be installed or removed. The screen filter is part of the filter holder.

Cleaning the air filters

Filter installation

Diagram description: Filter installation sequence showing four steps. Step 1 shows the filter holder. Step 2 shows inserting the active carbon filter. Step 3 shows inserting the 3M Filtrete filter. Step 4 shows the assembled filter holder.

NOTE!

Remote Control

The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal.

The operation of the unit by remote control is almost identical to the operation by the circular control panel. The only exception is the clock function.

Instead of the ⏰ button for setting the actual time and for programming the timer, there are 3 push buttons on the remote control as follows:

Diagram description: Remote control buttons labeled TIMER, ON, and OFF.

Emptying the Internal Water Container

Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display flashes, and the unit will switch off automatically.

To empty the water container do the following:

NOTE! When the air conditioner is in use, under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose.

Diagram description: Water container with drainage plug.

Continuous Drainage

Cleaning

WARNING! First of all switch off the unit and remove the plug from the wall socket.

Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions.

Clean the screen filter regularly with a vacuum cleaner. See also “air filter” section.

NOTE! Never use the air conditioner without the screen filter.

Trouble Shooting

Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property.

Problem Cause Solution
The air conditioner does not function. No power supply.
Is the LCD light flashing.
Timer function is active.
Connect to a functioning outlet and switch on.
Empty the internal water container.
Deactivate TIMER function.
The air conditioner does not seem to perform. In direct sunlight.
Windows or doors open, many people or a heat source in the room.
Dirty filter.
Air inlet or air outlet blocked.
Room temperature lower than the selected value.
Close curtains.
Close doors and windows, place an extra air conditioner.
Clean or replace the filter(s).
Remove the blockage.
Change temperature selection.
The unit is noisy. Unit stands uneven. Place on an even, solid surface (less vibrations).
The compressor does not work. The overheat protection is probably activated. Wait 3 minutes until the temperature has decreased, then turn on the unit again.
The remote control does not function. Distance too great.
Remote control signal not detected by the control panel.
The batteries are drained.
Make sure the remote control is correctly aimed at the control panel.
Replace the batteries.

To correct problems that have not been described in the table and/or if the recommended solutions fail to solve the problem, contact an authorized service centre.

Storage

Protect the unit against dust and store in a dry place, not accessible to children.

Diagram description: Cable storage illustration.

Technical Data

Model PLMB9KE-410
PLMB9KEH-410
PLMB12KE-410
PLMB12KEH-410
PLMB15KE-410
PLMB15KEH-410
Cooling capacity * BTU/h: 7500
kW: 2.2
BTU/h: 9400
kW: 2.75
BTU/h: 11300
kW: 3.3
Power consumption -Cooling kW: 0.8 kW: 1.0 kW: 1.5
-Heating (EH only) kW: 1.75
-Heating element (EH only) kW: 1.68
Mains V / Hz / PH: 220 - 240 / 50 / 1
Compressor model rotary
Fan speeds 3 (2+1 turbo)
Thermostatic range °C: 18 - 32
Refrigerant charge type / g: R410A / 420 type / g: R410A / 500 type / g: R410A / 630
Dimensions (w x h x d) mm: 500 x 840 x 415
Net weight kg: 33.1 kg: 34.3 kg: 39.3

PLMB9KEHx-410 and PLMB9KEx-410 series can be connected only to a supply with system impedance no more than 0.383 Ohm.

PLMB12KEHx-410 and PLMB12KEx-410 series can be connected only to a supply with system impedance no more than 0.247 Ohm.

PLMB15KEHx-410 and PLMB15KEx-410 series can be connected only to a supply with system impedance no more than 0.110 Ohm.

If necessary, please consult your supply authority for system impedance information.

* measured conform EN 14511

Subject to modifications without prior notice. For greater precision, please refer to the rating label placed on the product.

Reminder:

Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. ♻️

Your Guarantee

DOMESTIC AIR CONDITIONERS

If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge.

This guarantee is subject to the following terms:

This GUARANTEE is in addition to your Statutory Rights.

Creating Quality Environments

AMCOR LIMITED • 9 Ryan Drive • West Cross Centre • Great West Road • Brentford Middlesex • TW8 9ER • UK

For Customer Support Call: 020 8 560 4141

www.amcorgroup.com

Models: PLMB9KE-410 Plasma 15000 BTU Cooling Heating Portable Air Conditioner, PLMB9KE-410, Plasma 15000 BTU Cooling Heating Portable Air Conditioner, Cooling Heating Portable Air Conditioner, Heating Portable Air Conditioner, Portable Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 12 Pages, 1.71MB

PDF preview unavailable. Download the PDF instead.

AMCOR PLMB15KEH-410 (01)

References

Related Documents

Preview Amcor SF8000E Portable Air Conditioner User Manual
Comprehensive user manual for the Amcor SF8000E portable air conditioner, covering safety instructions, parts identification, installation, operation, maintenance, troubleshooting, and technical specifications.
Preview Amcor MD250 Mini Dehumidifier Instruction Manual
Official instruction manual for the Amcor MD250 mini dehumidifier. Learn about operation, safety, cleaning, and troubleshooting for your Amcor dehumidifier, designed to reduce moisture in small spaces.