nJoy Keen Series User Manual

Introduction

Thank you for purchasing our products! Please read this manual before using the product.

nJoy is a brand of power and backup protection products that create solutions for multiple levels of environment complexity, from residential to industrial. This UPS will protect your electronic equipment from physical damage and will provide emergency battery backup power to prevent data loss in the event of power problems.

Models Covered:

Model Numbers: UPLI-LI060KE-CG01B, UPLI-LI060KU-CG01B, UPLI-LI080KE-CG01B, UPLI-LI080KU-CG01B, UPLI-LI100KE-CG01B, UPLI-LI100KU-CG01B, UPLI-LI150KE-CG01B, UPLI-LI150KU-CG01B, UPLI-LI200KE-CG01B, UPLI-LI200KU-CG01B.

Document Reference: 949.34.22.1

Before using this product, carefully read all product documentation and retain it for future reference.

1. Package Contents

2. Product Overview

Keen 600/800 Series - Front and Back Views

Front View: Features a central geometric design, a power button (labeled 1), and LED indicators (labeled 2). The nJoy logo is visible at the bottom.

Back View: Shows two AC outlets (labeled 4), a USB communication port (labeled 9), and RJ11/RJ45 surge protection ports (labeled 10). The input power cord (labeled 3) is also shown.

Keen 1000/1500/2000 Series - Front and Back Views

Front View: Displays a geometric pattern, a Power On/Off Button (labeled 1), LED indicators (labeled 2), AC Mode LED (labeled 5), Battery Mode LED (labeled 6), and Fault LED (labeled 7). The nJoy logo is at the bottom.

Back View: Includes four AC outlets (labeled 4), an Input Circuit Breaker (labeled 8), a HID USB communication port (labeled 9), and RJ11/RJ45 surge protection ports (labeled 10). The input power cord (labeled 3) is also visible.

NOTE! The HID USB communication port and RJ11/RJ45 surge protection port are only available for Keen 600 USB, Keen 800 USB, Keen 1000 USB, Keen 1500 USB, and Keen 2000 USB models.

3. Important Safety Warnings

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

4. Installing Your UPS System

4.1 Hardware Installation Guide

  1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure maximum charge capacity. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the ON and OFF positions.
  2. With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage device (e.g., Zip drive, Jazz drive, Tape drive) into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder, or other large electrical device into the battery power supplied outlets, as their power demands can overload and possibly damage the unit.
  3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Ensure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g., air conditioner, refrigerator, copier). Avoid using extension cords.
  4. Press the power switch to turn the unit on. The power-on indicator light will illuminate, and the unit will emit a "beep".
  5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off, unplug at least one piece of equipment from the battery power supplied outlets, wait 10 seconds, ensure the circuit breaker/fuse is normal, and then turn the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  7. To store your UPS for an extended period, cover it and store it with the battery fully charged. Recharge the battery every three months to ensure battery life.

4.2 Software Installation Guide

For optimal computer system protection, install the UPS monitoring software from: http://www.powermonitor.software/ to fully configure UPS shutdown.

4.3 Positioning

For optimal ventilation of the UPS, please place it at least 15cm distance from any wall or object. This ensures adequate airflow around the unit.

⚠ CAUTION:
  • Do NOT plug LASER PRINTERS into any of the UPS outlets.
  • Do NOT plug any SURGE STRIPS into any of the UPS outlets.

5. LED Indication and Alarm

StatusLED Status (600/800)LED Status (1000/1500/2000)Alarm
NormalLED lightingGreen LED lightingOff
Battery DischargeLED flash once every 30 secondsYellow LED flash once every 30 secondsBeep once every 30 seconds
Battery LowLED flash once every 2 secondsYellow LED flash once every 2 secondsBeep once every 2 seconds
OverloadLED flash once every 0.5 secondsRed LED flash once every 0.5 secondsBeep once every 0.5 seconds
Off charging modeLED offAll LEDs offOff
FaultLED offRed LED lightingContinuous alarm

6. Troubleshooting

ProblemPossible CauseSolutions
The UPS does not perform expected runtimeBatteries are not fully charged.Recharge the battery by leaving the UPS plugged in.
Battery is slightly worn out.Contact Technical Support.
The UPS will not turn on.The on/off switch is designed to prevent damage by rapidly turning it off and on.Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC outlet.The unit must be connected to a 230Vac 50/60Hz outlet.
The battery is worn out.Contact Technical Support.
Outlets do not provide power to equipmentMechanical problem.Contact Technical Support.
Circuit breaker is tripped due to overload.Turn the UPS off and unplug at least one piece of connected equipment. Unplug the power cord of the UPS, then press the circuit breaker knob.
Batteries are discharged.Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a surge or spike.Contact Technical Support.

Disposal of Old Electrical & Electronic Equipment

[WEEE symbol] (Applicable in the European Union and other European countries with separate collection systems)

This symbol on the product or its packaging indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources.

EU Declaration of Conformity

We, manufacturer/importer:

DAI-TECH SA
Str. Berlin, Nr 6, C.P. 307160,
Dumbrăvița, Timiș, România

declare that the products UPS Keen Series, including models:

UPLI-LI060KE-CG01B, UPLI-LI080KE-CG01B, UPLI-LI100KE-CG01B, UPLI-LI150KE-CG01B, UPLI-LI200KE-CG01B, UPLI-LI060KU-CG01B, UPLI-LI080KU-CG01B, UPLI-LI100KU-CG01B, UPLI-LI150KU-CG01B, UPLI-LI200KU-CG01B

are in conformity with:

[CE Mark] (EC conformity marking)

Tested with the listed standards, the above-mentioned products were found in compliance with Directive 2015/863, Directive 2014/30/EC (EMC), and Directive 2014/35/EC (LVD).

Standards Compliance:

and in conformity with:

[RoHS] (RoHS conformity marking) in accordance with European Directive 2011/65/EU.

Declaration Details:

Stamp: DAI-TECH SA, ROMANIA

Date and location: Aug. 01, 2022, Timișoara

Signature and name: Tommy Lee

Models: UPLI-LI060KE-CG01B, UPLI-LI080KE-CG01B, UPLI-LI100KE-CG01B, UPLI-LI150KE-CG01B, UPLI-LI200KE-CG01B, UPLI-LI060KU-CG01B, UPLI-LI080KU-CG01B, UPLI-LI100KU-CG01B, UPLI-LI150KU-CG01B, UPLI-LI200KU-CG01B, UPLI-LI060KE-CG01B Uninterruptible Power Supply, UPLI-LI060KE-CG01B, Uninterruptible Power Supply, Power Supply

File Info : application/pdf, 24 Pages, 1,006.92KB

PDF preview unavailable. Download the PDF instead.

mmo 124640425 1732670176 7234 3058739

References

Adobe PDF Library 16.0.5 Adobe InDesign 17.1 (Windows)

Related Documents

Preview Njoy Keen Series UPS User Manual
Comprehensive user manual for the Njoy Keen Series Uninterruptible Power Supply (UPS) units, covering installation, operation, safety warnings, and troubleshooting.
Preview nJoy Keen 2000 USB UPS: 2000VA/1200W Line-Interactive Power Supply
Detailed specifications and features of the nJoy Keen 2000 USB Line-Interactive UPS, offering 2000VA/1200W power, simulated sinewave output, and multiple protection features for reliable power backup.
Preview Njoy Echo Pro 3000 UPS: Technical Specifications and Features
Detailed specifications for the Njoy Echo Pro 3000 Uninterruptible Power Supply (UPS), including capacity, input/output voltage, frequency, waveform, transfer time, and physical dimensions. Highlights include online double conversion, pure sine wave output, wide input range, and high efficiency.
Preview nJoy Token Series UPS User Manual - UPCSBLS660TTOAZ01B, UPCSBLS680TTOAZ01B
User manual for the nJoy Token Series UPS models UPCSBLS660TTOAZ01B and UPCSBLS680TTOAZ01B. Learn about installation, operation, safety, troubleshooting, and specifications for these power protection devices.
Preview nJoy Aster 6/10KT Black/White User Manual - Reliable Power Protection
Comprehensive user manual for the nJoy Aster 6/10KT Black/White Uninterruptible Power Supply (UPS). Learn about installation, operation, features like double-conversion technology, and troubleshooting for essential power continuity.
Preview nJoy Cadu Series UPS User Manual
Comprehensive user manual for the nJoy Cadu Series Uninterruptible Power Supply (UPS) models, covering installation, operation, safety, and troubleshooting.
Preview nJoy Aten PRO 3000 UPS: 3000VA/2700W Online Uninterruptible Power Supply Datasheet
Detailed specifications and features of the nJoy Aten PRO 3000, a 3000VA/2700W true double-conversion online UPS with pure sine wave output, microprocessor control, and advanced management capabilities.
Preview nJoy CA0312GX-AZ Battery Pack User Manual
User manual for the nJoy CA0312GX-AZ (36 Vdc) battery pack, detailing installation, safety precautions, product overview, and connectivity with UPS systems.