User Manual for AIOMEST models including: 1500-APP Pyrometer High Temp Thermometer, 1500-APP, Pyrometer High Temp Thermometer, High Temp Thermometer, Temp Thermometer, Thermometer

Non-contact infrared thermometer Instruction manual

YlmF

User Manual (PDF)

Pyrometer High Temp Thermometer with D:S=30:1 Support Bluetooth APP Data Saving, -58℉~2732℉, Non-Contact Temp Gun, IR Thermometer with 0.1~1.0 Emissivity for Smelting Furnace Industrial-GC-1500-APP : Industrial & Scientific

Pyrometer High Temp Thermometer with D:S=30:1 Support Bluetooth APP Data Saving, -58℉~2732℉, Non-Contact Temp Gun, IR Thermometer with 0.1~1.0 Emissivity for Smelting Furnace Industrial GC-1500-APP US-1500-APP(w/APP -58℉~2732℉)

1500-APP User Manual (PDF) GOLDCHAMP GOLDCHAMP Pyrometer,High,Temp,Thermometer,with,D:S=30:1,Support,Bluetooth,APP,Data,Saving,-58℉~2732℉,Non-Contact,Temp,Gun,IR,Thermometer,with,0.1~1.0,Emissivity,for,Smelting,Furnace,Industrial,GC-1500-APP,B0CHXXZHQR,B0CD7B81RB,B09WTLFQV2,B0BR3HL9QW,B0BXKLWMSH


File Info : application/pdf, 4 Pages, 1.09MB

PDF preview unavailable. Download the PDF instead.

A1GCcgENFfL
Non-contact infrared thermometer With APP function User manual

accuracy is critical, make sure the target is at least twice as large as the spot size. 4. Emissivity: Most organic materials and painted or oxidized surfaces have an emissivity of 0.95. Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Measure the tape or painted surface when the tape or painted reach the same temperature as the material underneath. 5. When changing from low temperature environment to high temperature environment or from high temperature environment to low temperature environment, please wait for 30 minutes, and then measure after the temperature of the machine is balanced with the ambient temperature. 2Quick start instruction

1Introduction Compact, rugged and easy to use. Just aim and push the button, read current surface temperatures in less than a second. Safely measure surface temperatures of hot, hazardous or hard-to-reach objects without contact.

How it works Infrared thermometer measures the surface temperature of an object. The unit's optics sense emitted, reflected, and transmitted energy which is collect and focused onto a detector. The unit's electronics transmitted energy which is display on the unit. For increased ease and accuracy the laser pointer makes aiming even more precise. Cautions Infrared thermometer should be protected for the following: --EMF(electro-magnetic fields) from arc welders, induction heaters. --Thermal shock(cause by large or abrupt ambient temperature changes allow 1 hours for unit to stabilize before use). --Do not leave the unit on or near objects of high temperature.
Warning Do not point laser at eye or indirectly off reflective surfaces. 1. When take measurement, point thermometer toward the object
to be measured and hold the yellow trigger. The object under test should be large than the spot size calculated by the field of view diagram. 2. Distance  spot size: As the distance from the object increase, the spot size of measuring area becomes large.

1. Remove the silica gel set, remove the battery cover screw with a screwdriver, and then slide out the battery door, install battery correctly. And Put back to the battery door screws and silica gel .Pull the trigger, LCD display reading  battery icon. Release the trigger and the reading will hold for 10 seconds.The content displayed on the screen will all light up, and after hearing the beep, the startup procedure has been completed.
LCD display: Display area:36.4×34.6(mm)character 13.3mm high.
A Data Hold B Main dislplay value C Memory storage D Maximum E Continuous measurement F K type temperature symbol (this unit Without this feature) G High temperature alarm temperature H Alarm of high temperature prompt I Alarm of Low temperature prompt J Low temperature alarm temperature K Battery voltage Low L Backlight symbol M Additional features N Minimum O Average P The maximum and the minimum difference Q Temperature of the unit R Laser pointer turn on prompt S Emissivity symbol(According to the different test objectives,
adjust the transmission frequency, there is a detailed parameter table below) T Measuring the symbol Note: When [HOLD] is displayed, it means that data hold has been turned on, and the displayed value depends on the display mode you choose (MAX/MIN/The maximum and the minimum difference/AVG)

3. Field of view: Make sure the target is larger than the unit's spot size. The smaller the target the close measure distance. When

2. Locating a hot spot aim the thermometer outside the area of interest, then scan across with up and down motions until you locate the hot spot.(please turn on the laser to for accurate measuring)

1

3. Diagram description
(1) Trigger  Press for turn on, and then display test result and hold data automatically(display HOLD) after unclamping switch. Trun off automatically after 10 seconds without operate.
(2) Laser pointer button use this button to toggle back and forth
between the laser being visible and not visible . lasers are visible when the " " display on the LCD,
(3) Back light/UP button  When product working, press it for turn on back light, press again for turn off. the second functian please see (4)
(4) MODE buttonPress MODE button for cycle options MAX ­ MIN-DIF- AVG - HAL­ LAL mode. AMAXMeasure maximum data current BMINMeasure minimum data current CAVGCalculate the average of all measure data DDIFThe maximum and the minimum difference EHAL/LALHAL is Alarm of high temperature. LAL is Alarm of low temperature. Option Alarm of temperature mode, press"Back light/UP"button for up alarm temperature. press"T/DN"button for down alarm temperature. When LCD display " HI" means measure result exceeded the alarm temperatureWhen LCD display " LOW " means measure result under the alarm temperature
(5) T/DN buttonWhen product working, press direct for  / 0F select. second function please see (4). If for some reason the toggle button does not work, the product is probably NOT in the correct mode. If that is the case, with the meter on, press the "Mode" button and look at the display change. The T/DN button will not work if the meter is in "REC" mode, for "record." Put the meter into a different mode, such as "AVG" and then push the T/DN button and you should see the change to a  and back and forth. The same for the "Light/UP" button, Press "Mode" to put the meter into a different mode, such as "AVG" and then push the "Light/UP" button and you should get the backlight.
(6) E/ button  When product working, press direct into set Emissivity mode, press"Back light/UP"button for up Emissivity . press"T/DN"button for down Emissivity. Long press the button, the head lamp lighted.
(7) LCD (8) Battery door: When replace battery ,take off the scrrew ,then
slide open the battery door. The diagram below operation 1. Use the screwdriver to unscrew the bottom screw
2. Catch the hook and take the cover of battery out from the bottom;

Note: 1) Do not use solvent to clean lens. 2) Do not submerge the unit in water. 3) Emissivity will back to the initial value (0.95) after replacing
battery,. Should adjust again when use. 4) During the test, if you find that the reading has not changed,
please check whether "REC" is displayed on the screen. If so, the product at the recorded reading model .please turn it off and then it will display the measurement readings normally.
4specifications

Temperature range Accuracy
distance spot ratio Emissivity

-50 to 1500(-58 to 27320F) ±4/7.20F, -50 to 0(-58 to 320F) ±(2% reading +2/3.60F), 0 above 30:1 0.11.0 adjustable

Resolution

0.1(0.10F)<1000, 1(10F)>1000

Repeatability

1% of reading or 1

Response time

<250msec, 95%response

Spectral response

8-14um

Operating temperature 0 to ~40(32 to 1040F)

Storage temperature -20~60(-4~1400F) without battery

Relative humidity
Ambient temp range of guarantee for accuracy
Weight/dimensions

Operating :10-95%RH; Storage: 10-95%RH 23~28 160g; 192×95×63mm

Power

9V battery, 6F22 or NEDA 1604

Battery life

Laser models:12hrs

Attached list Applicable Emissivity for Different Material ( For reference only )

Material Emissivity

Material

Emissivity

Asphaltum 0.90 to 0.98 TextileBlack 0.98

Beton

0.94

Human Skin

0.98

Cement

0.96

Soap bubble

0.75 to 0.80

Sand

0.90

Charcoalpowder 0.96

Soil

0.92 to 0.96 Lacquer

0.80-0.95

Water

0.92 to 0.96 Lacquer reluster 0.97

Ice

0.96 to 0.98 RubberBlack 0.94

Snow

0.83

Plastic

0.85-0.95

Glass

0.90 to 0.95 Timber

0.90

Ceramic 0.90 to 0.94 Paper

0.70-0.94

Marble

0.94

Chromic oxide

0.81

Gypsum 0.80 to 0.90 Copper Oxide

0.78

Compo

0.89 to 0.91 Iron Oxide

0.78 to 0.82

Brick

0.93 to 0.96 Stainless steel

0.2-0.3

Above picture and content just for your reference. Please be subject to the actual products if anything different or updated. Please pardon for not informing in advance.

3Maintenance 1) Lens cleaning: Blow off lose particles using clean compressed
air. Gently brush remaining debris away with a moist cotton cloth. 2) Case cleaning: Clean the case with a damp sponge/cloth and mild soap. 3) Please take out the battery when not using for a long time.

CONTACT US For any problem or concern, welcome to email us for prompt response. AFTERSALES1010@HOTMAIL.COM P.S. To make sure you can receive immediate solution and your requests processed quickly, please email us with these information: 1. Order Number 2. Platform of Your Purchase 3. Full Model Number 4. Description of the Problem(Attaching videos or photos can help us troubleshoot the problems even faster)

2

Intelligent Meter Operation manual Summary
Intelligent Meter is a comprehensive intelligent hardware management platform. Through Intelligent Meter App, you can complete the convenient between mobile phones and intelligent hardware,achieve the interconnection and intercommunication between devices and users. Intelligent Meter supports multiple types of devices, Such as intelligent instrument, electrical instrument, anemometer and infrared thermometer.
APP download and installation Scan the below QR code to download directly, or search for "Intelligent Meter" in the APP Store, Google Play download and install the "Intelligent Meter".

Retrieve password
When the user forgets the login password, the login password can be reset through this function . 1) Enter the account number to retrieve the password; 2) Click the "send" button to send the verification code to the email; 3) Enter the verification code, reset the new password, click "submit reset", and then you can log in to the app with the new password .

Account registration
To register an email account, enter the email number and password, and click Register. This account is used for future login;

Add device
1) Click add equipment, select the equipment to be
added, and operate according to the operation
instructions to add;

Account login
Enter the account and password and click login
3

1) Click "start using" to enter the function page.

4Click the settings button to view the software version, set the sampling rate or auto shutdown time.

2Function introduction

1. Wake up function button: infrared thermometer app is connected to the mobile phone. When infrared thermometer app is automatically closed or the mobile phone program is closed, you can wake up the infrared thermometer through this button.When the infrared thermometer and the mobile phone are not in the same place, the infrared thermometer can be turned on by remote control, and the distance in the open place can reach 80m 2. Measurement button: press the button,the infrared thermometer can carry out for continuous measurement. 3. Stop button: press the button to stop the continuous measurement. And stop recording data. 4. Reset button: press the button to reset the temperature value of the main interface. 5, 6, 7, 8, 9, 10, 11, 12 and 13 are the keys corresponding to the infrared thermometer. You can use the keys on the mobile app to operate and control the infrared thermometer. 3)Click the "data" button to view the historical recording time and historical recording data, and press the button in the upper right corner to download the data.

 After using this product, if it is no longer used for a long time, it is recommended to remove the battery, otherwise the battery will be consumed all the time.
CONTACT US For any problem or concern, welcome to email us for prompt response. AFTERSALES1010@HOTMAIL.COM P.S. To make sure you can receive immediate solution and your requests processed quickly, please email us with these information: 1.Order Number 2.Platform of Your Purchase 3.Full Model Number 4.Description of the Problem(Attaching videos or photos can help us troubleshoot the problems even faster)

4